Study on the Fire Resistance Performance of the TSC Beam (TSC 합성보의 내화성능에 관한 연구)

  • Kim, Sung Bae;Choi, Seng Kwan;Lee, Chang Nam;Kim, Sang Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.1
    • /
    • pp.113-122
    • /
    • 2006
  • The purpose of this paper is to evaluate the fire resistance of the TSC beam, a composite beam composed of a concrete beam enclosed by steel plates. Since a discrepancy was observed between the structural mechanisms of TSC and typical composite beams, the fire performances of the two beams are likewise believed to be partially dissimilar. In this experiment, small and medium-sized TSC beams were tested under given conditions in the laboratory, with/without one of the most widely used spray-on fire protections in Korea. Furthermore, based on the steel and concrete properties under elevated temperatures that were obtained from Eurocode, temperature development across the section was suggested, analyses. To determine the capacity of a modified plastic section, th e fire performance of the model was also examined.

Cyclic Loading Test for TSC Beam - PSRC Column Connections (TSC 합성보 - PSRC 합성기둥 접합부에 대한 주기하중 실험)

  • Hwang, Hyeon Jong;Eom, Tae Sung;Park, Hong Gun;Lee, Chang Nam;Kim, Hyoung Seop
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.6
    • /
    • pp.601-612
    • /
    • 2013
  • In the present study, details of the TSC beam-to-PSRC column connection for low and middle seismic zones were developed. For ease construction, the top and bottom flanges of the steel section of the TSC beam were discontinuous at the joint face on purpose, while the web passes through the joint. Thus, tensile resistance of the top and bottom flanges is not considered in the calculation of nominal strength of the connection. Cyclic loading tests on two interior connections and an exterior connection were performed to verify the seismic performance. The test parameter for two interior connections was the depth of the TSC beams: 600 and 700 mm including the slab depth. The test results showed that the nominal strength of the connections predicted by KBC 2009 correlated well with the test results. The connection specimens exhibited relatively good deformation and energy dissipation capacities, greater than the requirements for the ordinary and intermediate moment frames. Ultimately, the connection specimens were failed at the story drift ratios of 3.0 to 4.0 % due to local buckling and tensile fracture of the web of the TSC beam passing through the joint. By modifying the existing provisions of ASCE, the joint shear strength of the TSC beam-PSRC column connection was evaluated.

Thermally stimulated current analysis of (Ba,SR)TiO₃ capacitor ((Ba,Sr)TiO₃ 커패시터의 thermally stimulated current 분석)

  • Lee, Gi Seon;Seo, Gwang Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.5
    • /
    • pp.17-17
    • /
    • 2001
  • 고유전 (Ba, Sr)TiO₃ (BST) 박막을 이용한 DRAM storage capacitor의 저전계 영역에서의 전하손실을 발생시키는 커패시터의 누설전류는 유전완화전류와 진성 누설전류로 이루진다고 알려져 있다. 특히, 기가급 DRAM의 동작 전압(~IV)에서 유전완화전류가 진성 누설전류에 비해 훨씬 크기 때문에 이에 대한 심도 있는 연구가 필요하다. 본 연구에서는 thermally stimulated current (TSC) 측정법을 BST 박막에 처음으로 적용하여 트랩의 에너지 level 및 공정변화에 따른 트랩 밀도의 상대적 평가를 하였다. 그리고, 기존에 사용되던 전류-전압(I-V) 측정이나 전류-시간(I-t) 측정과 비교 및 분석함으로써 유전완화 전류의 원인을 규명하고 TSC 측정법의 신뢰성을 살펴보았다. 먼저 안정적인 TSC 측정을 위해 전계, 시간, 온도 및 승온속도에 따른 polarization condition을 알아보았다 이 조건을 이용한 TSC 측정으로부터 BST 박막에서의 트랩의 energy level이 0.20(±0.01) eV와 0.45(±0.02) eV임을 알 수 있었다. Rapid thermal annealing (RTA)을 이용한 후속 열처리에 따른 TSC 측정을 통하여 이 트랩들이 산소결핍(oxygen vacancy)에 기인함을 확인할 수 있었다. MIM BST 커패시터의 열처리에 대한 TSC 특성은 전류-전압(I-V) 및 전류-시간(I-t) 특성과 같은 경향성을 보인다. 이것은 TSC 측정이 BST 박막내의 트랩을 평가하는데 있어서 매우 효과적인 방법이라는 것을 보여준다.

An Experimental Study on the Behavior of the T-type Steel Composite Beam (단순지지 T형 합성보의 휨거동에 관한 실험적 연구)

  • Kim, Sang Seup;Kim, Sang Mo;Kim, Sung Bae;Seo, Dong Gee;Kim, Kyu Suk
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.2 s.69
    • /
    • pp.225-233
    • /
    • 2004
  • Composite action is generally achieved by providing shear connections between steel top flange and concrete topping. Composite sections have greater stiffness than the summation of the individual stiffness of slab and beam. Therefore, they can carry larger loads or similar loads with appreciably smaller deflection and are less prone to transient vibration. T-type Steel Composite beam (TSC-beam) was developed to increase these advantages. Ten specimens were tested for this study. During the experiment, crack pattern and deflection of beam were investigated. The examined results of TSC beam system were compared with results from the typical composite beam and RC beam.

Thermally Stimulated Current Analysis of (Ba, Sr)TiO$_3$ Capacitor ((Ba, Sr)TiO$_3$ 커패시터의 Thermally Stimulated Current분석)

  • Kim, Yong-Ju;Cha, Seon-Yong;Lee, Hui-Cheol;Lee, Gi-Seon;Seo, Gwang-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.5
    • /
    • pp.329-337
    • /
    • 2001
  • It has been known that the leakage current in the low field region consists of the dielectric relaxation current and intrinsic leakage current, which cause the charge loss in dynamic random access memory (DRAM) storage capacitor using (Ba,Sr)TiO$_{3}$ (BST) thin film. Especially, the dielectric relaxation current should be seriously considered since its magnitude is much larger than that of the intrinsic leakage current in giga-bit DRAM operation voltage (~IY). In this study, thermally stimulated current (TSC) measurement was at first applied to investigate the activation energy of traps and relative evaluation of the density of traps according to process change. And, through comparing TSC to early methods of I-V or I-t measurement and analyzing, we identify the origin of the dielectric relaxation current and investigate the reliability of TSC measurement. First, the polarization condition such as electric field, time, temperature and heating rate was investigated for reliable TSC measurement. From the TSC measurement, the energy level of traps in the BST thin film has been investigated and evaluated to be 0.20($\pm$0.01) eV and 0.45($\pm$0.02) eV. Based on the TSC measurement results before and after rapid thermal annealing (RTA) process, oxygen vacancy is concluded to be the origin of the traps. TSC characteristics with thermal annealing in the MIM BST capacitor have shown the same trends with the current-voltage (I-V) and current-time (I-t) characteristics. This means that the TSC measurement is one of the effective methods to characterize the traps in the BST thin film.

  • PDF

Study on the Fire Behaviour of Composite Beam with Loading and Unloading (하중재하 영향에 의한 합성보의 화재거동에 관한 연구)

  • Kim, Sung-Bae;Lee, Chang-Nam;Kim, Woo-Chul;Kim, Sang-Seup
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.27-35
    • /
    • 2009
  • In this study, the fire resistance performance of a simple support composite beam, which was sprayed with fire protection coatings, was evaluated. Primary valuables of the study are loading and unloading, shape of composite beam and metal lath of the web. The thickness of the fire protection coating to the three hour resistance is 40mm, but the fire resistance test was performed with 25mm coatings. The test result showed that TSC composit beams with 25mm fire protection coatings can resist on fire for three hours at the both loading and unloading tests. Average and maximum temperatures were less than $250^{\circ}C$ and $310^{\circ}C$ respectively, compared with the standard temperatures for fire resistance on the loading and unloading tests.

Tuberous Sclerosis Complex with Crohn's Disease (크론병과 병발한 결절성경화증 1예)

  • Kim, Min Hee;Lee, Yoon Jin;Kim, Jae Young;Yi, Yoon Young;Kang, Joon Won
    • Journal of the Korean Child Neurology Society
    • /
    • v.26 no.4
    • /
    • pp.284-287
    • /
    • 2018
  • Tuberous sclerosis complex (TSC) is an autosomal dominant disorder caused by mutation of one of two genes, TSC1 (encoding hamartin, 9q34) and TSC2 (encoding tuberin, 16p13). It invades the central nervous system and various parts of the body, causing various symptoms. Crohn's disease (CD) is a chronic immune-mediated disease that has not been clearly elucidated. It is thought to be caused by an excessive immune response of the body to bacteria that normally exist in the digestive tract with genetic factors. No cases have been reported in which both of the above-mentioned diseases occurred simultaneously. We report a case of CD in a patient with TSC. A 12-year-old boy was brought to our hospital because of abdominal pain. Skin lesions were observed in the TSC. Fundus examination revealed a hamartoma in the right retina. Brain magnetic resonance imaging revealed a subendothelial giant cell astrocytoma (SEGA). On the basis of these findings, he was diagnosed as having TSC. Blood test results showed increased levels of inflammatory markers. On abdominal ultrasonography, his colon walls were observed to be thickened with increased vascularity of the proximal ascending colon, ileocecal valve, and terminal ileum. Colonoscopy revealed discontinuous ulcerations and inflammations of the ileum, IC valve, and cecum, similar to those found in CD. Everolimus was administered orally for the SEGA but was discontinued frequently owing to the exacerbation of CD. The possibility of CD should be kept in mind in patients with TSC considering to undergo treatment for SEGA.

A Study on the strength evaluation for T-type Composite Beam (T형 합성보의 내력평가에 관한 연구)

  • Kim, Sang Mo;Kim, Kyu Suk
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.4 s.65
    • /
    • pp.467-474
    • /
    • 2003
  • Composite action can be achieved by providing shear connectors between the steel top flange and concrete topping. Composite sections are stiffer than the sum of the individual stiffness of slab and beam. They can therefore carry heavier loads or similar loads with appreciably smaller deflection. They are also less prone to transient vibration. In this study, T-type Steel Composite beam (TSC-beam) was developed and tested. The test results of TSC beam were compared with the theoretical results based on composite actions.

Validation of the Korean Version of the Trauma Symptom Checklist-40 among Psychiatric Outpatients (정신건강의학과 외래환자 대상 한국판 외상 증상 체크리스트(Trauma Symptom Checklist-40)의 타당도 연구)

  • Park, Jin;Kim, Daeho;Kim, Eunkyung;Kim, Seokhyun;Yun, Mirim
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.26 no.1
    • /
    • pp.35-43
    • /
    • 2018
  • Objectives : Effects of multiple trauma are complex and extend beyond core PTSD symptoms. However, few psychological instruments for trauma assessment address this issue of symptom complexity. The Trauma Symptom Checklist-40 (TSC-40) is a self-report scale that assesses wide range of symptoms associated with childhood or adult traumatic experience. The purpose of the present study was to evaluate the validity of the Korean Version of the TSC-40 in a sample of psychiatric outpatients. Methods : Data of 367 treatment-seeking patients with DSM-IV diagnoses were obtained from an outpatient department of psychiatric unit at a university hospital. The diagnoses were anxiety disorder, posttraumatic stress disorder, depressive disorder, adjustment disorder and others. Included in the psychometric data were the TSC-40, the Life events checklist, the Impact of Event Scale-Revised, the Zung's Self-report Depression Scale, and the Zung's Self-report Anxiety Scale. Cronbach's ${\alpha}$ for internal consistency were calculated. Convergent and concurrent validity was approached with correlation between the TSC-40 and other scales (PTSD, anxiety and depression). Results : Exploratory factor analysis of the Korean Version of TSC-40 extracted seven-factor structure accounted for 59.55% of total variance that was contextually similar to a six-factor structure and five-factor structure of the original English version. The Korean Version of TSC-40 demonstrated a high level of internal consistency. (Cronbach's ${\alpha}=0.94$) and good concurrent and convergent validity with another PTSD scale and anxiety and depression scales. Conclusions : Excellent construct validity of The Korean Version of TSC-40 was proved in this study. And subtle difference in the factor structure may reflect the cultural issues and the sample characteristics such as heterogeneous clinical population (including non-trauma related disorders) and outpatient status. Overall, this study demonstrated that the Korean version of TSC-40 is psychometrically sound and can be used for Korean clinical population.