• Title/Summary/Keyword: TRV

Search Result 61, Processing Time 0.028 seconds

Analysis on the Effects of TRV and MOV in Real System with TCSC (TCSC가 적용된 실계통 시스템에서의 TRV와 MOV의 영향에 대한 분석)

  • Lee, Seok-Ju
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.2
    • /
    • pp.41-46
    • /
    • 2019
  • The application of series compensator in a power system affects other devices such as circuit breakers transient recovery voltage (TRV) problem. In this paper, we analyze the TRV effect on a line circuit breaker in the cases with and without thyristor-controlled series capacitor (TCSC) via simulation, and suggest an effective method to overcome the increase of TRV due to the TCSC installation. It also discusses the impact of proposed protection on metal oxide varistor (MOV). A 345 kV transmission line in Korea was selected as a study case. Grid system was modelled using PSCAD (Power Systems Computer Aided Design) / EMTDC(Electro Magnetic Transient Direct Current). The TRV was analyzed by implementing a short circuit fault along the transmission line and at the breaker terminal. The proposed protection scheme, the TRV satisfies the standard. However, the MOV energy capacity increased as the delay time increased. This result can solve the TRV problem caused by the expected transmission line fault in a practical power system.

TRV Pattern Classification and Parameter Calculation Method for Double-Frequency Synthetic Test Circuit (2중주파 합성시험회로의 TRV 패턴 분류 및 파라미터 계산 방법)

  • Lee Yong Han
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.587-589
    • /
    • 2004
  • In this paper analytical pattern classification of TRV waves created by double-frequency synthetic test circuit was proposed. According to the classified patterns of the TRV wave, calculation methods of 3 reference lines and 4 parameters characterizing the TRV wave wire proposed. These methods can be utilized to optimize test facility and to standardize test quality.

  • PDF

Characterization of Tobacco rattle virus(TRV-K) isolated in Korea (한국에서 분리한 Tobacco rattle virus(TRV-K)의 특성)

  • Shin, Hye-Houng;Koo, Bong-Jin;Kang, Sang-Gu;Chang, Moo-Ung;Ryu, Ki-Hyung
    • Research in Plant Disease
    • /
    • v.8 no.4
    • /
    • pp.207-214
    • /
    • 2002
  • Tobacco rattle virus(TRV) was detected from Gladiolus hybridus, Crocus spp. and Narcissus spp. leaves show-ing notched or stripe on the leaf and malformation symptoms collected from Daegu and Kyungbuk province by electron microscopy (EM), immunosorbent electron microscopy (ISEM) and host range study. Direct negative staining method by EM showed rigid rod long particles 170~200$\times$22 nm and rigid rod short particles 40~114$\times$22 m. TRV-K isolated from G. hybridus propagated with Nicotiana tabacum. TRV coat protein(CP) gene was amplified using specific oligonucleotide primer by RT-PCR. Sequence analysis of amplified CP gene showed 99.5% nucleotide similarity to TRV-ORY.

The Viruses in Gladiolus hybridus cultivated in Korea 2. Broad Bean Wilt Virus, Cucumber Mosaic Virus and Tobacco Rattle Virus (한국산 글라디올러스에 발생하는 바이러스)

  • 박인숙;김규원;권현정;장무웅
    • Korean Journal Plant Pathology
    • /
    • v.14 no.1
    • /
    • pp.83-91
    • /
    • 1998
  • Gladioli (Gladiolus hybridus) showing flower colour breaking leaf mosaics, notched leaf, and dwarfing or lack of visible symptoms were collected from gladioli growing areas in Taegu and Kyungpook province, Korea. The three viruses isolated from the naturally infected gladioli were identified as broad bean wilt virus (BBWV), cucumber mosaic virus (CMV), and tobacco rattle virus (TRV) by their host range, immunosorbent electron microscopy (ISEM), enzyme-linked immunosorbent assay (ELISA), direct tissue blotting immunoassay (DTBIA), and intracellural symptoms. By DTBIA and ISEM, TRV was detected in gladiolus showing notched leaf, while CMV was frequently detected in gladioli with dwarfing, color breaking and malformation of flowers. BBWV was also often detected in many symptomless gladiolus plants, but TRV was detected in notched-leaf of gladiolus. Electron microcopic examination of negatively stained preparations showed that BBWV and CMV are spherical particles of 28 nm and 30 nm in diameter, and TRV is rigid rod-shaped particles of 40∼200 nm in length. The rigid rodshaped virus particles reacted positively with TRV antiserum in ISEM and DTBIA, respectively.

  • PDF

Analysis of a TRV influence according to application position of a SFCL (초전도 한류기 투입 위치에 따른 TRV 영향 분석)

  • Bang, Seung-Hyun;Rhee, Sang-Bong;Kim, Chul-Hwan;Kim, Jae-Chul;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.91-92
    • /
    • 2008
  • The rating of a circuit breaker depends not only on the interrupting current but also on a transient recovery voltage (TRV). To achieve a successful interruption, the circuit breaker must withstand the TRV. A superconducting fault current limiter (SFCL) is a device that limits the fault current fast and effectively without having high impedance during normal operation of the power system. Therefore, we studied the influence of the TRV according to the application of a resistive type SFCL in distribution system. This paper analyses the influence of the TRV for various application position of the resistive SFCL. The distribution system and the resistive SFCL were modeled by using EMTP-RV (Electromagnetic Transient Program - Restructured Version)

  • PDF

TRV Analysis for AC Filter Circuit Breaker in HVDC System (HVDC시스템에서 AC 필터 차단기의 TRV해석)

  • Kim, Chan-Ki;Kim, Jin-Young;Sin, Jin-Chul
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.4
    • /
    • pp.369-374
    • /
    • 2015
  • The circuit breaker in an electric power system is not operated when the voltage in the circuit breaker is higher than the rated transient recovery voltage (TRV). The TRV of a circuit breaker is characterized by re-ignition of the arc between two poles and determined by the value of connecting impedance. In this study, we simulated the peak value of TRV in the AC filter of the circuit breaker. The suitability of TRV is assessed by capacitive current switching test conditions defined by the international guide IEC62271-100.

A Study on the Circuit Breaker Transient Recovery Voltages on Large Commercial Customer using EMTP-RV Program (EMTP-RV를 이용한 대용량 전기설비의 차단기 TRV에 관한 연구)

  • Cho, Kyeh-Sool;Choi, Hong-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.59-66
    • /
    • 2011
  • In electric power system, the circuit breaker is not operated when the higher voltage then the rated TRV(transient Recovery Voltage) appeared in the circuit breaking, The TRV of a circuit breaker means the characteristics of reignition by the arc between two poles. and is decided by the value of connecting Impedance. In this paper we of carried out many kinds of experiments varying the types of bus, the types of installation, the length of installation between 22.9 [kV] level circuit breaker and MTR in general 154/22.9[kV] system, We also simulated the characteristics of TRV using EMTP-RV program. The suitability of TRV in assessed by Uc, RRRV(Rate of Rise of Recovery Voltage) which are defined by the international guide, IEC62271-100. The values of RRRV gained from the cable-made bus are 590[%] lesser than those from the NSPB-made bus respectively. So the triangled type is more rational in the aspect of TRV.

A study on TRV generating circuit in short-circuit tests (단락시험에서의 과도회복전압발생회로에 관한 연구)

  • Kim, Maeng-Hyun;Suh, Yoon-Teak;Yoon, Hack-Dong;Kang, Young-Sik;Kho, Hee-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.134-136
    • /
    • 2000
  • This paper deals with the analysis on the TRV generating circuit and the TRV waveform occurred from the short-circuit tests using only the short-circuit generator. And the results of analysis on the proposed TRV generating circuit and TRV measured are described.

  • PDF

The prospective TRV analysis of 345KV transmission system (345 KV 송전계통의 고유 TRV 해석)

  • Yoon, Jae-Young;Jung, Wee-Sik;Park, Dong-Wook;Min, Suk-Won;Jung, Sang-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.397-400
    • /
    • 1989
  • The interrupting capability of circuit breaker to have an effect on stability and reliability of the power system is largely determined by the fault current and prospective TRV (prospective transient recovery voltage). The prospective TRV, which is essentially a system function determined by the elements of the connected circuit, is not constant for a given system location but is affected by a number of variables. Therefore, the purpose of this study is to analyze the prospective TRV of KEPCO's 345KV transmission system by using EMTP (Electro-Magnetic Transients Program) and to compare the calculated values with the standard values in KSB 150 (1976)

  • PDF

A Study on the TRV(SLF) of Circuit Breakers According to Install Current Limit Reactors (345kV 고장전류 저감을 위한 한류리액터 설치시 차단기 TRV(근거리 고장시) 검토)

  • Park, H.S.;Kwak, J.S.;Ju, H.J.;Ryu, H.Y.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.371-373
    • /
    • 2005
  • An enhancement for a transmission and substation equipment in power system make the system impedance to be lower. In principle, if the system impedance become low, system stability will be better, but the fault current become very higher. It is a very big problem for CB operating. As a fact of CB operating performance, high amplitude of the fault current may cause CB operation failure because of exceeding standard value in TRV. So we simulated TRV by using the EMTP. Generally there are two types of TRV in actual power system. One is short line fault, the other is bus terminal fault. In this paper, we simulated the TRv at short line fault as installed current limit reactors to reduce fault current in 345kV ultra-high voltage system. Short line fault is caused from single line fault in transmission line.

  • PDF