• 제목/요약/키워드: Tailored RF

검색결과 14건 처리시간 0.023초

TAILORED RF PULSE를 이용한 NMR에서의 뇌 기능 영상법 (NMR Functional brain Imaging with the Tailored RF Pulse)

  • 노용만;조장회
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 춘계학술대회
    • /
    • pp.21-24
    • /
    • 1993
  • The experimental results of visual stimulation with the tailored RF pulse are reported. Tailored RF pulse is used for the susceptibility effect imaging. Around 25% signal change of visual cortex area is detected during photic stimulation. Interestingly, with the tailored RF pulse, the signal intensity of visual cortex is deceased during photic stimulation. It is, however, increased with normal $T_2$ weighted imaging. The comparison between normal $T_2$ weighted imaging and the tailored RF pulse imaging are performed with 4T NMR system and the results with human volunteer are also presented.

  • PDF

CGE와 TRFGE 기법으로 얻은 뇌기능 영상에서 혈류효과와 자화율 효과의 해석 (Analysis of Inflow and Susceptibility Effects in fMRI Obtained by CGE and TRFGE Techniques)

  • 노용만;정순철;조장희
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권4호
    • /
    • pp.431-438
    • /
    • 1995
  • Tailored RF 경사자계 영상법을 이용하여 혈류효과를 배제한 자화율 효과만의 뇌기능 영상을 얻을수 있었다. 일반적인 RF를 이용한 경사자계 뇌기능 영상법은 빠른 경사자계 영상법으로 인해 정맥뿐만 아니라 동맥에서의 혈류효과와 $T2^{*}$ 효과가 합쳐진 영상을 얻게되는 반면, tailored RF를 이용한 경사자계 영상법은 산소소모와 관계된 자화율 변화에 의한 뇌기능 영상을 얻을 수 있었다. 본 논문에서 tailored RF를 이용하여 뇌기능 영상에서 자화율효과와 혈류효과를 명확히 구분할 수 있음을 보였다. 그리고 실험결과로 얻은 신호는 충분히 크고 산소 소모의 변화를 보다 더 정확히 표현하므로 지금까지 다른 경사자계 영상법으로는 어려웠던 뇌기능 영상에서 정량화된 산소 신진대사 연구의 가능성을 보여주었다.

  • PDF

4.7T 고자장 초전도 자석에서 Tailored RF를 이용한 고양이 뇌의 자화율 강조영상법에 의한 자기공명혈관 조영술 (Susceptibility-Contrast-Enhanced MR Venography of Cat Brain Using Tailored RF Pulse at High Magnetic Field of 4.7 Tesla Superconducting Magnet)

  • 문치웅;김상태;이대근;임태환;노용만;조장희;이윤
    • 한국의학물리학회지:의학물리
    • /
    • 제5권1호
    • /
    • pp.55-66
    • /
    • 1994
  • 4.7T의 고자장 자기공명 영상(Magnetic Resonance imaging : MRI) 장치에서 Tailored RF 경사자계반향(Tailored RF Gradient-Echo : TRGE)기법을 이용하여 phantom 영상과 고양이 뇌의 정맥혈관 영상을 얻었다. 증류수에 MgCl$_2$를 섞어 T1을 짧게한 지름 6cm의 원통형 phantom으로 TRGE기법에 대한 검증을 먼저 하였다. 이후 halothane으로 전신 마취된 몸무게 3.0~4.0kg의 고양이 뇌로부터 얻은 시단면(sagittal slice) 영상에서 Dorsal sagittal sinus, Straight sinus, Vein of corpus callosum과 Internal cerebral vein등의 혈관이 강조되어 나타남을 고양이 뇌의 해부학적 그림과 비교해 보였다. Tailored RF 파형은 ASPECT 3000 computer(스위스 BRUKER사 제품)의 PASCAL 언어를 이용하여 제작하였다. 사각형의 절편모양(slice profile)과 원하는 절편의 두께(slice thickness)에 선택절편내에서 절편방향으로 위상분포가 최대 2$\pi$가 되는 bi-linear ramp 모양을 갖는 절편함수를 공간상에서 Fourier 변환시켜 Tailored RF를 만들었다. TR/TE=205/10 msec, 절편두께 TH=7mm, 화소배열수(matrix size)=256$\times$256, 평면해상도(in-plane resolution)=0.62$\times$0.31mm$^2$, 관심영역 크기(field of view : FOV)=8cm의 영상조건으로 자기공명 TRGE 영상을 얻었다.

  • PDF

Tailored RF 경자사계방향 (TRFGE} 자기공명영상(MRI)에서 유체에 의한 영상신호 변화 : 유체유입효과와 영상면내를 흐르는 유체의 효과에 대하여 (Flow Effects on Tailored RF Gradient Echo (TRFGE) Magnetic Resonance Imaging : In-flow and In-Plane Flow Effect)

  • 문치웅;김상태;노용만;임태환;조장희
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권3호
    • /
    • pp.243-251
    • /
    • 1997
  • 본 연구에서는 유체보상 경사자장 기법(flow-compensation-gradient of gradient-moment nulling method)을 이용하지 않은 Tailored RF를 이용한 TRFGE(tailored rf gradient echo) 영상에는 유체유입효과(in-flow effect)가 나타나지 않지만 절편(slice)내에서 판독경사자장(reading gradient)과 같은 방향으로 흐르는 유체는 신호가 강조가 됨을 이론과 실험으로 보였다. 절편 내에서 판독경사자장과 같은 방향으로 흐르는 유체의 신호가 TRFGE 영상에서 강조되는 이유를 이론적으로 설명하였으며 이 이론을 뒷받침 할 실험을 위해 유체 모형을 제작하였다. 원통 모양의 물 모형 중앙으로 유체 관을 통해 식염수(saline)가 주자장(B$B_0$)와 평행인 z 축 방향으로 흐를 수 있도록 하였다. 유체가 흐를 때와 흐르지 않을 때 CGE(conventional gradient echo) 영상과 TRFGE 영사을 얻어 각각 비교하였다. 유체 유입효과를 관찰하기 위해서는 횡단면(axial)의 영상을 얻었고 절편 내에서 판독경사자장과 같은 방향으로 흐르는 유체의 영상신호를 관찰하기 위해서 시상면(sagittal) 영상을 얻었다.

  • PDF

핵자기 공명 영상에서 새로운 유속 흐름제거 방법 (Novel Flow Suppression Technique in MRI)

  • 노용만;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.92-97
    • /
    • 1992
  • The pulsatile nature of blood flow makes artefacts in 2D Fourier transform image. Spatial presaturation is known to be effective in eliminating flow artefacts when the spin echo acquisition is employed. However. this method requires additional RF pulse and spoiling gradient for presaturation. In this paper a new flow saturation technique which does not require additional saturation-RF and gradient is proposed. The proposed technique is equivalent to the existing saturation technique but the elimination of the flow component is achieved by a pair of tailored $90^{\circ}-180^{\circ}$ RF pulses in tile spin echo sequence. By use of two tailored RF pulses with opposite phase polarity, a linear phase gradient is generated for those moving materials and consequently all the spins of moving materials become dephased thereby no signal is observable. Computer simulations and experimental results obtained using both a phantom and a human volunteer with a 2.0 T whole body system are also presented.

  • PDF

자기공명 Tailored-RF 경사자계반향영상법을 이용한 고양이 뇌에서의 First-Pass관찰 (First-Pass Observation using Tailored-RF Gradient Echo (TRFGE) MR Imaging in Cat Brain)

  • 문치웅;노용만
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권2호
    • /
    • pp.209-216
    • /
    • 1995
  • Recently, a new tailored RF gradient echo (TRFGE) sequence was reported. This technique not only enhances the magnetic susceptibility effect but also allows us to measure local changes in brain oxygenation. In this study, a phantom and cat brain experiments were performed on a 4.7 Tesla BIQSPEC (BRUKER) instrument with a 26 cm gradient system. We have demonstrated that the signal intensity (SI) of the TRFGE sequence varies according to the concentration of susceptibility contrast agent. Three capillary tubes with different concentrations of Gd-DTPA (0.01, 0.05, 0.1 mMOI/l) were placed at the middle of a cylindrical water phantom. Using both TRFGE and conventional gradient echo (CGE) sequences, phantom images of the slices which contain all three tubes were obtained. For the animal experiment, cats were anesthetized and ventilated using halotane (0.5%) and a $N_2O/ O_2$ mixture (2:1), and blood pressure and heart rate were monitored and kept normal. For the observation of tue first pass of Gd- DTPA, imaging was started at t = 0. At t = 8 ~ 12s, 0.2 mMol/Kg Gd-DTPA was manually injected in the femoral vein. The imaging parameters were TRITE = 25/10 msec, flip angle = $30^{\circ}$, FOV = 10cm, image matrix size = $128{\times}128$ with 64 phase encodings and the image data acquisition window was 10 msec. SI-time curves were then obtained from a series of 30 images which were collected at 2 sec intervals using both CGE and TRFGE pulse sequences before, during, and following the contrast injection.

  • PDF

MR Gradient Echo 영상술에서 자화율에 의한 에러의 감소에 관한 연구 (Reduction of Susceptibility Artifact in MR Gradient Echo Imaging)

  • 노용만;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1990년도 추계학술대회
    • /
    • pp.19-23
    • /
    • 1990
  • A new technique for reducing the susceptibility artifact in gradient echo imaging which uses a tailored RF pulse is proposed. It is applied to the case of imaging where artifacts and distortions arise due to the high local magnetic field inhomogeneity i. e., the susceptibility. The signal loss and void phenomena due to susceptibility in a voxel are studied and a correction method using a tailored RF pulse is proposed. Applications of this method in imaging are given and experimental results obtained using an human volunteer with a 2.0 T KAIS NMR system are presented.

  • PDF

A New Tailored Sinc Pulse and Its Use for Multiband Pulse Design

  • Park, Jinil;Park, Jang-Yeon
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권1호
    • /
    • pp.27-35
    • /
    • 2016
  • Purpose: Among RF pulses, a sinc pulse is typically used for slice selection due to its frequency-selective feature. When a sinc pulse is implemented in practice, it needs to be apodized to avoid truncation artifacts at the expense of broadening the transition region of the excited-band profile. Here a sinc pulse tailored by a new apodization function is proposed that produces a sharper transition region with well suppression of truncation artifacts in comparison with conventional tailored sinc pulses. A multiband pulse designed using this newly apodized sinc pulse is also suggested inheriting the better performance of the newly apodized sinc pulse. Materials and Methods: A new apodization function is introduced to taper a sinc pulse, playing a role to slightly shift the first zero-crossing of a tailored sinc pulse from the peak of the main lobe and thereby producing a narrower bandwidth as well as a sharper pass-band in the excitation profile. The newly apodized sinc pulse was also utilized to design a multiband pulse which inherits the performance of its constituent. Performances of the proposed sinc pulse and the multiband pulse generated with it were demonstrated by Bloch simulation and phantom imaging. Results: In both simulations and experiments, the newly apodized sinc pulse yielded a narrower bandwidth and a sharper transition of the pass-band profile with a desirable degree of side-lobe suppression than the commonly used Hanning-windowed sinc pulse. The multiband pulse designed using the newly apodized sinc pulse also showed the better performance in multi-slice excitation than the one designed with the Hanning-windowed sinc pulse. Conclusion: The new tailored sinc pulse proposed here provides a better performance in slice (or slab) selection than conventional tailored sinc pulses. Thanks to the availability of analytical expression, it can also be utilized for multiband pulse design with great flexibility and readiness in implementation, transferring its better performance.

핵자기 공명 단층 촬영에서의 자화율 강조 영상법 (Susceptibility Contrast Enhancement Imaging in MRI)

  • 노용만;문치웅;임태환;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.85-91
    • /
    • 1992
  • In MRI, an image contrast can be developed as a result of the susceptibility effect if an object has paramagnetic substances. This is mainly due to the non-uniform phase distribution or linear gradient developed by the magnetic susceptibility within a voxel, which in turn reduces the signal intensity; e.g., spin phases are dephased and thereby cancel each other resulting in a reduced signal. In this paper, a new concept for manipulating the susceptibility effect through the use of tailored RF pulses is proposed. As potential applications of the method, two different types of tailored RF pulses are introduced: one for susceptibility artifact correction and the other for contrast enhancement. The latter, for example, can be applied to angiography utilizing the paramagnetic property of deoxygenated blood. Both a theoretical study of the method and experimental results are reported.

  • PDF

Phase Dependent Image Contrast Enhancement in MRI

  • Y.M Ro;C. W. Mun;I. K. Hong
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권2호
    • /
    • pp.165-172
    • /
    • 1999
  • 본 연구에서는 MRI 영상에서 위상을 조절하여 영상 대조를 증가 시키는 방법을 제안 하였다 영상하고자 하는 물체 자체가 갖는 위상에 따라 영상의 대조가 변하기 때문에 본 방법은 자화율 영상이나 유속 영상에 유용하게 쓰일 수가 있다. 본 논문에서는 위상 분포에 따른 영상의 대조를 증가 시키기 위하여 RF 펄스를 복셀 내에서 위상을 갖도록 디자인 하였다. 따라서 복셀에서의 신호의 크기는 물체자체의 위상과 RF 펄스에의하여 가해준 위상이 결합에 의하여 결정된다. 외부위상 변화에 따른 신호의 변화를 분석하였고 그때 디자인된 RF 펄스를 이용하여 자화율만의 영상과 유속만의 영상을 얻었다. 컴퓨터 시뮬레이션의 결과는 제안된 알고리즘이 복셀내에 위상을 갖는 물체의 영상에 유용하고 그런 물체만을 영상하는데 유용함을 보였다.

  • PDF