• Title/Summary/Keyword: TOC 제거

Search Result 162, Processing Time 0.021 seconds

Removal Properties of Methylene Blue in Catalytic Ozonation (촉매오존화에 의한 메틸렌 블루 제거특성)

  • Chung, Jae-Woo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.3
    • /
    • pp.5-12
    • /
    • 2017
  • Effects of operating parameters such as activated carbon dose, gaseous $O_3$ concentration and pH on the properties of methylene blue(MB) degradation in a catalytic ozonation were investigated through a series of batch experiments. Activated carbon catalyzed the self-decomposition of ozone, generating $OH{\cdot}$, thus promoting MB degradation. Thus the increase of activated carbon dose enhanced the MB and TOC removal. The higher gaseous ozone concentration injected, the promoted MB and TOC removal obtained through the enhanced mass transfer. The MB removal was not significantly affected by the variation of aqueous pH. Catalytic ozonation can be considered as an efficient alternative in treating refractory pollutants in textile wastewater with faster and higher dye and TOC removal compared with ozonation and adsorption.

혐기성 고정 생물막 공정에서 유입 농도의 변화에 따른 기질 전달 현상

  • Lee, Deok-Hwan;Kim, Do-Han;Park, Yeong-Sik;Yun, Tae-Yeong;Song, Seung-Gu
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.351-354
    • /
    • 2002
  • This research discussed about the substrate transport phenomena in anaerobic biofilm. Three anaerobic fixed biofilm reactors were filled with the sludge of anaerobic digestor from Suyoung wastewater treatment plant. After 15 days of biofilm formation periods, suspended solids within the reactors were removed, and each fixed biofilm reactor was supplied with synthetic wastewater of different concentration of 8.00 mgTOC/L, 9.76 mgTOC/L and 18.97 mgTOC/L, respectively. The experimental results in conjunction with substrate transfer phenomena indicated that data - thickness, substrate removal rate. At the low influent substrate concentration(reactor 1 : 8.00 mgTOC/L, reactor 2 : 9.76 mgTOC/L), the rate of substrate utilization($k_v$), effective diffusivity($D_{eff}$) of substrate in biofilm were similar. While $k_v$ and $D_{eff}$ of the high influent substrate concentration(reactor 3 : 18.97 mgTOC/L) were higher than data in the reactors of the low influent substrate concentration.

  • PDF

O$_3$/H$_2$O$_2$와 O$_3$/Catalyst 고급산화공정에서 1,4-dioxane의 제거 특성 연구

  • Park, Jin-Do;Seo, Jung-Ho;Lee, Hak-Sung
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2005.11a
    • /
    • pp.192-194
    • /
    • 2005
  • O$_3$/H$_2$O$_2$ 고급산화공정에서 1,4-D의 제거는 반응시간에 따라 완만하게 감소하였으나, O$_3$/catalyst 고급산화공정에서는 전체 제거량의 약 50${\sim}$75%가 반응 초기 5분 내에 제거되어 O$_3$/H$_2$O$_2$ 공정에 비해 초기 반응속도가 현저히 빠른 것을 알 수 있었다. O$_3$/H$_2$O$_2$ 고급산화공정은 ${\Delta}$TOC/${\Delta}$ThOC의 비는 0.09${\sim}$0.40으로 나타났으며, O$_3$/catalyst 고급산화공정에서는 ${\Delta}$TOC/${\Delta}$ThOC의 비가 0.68${\sim}$0.98로 나타나 O$_3$/catalyst 고급산화공정이 O$_3$/H$_2$O$_2$ 고급산화공정에 비해 유기물의 산화력이 우수한 것으로 확인되었다.

  • PDF

Evaluation of Oxic Denitrification in A2O Fixed Biofilm System through Mass Balance (물질수지를 이용한 A2O 고정생물막법에서의 호기탈질평가)

  • Yoon, Cho-Hee;Park, Seung-Hwan;Lee, Sang-Hoon;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.231-239
    • /
    • 2000
  • This study was investigated to estimate optimal conditions and biological oxic denitrification to treat wastewater with low C/N ratio and high strength total inorganic nitrogen (TIN) concentration by using $A_2O$ fixed biofilm system. The lab-scale experimental system packed with media, which were composed of polyvinylidene chloride fiber (oxic basin) and ceramic ball (anaerobic and anoxic basin), was used. This system was operated with various influent alkalinities at the C/N(TOC/TIN) ratio of 0.5. The study results showed that TOC were removed over 96.0% at all operation conditions. The removal efficiencies over 93.5% for $NH_4{^+}-N$ and 81.8% for TIN were obtained at the alkalinity of about 1210mg/L(Run 5). Among the removal of TIN, 64.9% was occurred by biological denitrification at an oxic basin. It was confirmed through mass balance of alkalinity and nitrogen that the amount of alkalinity produced during biological denitrification at oxic basin was 2.49~3.46 mg Alkalinity/mg $NO_2{^-}-N$, ${\Delta}TOC/{\Delta}DEN$ of 0.34 (Run 5) was obtained at an oxic basin, which was less than the theoretical value of 1.22.

  • PDF

Recovery of Caustic Soda in Textile Mercerization by Combined Membrane Filtration (복합 막분리 공정에 의한 섬유가공 공정에서의 가성소다 회수)

  • Yang, Jeong-Mok;Park, Chul-Hwan;Cho, Jin-Ku;Kim, Sang-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.12
    • /
    • pp.1273-1280
    • /
    • 2008
  • This study sought to establish the optimum operating condition for the recovery of caustic (NaOH) solution from mercerization in textile process. As main factors, the silt density index (SDI) evaluation of ceramic membrane for the application of nanofiltration/reverse osmosis (NF/RO) membrane, the recovery yield measurement of caustic solution for the application of polymeric membrane, the optimum condition of chemical cleaning for the membrane regeneration, the optimum removal condition of total organic carbon (TOC), turbidity, color, and the permeate flux of ceramic membrane/polymeric membrane combined process were investigated. As results, ceramic ultrafiltration (UF) in the first step and nanofiltration (NF) in the second step were found to be suitable for the removal of total suspended solid (TSS), residual organics, turbidity including color, and the recovery of caustic solution from caustic wastewater stream in mercerization process. When only the ceramic UF membrane was used, the rejection efficiency of both of TSS and turbidity was more than 99.0%, and the color and TOC were rejected about 74.7% and 49.2%, respectively. Meanwhile, the combined membrane precess of UF and NF membranes showed even more efficient removal abilities and thus more than 99.9% of TSS and turbidity, 87.7% of color, and 78.2% of TOC were removed. In particular, 91.3% of NaOH was successfully recovered with 83.7% of total volume in the combined membrane process. With this regard, a clean caustic solution was obtained in a high purity, which can be reused for mercerization process, expecting to offer economical benefits.

Characterization of Humic Acid in the Chemical Oxidation Technology(II) - Characteristics by Ozonation - (화학적 산화법에 의한 부식산의 분해처리 기술에 관한 연구(II) - 오존처리에 따른 분해특성 분석 -)

  • Rhee, Dong Seok;Jung, Young-Rim
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.241-249
    • /
    • 2000
  • In this paper, ozonation of humic acid in water was characterized using $UV_{254}$ absorbance, TOC, Ultra Filtration and $^{13}C-NMR$. Also, carbonyl compounds in ozonated water were analyzed by GC/MS using PFBOA method. Ozonation by-products of water containing humic acid were determined as formaldehyde, acetaldehyde, acetone, glyoxal and methylglyoxal. Results of $UV_{254}$ absorbance and TOC with ozonation time at humic acid 20, 100ppm represent that decrease rate of 80% within ozonation time is 20 min and TOC removal rate of 40-50% within ozonation time is 30 min. Results for $^{13}C-NMR$ and Ultra Filtration, humic acid of high molecular weight by ozonation are oxidated and decomposed so that it was conversed low molecular weight such as aldehydes, carboxylic acid.

  • PDF

A Study of Ozonation of Dimethyl Phthalate (Dimethyl Phthalate의 오존산화 반응에 관한 연구)

  • Lee, Cheal-Gyu;Song, Jun-O
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.10
    • /
    • pp.703-709
    • /
    • 2013
  • Ozonation was performed under various experimental conditions that $Al_2O_3$ catalysts dosage and temperature for removal of DMP in laboratory scale batch reactor. Flow rate of ozone $1.0Lmin^{-1}$ and ozone concentration of $300{\pm}10mgL^{-1}$ were maintained constantly, and the pH, $COD_{Cr}$ and TOC was measured in 10 min intervals during the 60 min at oxidation processes. As a result, the presence of the $Al_2O_3$ than only ozonation increased the removal efficiency of both $COD_{Cr}$ and TOC in solution. The pseudo first-order rate constants for the elimination of $COD_{Cr}$ and TOC were $3.65{\times}10^{-4}sec^{-1}$, $2.52{\times}10^{-4}sec^{-1}$, and activation energy was $0.75kcal{\cdot}mol^{-1}$ and $0.70kcal{\cdot}mol^{-1}$ at $20^{\circ}C$, respectively.

The Study of Removal of Organic Matter by the Rockworm, Marphysa sanguinea (바위털갯지렁이, Marphysa sanguinea에 의한 유기물 제거에 관한 연구)

  • Baek, Ami;Lee, Kyoung Seon
    • Journal of Marine Life Science
    • /
    • v.3 no.1
    • /
    • pp.38-43
    • /
    • 2018
  • The polychaetes are the dominant species in the benthic communities, and play an important role in improving the sediment quality through the action of ingesting organic materials. We evaluated the improvement ability of rockworm Marphysa sanguinea for the removal of organic matter. We used the three types of sediment (S1: coarse sand, S2: fine sand, S3: muddy sand), and analyzed TOC of seawater and sediment. Rockworm was effective in eliminating organic matter in the three types of sediment and the larger the particle, the higher the removal rate. Removal ability of rockworm for organic matter in sediment were calculated with 3.9856 ppm g-1d-1 in coarse sand, 2.8021 ppm g-1d-1 in fine sand, and 28.1142 ppm g-1d-1 in muddy sand. The results show that rockworm contributes to the removal of organic matter in the various sediment types.

Full-scale Case Study on the Relationship between Surface Characteristics of GAC and TOC Removal (입상활성탄의 표면특성과 TOC제거와의 상관성 연구)

  • Baek, Youngae;Joe, Woohyun;Hong, Byungeui;Kim, Kwangho;Choi, Young-june
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.323-328
    • /
    • 2008
  • During the full-scale water treatment operation at "G" Water Treatment Plant in Seoul, we investigated changes in pore volume distribution and specific surface area of GAC with time. The pore volume of the used GAC decreased to the level below 0.6 cc/g while that of the brand new GAC was ranged 0.7~0.9 cc/g. The specific surface area of GAC pores changed within the range between $1100{\sim}1200m^2/g$ and $700{\sim}800m^2/g$. Bacteria attached to the surface of GAC shows a gradual increase ($0.4{\time}10^6{\sim}8.5{\time}10^6CFU/g$) under scanninig electron microscope (SEM). TOC removal was enhanced due to growth of the attached bacteria on GAC. It was found that TOC removal was closely related with physical parameters (pore volume, specific surface area) linearly under the investigated conditions. The used GAC need to be exchanged into new one or re-generated to remove organic matters (TOC) effectively from the finished drinking water.