• Title/Summary/Keyword: TVOC (Total Volatile Organic Compounds)

Search Result 53, Processing Time 0.027 seconds

Analysis on TVOC Concentrations and Influence Factors of Newly-Built Apartments (신축 아파트의 총휘발성유기화합물 농도와 관련요인 분석)

  • Choi, Yoon-Jung;Kang, Mi-Ra;Lee, Hye-Min;An, Hye-Jung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.268-271
    • /
    • 2006
  • The purpose of this study was to identify the influence of living factors on TVOC(Total Volatile Organic Compounds) concentrations for newly-built apartments. The field measurements of TVOC concentrations were made totally 30 times(5 times per one subject house) in six apartment units in which residents recently moved. Those apartments authorized its business approval before May 2004, the Act of Indoor Air auality Management for multi-use facilities. The findings were as follows: The TVOC concentrations of the measured subject apartments ranged from about 1/10 of the recommended standard for multi-use facilities($400{\mu}g/m^3$) to up to 90 times as high as the standard. Since then, the Recommended Standard of Indoor Air Quality Management for newly-built apartment house was announced in December 2005. In accordance with this standard($2390{\mu}g/m^3$) it ranged from about 1/100 to up to 15 times as high as the standard. The subject house whose TVOC concentrations reduced below the recommendation standard in the shortest period had the largest amount of ventilation (all the windows were open for ventilation in the past three months) among ail measured houses. The reason of another house whose TVOC concentrations were much higher than the rest was fronted with new furniture in the room. It's recommended that they should open all the windows for at least three months for ventilation in newly-built houses, and it would be better to avoid remodeling than needs be.

  • PDF

Analytical Studies on Volatile Organic Compounds from New Automotive Interior Parts (자동차 신차의 실내에서 발생되는 휘발성유기화합물 분석 연구)

  • Yun, Ju-Ho;Yoo, Seung-Eul;Kim, Sumin;Kim, Hyun-Joong;Kim, Seok-Man
    • Journal of Adhesion and Interface
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • The objectives of this study are to analyze emitted components and concentrations of VOCs (Volatile Organic Compounds) from the inside of vehicles that were experimented with sedans and RVs (Recreational Vehicles) delivered from warehouses after 15, 30, 45 and 60 days. The value of TVOC (Total Volatile Organic Compounds) was twice to eight times over than the standard value. However, TVOC of vehicles was more detected than RVs. Especially, the value of toluene was rapidly decreased after 45 days. But after 60 days, it was more detected than the standard value. After 45 days, the xylene value was confirmed to be lower than the standard value. As a result, it was found that development of alternative technologies such as non-solvent and systems for automobile interior parts may be imminent. Using test method standard, although it is not yet International Standard, to analyze and replace components, concentrations, human-noxious, it will contribute to producing environmental-friendly vehicles.

  • PDF

Scavenging Effect of Injurious VOC from Flooring using Green Tea Leaves Powder (녹차잎분말을 이용한 마루판의 유해 TVOC 제거효과)

  • Kang, Seog Goo;Lee, Hwa Hyoung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.49-58
    • /
    • 2008
  • This research was carried out to use green tea leaves powder for scavenging effects of volatile organic compounds on the UV varnishes and adhesives of fancy cherry veneer overlaid on the PF resin bonded Meranti plywood. The results are as follows: 1) Green tea leaves contained 9.85% of polyphenol compounds. 2) FT-IR results showed green tea leaves had effects to react with benzaldehyde and ethyl hexyl alcohol to form a chemical bond. 3) 2.5% of green tea leaves powder content was proper for scavenging effect on the UV varnishes and adhesives of fancy veneer overlaid on the PF resin bonded plywood 4) 20 liters small chamber test indicated excellent emission speed results such as $0.089mg/m^2hr$ of TVOC and $0.001mg/m^2hr$ of HCHO (on 7th day), as compared with standard (less than $0.1mg/m^2hr$ of TVOC and $0.015mg/m^2hr$ of HCHO emission are the excellent grade).

Characteristics for VOCs and aldehydes emission rates from architectural flooring (건축용 바닥재로부터의 VOCs와 Aldehydes 방출 특성)

  • Jang, Seong-Ki;Kim, Mi-Hyun;Seo, Soo-Yun;Lee, Woo-Suk;Lim, Jun-Ho;Lim, Jeong-Yun
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.544-552
    • /
    • 2006
  • Emission tests were carried out to investigate the characteristics of concentration according to flooring sort using small chamber method. The target Volatile Organic Compounds (VOC) included 27 individual compounds of environmental concern, which were determined by adsorption sampling and thermal desorption coupled with GC/MS method and by DNPH cartridge/HPLC method. The emission factor of Total Volatile Organic Compounds (TVOC) and Formaldehyde (HCHO) was detected $0.3mg/m^2{\cdot}h$ and $0.2mg/m^2{\cdot}h$ respectively, and the floorings of 37 (9 PVC Tile, 10 PVC Sheet, 18 Flooring) were satisfied emission standard. TVOC emission factor appeared in order of concentration of PVC Sheet, PVC Tile, and floor flooring, while HCHO was detected very high emission factor (as $0.4mg/m^2{\cdot}h$) at floor flooring above PVC series (as $0.001mg/m^2{\cdot}h$).

A study on measurement of VOCs in newly house (신축 공동주택의 VOCs 실태조사)

  • 유복희;윤정숙
    • Journal of the Korean housing association
    • /
    • v.13 no.5
    • /
    • pp.71-76
    • /
    • 2002
  • Recently, much attention has been paid to the problem such as sick building syndrome, which caused by the air pollutant indoor. In addition, Volatile Organic Compounds(VOCs) has been paid attention to as one of the main reason that causes air pollutant indoor, and the exposure of VOCs indoor is recognizes as an important factor which have an effect on the health of resident. In this study, measuring of VOCs in newly houses, and the results are as follows; 1)TVOC(Total Volatile Organic Compounds) indoor is detected high concentration(11314$\mu\textrm{g}$/㎤). 2)There are detected acetaldehyde, methylenechloride, benzene, trichloroethylene and styrene that have to take precaution against human carcinogenicity

Characteristics of TVOCs Emission Factors from Chemical and Natural Coating Materials (화학 및 천연페인트에서 발생되는 TVOCs의 방출강도 특성 연구)

  • Kim Shin Do;Kim Jeong Ho;Park Jin Soo;Lee Jeong Joo
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.487-492
    • /
    • 2004
  • Building materials are composed of very complex chemical compounds, and these indoor building materials discharge very much Volatile Organic Compounds(VOCs). We performed the environmental chamber test to investigate the Total VOCs(TVOCs) emission characteristics and emission factors about chemical and natural coating materials. As the result, we concluded that TVOCs emission are high at initial time and decreased in course of time. Natural paint was low emission level for TVOCs than chemical paint by small chamber test. The TVOCs emission factor-time profile showed a good fit with the results from the measured and predicted value.

Elimination Effect of Formaldehyde, Acetaldehyde and Total Volatile Organic Compounds from Car Felts using Nano-carbon Materials

  • Cho, Wan-Goo;Park, Seung-Gyu;Kim, Hyung-Man
    • Journal of the Korean Applied Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.38-44
    • /
    • 2009
  • We proposed the new nano-carbon ball (NCB) materials for eliminating the total volatile organic compounds(TVOCs) from the felt which is built in the car. The concentrations of acetaldehyde and formaldehyde of the original felts were varied upon the different production lots. Acetaldehyde in the felt can be eliminated to target level($0.2{\mu}g$) after introducing 0.5 wt% of NCB into the felt. Detector tube method for analyzing formaldehyde gas was more accurate than HPLC method. Formaldehyde can be eliminated to target level (64 ppb) after introducing 0.5 wt% of NCB into the felt. We also found that TVOC can be reduced to target level ($0.32{\mu}g$) after introducing 2.0 wt% of NCB. Upon introducing small amounts of NCB into the felt, it was possible that the level of formaldehyde, acetaldehyde and TVOC formed from the felts can be reduced to the target level. We also suggest the effective analyzing method of TVOCs.

The Temporal and Spatial Distribution of Volatile Organic Compounds(VOCs) in the Urban Residential Atmosphere of Seoul, Korea

  • Anthwal, Ashish;Park, Chan-Goo;Jung, Kweon;Kim, Min-Young;Kim, Ki-Hyun
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.1
    • /
    • pp.42-54
    • /
    • 2010
  • Automobile emissions have caused a major hydrocarbon pollution problem in the ambient air of many cities around the world. This study was conducted to measure the pollution status of volatile organic compounds (VOCs) in some urban residential areas in Seoul, Korea. A total of 20 VOCs (11 aromatic and 9 chlorinated species) were identified at 4 urban residential sites in Seoul, Korea from February 2009 to July 2009. Comparison of total VOC (TVOC) concentration data indicated the dominance of the aromatic species with the maximum (72.2 ppbC) at Jong Ro (JR) and the minimum at Yang Jae (33.4 ppbC). The peak concentration of TVOC occurred during spring at all sites with an exception at Gang Seo (GS), where it was recorded during winter. The distribution of individual VOCs at the study sites was characterized by high toluene concentration. A strong correlation of benzene was also observed with other VOCs and criteria pollutants at all sites (except YJ). The overall results of this study suggest that vehicular emissions have greatly contributed to the increase in VOC pollution at all the study sites.

Extension Possibility of Indoor Air Standards in Office Building by Health Risk Assessment (건강위해성평가에 의한 사무실 실내공기오염물질의 관리항목 확대)

  • Roh, Young-Man;Lee, Cheol Min;Kim, Yoon Shin;Kim, Seok Won;Kim, Chi-Nyon;Kim, Hyun-Wook;Cho, Kee Hong;Choi, Ho Chun;Kim, Jung Man
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.1
    • /
    • pp.54-67
    • /
    • 2006
  • This study was performed to deduct the extension possibility of the standards establishment for $NO_2$, $O_3$, Asbestos, Radon, total volatile organic compounds (TVOC) excluded in the indoor air part of Industrial Safety Acts in Korea. The air pollutants were sampled for 30 office buildings from August to September, 2005 in the metropolitan area. The airborne concentrations of $NO_2$, $O_3$, Radon and TVOC were 0.0092 ppm, 0.0035 ppm, 0.57 pCi/L and $423{\mu}g/m^3$, respectively. The management plan and reduction methods is required in the aspect of indoor air quality(IAQ) because the emission sources of those also exist in indoor as well as outdoor even though those were not exceeded the standards of the Ministry of Environment in Korea. The standard for TVOC in the new and remodeling office has to be established based on the risk assessment when hazard index exceeded "1" in the worst case scenario. In the state of art, the management of each volatile organic compounds has a difficulty due to not enough data for toxicological reference. Therefore, it is suggested that first of all, the standard for TVOC be established and then expanded to each materials for decision-making of improvement of IAQ in office.

Influence of Surface Finishing Material Types to Formaldehyde and Volatile Organic Compounds Emission from Plywood

  • Kim, Ki-Wook;Oh, Jin-Kyoung;Lee, Byoung-Ho;Kim, Hyun-Joong;Lee, Young-Kyu;Kim, Sung-Hun;Kim, Gwan-Eui
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.39-45
    • /
    • 2008
  • Formaldehyde and volatile organic compounds (VOCs) are emitted from wood-based panels that have been made using wood particles, wood fiber, wood chips, formaldehyde-based resins and so on. In this study, we examined formaldehyde and total VOCs (TVOC) emission behaviors for plywood overlaid with water-soluble phenolic resin impregnated linerboard (PL), and two kinds of surface materials (decorative veneer and pre-impregnated finishing foil) that were adhered onto the PL that named DPL and PPL. EVA (ethyl vinyl acetate) was used to overlay the decorative veneer and pre-impregnated finishing foil on the plywood with water-soluble phenolic resin impregnated linerboard by a hot press instrument. The debonding test and accelerated aging test were conducted to assess their mechanical properties. Formaldehyde and TVOC emission concentrations were measured using the FLEC method and a VOC Analyzer, respectively. The debonding test results of PL, DPL and PPL were 1.2, 1.5, and $0.5N/mm^2$, respectively. The surface appearance of the samples were not changed after the accelerated aging test. The PL and DPL exhibited reduced formaldehyde and TVOC emission levels, respectively. In the case of PPL, the VOC value was relatively higher than those of PL and DPL.