• Title/Summary/Keyword: TOF

Search Result 1,075, Processing Time 0.038 seconds

Detection Distance and Mounting Location in TOF Sensor Development (TOF 센서 개발에서 감지 거리와 장착 위치)

  • Shin, Seong-Yoon;Cho, Gwang-Hyun;Cho, Seung-Pyo;Shin, Kwang-Seong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.411-413
    • /
    • 2022
  • In this paper, considering the change in the sensing distance according to FoV(Fiele Of View) and the sensing distance according to the reflector, the installation location of the TOF(Time Of Flight) sensor is divided into side part installation and front/rear part installation.

  • PDF

Simple measurement the chelator number of antibody conjugates by MALDI-TOF MS

  • Shin, Eunbi;Lee, Ji Woong;Lee, Kyo Chul;Shim, Jae Hoon;Cha, Sangwon;Kim, Jung Young
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.2
    • /
    • pp.54-58
    • /
    • 2017
  • Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry(MALDI-TOF MS) is one of the powerful methods that enable analysis of small molecules as well as large molecules up to about 500,000 Da without severe fragmentation. MALDI-TOF MS, thus, has been a very useful an analytical tool for the confirmation of synthetic molecules, probing PTMs, and identifying structures of a given protein. In recent nuclear medicine, MALDI-TOF MS liner ion mode helps researcher calculate the average number of chelator(or linkage) per an antibody conjugate, such as DOTA-(or DFO-) trastuzumab for labeling a medical radioisotope. This simple technique can be utilized to improve the labeling method and control the quality at the development of antibody-based radiopharmaceuticals, which is very effected to diagnosis and therapy for in vivo tumor cells, with radioisotopes like $^{89}Zr$, $^{64}Cu$, and 177Lu. To minimize the error, MALDI-TOF MS measurement is repeatedly performed for each sample in this study, and external calibration is carried out after data collection.

Primary repair of symptomatic neonates with tetralogy of Fallot with or without pulmonary atresia

  • Lee, Chang-Ha;Kwak, Jae Gun;Lee, Cheul
    • Clinical and Experimental Pediatrics
    • /
    • v.57 no.1
    • /
    • pp.19-25
    • /
    • 2014
  • Recently, surgical outcomes of repair of tetralogy of Fallot (TOF) have improved. For patients with TOF older than 3 months, primary repair has been advocated regardless of symptoms. However, a surgical approach to symptomatic TOF in neonates or very young infants remains elusive. Traditionally, there have been two surgical options for these patients: primary repair versus an initial aortopulmonary shunt followed by repair. Early primary repair provides several advantages, including avoidance of shunt-related complications, early relief of hypoxia, promotion of normal lung development, avoidance of ventricular hypertrophy and fibrosis, and psychological comfort to the family. Because of advances in cardiopulmonary bypass techniques and accumulated experience in neonatal cardiac surgery, primary repair in neonates with TOF has been performed with excellent early outcomes (early mortality<5%), which may be superior to the outcomes of aortopulmonary shunting. A remaining question regarding surgical options is whether shunts can preserve the pulmonary valve annulus for TOF neonates with pulmonary stenosis. Symptomatic neonates and older infants have different anatomies of right ventricular outflow tract (RVOT) obstructions, which in neonates are nearly always caused by a hypoplastic pulmonary valve annulus instead of infundibular obstruction. Therefore, a shunt is less likely to preserve the pulmonary valve annulus than is primary repair. Primary repair of TOF can be performed safely in most symptomatic neonates. Patients who have had primary repair should be closely followed up to evaluate the RVOT pathology and right ventricular function.

Reliable Identification of Bacillus cereus Group Species Using Low Mass Biomarkers by MALDI-TOF MS

  • Ha, Miyoung;Jo, Hyeon-Ju;Choi, Eun-Kyeong;Kim, Yangsun;Kim, Junsung;Cho, Hyeon-Jong
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.6
    • /
    • pp.887-896
    • /
    • 2019
  • Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS)-based pathogen identification relies on the ribosomal protein spectra provided in the proprietary database. Although these mass spectra can discern various pathogens at species level, the spectra-based method still has limitations in identifying closely-related microbial species. In this study, to overcome the limits of the current MALDI-TOF MS identification method using ribosomal protein spectra, we applied MALDI-TOF MS of low-mass profiling to the identification of two genetically related Bacillus species, the food-borne pathogen Bacillus cereus, and the insect pathogen Bacillus thuringiensis. The mass spectra of small molecules from 17 type strains of two bacilli were compared to the morphological, biochemical, and genetic identification methods of pathogens. The specific mass peaks in the low-mass range (m/z 500-3,000) successfully identified various closely-related strains belonging to these two reference species. The intensity profiles of the MALDI-TOF mass spectra clearly revealed the differences between the two genetically-related species at strain level. We suggest that small molecules with low molecular weight, 714.2 and 906.5 m/z can be potential mass biomarkers used for reliable identification of B. cereus and B. thuringiensis.

The Usefulness of 3T-TOF MR angiography in Patients with Cerebral Infarction (뇌졸중 환자에서 3 Tesla 자기공명혈관조영술의 유용성)

  • Han, Je-Hee;Chung, Tae-Woong;Yoon, Woong;Jang, Nan-Kyu;Shin, Sang-Soo;Lim, Hyo-Soon;Song, Sang-Gook;Jeong, Yong-Yeon;Kang, Heoung-Keun;Seo, Jeong-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.94-100
    • /
    • 2005
  • Purpose : This study was designed to evaluate the usefulness of 3T-TOF MR angiography (3T-TOF MRA) compared with transcranial Doppler sonography (TCD) and conventional angiography (CA) in patients with suspected cerebral infarction. Materials and Methods : Fifty four patients with clinical symptoms of cerebral infarction were involved in this study, and had undergone 3T-TOF MRA and TCD, with CA in 11 patients. On the basis of divisions of the carotid artery, four groups were designated: group I, both vertebral arteries and basilar artery; group II, segment between 2 cm below bifurcation of common carotid artery and genu portion of internal carotid artery; group III, segment between petrous portion of internal carotid artery and bifurcation of anterior and middle cerebral artery; group IV, from bifurcation of anterior and middle cerebral artery to thier distal branches. Two radiologists retrospectively reviewed the vascular imaging and stenosis in 3T-TOF MRA, TCD, and CA. Results : A total of 432 arteries, 108 in each group, were available. The assessment of vascular imaging quality in 3T-TOF MRA is scored 2.98, 2.96, 2.91, 2.88 in 4 groups, respectively. Agreement among 3T-TOF MR angiography, TCD, and CA was high. Conclusion : 3T-TOF MR angiography may be useful method for the assessment of stenotic lesions of cranial vasculature in patients with cerebral infarction.

  • PDF

Effect of Detector-Misalignment on TOF-PET Detector Performance (검출기 정렬 오차가 TOF-PET 검출기의 성능에 미치는 영향성 평가)

  • Yang, Jingyu;Kang, Jihoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.841-846
    • /
    • 2019
  • Effect of misalignment on the performance was evaluated for the development of time-of-flight(TOF)-PET detector. A pair of TOF-PET detector consists of Lutetium-yttrium oxyorthosilicate(LYSO) scintillation crystal with a volume of 3 mm × 3 mm × 20 mm and Geiger-mode avalanche photodiodes(GAPD) photo-sensor with a active area of 3.07 mm × 3.07 mm. Analog output signals from TOF-PET detector were sent to the pre-amplifier and then fed into the gain adjust circuit for achievement of gain homogeneity for each detector. The amplified signals were recorded and digitized by data acquisition system based on oscilloscope. The effect of the detector misalignment between LYSO and GAPD was examined for four different alignment offsets of 0.0 mm, 0.5 mm, 1.0 mm and 1.5 mm for a pair of TOF-PET detector. The photopeak position decreased from ~400 mV to ~250 mV with increasing detector misalignment. the energy resolution and time resolution were degraded from 11.6% to 16.2%, and from 477 ps to 632 ps, respectively. This study demonstrated that PET detector performance was degraded considerably depending on the detector misalignment, which would be a critical issue for the development of TOF-PET detector.

Evaluation of Image Quality for Compressed SENSE(CS) Method in Cerebrovascular MRI: Comparison with SENSE Method (뇌혈관자기공영영상에서 Compressed SENSE(CS) 기법에 대한 영상의 질 평가: SENSE 기법과 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.999-1005
    • /
    • 2021
  • The object of this research is CS, which increases resolution while shortening inspection time, is applied to MRA to compare the quality of images for SENSE and CS techniques and to evaluate SNR and CNR to find out the optimal techniques and to provide them as clinical basic data based on this information. Data were analyzed on 32 patients who performed TOF MRA tests at a university hospital in Chung cheong-do (15 males, 17 females), ICA stenosis:10, M1 Aneurysm:10, and average age 53 ± 4.15). In the inspection, the inspection equipment was Ingenia CX 3.0T, Archieva 3.0T, and 32 channel head coil and 3D gradient echo as a method for equipment data. SNR and CNR of each image were measured by quantitative analysis, and the quality of the image was evaluated by dividing the observer's observation into 5 grades for qualitative evaluation. Imaging evaluation is described as being significant when the p-value is 0.05 or less when the paired T-test and Wilcoxon test are performed. Quantitative analysis of SNR and CNR in TOF MRA images Compared to the SENSE method, the CS method is a method measurement method (p <0.05). As an observer's evaluation, the sharpness of blood vessels: CS (4.45 ± 0.41), overall image quality: CS (4.77 ± 0.18), background suppression of images: CS (4.57 ± 0.18) all resulted in high CS technique (p = 0.000). In conclusion, the Compressed SENSE TOF MRA technique shows superior results when comparing and evaluating the SENSE and Compressed SENSE techniques in increased flow rate magnetic resonance angiography. The results are thought to be the clinical basis material in the 3D TOF MRA examination for brain disease.

Structural Characterization of Branched Polyesters Using TOF-SIMS Combined with Transesterification

  • Lee, Yeonhee;Seunghee Han;Yoon, Jung-Hyeon;Hyuneui Lim;Moojin Suh
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.203-203
    • /
    • 1999
  • Mass spectrometry technique provides the molecular weight distribution, data on the sequence of repeat units, polymer additives, and impurities, and structural information. time-of-Flight secondary Ion Mass Spectrometry (TOF-SIMS) has been used for structural characterization of various polymers1-2. the masses of repeat units and terminal groups and molecular weight distributions of polymers have been determined from their TOF-SIMS spectra. TOF-SMIS provides good sensitivity and structural specificity for high mass ions so that intact oligomers and large polymer fragments are observed. In this study, we investigated the detailed structural information on the oligomers and fragment ions of branched poly(1,3-butylene adipate) and branched poly[di(ethylene glycol) adipate] and the transesterification products of branched polyesters with trifluoroacetic acid or chloro difluoroacetic acid. Branched polyesters were chosen because they are important polymers but difficult to characterize; thus branched polyesters provide challanging test for TOF-SIMS. TOF-SIMS spectra of polyesters are obtained from thin polymer films cast from solution on a silver substrate. A good solvent for a polumer solution disrupts intermolecular forces between polymer chains but leaves the polumer intact. Transesterification reactions are potentially useful for characterization of high molecular weight and intractable polyesters. Transesterification products of polyesters and trifluoroacetic acid or an integral number of polyester repeat units and an additional diol. The progress of such reactions was monitored using peak intensities of reactants and products in TOF-SIMS spectra. The increasing abundance of tagged ions indicates that the reaction has progressed with time.

  • PDF

Verification with of High Efficiency Chemical Binding System of a Physiologically Active Radioisotope Using ESI-TOF/Ms System (고효율의 ESI-TOF/Ms 시스템을 이용한 생리활성 항체와 방사성동위원소 표지용 착화제의 결합 검증)

  • Joh, Eun-Ha;Hong, Young Don;Choi, Sun Ju
    • YAKHAK HOEJI
    • /
    • v.57 no.6
    • /
    • pp.400-405
    • /
    • 2013
  • In this study, we measured the complex efficiency of a physiologically active antibody, a chelator and radiosiotopes using the ESI-TOF/Ms system for develop good radiopharmaceuticals. For a precise measurement, TLC is a low accuracy method. Loading of same amount of sample is difficult for each test, and work to quantify accurately the results obtained through TLC cannot be afforded compared to the use of other analytical instruments. The method of analysis using a mass spectrometer is capable of a mass analysis of proteins for quantitative analysis. The conjugates of the chelator (CHX-A- DTPA) and the antibody (IgG) were separated through MWCO, and were analyzed using ESI-TOF and MALDI-TOF mass spectrometry. The analysis using MALDI-TOF is roughly divided into measurements on mass spectrometry. When conjugating a small molecular weight of CHX-A-DTPA and a large molecular weight of IgG, distinguishing the peak of the conjugate and the peak of IgG was difficult. However, an ESI-TOF mass spectrometer system is capable of an analysis of mass by decentralizing the IgG. It is utilized as a technique for measuring the metabolic processes during conjugation and the stability evaluation of radiopharmaceuticals. When establishing this technique, the accuracy of the overall radiophar-maceutical analysis is expected to be able to be improved.

Simultaneous Analysis of Conazole Fungicides in Garlic by Q-TOF Mass Spectrometer Coupled with a Modified QuEChERS Method

  • Bong, Min-Sun;Yang, Si-Young;Lee, Seung-Ho;Seo, Jung-Mi;Kim, In-Seon
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.3
    • /
    • pp.323-329
    • /
    • 2011
  • BACKGROUND: The conazoles, difenoconazole, diniconazole, hexaconazole, penconazole and tetraconazole are a large class of synthetic fungicides used extensively for foliage and seed treatments in agricultural crops. The extensive use of conazoles has brought concerns on the potentiality of environmental contamination and toxicity. Thus studies on the development of methods for monitoring the conazoles are required. METHODS AND RESULTS: A modified quick, easy, effective, rugged and safe (QuEChERS) method was involved in sample preparation. Quadrapole time of flight mass spectrometer (Q-TOF MS) in electron spray ionization (ESI) mode was employed to determine conazoles in garlic samples. The limit of detection (LOD) and limit of quantification (LOQ) of conazoles by Q-TOF-MS ranged from 0.001 to 0.002 mg/L and 0.002 to 0.005 mg/L, respectively. Q-TOF-MS analysis exhibited less than 2.6 ppm error of accurate mass measurements for the detection of conazoles spiked at 0.05 mg/L in garlic matrix. Recovery values of conazoles fortified in garlic samples at 0.02, 0.05 and 0.1 mg/L were between 79.2 and 106.2% with a maximum 11.8% of standard deviation. No detectable conazoles were found in the domestic market samples by using the Q-TOF-MS method. CONCLUSION(s): High degree of confirmation for conazoles by accurate mass measurements demonstrated that Q-TOF-MS analysis combined with a QuEChERS method may be applicable to simultaneous determination of conazoles in garlic samples.