• Title/Summary/Keyword: TOFMS

Search Result 27, Processing Time 0.025 seconds

Ultrasensitive Trace Determination of Pb by Two-Color Resonance Ionization Mass Spectrometry

  • 송규석;차형기;이종민;박종윤;허영덕
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.7
    • /
    • pp.578-582
    • /
    • 1995
  • The resonance ionization mass spectrometry (RIMS) system with angular reflectron type time-of-flight mass spectrometer (AREF-TOFMS) has been developed and characterized. The system is applied for the ultratrace determination of Pb element. The 2-color 3-photon laser ionization scheme is adopted for the study and the mass resolution of the system is determined as T/ΔT=1680. The calibration curve for Pb is obtained in the range of 100 ppb to 0.01 ppb by using standard solutions. The minimal amount of detection for the present RIMS system is determined as less than 100 femtograms (10-13 gram).

Sample Preparation Method for Perfluorochemicals with LC-Tandem Mass Spectrometry in Agricultural Water (LC-Tandem Mass Spectrometry를 활용한 농업용수 중 Perfluorochemicals 분석시료 전처리법)

  • Kim, Jin Hyo;Jin, Cho-Long;Choi, Geun-Hyoung;Park, Byung-Jun
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.1
    • /
    • pp.1-4
    • /
    • 2015
  • The current official perfluorochemicals (PFCs) analysis method is established with hydrophilic-lipophilic balance (HLB) solid phase extraction (SPE) clean-up method with LC-tandem mass spectrometry ($MS^n$). Herein the HLB clean-up method from the official method by Korean government was modified with Envi-Carb$^{TM}$ to improve the clean-up efficiency for agricultural water and the unexpected UV disturbance in the water was effectively removed by the adsorbent treatment without a significant disturbance of quantitation. And quadrupole time of flight mass spectrometry (qTOFMS) was suggested to the available $MS^n$ instruments for the residue analysis of PFCs based on the ng/L of quantitation limits in water as well.

Method Development for the Profiling Analysis of Endogenous Metabolites by Accurate-Mass Quadrupole Time-of-Flight(Q-TOF) LC/MS (LC/TOFMS를 이용한 생체시료의 내인성 대사체 분석법 개발)

  • Lee, In-Sun;Kim, Jin-Ho;Cho, Soo-Yeul;Shim, Sun-Bo;Park, Hye-Jin;Lee, Jin-Hee;Lee, Ji-Hyun;Hwang, In-Sun;Kim, Sung-Il;Lee, Jung-Hee;Cho, Su-Yeon;Choi, Don-Woong;Cho, Yang-Ha
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.4
    • /
    • pp.388-394
    • /
    • 2010
  • Metabolomics aims at the comprehensive, qualitative and quantitative analysis of wide arrays of endogenous metabolites in biological samples. It has shown particular promise in the area of toxicology and drug development, functional genomics, system biology and clinical diagnosis. In this study, analytical technique of MS instrument with high resolution mass measurement, such as time-of-flight (TOF) was validated for the purpose of investigation of amino acids, sugars and fatty acids. Rat urine and serum samples were extracted by selected each solvent (50% acetonitrile, 100% acetonitrile, acetone, methanol, water, ether) extraction method. We determined the optimized liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) system and selected appropriated columns, mobile phases, fragment energy and collision energy, which could search 17 metabolites. The spectral data collected from LC/TOFMS were tested by ANOVA. Obtained with the use of LC/TOFMS technique, our results indicated that (1) MS and MS/MS parameters were optimized and most abundant product ion of each metabolite were selected to be monitorized; (2) with design of experiment analysis, methanol yielded the optimal extraction efficiency. Therefore, the results of this study are expected to be useful in the endogenous metabolite fields according to validated SOP for endogenous amino acids, sugars and fatty acids.

Analytical Characteristics and Applications of Laser Ionization Mass Spectrometry

  • 임훙선;윤하섭;김성규
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.1
    • /
    • pp.32-37
    • /
    • 1997
  • We have built a laser ionization mass spectrometer (LIMS) for chemical composition analysis of solid samples, which employs an Nd:YAG laser and a time-of-flight mass analyzer. In this spectrometer, the maximum mass we identified clearly is higher than 2000 amu. A mass resolution of 230 has been achieved at m/z 208 (Pb element) in the linear TOFMS and can be even improved up to 1550 by employing a reflectron. The detection limit is determined to be on the order of ppm for Fe and In. The depth resolution is found to be about 20Å/spectrum with a laser power of 0.5 J/cm2. We also report a preliminary application of the LIMS to identifying impurities resident in several solid samples.

Metabolite Profiling of Serum from Patients with Tuberculosis

  • Park, Hee-Bin;Yoo, Min-Gyu;Choi, Sangho;Kim, Seong-Han;Chu, Hyuk
    • Microbiology and Biotechnology Letters
    • /
    • v.49 no.2
    • /
    • pp.264-268
    • /
    • 2021
  • Tuberculosis (TB) is a major infectious disease that threatens the life and health of people globally. Here, we performed a metabolomic analysis of serum samples from patients with intractable TB to identify biomarkers that might shorten the TB treatment period. Serum samples collected at the commencement of patients' treatment and healthy controls were analyzed using the capillary electrophoresis and time-of-flight mass spectrometry metabolome analysis method. The analysis identified the metabolites cystine, kynurenine, glyceric acid, and cystathionine, which might be useful markers for monitoring the TB treatment course. Furthermore, our research may provide experimental data to develop potential biomarkers in the TB treatment course.

MALDI-TOF MS System for the Identification of Microorganisms in Milk and Dairy Products (우유 및 유제품 중 미생물 동정을 위한 MALDI-TOFMS활용)

  • Kim, Hyoun Wook;Ham, Jun-Sang;Seol, Kuk-Hwan;Han, Sangha;Park, Beam Young;Oh, Mi-Hwa
    • Journal of Dairy Science and Biotechnology
    • /
    • v.30 no.2
    • /
    • pp.131-137
    • /
    • 2012
  • Rapid and reliable identification of microorganisms is a key for tracing the relationship between the target bacteria and related infectious diseases. Various identification methods such as classical phenotypic analysis, numerical taxonomic analysis, and DNA sequencing have been widely used to classify microorganisms in milk and dairy products. Matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) identifies targeted bacteria in milk and milk products. Several studies have demonstrated that MALDI-TOF MS identification is an efficient and inexpensive method for the rapid and routine identification of isolated bacteria. MALDI-TOF MS could provide accurate identification of bacteria in milk and milk products at the serotype or strain level and enable antibiotic resistance profiling within minutes.

  • PDF

Real Time Monitoring of Ionic Species Generated from Laser-Ablated Pb$(Zr_{0.52}Ti_{0.48})O_3$ Target Using Pulsed-Field Time-Of-Flight Mass spectrometer

  • 최영구;임훙선;정광우
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.8
    • /
    • pp.830-835
    • /
    • 1998
  • The characteristics of the ablation plume generated by 532 nm Nd: YAG laser irradiation of a Pb(Zr0.52Ti0.48)O3 (PZT) target have been investigated using a pulsed-field time-of-flight mass spectrometer (TOFMS). The relative abundance of O+, Ti+, Zr+, Pb+, TiO+, and ZrO+ ions has been measured and discussed. TiO+ and ZrO+ ions were also found to be particularly stable within the laser ablation plasma with respect to PbO+ species. The behavior of the temporal distributions of each ionic species was studied as a function of the delay time between the laser shot and the ion extraction pulse. The most probable velocity of each ablated ion is estimated to be Vmp=1.1-1.6x 105 cm/s at a laser fluence of 1.2 J/cm2, which is typically employed for the thin film deposition of PZT. The TOF distribution of Ti+ and Zr+ ions shows a trimodal distribution with one fast and two slow velocity components. The fast velocity component (6.8x 10' cm/s) appears to consist of directly ablated species via nonthermal process. The second component, originated from the thermal evaporation process, has a characteristic velocity of 1.4-1.6 x 105 cm/s. The slowest component (1.2 x 105 cm/s) is composed of a dissociation product formed from the corresponding oxide ion.

Internal Mixing of Pollutants for Submicron Particles Observed during Springtime in Japan

  • Matsumoto, Jun;Narukawa, Masahiro;Takahashi, Kenshi;Matsumi, Yutaka;Yabushita, Akihiro;Shimizu, Atsushi;Matsui, Ichiro;Sugimoto, Nobuo
    • Asian Journal of Atmospheric Environment
    • /
    • v.3 no.1
    • /
    • pp.27-41
    • /
    • 2009
  • Internally mixed states of submicron particles during transport from the Asian continent to the Pacific Ocean were analyzed using a single-particle time-offlight mass spectrometer. The observation was conducted at Tsukuba in Japan in the spring of 2005 in order to investigate springtime transport of particles from the continent. The sum of ion intensities of sulfate (${HSO_4}^-$) detected in particles originating from the continental air masses counted for 75% of that in all particles during the observation. By analyzing correlations among compounds, origins and internally mixed states of compounds were estimated. It was found that nitrate was mixed with sulfate-rich particles as the air mass approached Japan. It was confirmed that Asian mineral dust particles played significant roles for transport of continental sulfate to Japan. As a result of analysis on internal mixing of chlorine and nitrate, it was implied that the chlorine loss in fine sea salt particles had already proceeded at Tsukuba. It was characteristic that fluoride ions were significantly detected, coal combustion in the Asian Continent can be an important source of fluorides detected in Japan through the westward transportation of fine particles including fluorides.