• Title/Summary/Keyword: TRS

Search Result 239, Processing Time 0.023 seconds

Functional Analysis between LTE-Railway and Public Safety-LTE (LTE 기반 철도통합망(LTE-R)과 재난통신망(PS-LTE)의 기능 분석)

  • Kim, Yong-Kyu;Yoon, Yong-Gi;Kim, Ju-Youp;Song, Yong-Soo;Choi, Sang-Won
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.1
    • /
    • pp.20-30
    • /
    • 2017
  • Due to the evolution of wireless communications technology, Long Term Evolution (LTE), which is a $4^{th}$ generation mobile communications system, has been adopted as a railway communications system. This LTE Railway (LTE-R) system is composed of various elemental functions, which are largely categorized into public safety and wireless communications for train control. Research on the public safety functions of railway communications have their roots in TRS based national public safety communication systems, and research on wireless communications functions for train control have their roots GSM-R, which is utilized by the ETCS in Europe. Based on these circumstances, this paper first analyzes the requirements for developing public safety technology in LTE-R, and compares those requirements with the functions of public safety LTE (PS-LTE), which is being deployed for the first time in the world by the South Korean government. Based on an analysis of the common and specific functions of LTE-R and PS-LTE, we conclude that there is little problem in integrating LTE-R and PS-LTE from the perspective of functionality. Second, this paper provides a comparison of the LTE-R requirements for the Quality of Service (QoS) with those of GSM-R utilized by the ETCS. This offers a guideline to allow LTE-R to be applied to a 500km/h train control system.

Characteristics of Groundwater Quality by Elevation in Cheju Island (고도에 따른 제주도 지하수의 수질특성)

  • 이용두
    • Journal of Korea Soil Environment Society
    • /
    • v.5 no.3
    • /
    • pp.65-75
    • /
    • 2001
  • This study purpose to elucidate the characteristics of water quality by elevation and groundwater samples has been studied with the samples from 150 selected groundwater represented the watershed of groundwater wells in Cheju Island. The evaluation of the characteristics of water quality utilized the physical and chemical property and the statistical analysis. According to the piper diagram, groundwater in the under 50 m region is shown N $a^{+}$$K^{+}$-C $l^{[-10]}$ type, and that groundwater in the 50~100 m region is shown N $a^{+}$$K^{+}$-HC $O_3$$^{[-10]}$ +C $O_3$$^{2-}$ type. and partly N $a^{+}$$K^{+}$-C $l^{[-10]}$ type. In the above 100 m region belongs to N $a^{+}$$K^{+}$-HC $O_3$$^{[-10]}$ +C $O_3$$^{2-}$ type. The result of factor analysis, commonly two factors as TDS(Total Dissolved Solid) and the contaminants extracted in the under 50m region and above 100 m region. Three factors were obtained from the result of the factor analysis in the 50~100 m region. Factor 1, consisting of TRS content. Factor 2, consisting of the contaminant and the dissolution of minerals. and Factor 3, consisting of HC $O_3$$^{[-10]}$ content. content.

  • PDF

Study on Characteristics of Dose Distribution in Tissue of High Energy Electron Beam for Radiation Therapy (방사선 치료용 고에너지 전자선의 조직 내 선량분포 특성에 관한 연구)

  • Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.175-186
    • /
    • 2002
  • The purpose of this study is directly measure and evaluate about absorbed dose change according to nominal energy and electron cone or medical accelerator on isodose curve, percentage depth dose, contaminated X-ray, inhomogeneous tissue, oblique surface and irradiation on intracavitary that electron beam with high energy distributed in tissue, and it settled standard data of hish energy electron beam treatment, and offer to exactly data for new dote distribution modeling study based on experimental resuls and theory. Electron beam with hish energy of $6{\sim}20$ MeV is used that generated from medical linear accelerator (Clinac 2100C/D, Varian) for the experiment, andwater phantom and Farmer chamber md Markus chamber und for absorbe d dose measurement of electron beam, and standard absorbed dose is calculated by standard measurements of International Atomic Energy Agency(IAEA) TRS 277. Dose analyzer (700i dose distribution analyzer, Wellhofer), film (X-OmatV, Kodak), external cone, intracavitary cone, cork, animal compact bone and air were used for don distribution measurement. As the results of absorbed dose ratio increased while irradiation field was increased, it appeared maximum at some irradiation field size and decreased though irradiation field size was more increased, and it decreased greatly while energy of electron beam was increased, and scattered dose on wall of electron cone was the cause. In percentage depth dose curve of electron beam, Effective depth dose(R80) for nominal energy of 6, 9, 12, 16 and 20 MeV are 1.85, 2.93, 4.07, 5.37 and 6.53 cm respectively, which seems to be one third of electron beam energy (MeV). Contaminated X-ray was generated from interaction between electron beam with high energy and material, and it was about $0.3{\sim}2.3\%$ of maximum dose and increased with increasing energy. Change of depth dose ratio of electron beam was compared with theory by Monte Carlo simulation, and calculation and measured value by Pencil beam model reciprocally, and percentage depth dose and measured value by Pencil beam were agreed almost, however, there were a little lack on build up area and error increased in pendulum and multi treatment since there was no contaminated X-ray part. Percentage depth dose calculated by Monte Carlo simulation appeared to be less from all part except maximum dose area from the curve. The change of percentage depth dose by inhomogeneous tissue, maximum range after penetration the 1 cm bone was moved 1 cm toward to surface then polystyrene phantom. In case of 1 cm and 2 cm cork, it was moved 0.5 cm and 1 cm toward to depth, respectively. In case of air, practical range was extended toward depth without energy loss. Irradiation on intracavitary is using straight and beveled type cones of 2.5, 3.0, 3.5 $cm{\phi}$, and maximum and effective $80\%$ dose depth increases while electron beam energy and size of electron cone increase. In case of contaminated X-ray, as the energy increase, straight type cones were more highly appeared then beveled type. The output factor of intracavitary small field electron cone was $15{\sim}86\%$ of standard external electron cone($15{\times}15cm^2$) and straight type was slightly higher then beveled type.

  • PDF

Evaluation for the Introduction Impact of an Integrated Railway Wireless Network : A Case Study of the Wonju-Gangneung Rail Line (철도통합무선통신망 도입효과의 평가 -원주-강릉구간에 대한 사례를 중심으로-)

  • Cho, Hanbyeog;Jang, Jeong Ah;Jo, Chang-hee;Yun, Hak-Sun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.4
    • /
    • pp.129-142
    • /
    • 2016
  • This study performs an evaluation, using the economic feasibility analysis method, of the LTE based railway wireless networks (LTE-R) service that is planned to be used for the future railway networks in Korea. Its objectives are using the evaluation results and working to reflect the factors that lead to a maximization of benefits in designing an integrated railway wireless network. This study analyzes the impact of implementing an LTE-R on the railway networks, in contrast to the existing wireless network methods, e.g. VHR and TRS to new rail lines on an economic view. This results found that the benefit cost ratio is greater than 1.0 with a 10% contribution to benefits of the wireless network service in the case study on the Wonju-Gangneung rail line that will start operations in 2018; as a result, an ICT design is desired. For the introduction of an LTE-R service for the Wonju-Gangneung rail line, design specifications need to increase to benefits for each service, which will verify actual contributions and therefore result in an overall economic effect.

A refined Panax ginseng karyotype based on an ultra-high copy 167-bp tandem repeat and ribosomal DNAs

  • Waminal, Nomar Espinosa;Choi, Hong-Il;Kim, Nam-Hoon;Jang, Woojong;Lee, Junki;Park, Jee Young;Kim, Hyun Hee;Yang, Tae-Jin
    • Journal of Ginseng Research
    • /
    • v.41 no.4
    • /
    • pp.469-476
    • /
    • 2017
  • Background: Panax ginseng Meyer (Asian ginseng) has a large nuclear genome size of > 3.5 Gbp in haploid genome equivalent of 24 chromosomes. Tandem repeats (TRs) occupy significant portions of the genome in many plants and are often found in specific genomic loci, making them a valuable molecular cytogenetic tool in discriminating chromosomes. In an effort to understand the P. ginseng genome structure, we characterized an ultrahigh copy 167-bp TR (Pg167TR) and explored its chromosomal distribution as well as its utility for chromosome identification. Methods: Polymerase chain reaction amplicons of Pg167TR were labeled, along with 5S and 45S rDNA amplicons, using a direct nick-translation method. Direct fluorescence in situ hybridization (FISH) was used to analyze the chromosomal distribution of Pg167TR. Results: Recently, we reported a method of karyotyping the 24 chromosome pairs of P. ginseng using rDNA and DAPI (4',6-diamidino-2-phenylindole) bands. Here, a unique distribution of Pg167TR in all 24 P. ginseng chromosomes was observed, allowing easy identification of individual homologous chromosomes. Additionally, direct labeling of 5S and 45S rDNA probes allowed the identification of two additional 5S rDNA loci not previously reported, enabling the refinement of the P. ginseng karyotype. Conclusion: Identification of individual P. ginseng chromosomes was achieved using Pg167TR-FISH. Chromosome identification is important in understanding the P. ginseng genome structure, and our method will be useful for future integration of genetic linkage maps and genome scaffold anchoring. Additionally, it is a good tool for comparative studies with related species in efforts to understand the evolution of P. ginseng.

Development of Indirect Dosimetry by Calculation Method in the Diagnostic X-ray Equipment (진단용엑스선촬영장치의 간접 선량 계산법 개발)

  • Kim, Jung-Su;Kim, Sung-Hwan;Jeon, Min-Cheol;Ju, Won-Ha;Jeong, Min-Gyu;Kim, Mi-Jeong;Lee, Seung-Youl;Lee, Tae-Hee;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.587-594
    • /
    • 2018
  • The purpose of this study was to develop the indirect dosimetry by calculation (IDC) method for diagnostic X-ray equipment. The experiments were performed with inverter type X-ray tubes: Toshiba (E7252X, Japan) and Varian (RAD-14, USA). For the development method, we first applied the standard quality of X-ray beam shown in the TRS457 document, and second, to produce the constants of trendline for the IDC, the total filtration on X-ray beam was subdivided. Third, in order to increase the precision, the energy region was divided into the high energy region and the low energy region and developed by the IDC. In order to verify the IDC, mean dose (mR) values were measured for three Toshiba X-ray tubes and three Varian X-ray tubes at clinical medical institutions and then compared with the IDC on the 2013. As a result, compared with the previous study, the accuracy of the IDC of this study were improved by 2.71% and 9.91% in Toshiba and Varian X-ray tubes, respectively.

A Study on the Application of RTLS Technology for the Automation of Spray-Applied Fire Resistive Covering Work (뿜칠내화피복 작업 자동화시스템을 위한 RTLS 기술 적용에 관한 연구)

  • Kim, Kyoon-Tai
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.5
    • /
    • pp.79-86
    • /
    • 2009
  • In a steel structure, spray-applied fire resistive materials are crucial in preventing structural strength from being weakened in the event of a fire. The quality control of such materials, however, is difficult for manual workers, who can frequently be in short supply. These skilled workers are also very likely to be exposed to environmental hazards. Problems with construction work such as this, which are specifically the difficulty of achieving quality control and the dangerous nature of the work itself, can be solved to some degree by the introduction of automated equipment. It is, however, very difficult to automate the work process, from operation to the selection of a location for the equipment, as the environment of a construction site has not yet been structured to accommodate automation. This is a fundamental study on the possibility of the automation of spray-applied fire resistive coating work. In this study, the linkability of the cutting-edge RTLS to an automation system is reviewed, and a scenario for the automation of spray-applied fire resistive coating work and system composition is presented. The system suggested in this study is still in a conceptual stage, and as such, there are many restrictions still to be resolved. Despite this fact, automation is expected to have good effectiveness in terms of preventing fire from spreading by maintaining a certain level of strength at a high temperature when a fire occurs, as it maintains the thickness of the fire-resistive coating at a specified level, and secures the integrity of the coating with the steel structure, thereby enhancing the fire-resistive performance. It also expected that if future research is conducted in this area in relation to a cutting-edge monitoring TRS, such as the ubiquitous sensor network (USN) and/or building information model (BIM), it will contribute to raising the level of construction automation in Korea, reducing costs through the systematic and efficient management of construction resources, shortening construction periods, and implementing more precise construction

Study on Absorbed Dose Determination of Electron Beam Quality for Cross-calibration with Plane-parallel Ionization Chamber (평행평판형이온함의 교차교정 시 전자선 선질에 따른 흡수선량 결정에 대한 연구)

  • Rah, Jeong-Eun;Shin, Dong-Oh;Park, So-Hyun;Jeong, Ho-Jin;Hwang, Ui-Jung;Ahn, Sung-Hwan;Lim, Young-Kyung;Kim, Dong-Wook;Yoon, Myong-Geun;Shin, Dong-Ho;Lee, Se-Byeong;Suh, Tae-Suk;Park, Sung-Yong
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.97-105
    • /
    • 2009
  • Absorbed dose to water based protocols recommended that plane-parallel chambers be calibrated against calibrated cylindrical chambers in a high energy electron beam with $R_{50}$>7 $g/cm^2$ (E${\gtrsim}$16 MeV). However, such high-energy electron beams are not available at all radiotherapy centers. In this study, we are compared the absorbed dose to water determined according to cross-calibration method in a high energy electron beam of 16 MeV and in electron beam energies of 12 MeV below the cross-calibration quality remark. Absorbed dose were performed for PTW 30013, Wellhofer FC65G Farmer type cylindrical chamber and for PTW 34001, Wellhofer PPC40 Roos type plane-parallel chamber. The cylindrical and the plane-parallel chamber to be calibrated are compared by alternately positioning each at reference depth, $Z_{ret}=0.6R_{50}-0.1$ in water phantom. The $D_W$ of plane-parallel chamber are derived using across-calibration method at high-energy electron beams of 16, 20 MeV. Then a good agreement is obtained the $D_W$ of plane-parallel chamber in 12 MeV. The agreement between 20 MeV and 12 MeV are within 0.2% for IAEA TRS-398.

  • PDF

Study on sea fog detection near Korea peninsula by using GMS-5 Satellite Data (GMS-5 위성자료를 이용한 한반도 주변 해무탐지 연구)

  • 윤홍주
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.4
    • /
    • pp.875-884
    • /
    • 2000
  • Sea fog/stratus is very difficult to detect because of the characteristics of air-sea interaction and locality ,and the scantiness of the observed data from the oceans such as ships or ocean buoys. The aim of our study develops new algorism for sea fog detection by using Geostational Meteorological Satellite-5(GMS-5) and suggests the technics of its continuous detection. In this study, atmospheric synoptic patterns on sea fog day of May, 1999 are classified; cold air advection type(OOUTC, May 10, 1999) and warm air advection type(OOUTC, May 12, 1999), respectively, and we collected two case days in order to analyze variations of water vapor at Osan observation station during May 9-10, 1999.So as to detect daytime sea fog/stratus(OOUTC, May 10, 1999), composite image, visible accumulated histogram method and surface albedo method are used. The characteristic value during day showed A(min) .20% and DA < 10% when visible accumulated histogram method was applied. And the sea fog region which is detected is similar in composite image analysis and surface albedo method. Inland observation which visibility and relative humidity is beneath 1Km and 80%, respectively, at OOUTC, May 10,1999; Poryoung for visble accumulated histogram method and Poryoung, Mokp'o and Kangnung for surface albedo method. In case of nighttime sea fog(18UTC, May 10, 1999), IR accumulated histogram method and Maximum brightness temperature method are used, respectively. Maxium brightness temperature method dectected sea fog better than IR accumulated histogram method with the charateristic value that is T_max < T_max_trs, and then T_max is beneath 700hPa temperature of GDAPS(Global Data Assimilation and Prediction System). Sea fog region which is detected by Maxium brighness temperature method was similar to the result of National Oceanic and Atmosheric Administratio/Advanced Very High Resolution Radiometer (NOAA/AVHRR) DCD(Dual Channel Difference), but usually visibility and relative humidity are not agreed well in inland.

  • PDF