• Title/Summary/Keyword: Tape measurement

Search Result 160, Processing Time 0.028 seconds

Measurement reliability of irreversible stress/strain limits in Sn-Cu double layer stabilized IBAD/RCE-DR processed GdBCO coated conductor tapes under uniaxial tension at 77 K

  • Bautista, Zhierwinjay;Diaz, Mark Angelo;Shin, Hyung-Seop;Lee, Jae-Hun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.4
    • /
    • pp.36-40
    • /
    • 2018
  • In this study, the electromechanical properties in Sn-Cu double layer stabilized GdBCO coated conductor (CC) tapes with and without external lamination under uniaxial tension were examined at 77 K and self-field. Their irreversible stress and strain limits were determined using a loading-unloading scheme based on different critical current ($I_c$) recovery criteria. The repeated tests were performed and statistical estimation was done to check the reproducibility depending on the criterion adopted in evaluating the electromechanical properties. From the results, it showed that the Sn-Cu double-layer stabilized CC tapes have the higher irreversible stress limit, but lower irreversible strain limit as compared to brass laminated ones. Through the repeated tests, it can be found that a small scattering of irreversible limits existed in both CC tape samples. Finally, similar strain sensitivity of $I_c$ in both CC tapes was obtained.

Transport Loss Characteristic of the Bifilar Pancake Type Fault Current Limiting Coil using Coated Conductor (Coated Conductor를 사용한 무유도 팬케이크형 한류 코일의 통전 손실 특성)

  • Park, Dong-Keun;Bang, Joo-Seok;Yang, Seong-Eun;Ahn, Min-Cheol;Sim, Ki-Deok;Yoon, Yong-Soo;Nam, Kwan-Woo;Seok, Bok-Yeol;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.3
    • /
    • pp.21-25
    • /
    • 2007
  • Superconducting fault current limiter (SFCL) is attractive apparatus to reduce fault current in power grid. Since it is applied to the alternating current (AC) power line, the SFCL has losses in the normal operation. Recently, coated conductor (CC) is noticeable material employed for resistive bifilar winding type SFCL in many research groups. Bifilar structure is expected to have low AC loss by magnetic field offset as compared with the single tape structure in the same length. This paper reports about characteristic of bifilar pancake type coil for SFCL application in AC loss aspect. The bifilar coil is wound using CC with facing on HTS sides each other. Transport AC loss measurement and characteristic analysis of the bifilar coil using CC have been performed at 77K. The test results are compared with the Norris equations and the test results of non-inductively wound paralleled solenoid type coil which is suggested and tested in this group at present.

The Effect of Hallux Valgus Correction Taping on Foot Arch and Static Balance of Young Adult with Hallux Valgus

  • Son, Jun-Seob;Jo, Yeon-Ju;Kim, Suhn-Yeop
    • Journal of Korean Physical Therapy Science
    • /
    • v.24 no.3
    • /
    • pp.18-29
    • /
    • 2017
  • Purpose: The purpose of this study was to identify the effect of hallux valgus (HV) correction taping on the foot arch and balance of young adults with HV of the big toe. Methods: Forty-eight adults volunteered to participate in this study; of them, the 37 feet (11 men, 26 women) with ${\geq}15^{\circ}$ lateral bending of the metatarsophalangeal joint of the big toe, on a goniometer, were selected as the target foot. Non-elastic correction tape was applied to the foot with HV, while the target foot was used to evaluate the changes, before versus after taping, in the lateral bending angle of the big toe, navicular drop level, Clarke angle, and static balance using a Gaitview system. Each measurement was performed three times, and the average of each set was used in the analysis. The patients'general characteristics were compared by using an independent t-test, and the measurement values were analyzed by using a paired t-test. Results: After taping, the lateral bending angle of the toe significantly decreased (p<.05), difference in navicular drop level significantly decreased (p<.05), the Clarke angle significantly increased (p<.05), and static balance significantly improved (p<.05). Conclusion: We showed that HV taping resulted in an immediately improved HV angle, arch, and single-leg standing balance on the foot with HV. However, further studies should investigate the correlation between HV and foot arch.

Sportswear Physiological Optimization: Effects of Clothing ease, local heating and materiales (운동복의 기능성과 쾌적성에 관한 연구)

  • Lee Young Suk;An Tae Whan
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.2 s.38
    • /
    • pp.127-138
    • /
    • 1991
  • The aim of the present stud)r has been to obtain new and additional data allolwing a better design of sports garments as well as a better choice among some materiales, through measure-ment of body surface changes in the upper trunk in movement, measurement on the effects of local heating on other parts of the body and measurement of the thermal resistance of 6 types of materials applied on a manikin. In the first experiment, the upper trunk was divided in 32 Parts, the surface of which was measured by the tape method for two upper limb positions: extension at $90^{\circ}$ and $180^{\circ}$. In the second experiment, skin temperature, local thermal sensations and whole body thermal sensation were measured every 5 minutes during 40 minutes. The four areas of the shoulder, abdomen, hande and feet were heated with the hot pack at $50^{\circ}C$. In the third experiment, the regional thermal resistance of the various materials selected, in two different cases of clothing ease, have been measured by using a thermal manikin. Resultes of experiments were: 1. Extensions cause the upper front part of the trunk surface to lengthen vertically while the back tends to stretch in width. 2. Skin temperatures of the upper limbs are influenced by the abdomen and shoulder boatings. The correlation between the whole body thermal sensation and the upper trunk thermal sensation is significantly asserted. 3. Ceramic and aluminium coated materiales offer the most effective thermal resistance; ease in clothing increases the thermal resistance at the breast and the abdomen as well as the clo value of the materials.

  • PDF

Accuracy Evaluation and Analysis of SLAM for the Advancement of Forest Investigation (산림조사 고도화를 위한 SLAM의 정확도 평가 및 분석)

  • Yun, Hee-Cheon;Lee, Jong-Sin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.734-739
    • /
    • 2018
  • The National Forestry Inventory of Korea has started the 7th (2016 ~ 2020) survey from the first (1972 ~ 1974) National Forest Situation Survey. The diameter at breast height was measured using a diameter tape, and the tree height was measured using a hypsometer in the National Forestry Inventory of Korea from the 1st to recently the 7th surveying. In the case of the diameter tape, however, irregularly shaped trees may cause a large error. In the case of a hypsometer, the height may be measured indirectly in 10 cm increments to the front edge of the tree, so that the accuracy may be lowered. This paper suggests the use of SLAM to improve the accuracy and advance forest investigations. For this purpose, a test bed for the measurement of DBH and tree height was set up, and the scan data was acquired directly using SLAM equipment. The accuracy of DBH and tree height measurements were analyzed. As a result, it was possible to calculate directly the DBH and tree height to 1mm unit, and it showed that the DBH accuracy of 2cm or less and the accuracy of the tree height accuracy of 1.3cm or less are sufficient for practical use. Based on the results, the scan data will be acquired for sample points and analyzed.

A Study on Smart Accuracy Control System based on Augmented Reality and Portable Measurement Device for Shipbuilding (조선소 블록 정도관리를 위한 경량화 측정 장비 및 증강현실 기반의 스마트 정도관리 시스템 개발)

  • Nam, Byeong-Wook;Lee, Kyung-Ho;Lee, Won-Hyuk;Lee, Jae-Duck;Hwang, Ho-Jin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.1
    • /
    • pp.65-73
    • /
    • 2019
  • In order to increase the production efficiency of the ship and shorten the production cycle, it is important to evaluate the accuracy of the ship components efficiently during the drying cycle. The accuracy control of the block is important for shortening the ship process, reducing the cost, and improving the accuracy of the ship. Some systems have been developed and used mainly in large shipyards, but in some cases, they are measured and managed using conventional measuring instruments such as tape measure and beam, optical instruments as optical equipment, In order to perform accuracy control, these tools and equipment as well as equipment for recording measurement data and paper drawings for measuring the measurement position are inevitably combined. The measured results are managed by the accuracy control system through manual input or recording device. In this case, the measurement result is influenced by the work environment and the skill level of the worker. Also, in the measurement result management side, there are a human error about the lack of the measurement result creation, the lack of the management sheet management, And costs are lost in terms of efficiency due to consumption. The purpose of this study is to improve the working environment in the existing accuracy management process by using the augmented reality technology to visualize the measurement information on the actual block and to obtain the measurement information And a smart management system based on augmented reality that can effectively manage the accuracy management data through interworking with measurement equipment. We confirmed the applicability of the proposed system to the accuracy control through the prototype implementation.

COMPARISON OF BITE FORCE WITH DENTAL PRESCALE AND UNILATERAL BITE FORCE RECORDER IN HEALTHY SUBJECTS (Dental Prescale과 편측 교합력 측정기를 이용한 정상성인의 교합력 비교)

  • Kwon Ho-Keun;Yoo Ja-Hea;Kwon Young-Sook;Kim Baek-Il
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.103-111
    • /
    • 2006
  • Statement of problem: The previous unilateral bite force recorder has several limitations for taking long time for measuring and causing discomfort to subjects. Because of these reasons, it could not use widely for epidemiological researches. However, 'Dental Prescale System' which is new equipment for measuring bite force, is more convenient for measuring bite force than previous unilateral recorder. Purpose: The purpose of this study was to compare a new technique(Dental Prescale System) using pressure sensitive foils for recording of maximal jaw closing force with conventional measurement using unilateral bite force recorder Material and method: This studies included 22 healthy dental students in college of dentistry Yonsei university in Rep of Korea. Mean age was 23.9 years. All subjects had continuous dental arches and no significant malocclusion or signs from the teeth and craniomandibular system. The Dental Prescale System (Fuji Film, Tokyo, Japan) consists of a horseshoe-shaped pressure sensitive sheet (50H, R type) and a computerized scanning system.(FPD705) We also used unilateral bite force recorder(Denbotics Co. Seoul, Rep.Korea) for comparing with Dental Prescale. Results and conclusion: The total bite force recorded with Dental Prescale System (1423 N) was systematically higher than that recorded by unilateral bite force recorder. (256 N) However, the maximum bite force values measured in the two ways were significantly correlated (r=0.46, p<0.05). The Dental Prescale bite force calculated for first molar (208 N) was lower than that recorded by unilateral bite force recorder. (256 N) The two values were also very significantly correlated. (r=0.66. p<0.001) There were significantly different in bite force between two measurement methods. The reasons were first, unilateral bite force recorder measured only the bite force of a part of teeth, and Dental Prescale measured the total teeth force. Second, in measurement, a difference in muscle contraction appeared by an extent of mouth-opening. Third, unilateral bite force recorder has the reducing effect of the bite force by protective tape. Fourth, Dental Prescale has limitations during the computer scanning procedure. Therefore, Dental Prescale System is considered to be a very promising alternative to be conventional bite force recording methods.

Effect of EMG Biofeedback Training and Taping on Vastus Medialis Oblique for Function Improvement of Patient with Patella Malalignment (내측 사선 광근에 대한 EMG Biofeedback 훈련과 테이핑 적용이 슬개골 부정렬 환자의 기능향상에 미치는 효과)

  • Kim, Dong-Youn;Kim, Su-Hyon;Lim, Young-Eun;Lee, Dong-Geol;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.20 no.3
    • /
    • pp.35-43
    • /
    • 2008
  • Purpose: We investigated the effect of isometric resistance exercise on the vastus medialis oblique muscle with inelastic tape and EMG biofeedback training applied to the patello-femoral joints of patients with patella malalignment. Methods: The 39 elderly subjects that had patella malalignment but no neuromuscular disorders were divided into a control group, taping group, and EMG biofeedback training group. Evaluations of function improvement performed before and after the treatment, as well as 4 weeks after treatment. Results: Change in pain in the knee joint were significantly different among groups (p<0.05). Maximum voluntary isometric contractility in the quadriceps muscle was significantly in the EMG biofeedback group (p<0.001). The WOMAC (Western Ontairo & McMaster Questionnaire) index showed a significant change (p<0.05) in pain, function, and total score. Taping and EMG biofeedback training showed a lasting effect until measurement 4 weeks after treatment. SF-36 (Medical outcome short form-36), which assesses the quality of life, did not significantly change. Conclusion: In osteoarthritis patients with a loss of patello-femoral joint function, isometric resistance exercise of the vastus medialis oblique muscle with taping seems effective.

  • PDF

Improvement of anti-corrosive property for alloy plated steel sheet by UV curable organic-inorganic hybrid coatings (합금도금강판 내식성 향상을 위한 UV 경화형 유무기 하이브리드 코팅)

  • Park, Jongwon;Lee, Kyunghwang;Na, Hyunju;Park, Byungkyu;Nam, Yeungsub;Hong, Shinhyub
    • Corrosion Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.27-33
    • /
    • 2013
  • According to its merits about high curing speed and low emission of volatile organic compounds, UV curable inorganic-organic coating technology has been developed as an alternative for toxic and carcinogenic chromate-based treatments for years. It is consistently observed that ultra-thin films offer excellent corrosion protection as well as paint adhesion to metals. Based on the tetra-ethylorthosilicate(TEOS) and methacryloxypropyl trimethoxysilane(MPTMS), inorganic sol was synthesized and formed hybrid networks with UV curable acrylic monomer, 6-hexanediol diacrylate(HDDA), trimethylolpropane triacrylate(TMPTA), pentaerylthritol triacrylate(PETA). Several methods were used to test their properties such as salt spray test, potentiodynamic measurement, tape peel test, etc. It was shown that anti-corrosive property and stability of storage were affected by the molecular ratios of inorganic and organic compounds. It was not only the stability of storage, but had a excellent anti-corrosive, paint adhesive, and anti-solvent properties in a final molar ratios of 0.6/0.04/0.86/0.005 (TEOS/MPTMS/Acetone/HNO3) and 0.08/0.106/0.081/0.02 (TMPTA/HDDA/PETA/photo initiator).

A Comparison of Effect between Wet Gauze with Cold Normal Saline and Wet Gauze with Cold Water on Postoperative Thirst, Oral Cavity Condition, and Saliva pH (생리식염수 냉수 거즈와 일반 냉수 거즈의 수술 후 갈증, 구강상태, 타액 산성도에 미치는 효과 비교)

  • Moon, Yang Hee;Lee, Yeon Hee;Jeong, Ihn Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.22 no.4
    • /
    • pp.398-405
    • /
    • 2015
  • Purpose: This study was aimed to compare the effect between wet gauze with cold normal saline and wet gauze with cold water on thirst, oral cavity condition, and saliva pH among postoperative patients. Methods: This study was a quasi-experimental study with 56 participants. The experimental group received wet gauze with cold normal saline, and control group received wet gauze with cold water for three times at 15 minute intervals. Data were collected using visual analog scale for thirst, oral assessment guide for oral cavity condition and acidity tape for saliva pH. Measurement were made before applying the gauze and at 15min, 30min, and 45min after applying gauze. Data were analyzed using repeated measured ANOVA. Results: Thirst, oral cavity condition, and saliva pH improved in both groups with increasing number of gauze application. Thirst for the experimental group improved more than for the control group (F=4.29, p=.009), oral cavity condition except saliva, and saliva pH were not significantly different between the groups. Conclusion: This study results indicated that nurses can apply wet gauze with cold normal saline to reduce thirst and saliva acidity, and to improve the oral cavity condition for postoperative patients.