• Title/Summary/Keyword: TOF(Time Of Flight Method)

Search Result 137, Processing Time 0.052 seconds

Study on the Analytical Method and Monitoring of the Oxidized Polyethylene Wax in Foods (식품 중 oxidized polyethylene wax 분석법 연구 및 함유량 실태 조사)

  • Choi, Seung-Hyun;Kim, Jae-Min;Choi, Sun-il;Jung, Tae-Dong;Cho, Bong-Yeon;Lee, Jin-Ha;Lee, Gunyoung;Lim, Ho Soo;Yun, Sang Soon;Lee, Ok-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.4
    • /
    • pp.284-289
    • /
    • 2017
  • Oxidized polyethylene wax (OPEW) is, one of the food additives, used as a coating agent in citrus fruits and nuts. OPEW is authorized to quantum satis in EU, USA, and is acceptable less than 250 mg/kg in Australia and New Zealand. But OPEW is unauthorized as a food additive in Korea. This study was to establish the analytical method of OPEW and demonstrate the effective application of various food samples. We first conducted to compare the various analytical method including acid value (AV), high temperature gel permeation chromatography (HT-GPC), matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF/MS), gas chromatography flame ionization detector (GC-FID) and fourier transform infrared spectroscopy (FT-IR). This result indicated that FT-IR spectrum of OPEW treated food sample displayed absorption bands for carbonyl group (C=O, $1714cm^{-1}$), ester group (C-O, $1463cm^{-1}$), aliphatic group (C-H, $2916cm^{-1}$). Furthermore, IR spectrum of OPEW treated food sample showed similar tendency with IR spectrum of OPEW standard. Therefore, it is confirmed that analytical method using FT-IR can be detected on analysis of OPEW in food. As a result of monitoring of 111 samples using established analytical method, OPEW was not detected in the food samples.

Evaluation of Image Quality Based on Time of Flight in PET/CT (PET/CT에서 재구성 프로그램의 성능 평가)

  • Lim, Jung Jin;Yoon, Seok Hwan;Kim, Jong Pil;Nam Koong, Sik;Shin, Seong Hwa;Yoon, Sang Hyeok;Kim, Yeong Seok;Lee, Hyeong Jin;Lee, Hong Jae;Kim, Jin Eui;Woo, Jae Ryong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.110-114
    • /
    • 2012
  • Purpose : PET/CT is widely used for early checking up of cancer and following up of pre and post operation. Image reconstruction method is advanced with mechanical function. We want to evaluate image quality of each reconstruction program based on time of flight (TOF). Materials and Methods : After acquiring phantom images during 2 minutes with Gemini TF (Philips, USA), Biograph mCT (Siemens, USA) and Discovery 690 (GE, USA), we reconstructed image applied to Astonish TF (Philips, USA), ultraHD PET (Siemens, USA), Sharp IR (GE, USA) and not applied. inside of Flangeless Esser PET phantom (Data Spectrum corp., USA) was filled with $^{18}F$-FDG 1.11 kBq/ml (30 Ci/ml) and 4 hot inserts (8. 12. 16. 25 mm) were filled with 8.88 kBq/ml (240 ${\mu}Ci/ml$) the ratio of background activity and hot inserts activity was 1 : 8. Inside of triple line phantom (Data Spectrum corp., USA) was filled with $^{18}F$-FDG 37 MBq/ml (1 mCi). Three of lines were filled with 0.37 MBq (100 ${\mu}Ci$). Contrast ratio and background variability were acquired from reconstruction image used Flangeless Esser PET phantom and resolution was acquired from reconstruction image used triple line phantom. Results : The contrast ratio of image which was not applied to Astonish TF was 8.69, 12.28, 19.31, 25.80% in phantom lid of which size was 8, 12, 16, 25 mm and it which was applied to Astonish TF was 6.24, 13.24, 19.55, 27.60%. It which was not applied to ultraHD PET was 4.94, 12.68, 22.09, 30.14%, it which was applied to ultraHD PET was 4.76, 13.23, 23.72, 31.65%. It which was not applied to SharpIR was 13.18, 17.44, 28.76, 34.67%, it which was applied to SharpIR was 13.15, 18.32, 30.33, 35.73%. The background variability of image which was not applied to Astonish TF was 5.51, 5.42, 7.13, 6.28%. it which was applied to Astonish TF was 7.81, 7.94, 6.40 6.28%. It which was not applied to ultraHD PET was 6.46, 6.63, 5.33, 5.21%, it which was applied to ultraHD PET was 6.08, 6.08, 4.45, 4.58%. It which was not applied to SharpIR was 5.93, 4.82, 4.45, 5.09%, it which was applied to SharpIR was 4.80, 3.92, 3.63, 4.50%. The resolution of phantom line of which location was upper, center, right, which was not applied to Astonish TF was 10.77, 11.54, 9.34 mm it which was applied to Astonish TF was 9.54, 8.90, 8.88 mm. It which was not applied to ultraHD PET was 7.84, 6.95, 8.32 mm, it which was applied to ultraHD PET was 7.51, 6.66, 8.27 mm. It which was not applied to SharpIR was 9.35, 8.69, 8.99, it which was applied to SharpIR was 9.88, 9.18, 9.00 mm. Conclusion : Image quality was advanced generally while reconstruction program which is based on time of flight was used. Futhermore difference of result compared each manufacture reconstruction program showed up, however this is caused by specification of instrument of each manufacture and difference of reconstruction algorithm. Therefore we need further examination to find out appropriate reconstruction condition while using reconstruction program used for advance of image quality.

  • PDF

MR Angiography with Simultaneous Data Acquisition of Arteries and Veins(SAAV) Method and Artery-Vein Color Mapping in 0.3T MRI System (0.3T MRI 시스템에서의 동.정맥 동시 획득을 위한 자기공명 혈류 영상 기법(SAAV)과 동.정맥 color mapping)

  • 조종운;조지연;서성만;은충기;문치웅
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.275-280
    • /
    • 2003
  • The method of simultaneous data acquisition of arteries and veins(SAAV) was suggested to obtain MR angiography of arteries and veins at 0.3T low filed MRI system (Magfinder, AlLab. Korea). Two separated artery- and vein-images were put together using AVCM(Artery-Vein Color Mapping) algorithm and presented in the same image. In this study, artery- and vein-separated angiograms of volunteer's neck were obtained. Two dimensioal blood-enhanced images wre sequentially obtained using SAAV pulse sequence based on time-of-flight(TOF) method with flow compensation. Imaging parameters were TR/TE=70/12msec. FOV=230mm, slice thickness = 3mm, flip angle=90$^{\circ}$, matrix size=256${\times}$256${\times}$64mm. TSat TH/SPA=15/20mm, Ts_v=10msec and Ts_a=40ms. 3D MRA images were reconstructed using the maximum intensity projection(MIP) and the artery-vein color mapping(AVCM) algorithm. This study showed good possibility of clinical applications of MRA in 0.3T which provides valuable diagnostic information of clinical vascular diseases.

A Study of the Characteristics of Highly Spatially Resolved CW-laser-based Aerosol Lidar (고공간분해능 연속 광원을 이용한 미세먼지 라이다의 신호 특성에 관한 연구)

  • Sim, Juhyeon;Kim, Taekeong;Ju, Sohee;Noh, Youngmin;Kim, Dukhyeon
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.1
    • /
    • pp.1-10
    • /
    • 2022
  • In this study we introduce a new method for high-spatial-resolution continuous wave (CW) aerosol lidar that has a high spatial resolution in the near field and a low spatial resolution at long distances. A normal lidar system uses a nanosecond-pulse laser and measures the round-trip TOF between the aerosol and laser to obtain range resolution. In this study, however, we propose a new type of spatially resolving aerosol lidar that uses laser-scattering images. Using a laser-light-scattering image, we have calculated the distance of each scattering aerosol image for a given pixel, and recovered the short-range aerosol extinction. For this purpose, we have calculated the distance image and the contribution range of the aerosol to the given one-pixel image, and finally we have calculated the extinction coefficients of the aerosol with range-resolved information. In the case of traditional aerosol lidar, we can only obtain the aerosol extinction coefficients above 400 m. Using our suggested method, it was possible to extend the range of the extinction coefficient lower then several tens of meters. Finally, we can remove the unknown short-range region of pulsed aerosol lidar using our method.

Clinical Laboratory Aspect of Carbapenem-Resistant Enterobacteriaceae (카바페넴내성장내세균속균종의 임상검사 측면)

  • Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.1
    • /
    • pp.18-27
    • /
    • 2020
  • The correct distinction of carbapenem-resistant Enterobacteriaceae (CRE) and ccarbapenemase producing Enterobacteriaceae (CPE) and the rapid detection of CPE are important for instituting the correct treatment and management of clinical infections. Screening protocols are mainly based on cultures of rectal swab specimens on selective media followed by phenotypic tests to confirm a carbapenem-hydrolyzing activity, the rapid carbapenem inactivation method, lateral flow immunoassay, the matrix-assisted laser desorption ionization-time-of-flight test and molecular methods. The CPE is accurate for detection, and is essential for the clinical treatment and prevention of infections. A variety of phenotypic methods and gene-based methods are available for the rapid detection of carbapenemases, and these are expected to be routinely used in clinical microbiology laboratories. Therefore, to control the spread of carbapenemase, many laboratories around the world will need to use reliable, fast, high efficiency, simple and low cost methods. Optimal effects in patient applications would require rapid testing of CRE to provide reproducible support for antimicrobial management interventions or the treatment by various types of clinicians. For the optimal test method, it is necessary to combine complementary test methods to discriminate between various resistant bacterial species and to discover the genetic diversity of various types of carbapenemase for arriving at the best infection control strategy.

Classification and identification of organic aerosols in the atmosphere over Seoul using two dimensional gas chromatography-time of flight mass spectrometry (GC×GC/TOF-MS) data (GC×GC/TOF-MS를 이용한 서울 대기 중 유기 에어로졸의 분류 및 동정)

  • Jeon, So Hyeon;Lim, Hyung Bae;Choi, Na Rae;Lee, Ji Yi;Ahn, Yun Kyong;Kim, Yong Pyo
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.153-169
    • /
    • 2018
  • To identify a variety of organic compounds in the ambient aerosols, the two-dimensional gas chromatography-time of flight mass spectrometry (GCxGC) system (2DGC) has been applied. While 2DGC provides more peaks, the amount of the generated data becomes huge. A two-step approach has been proposed to efficiently interpret the organic aerosol analysis data. The two-dimensional 2DGC data were divided into 6 chemical groups depending on their volatility and polarity. Using these classification standards, all the peaks were subject to both qualitative and quantitative analyses and then classified into 8 classes. The aerosol samples collected in Seoul in summer 2013 and winter 2014 were used as the test case. It was found that some chemical classes such as furanone showed seasonal variation in the high polarity-volatile organic compounds (HP-VOC) group. Also, for some chemical classes, qualitative and quantitative analyses showed different trends. Limitations of the proposed method are discussed.

Predicting Parturition Time through Ultrasonic Measurement of Posture Changing Rate in Crated Landrace Sows

  • Wang, J.S.;Wu, M.C.;Chang, H.L.;Young, M.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.5
    • /
    • pp.682-692
    • /
    • 2007
  • This study presents an automatic system to predict parturition time in the crated sows. The system relies on ultrasonic transducers mounted from above along the length of the crate. Using a 40 kHz time of flight (TOF) single envelope wave, the momentary distances between the sensors are measured. Therefore, the local momentary height of the sow and the momentary posture, i.e. standing posture (SDP), kneeling posture (KP), sitting posture (STP) and lateral lying posture (LLP) are determined. Crated sows change their postures from standing to lying and vice versa which follows a characteristic pattern. As parturition approaches, sows exhibit uneasiness, restlessness and the stand up sequence (SUS, the posture transition from LLP to SDP) rate increases because of labor pains. In time series, the SUS rate demonstrates a peak and it happens approximately 0-12 h before parturition. In this paper, the basic parturition threshold value method (BPTVM) and the same hour method (SHM) are proposed for predicting parturition, both of which are based on the SUS rate. The BPTVM mainly detects the peak of the SUS rate. As the SUS rate exceeds the threshold value, the parturition becomes predictable. Moreover, the SHM calculates the difference in the SUS rates between a particular time of day and the corresponding time of the preceding day. Compared to the BPTVM, the SHM can eliminate the circadian rhythm of the SUS rate influenced by feeding behavior. Using the SHM the parturition can be approximately predicted within hours. In an attempt to define the threshold parameters of predicting parturition, a data set with 32 sows of the SUS rate are used to estimate assumable predicting probability. The results show the assumable probability of the parturition prediction within 9 h is 96.9% for the SHM and 84.4% for the BPTVM. Moreover, the SHM can even reach a 75% probability of prediction within three hours of parturition. We conclude that the SHM is more accurate and is more useful for parturition time prediction. When parturition is detected, the proposed algorithm generates a warning signal which can inform human personnel to protect the mother and newborn piglets.

Quantification of Pre-parturition Restlessness in Crated Sows Using Ultrasonic Measurement

  • Wang, J.S.;Huang, Y.S.;Wu, M.C.;Lai, Y.Y.;Chang, H.L.;Young, M.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.6
    • /
    • pp.780-786
    • /
    • 2005
  • This study presents a non-video, non-invasive, automatic, on-site monitoring system the system employs ultrasonic transducers to detect behavior in sows before, during and after parturition. An ultrasonic transmitting/receiving (T/R) circuit of 40 kHz was mounted above a conventional parturition bed. The T/R units use ultrasonic time-of-flight (TOF) ranging technology to measure the height of the confined sows at eight predetermined locations. From this data, three momentary postures of the sow are determined, characterized as standing-posture (SP), lateral-lying-posture (LLP) and sitting posture (STP). By examining the frequencies of position switch Stand-Up-Sequence (SUS) between standing-posture (SP), lateral-lying-posture (LLP) and sitting-posture (STP) rate can be determined for the duration of the sow' confinement. Three experimental pureblooded Landrace sows undergoing normal gestation were monitored for the duration of confinement. In agreement with common observation, the sows exhibited increased restlessness as parturition approached. Analysis of the data collected in our study showed a distinct peak in Stand-Up-Sequence (SUS, i.e. the transition from lying laterally to standing up ) and sitting-posture (STP) rate approximately 12 h prior to parturition, the observed peak being 5 to 10 times higher than observed on any other measurement day. It is concluded that the presented methodology is a robust, low-cost, lowlabor method for the continuous remote monitoring of sows and similar large animals for parturition and other behavior. It is suggested that the system could be applied to automatic prediction of sow parturition, with automatic notification of remote management personnel so human attendance at birth could reduce rates of sow and piglet mortality. The results of this study provide a good basis for enhancing automation and reducing costs in large-scale sow husbandry and have applications in the testing of various large mammals for the effects of medications, diets, genetic modifications and environmental factors.

Plasma Lipidomics as a Tool for Diagnosis of Extrahepatic Cholangiocarcinoma in Biliary Strictures: a Pilot Study

  • Prachayakul, Varayu;Thearavathanasingha, Phataraphong;Thuwajit, Chanitra;Roytrakul, Sittiruk;Jaresitthikunchai, Janthima;Thuwajit, Peti
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.8
    • /
    • pp.4155-4161
    • /
    • 2016
  • Biliary obstruction is a common clinical manifestation of various conditions, including extrahepatic cholangiocarcinoma. However, a screening test for diagnosis of extrahepatic cholangiocarcinoma in patients with biliary obstruction is not yet available. According to the rationale that the biliary system plays a major role in lipid metabolism, biliary obstruction may interfere with lipid profiles in the body. Therefore, plasma lipidomics may help indicate the presence or status of disease in biliary obstruction suspected extrahepatic cholangiocarcinoma. This study aimed to use plasma lipidomics for diagnosis of extrahepatic cholangiocarcinoma in patients with biliary obstruction. Plasma from healthy volunteers, patients with benign biliary obstruction extrahepatic cholangiocarcinoma, and other related cancers were used in this study. Plasma lipids were extracted and lipidomic analysis was performed using matrix-assisted laser desorption ionization time-of-flight mass spectrometry. Lipid profiles from extrahepatic cholangiocarcinoma patients showed significant differences from both normal and benign biliary obstruction conditions, with no distinction between the latter two. Relative intensity of the selected lipid mass was able to successfully differentiate all extrahepatic cholangiocarcinoma samples from patient samples taken from healthy volunteers, patients with benign biliary obstruction, and patients with other related cancers. In conclusion, lipidomics is a non-invasive method with high sensitivity and specificity for identification of extrahepatic cholangiocarcinoma in patients with biliary obstruction.

Measurement of Energy Dependent Differential Neutron Capture Cross-section of Natural Sm by Using a Continuous Neutron Flux below (연속에너지 중성자에 대한 천연 Sm의 중성자 포획단면적 측정)

  • Yoon, Jungran
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.337-341
    • /
    • 2016
  • We measured the neutron capture cross-section of natural Sm(n,${\gamma}$) reaction in the energy regions from 0.003 to 10 eV. The 46-MeV electron linear accelerator of Research Reactor Institute, Kyoto University was used for generating a continuous neutron source. The neutron time-of-flight method was adopted for energy measurement. An assembly of BGO($Bi_4Ge_3O_{12}$) scintillators composed of 12 pieces of BGO crystals measured prompt gamma rays from Sm(n,${\gamma}$) reaction. The BGO assembly was located at a distance of $12.7{\pm}0.02m$ from the neutron source. In order to determine the neutron flux impinging on the Sm, the $^{10}B(n,{\alpha}{\gamma})^7Li$ standard cross-section were used. Natural Sm(n,${\gamma}$) reaction measurement result of the neutron capture cross-section was compared with the results of evaluation of the BROND-2.2 and the previous experimental data of J. C. Chou and V. N. Kononov.