• Title/Summary/Keyword: TO-CAN laser diode

Search Result 208, Processing Time 0.178 seconds

Design and Fabrication of Laser Diode Integrated with Peltier Cooler (열전 냉각기가 집적된 레이저 다이오드)

  • 이상일;박정호
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.1
    • /
    • pp.159-165
    • /
    • 1995
  • A double-heterostructure mesa-stripe-geometry laser diode integrated with thermoelectric Peltier cooler has been designed and fabricated. Epi-layers have been grown by metal organic chemical vapor deposition(MOCVD) method. Peltier cooling effect has been measured for devices with a mesa width of 14$\mu$m and a cavity length of 380$\mu$m. The effects of thermoelectric cooling could be shown by measuring the optical output of the laser with the increase of the current in the thermoelectric cooler. While the input courrent of the laser was maintained at 250mA, the optical output was decreased from 4.8mW to 3.8mW due to heating, but with the thermoelectric cooler on the optical output power was recovered by more than 40%. The results show that the complicated cooling device is not needed since the cooling can be achevied by the developement of the fabrication processing.

  • PDF

The Development of 63nm Diode Laser System for Photodynamic Therapy of Cancer (광역학적 암치료를 위한 635nm 다이오드 레이저 시스템 개발)

  • 임현수
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.319-328
    • /
    • 2003
  • The purpose of this paper is to develop a medical laser system using the semiconductor diode laser in order to photodynamic cancel therapy as a light source. The ideal light source for photodynamic therapy would be a homogeneous nondiverging light with variable spot size and specific wavelength with stability. After due consideration in this point, in this paper, we used a diode laser resonator of 635nm wavelength. The development laser system have a statistical laser out beam with accuracy control using the constant current control of method and clinic-friendly with compact. In order to protect the diode resonator from the over-current, the rush-current and electrical fault, we specially designed. The most importance therapeutic factor are the radiation mode for cancer therapy. So we developed the radiation mode of CW(Continuous Wave), long pulse, short pulse, and burst pulse and can adjust the exposure time from several milli-second to several minute. The experimental result shows that laser beam power was increased linear from 10mW to 300mW according to the increasing input current and the increasing exposure time. The developed new compact diode laser system have a stability of output power and specific wavelength with easy control and transportable for many applications of PDT.

Heat Treatment Characteristics of Press Blanking Die by Using High Power Diode Laser (고출력 다이오드 레이저를 이용한 프레스 전단금형의 경화특성)

  • Hwang, Hyun-Tae;So, Sang-Woo;Hwang, Jae-Hyun;Kim, Jong-Do
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.23 no.5
    • /
    • pp.257-262
    • /
    • 2010
  • Recently, metal molding has become essential not only for automobile parts, but also mass production, and has greatly influenced production costs as well as the quality of products. Its surface has been treated by carburizing, nitriding and induction hardening, but these existing treatments cause considerable deformation and increase the expense of postprocessing after treatment; furthermore, these treatments cannot be easily applied to parts that requiring the hardening of only a certain section. This is because the treatment cannot heat the material homogeneously, nor can it heat all of it. Laser surface treatment was developed to overcome these disadvantages, and, when the laser beam is irradiated on the surface and laser speed is appropriate, the laser focal position is rapidly heated and the thermal energy of surface penetrates the material after irradiation, finally imbuing it with a new mechanical characteristic by the process of self-quenching. This research estimates the material characteristic after efficient and functional surface treatment using HPDL, which is more efficient than the existing CW Nd:YAG laser heat source.

Flip-chip Bonding Using Nd:YAG Laser (Nd:YAG 레이저를 이용한 Flipchip 접합)

  • Song, Chun-Sam;Ji, Hyun-Sik;Kim, Jong-Hyeong;Kim, Joo-Hyun;Kim, Joo-Han
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.1
    • /
    • pp.120-125
    • /
    • 2008
  • A flip-chip bonding system using DPSS(Diode Pumped Solid State) Nd:YAG laser(wavelength : 1064nm) which shows a good quality in fine pitch bonding is developed. This laser bonder can transfer beam energy to the solder directly and melt it without any physical contact by scanning a bare chip. By using a laser source to heat up the solder balls directly, it can reduce heat loss and any defects such as bridge with adjacent solder, overheating problems, and chip breakage. Comparing to conventional flip-chip bonders, the bonding time can be shortened drastically. This laser precision micro bonder can be applied to flip-chip bonding with many advantage in comparison with conventional ones.

The SEM and SPM Study on the Change of Machined Titanium Implant Surface following Various Laser Treatments (수종의 레이저로 임프란트 표면 처리 시 표면 형태의 변화에 대한 주사전자 및 주사탐침 현미경적 연구)

  • Kim, In-Kyung;Chung, Chin-Hyung;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.2
    • /
    • pp.451-463
    • /
    • 2001
  • Following the extensive use of implant, the incidence of peri-implantitis increases. Guided bone regeneration has been used for the optimal treatment of this disease. Because implant surface was contaminated with plaque and calculus, cleaning and detoxification were needed for the reosseointegration when guided bone regeneration was performed. Various mechanical and chemical methods have been used for cleaning and detoxification of implant surface, air-powder abrasive and oversaturated citrate were known to be most effective among these methods. However, these methods were incomplete because these could not thoroughly remove bacteria of implant surface, moreover deformed implant surface. Recent studies for detoxification of the implant surface using laser were going on, $CO_2$ laser and Soft Diode laser were known to be effective among these methods. The purpose of this study was to obtain clinical guide by application these laser to implant surface. 15 experimental machined pure titanium cylinder models were fabricated. The $CO_2$ laser treatment under dry, wet and hydrogen peroxide condition or the Soft Diode laser treatment under Toluidine blue O solution condition was performed on the each of models. Each groups were examined with SPM and SEM to know whether their surface was changed. The results were as follows : 1. Surface roughness and surface form weren't changed when $CO_2$ laser was usedunder dry condition(P>0.05). 2. Surface roughness and surface form weren't changed when $CO_2$ laser was used under wet condition(P>0.05). 3. Surface roughness and surface form weren't changed when $CO_2$ laser was used under hydrogen peroxide condition(P>0.05). 4. Surface roughness and surface form weren't changed when Soft Diode laser was used under toluidine blue O solution condition(P>0.05). From the result of this study, it may be concluded that the $CO_2$ laser having relatively safe pulse mode and the Soft Diode laser used with photosensitizer can be used safely to treat peri-implantitis.

  • PDF

Numerical Study on the Wireless Communication at 550[nm], 850[nm] and 1550[nm] Wavelength LD in Fog and Pointing Error using Cassegrain Optics (카세그레인 광학계를 사용한 광무선통신 시스템에서 550[nm], 850[nm] 및 1550[nm]의 광 파장에 대한 안개 및 포인팅의 에러의 영향에 대한 해석)

  • Hong, Kwon-Eui
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.164-175
    • /
    • 2008
  • Atmospheric effects on laser beam propagation can be broken down into two categories: attenuation of the laser power and fluctuation of laser power due to laser beam deformation. Attenuation consists of scattering of the laser light photons by the fog. Laser beam deformation occurs because of small-scale dynamic changes in the index of refraction of the atmosphere. This causes pointing error. In order to analyse these effect on optical wireless communication system, in this paper uses cassegrain optics as a transmitting and receiving telescope, AID as a detecting device and ill as a light source. The signal modulating and demodulating method is a IM/DD. I show the effects of fog and pointing error and calculate the possible communication distance for BER is $10^{-9}$.

Absolute Positioning System of Mobile Robot using Light Navigation Path (광궤도를 이용한 이동로봇의 절대위치 보정 시스템)

  • 박용택;정효용;국금환
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.10
    • /
    • pp.141-147
    • /
    • 2003
  • This paper represents an absolute positioning system using a light navigation path for mobile robot. The absolute positioning system is composed of the projector unit which generates a laser beam using laser diode and mobile robot with the optical detector which has some optical sensors. The projector unit is fixed over the navigating plane of mobile robot to generate the light navigation path, and the optical detector located upper part of mobile robot detects the generated laser beam from the projector. The navigation of mobile robot is controlled by the micro-processor which compares the detected present position from the detector with the previously programmed navigation path. And experimental results show that our sensor system can be used for the absolute positioning system of the mobile robot.

The performance of Bio-aerosol Detection System (BDS) with 405 nm laser diode (405 nm 광원을 이용한 생물입자탐지기의 에어로졸 분석성능)

  • Jeong, Young-Su;Chong, Eugene;Lee, Jong-Min;Choi, Kibong
    • Particle and aerosol research
    • /
    • v.13 no.1
    • /
    • pp.25-31
    • /
    • 2017
  • This paper offer the characteristics for the detection and classification of biological and non-biological aerosol particles in the air by using laser-induced-fluorescence (LIF) based Bio-aerosol Detection System (BDS). The BDS is mainly consist of an optical chamber, in-outlet nozzle system, 405 nm diode laser, an avalanche photo detector (APD) for scattering signal and photomultiplier tubes (PMT) for fluorescence signals in two different wavelength range ; F1, 510-600 nm and F2, 435-470 nm. The detection characteristics, especially ratio of fluorescence signal intensity were examined using well-known components : polystylene latex (PSL), fluorescence PSL, $2{\mu}m$ of SiO2 micro sphere, dried yeast, NADH, ovalbumin, fungicide powder and standard dust. The results indicated that the 405 nm diode laser-based LIF instrument can be a useful bio-aerosol detection system for unexpected biological threaten alter in real-time to apply for dual-use technology in military and civilian fields.

A Study on the Lightwave off-set Locking using Frequency Difference Detector (주파수 차이 검출기를 이용한 광파의 off-set 주파수 로킹 연구)

  • 유강희
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.484-493
    • /
    • 2004
  • A new lightwave locking technique which can be used in tuning the wavelength of a local laser diode to the reference wavelength is presented in this paper. The optical frequency from the reference laser source and the optical frequency from the local slave VCO laser are heterodyned on a optical receiver, resulting in the 1.5GHz RF signal corresponding to the difference frequency between two input optical signals. The difference frequency is locked to the reference 1.5GHz oscillator source in off-set frequency locking loop. Using the commercialized microwave components, frequency difference detector can be easily established to lock the lightwave. The optical frequency of 1.55um laser diode which keeps the frequency off-set of 1.5GHz is locked to the input reference optical signal with the locking range of 320MHz.