• Title/Summary/Keyword: TMA 모델

Search Result 12, Processing Time 0.027 seconds

An Ocean Wave Simulation Method Using TMA Model (TMA 모델을 이용한 해양파 시뮬레이션 방법)

  • Lee Nam-Kyung;Baek Nakhoon;Kim Ku Jin;Ryu Kwan Woo
    • The KIPS Transactions:PartA
    • /
    • v.12A no.4 s.94
    • /
    • pp.327-332
    • /
    • 2005
  • In the field of computer graphics, we have several research results to display the ocean waves on the screen, while we still not have a complete solution yet. Though ocean waves are constructed from a variety of sources, the dominant one is the surface gravity wave, which is generated by the gravity and the wind. In this Paper, we Present a real-time surface gravity wave simulation method, derived from a precise ocean wave model in the oceanography. There are research results based on the Pierson-Moskowitz(PM) model[1], which assumes infinite depth of water and thus shows some mismatches in the case of shallow seas. In this paper, we started from the Texel, Marsen and Arsloe(TMA) model[2], which is a more precise wave model and thus can be used to display more realistic ocean waves. We derived its implementation model for the graphics applications and our prototype implementation shows about 30 frames per second on the Intel Pentium 4 1.6GHz-based personal computer. Our major contributions to the computer graphics area ill be (1) providing more user-controllable parameters to finally generate various wave shapes and (2) the improvement on the expression power of waves even in the shallow seas.

Target motion analysis algorithm using an acoustic propagation model in the ocean environment of South Korea (한국 해양환경에서 음파전달모델을 이용한 표적기동분석 알고리즘)

  • Seo, Ki Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.387-395
    • /
    • 2019
  • TMA (Target Motion Analysis) in passive sonar is generally conducted with the bearing only or the bearing frequency. In order to conduct TMA fast and accurately, it is essential to estimate a initial target maneuver precisely. The accuracy of TMA can be improved by using SNR (Signal to Noise Ratio) information and acoustic propagation model additionally. This method assumes that the radiated noise level of the target is known, but the accuracy of TMA can be degraded due to a mismatch between the assumed radiated noise level and the actual radiated noise level. In this paper, TMA with the acoustic propagation model, bearing measurements, and SNR information is conducted in the ocean environment of South Korea (East Sea/ Yellow Sea/ South Sea). And the performance analysis of TMA for the mismatch in the radiated noise is presented.

Effect of Brine Mineral Water on TMA-Induced Contact Hypersensitivity Reaction in the Mouse Model (TMA로 유도된 접촉성 과민 반응 마우스 질환모델에서 해양성 광천수 도포시의 치료효과)

  • Kim, Jae-Jin;Kim, Wan-Jae;Sim, Jae-Man;Choi, Seon-Kang;Kwon, Soon-Sung;Kim, Jung-Duk;Lee, Kwang-Ho
    • The Korean Journal of Food And Nutrition
    • /
    • v.23 no.4
    • /
    • pp.440-445
    • /
    • 2010
  • Effect of brine mineral water(BMW) on contact hypersensitivity reaction(CHR) was estimated using trimellitic anhydride (TMA) induced CHR in the mouse. BMW exhibited potent inhibitory activity on TMA induced CHR. BMW treatment suppressed the ear swelling, and attenuated hyper-activated lymph nodes stimulated by TMA challenge, thereby reduced their weight. The immunological index was analyzed after BMW administration in CHR. The level of serum IgE was significantly down regulated after BMW treatment. Furthermore, BMW showed inhibitory property of cytokine production. BMW treatment suppressed not only Th2 type cytokine, IL-4 but also pro-inflammatory cytokines such as TNF-${\alpha}$ and IL-6. From the histological analysis, the inflammatory context appeared by atopic dermatitis lesion after challenging with TMA are diminished by BMW treatment. Our results suggest that BMW may attenuate the development of CHR, and can be available for functional ingredient.

Evaluation of Beef Freshness Using Visible-near Infrared Reflectance Spectra (가시광선-근적외선 반사스펙트럼을 이용한 쇠고기의 신선도 평가)

  • Choi, Chang-Hyun;Kim, Jong-Hun;Kim, Yong-Joo
    • Food Science of Animal Resources
    • /
    • v.31 no.1
    • /
    • pp.115-121
    • /
    • 2011
  • The objective of this study was to develop models to predict freshness factors (total viable counts (TVC), pH, volatile basic nitrogen (VBN), trimethylamine (TMA), and thiobarbituric acid (TBA) values) and the storage period in beef using a visible and near-infrared (NIR) spectroscopic technique. A total of 216 beef spectra were collected during the storage period from 0 to 14 d at a $10^{\circ}C$ storage. A spectrophotometer was used to measure reflectance spectra from beef samples, and beef freshness spectra were divided into a calibration set and a validation set. Multi-linear regression (MLR) models using the stepwise method were developed to predict the factors. The MLR results showed that beef freshness had a good correlation between the predicted and measured factors using the selected wavelength. The correlation of determination ($r^2$), standard error of prediction (SEP), and ratio of standard deviation to SEP (RPD) of the prediction set for TVC was 0.74, 0.64, and 2.75 Log CFU/$cm^2$, respectively. The $r^2$, SEP, and RPD values for pH were 0.43, 0.10, and 1.10; those for VBN were 0.73, 1.45, and 2.00 mg%; those for TMA were 0.70, 0.19, and 2.58 mg%; those for TBA values were 0.73, 0.13, and 2.77 mg MA/kg; and those for storage period were 0.77, 1.94, and 2.53 d, respectively. The results indicate that visible and NIR spectroscopy can predict beef freshness during storage.

Three-dimensional finite element analysis on the effect of maxillary incisor torque (상악 절치부-토크에 의한 치아 이동과 응력 분포에 관한 유한요소법적 연구)

  • Yoon, Hyun-Joo;Lim, Yong-Kyu;Lee, Dong-Yul;Jo, Yung-Soo
    • The korean journal of orthodontics
    • /
    • v.35 no.2 s.109
    • /
    • pp.137-147
    • /
    • 2005
  • The purpose of this study was to investigate the stress distribution in the periodontal tissue and the displacement of teeth when active torque was applied to the maxillary incisors by three-dimensional finite element analysis A three-dimensional finite element model consisted of the maxillary teeth and surrounding periodontal membrane, $.022{\times}.028$ Roth prescription bracket and stainless steel, NiTi and TMA rectangular ideal arch wires which were modeled by hexahedron elements. Applied active torques were 2, 5 and 10 degrees ThHe findings of this study showed that the reaction force acting or the bracket was the extrusion force on the mesial side of the incisors and canine and the intrusion force on the distal side of the incisors and canine. The amount of force and moment was greatest at the lateral incisor. When active anterior labial crown torque was applied. labial crown and distal tipping and Intrusion of the incisors took place. and lingual crown distal tipping and extrusion of the canine occured. An excessive force was concentrated on the lateral incisor, when the stainless steel wire was used NiTi or TMA wire is desirable for torque control.

Influence of Nitrite and Ascorbic acid on N-Nitrosamine Formation during the Fermentation of Salt-fermented Small Shrimp (새우젓 숙성중 아질산염과 아스코르브산이 N-Nitrosamine의 생성에 미치는 영향)

  • KIM Jeong-Gyun;LEE Soo-Jung;SUNG Nak-Ju
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.1
    • /
    • pp.63-70
    • /
    • 1998
  • The changes of contents of trimethylamine oxide nitrogen (TMAO-N), trimethylamine nitrogen (TMA-N), dimethylamine nitrogen (DMA-N), nitrite nitrogen (nitrite-N), nitrate nitrogen (nitrate-N) and N-nitrosamine (NA) of salt-fermented small shrimp were investigated during fermentation. The contents of TMAO-N decreased, while TMA-N and DMA-N increased during fermentation in all samples. Contents of nitrite-N decreased in the samples supplemented with sodium nitrite during fermentation, whereas the formation of N-nitrosodimethylamine (NDMA) increased. Treatment of ascorbic acid revealed inhibiting effort on NDMA formation compared with the control. The model system was used for the evaluation of ascorbic acid (inhibitor) or thiocyanate (promoter) on the formation of NDMA using salt-fermented small shrimp supplemented with sodium nitrite, The optimum pH for the formation of NDMA was 3.5, and ascorbic acid inhibited the formation of NDMA whereas thiocyanate promoted.

  • PDF

Influence of Nitrite and Ascorbic Acid on N-Nitrosamine Formation during Fermentation of Salted Anchovy (멸치젓 숙성중 아질산염과 아스코르브산이 N-Nitrosamine의 생성에 미치는 영향)

  • 김정균;이수정;성낙주
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.26 no.4
    • /
    • pp.606-613
    • /
    • 1997
  • The changes of contents in trimethylamine oxide nitrogen(TMAO-N), trimethylamine nitrogen(TMA-N), dimethylamine nitrogen(DMA-N), nitrite nitrogen(nitrite-N), nitrate nitrogen(nitrate-N) and the effect on the formation of N-nitrosamine(NA) during fermentation were investigated with salted anchovy added different amounts of sodium nitrite, sodium nitrate and ascorbic acid, respectively. When the sodium nitrite was added in salted anchovy, the contents of nitrite-N was decreased during fermentation . Whereas the formation of N-nitrosodimethylamine(NDMA ) was increased . Contents of TMAO-N was decreased, while TMA-N and DMA-N were increased during fermentation in all samples. Addition of ascorbic acid inhibited the formation of NDMA significantly. The formation of NDMA was inhibited by 81.3% at the concentration of 130mM as compared with non-added the control group. The aqueous model system was used for the evaluation of ascorbic acid(inhibitor) or thiocyanate (promoter) on the formation of NDMA using salt-fermented anchovy added with sodium nitrite. The optimum pH on the formation of NDMA was shown to be 3.8, and ascorbic acid inhibited the formation of NDMA whereas thiocyanate promoted. NDMA was not detected in the salt-fermented anchovy (control sample). However it is a possibility to form carcinogenic NDMA in stomach if both saltfer-mented anchovy and the materials contained abundant nitrite or nitrate were took in.

  • PDF

A FEM study about the initial stress distribution on canine altered by the application point of preangulated TMA T-loop spring (Preangulated TMA T-loop spring의 적용 위치 변화에 따른 견치의 초기 응력 분포에 대한 유한 요소법적 연구)

  • Kim, Jung-Min;Cha, Kyung-Suk;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.521-534
    • /
    • 1999
  • The purpose of this study was to find the difference of stress distribution on canine altered by the application point of preangulated T-loop spring. For this study, the finite element models of upper left canine, upper left second premolar and upper left first molar were made. Also, the finite element models of $0.017{\times}0.025$ inch preangulated, preactivated T-loop spring and $0.018{\times}0.025$ inch stainless steel wire were made. Three types of T-loop spring were made . the middle of activated T-loop is positioned in accordance with the middle position of distance of bracket position of both the canine and first molar, 2mm anterior, 2mm posterior. We compared the forces and the distribution of stress that were generated by the difference of position of T-loop spring. The results were as follows. 1. All of the 3 types of T-loop spring showed the similar retraction forces. 2. All showed the similar amount & pattern of stress distribution. 3. The centers of rotation of canine in 3 types of T-loop spring were same and were positioned between C and D plane. 4. The canine showed the intrusive force by 2mm anterior positioned T-loop spring, but the extrusive force by 2mm posterior positioned T-loop suing. Neverthless, because of the small amount of the forces, the effect of vertical force was not significant.

  • PDF

The moment generated by the torque of the orthodontic rectangular wire : Three-dimensional finite element analysis (교정용 각형선재에 부여된 torque가 브라켓에 발생시키는 모멘트에 관한 유한요소법적 분석)

  • Ha, Do-Won;Kim, Young-Suk;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.31 no.3 s.86
    • /
    • pp.335-346
    • /
    • 2001
  • The purpose of this study was to investigate the ideal clinical torque(In the SWA rectangular wire, the torque by the angle between the plane part and twisted part to move the tooth) of the orthodontic rectangular wire which produce the proper labiolingual movement of the single tooth during finishing stage of the orthodontic treatment. The clinical torque is the sum of the play and the active torque which generates the moment at the bracket. The play is calculated by the formula and the active torque is calculated by the computer aided three-dimensional finite element method. The finite element model was consist of the three brackets which formed a row and 3 kinds of orthodontic rectangular wire(stainless steel, TMA, NiTi) which inserted in brackets. Both sides of the model were twisted and the moment generated in the center bracket was calculated. The sizes of seven wires which were used commonly were .016'X.022', .017'X.022', .017'X.025', .018'X.025', .019'X.025', .020'X.025', .021'X.025'. In 018' bracket, 016'X.022', .017'X.022', .017'X.025' wires were inserted and in 022' bracket, all the sizes of wires except .016'X.022' were inserted and tested. The following conclusions could be drawn from this study. 1. The moments generated on the same size of the wires by the same active torque were equal regardless of the bracket slot size. 2. The moments were increased with the size of the wires. The moment generated on the .021'X.025' wire was about 1.75 times as large as that on the .016'X.022' wire regardless of the material. 3. The moments were increased in the order of the NiTi, TMA stainless steel. The moment of the TMA wire was 0.35 times as small as that of the stainless steel wire and the moment of the NiTi was0.16 times as small as that of the stainless steel wire. 4. The moment was decreased as the interbracket distance was increased. 5. To get a desired moment with the specific size and material of the wire on the specific bracket slot, the formula and the results were displayed.

  • PDF

MOving Spread Target signal simulation (능동 표적신호 합성)

  • Seong, Nak-Jin;Kim, Jea-Soo;Lee, Snag-Young;Kim, Kang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.30-37
    • /
    • 1994
  • Since the morden targets are of high speed and getting quiet in both active and passive mode, the necessities of developing advanced SONAR system capable of performing target motion analysis (TMA) and target classification are evident. In order to develop such a system, the scattering mechanism of complex bodies needs to be, some extent, fully understood and modeled. In this paper, MOving Spread Target(MOST) signal simulation model is presented and discussed. The model is based on the highlight distribution method, and simulates pulse elongation of spread target, doppler effect due to kinematics of the target as well as SONAR platform, and distribution target strength of each highlight point (HL) with directivity. The model can be used in developing and evaluating advanced SONAR system through system simulation, and can also be used in the development of target state estimation algorithm.

  • PDF