• Title/Summary/Keyword: TM

Search Result 4,088, Processing Time 0.044 seconds

Functions of a-Tropomyosin Are Mainly Dependent upon the Local Structures of the Amino Terminus (a-Tropomyosin의 아미노 말단 구조가 기능에 미치는 영향)

  • Cho, Young-Joon
    • Journal of Life Science
    • /
    • v.14 no.5
    • /
    • pp.770-777
    • /
    • 2004
  • It has been previously reported that unacetylated a-tropomyosin(TM) produced in E. coli failed to bind to actin while acetylated muscle TM and Ala-Ser dipeptide fusion TM (AS-TM) bound well to actin. In order to determine the structural requirement of the amino terminus for high actin affinity, a recombinant tropomyosin (Ala-TM) that a single Ala residue was added to the amino terminus of Ala-TM was constructed, overexpressed, and purified from E. coli. Actin affinity of Ala-TM was 2.3$\times$$10^{6}$$M^{-1}$, whereas that of unacetylated TM was considerably lower than 0.1$\times$$10^{-6}$$M^{-1}$ indicating that addition of a single Ala residue to the amino terminus drastically increased, at least twenty times, actin affinity of TM. Ala-TM, however, bound to actin about three times weaker than acetylated TM and AS- TM, implying that the addition of an Ala residue was insufficient for complete restoration of high actin affinity. While Ala-TM, AS-TM, and muscle TM showed inhibition and activation of actomyosin Sl ATPase activity depending on myosin Sl concentration, the degree of inhibition and activation was different from each other. AS-TM exhibited the greatest inhibition of the ATPase at low Sl concentration, whereas the greatest activation of the ATPase was observed with muscle TM. These results, together with previous findings, strongly suggested that local structure of the amino terminus is the crucial functional determinant of TM.

Remineralization Effects on the Demineralized Enamel of Primary Teeth by Fluoride Varnish (불소바니쉬에 의한 탈회 유전치 법랑질의 재광화 효과)

  • Cho, Seongeun;Kim, Jongbin;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.1
    • /
    • pp.44-50
    • /
    • 2016
  • The purpose of this study was to compare and evaluate the remineralization effect of three types of fluoride varnishes on demineralized enamel of primary teeth. 40 primary teeth were decalcified by soaking them in artificial acidic solution and stored at $37^{\circ}C$ for 7 days. Then 3 varnishes - Cavity shield$^{TM}$, V varnish$^{TM}$ and MI varnish$^{TM}$ were applied respectively one time a week, for 3 weeks on the demineralized enamel surface. For the first week, MI varnish$^{TM}$ showed the highest microhardness value, V varnish$^{TM}$ was in second position, and Cavity shield$^{TM}$ showed the lowest microhardness value. However, there was no significant difference among the three groups(p > 0.05). For the second week, V varnish$^{TM}$ showed the highest microhardness value, and MI varnish$^{TM}$ came next in second position noting no significant difference (p > 0.05). Cavity shield$^{TM}$ was significantly lower than the other groups (p < 0.05). For the third week, V varnish$^{TM}$ showed the highest microhardness value, noting a significant difference from the other groups (p < 0.05). MI varnish$^{TM}$ came next, while Cavity shield$^{TM}$ showed the lowest microhardness value. However, there was no significant difference between MI varnish$^{TM}$ and Cavity shield$^{TM}$ (p > 0.05). The increase in the microhardness of groups V varnish$^{TM}$ and MI varnish$^{TM}$ were higher than that of group Cavity shield$^{TM}$ (p < 0.05), while no significant difference was noted between groups V varnish$^{TM}$ and MI varnish$^{TM}$ (p > 0.05).

A Study on the Comparison of LANDSAT-5 TM and MSS Data -laying stress on the landuse mapping of Incheon area- (LANDSAT-5의 TM과 MSS 데이타의 비교에 관한 연구 -인천지역의 토지이용분류를 중심으로-)

  • 안철호;박병욱
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.4 no.2
    • /
    • pp.27-41
    • /
    • 1986
  • In this study, practical use of TM (Thematic Mapper) data was evaluated by comparison of LANDSAT- 5 TM and MSS (Multispectral Scanner) data. The comparison of TM and MSS data was achieved by analyzing the result of landuse mapping of Incheon area, and in addition, the comparison of accuracy according to image enhancement method was made. From the results of this study, we found that TM data was more accurate by about 20% than MSS data in landuse mapping, and that smoothing was effective in image enhancement processing of TM data.

  • PDF

Gas Permeation Properties of Carbon Dioxide and Methane for $PEBAX^{TM}$/TEOS Hybrid Membranes ($PEBAX^{TM}$/TEOS 하이브리드 분리막을 통한 이산화탄소와 메탄의 기체투과특성)

  • Kim, Hyunjoon
    • Korean Chemical Engineering Research
    • /
    • v.49 no.4
    • /
    • pp.460-464
    • /
    • 2011
  • Poly(ether-block-amide)(PEBA, $PEBAX^{TM}$) resin is a thermoplastic elastomer combining linear chains of hard-rigid polyamide block interspaced soft-flexible polyether block. It was believed that the hard polyamide block provides the mechanical strength and permeation selectivity, whereas gas transport occurs primarily through the soft polyether block. The objective of this work was to investigate the gas permeation properties of carbon dioxide and methane for $PEBAX^{TM}$-1657 membrane and compare with those obtained for other grade of $PEBAX^{TM}$, $PEBAX^{TM}$-2533. And the organic/inorganic hybrid membranes were prepared using $PEBAX^{TM}$ and TEOS(tetraethoxysilane) by sol-gel process, and gas permeation properties were studied. $PEBAX^{TM}$-2533 membrane exhibited higher gas permeability coefficients than $PEBAX^{TM}$-1657 membrane. This was explained by the increase of chain mobility. The permeability coefficients for $PEBAX^{TM}$/TEOS hybrid membranes were higher than pure $PEBAX^{TM}$ membranes. This results were explained by the reduction of crystallinity of polyamide block by the introduction of TEOS. Ideal separation factor of hybrid membranes does not change much. This might be due to the increase of solubility selectivity.

COMPARATIVE STUDY ON THE SHEAR BOND STRENGTH OF ALL-IN-ONE DENTIN BONDING SYSTEM APPLIED TO PRIMARY TEETH (유치에 적용된 All-in-One 상아질 접착 시스템의 전단강도에 관한 비교연구)

  • Kim, Dong-Cheol;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.4
    • /
    • pp.560-568
    • /
    • 2007
  • This study was performed to compare the shear bond strength of primary enamel & dentin treated by AQ Bond $Plus^{TM}$ and G $Bond^{TM}$, recently developed 6th generation dentin bonding system, to that of Single $Bond^{TM}$ being widely used. Also by observing the resin tag under scanning electron microscope, Resin tags of each material were also observed under scanning electron microscope and compared to one another. The possibility of clinical application of All-in-One system which has an advantage to reduce chair-time for children with difficult behavior pattern was evaluated. The results obtained are as follows: 1. No statistically significant difference between groups was found in shear bond strength of primary enamel. 2. In primary dentin, the shear bond strength of AQ Bond $Plus^{TM}$ was $1.15\;{\pm}\;0.37\;MPa$, G $Bond^{TM}$ was $1.69\;{\pm}\;0.74\;MPa$ and Single $Bond^{TM}$ was $0.56\;{\pm}\;0.11\;MPa$. There were no statistical difference between AQ Bond $Plus^{TM}$ and G $Bond^{TM}$ and between G $Bond^{TM}$ and Single $Bond^{TM}$, whereas statistically significant difference was found between AQ Bond $Plus^{TM}$ and Single $Bond^{TM}$. 3. Under scanning electron microscope, resin tags observed in AQ Bond $Plus^{TM}$ and G $Bond^{TM}$ were very weak and tangled while strong and thick tags were shown with many lateral branches in Single $Bond^{TM}$. The result of the present study coupled with the advantages of less working time over the previous generation suggests that All-in-One system might be effectively used in adhesive dental procedures for primary teeth.

  • PDF

Effect of Preharvest and Postharvest 1-Methylcyclopropene (1-MCP) Treatments on Fruit Quality Attributes in Cold-stored 'Fuji' Apples (수확 전·후 1-MCP처리가 '후지' 사과의 저온저장 중 과실품질에 미치는 영향)

  • Yoo, Jingi;Kang, Bong Kook;Lee, Jinwook;Kim, Dae Hyun;Lee, Dong Hoon;Jung, Hee-Young;Choi, DongGeun;Choung, Myoung-Gun;Choi, In Myung;Kang, In-Kyu
    • Horticultural Science & Technology
    • /
    • v.33 no.4
    • /
    • pp.542-549
    • /
    • 2015
  • This work was carried out to evaluate the effects of preharvest 1-methylcyclopropene (1-MCP, $Harvista^{TM}$) and postharvest 1-MCP ($SmartFresh^{TM}$) treatments on the fruit quality attributes of cold-stored 'Fuji' ( Malus domestica Borkh.) apples. Fruits were exposed to 0, 95, 125, or $250 mg{\cdot}L^{-1}$ $Harvista^{TM}$ at 3, 2, 1 weeks before harvest (WBH), and treated with 0 or $1{\mu}{\cdot}L^{-1}$ $SmartFresh^{TM}$ at harvest. Fruit was then stored for up to 180 days at $0{\pm}1^{\circ}C$. Fruit fresh weight, Hunter's value a, internal ethylene concentration (IEC), flesh firmness, titratable acidity (TA), and soluble solids content (SSC) in fruit treated with $Harvista^{TM}$ were not different from those of control fruit at harvest. During cold storage, flesh firmness and TA were higher in fruit treated with $250mg{\cdot}L^{-1}$ $Harvista^{TM}$ at 2 and 3 WBH than in control fruit. IEC was 5.5-10.0% lower in fruit treated with $250mg{\cdot}L^{-1}$ $Harvista^{TM}$ at 2 and 3 WBH compared with control fruit as storage duration progressed, while SSC was not affected. Furthermore, flesh firmness, TA, and IEC were affected neither by $Harvista^{TM}$ nor $Harvista^{TM}+SmartFresh^{TM}$ treatments, compared with those fruit quality attributes at harvest. The correlation maps indicated that IEC was negatively correlated with firmness and TA, regardless of $Harvista^{TM}$ application levels. In addition, positive correlations between fruit quality attributes were detected in treatments with $250mg{\cdot}L^{-1}$ $Harvista^{TM}+SmartFresh^{TM}$. Therefore, the results suggest that with a single application of $SmartFresh^{TM}$, a higher level of $Harvista^{TM}$ application would help in retention of fruit quality attributes during cold storage.

The Effect of Aging Treatment for Microleakage within Composite Resin Restoration (시효처리가 복합레진 수복물의 미세누출에 미치는 영향에 관한 연구)

  • Yoo, Seunghoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.4
    • /
    • pp.283-295
    • /
    • 2013
  • In this study, researchers tried to find the effect, if any, of aging treatment to the specimens with three different dentin bonding agents using MicroCT. One, 5th generation - [Adper$^{TM}$ Single bond Plus] and two 6th generation [AdheSE$^{(R)}$, Adper$^{TM}$ Prompt$^{TM}$ L-Pop$^{TM}$] dentin bonding agents were used in this study. Specimens were divided into 4 groups according to aging treatment method used. Group I : control group, Group II : thermocycled between $5^{\circ}C$ and $55^{\circ}C$ for 60 seconds dwell time 5,000 times, Group III : aged as Group II and artificially brushed 20,000 times, Group IV : aged as Group III and were stored in artificial saliva for 6 months. With Single bond Plus, Group II showed more microleakage than Group I (p < 0.05). Group II and Group III showed more microleakage than Group IV (p < 0.05). There were no statistically significant differences among the groups using AdheSE$^{(R)}$ and Prompt$^{TM}$ L-Pop$^{TM}$ (p > 0.05). Among Group I, AdheSE$^{(R)}$ showed more microleakage than Single bond Plus and Prompt$^{TM}$ L-Pop$^{TM}$ (p < 0.05). Among Group II, there were no statistically significant differences (p > 0.05). Among Group III, AdheSE$^{(R)}$ showed more microleakage than Single bond Plus and Prompt$^{TM}$ L-Pop$^{TM}$ (p < 0.05). Among Group IV, AdheSE$^{(R)}$ and Prompt$^{TM}$ L-Pop$^{TM}$ showed more microleakage than Single bond Plus (p < 0.05).

An Analysis of the Landuse Classification Accuracy Using IHS Merged Images from IRS-1C PAN Data and Landsat TM Data (IRS-1C PAN 데이터와 Landsat TM 데이터의 IHS중합화상을 이용한 토지이용분류 정확도 분석)

  • 안기원;이효성;서두천;신석효
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.16 no.2
    • /
    • pp.187-194
    • /
    • 1998
  • In this study, effective multispectral Landsat TM band combinations for a merging with the high resolution IRS-1C PAN data using the IHS method to improve landuse accuracy is discussed. From the pre-classified image using the merged images with TM all six band images(with the exception of band 6 image) and PAN image, a sample data which has ten classes was generated. An evaluation of the overall classification accuracy for the representative seven merged images which were merged using each TM three-band images and IRS-1C PAN image by IHS method for the sample area. The increase in classification accuracy is most significant with the inclusion of two of TM4, TM5 and TM7 infrared band images. Especially, the largest increase(11.8 percent) in landuse classification accuracy were investigated when Landsat TM247 bands were merged with IRS-1C PAN data. The classification accuracy when TM three band image and PAN image were used without merging is higher than result of the case of using the merged images.

  • PDF

The Comparative Study of on Pump CABG during Pulsatile $(T-PLS^{TM})$ and Nonpulsatile $(Bio-pump^{TM})$ Perfusion (관상동맥우회술 시 사용된 박동성펌프$(T-PLS^{TM})$와 비박동성펌프$(Bio-pump^{TM})$의 비교연구)

  • Park Young-Woo;Her Keun;Lim Jae-Ung;Shin Hwa-Kyun;Won Yong-Soon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.354-358
    • /
    • 2006
  • Background: Pulsatile pumps for extracorporeal circulation have been known to be better for tissue perfusion than non-pulsatile pumps but be detrimental to blood corpuscles. This study is intended to examine the risks and benefits of $T-PLS^{TM}$ through the comparison of clinical effects of $T-PLS^{TM}$ (pulsatile pump) and $Bio-pump^{TM}$ (non-pulsatile pump) used for coronary bypass surgery. Material and Method: The comparison was made on 40 patients who had coronary bypass using $T-PLS^{TM}\;and\;Bio-pump^{TM}$ (20 patients for each) from April 2003 to June 2005. All of the surgeries were operated on pump beating coronary artery bypass graft using cardiopulmonary extra-corporeal circulation. Risk factors before surgery and the condition during surgery and the results were compared. Result: There was no significant difference in age, gender ratio, and risk factors before surgery such as history of diabetes, hypertension, smoking, obstructive pulmonary disease, coronary infarction, and renal failure between the two groups. Surgery duration, hours of heart-lung machine operation, used shunt and grafted coronary branch were little different between the two groups. The two groups had a similar level of systolic arterial pressure, diastolic arterial pressure and mean arterial pressure, but pulse pressure was measured higher in the group with $T-PLS^{TM}\;(46{\pm}15\;mmHg\;in\;T-PLS^{TM}\;vs\;35{\pm}13\;mmHg\;in\;Bio-pump^{TM},\;p<0.05)$. The $T-PLS^{TM}$-operated patients tended to produce more urine volume during surgery, but the difference was not statistically significant $(9.7{\pm}3.9\;cc/min\;in\;T-PLS^{TM}\;vs\;8.9{\pm}3.6\;cc/min\;in\;Bio-pump^{TM},\;p=0.20)$. There was no significant difference in mean duration of respirator usage and 24-hour blood loss after surgery between the two groups. Plasma free Hb was measured lower in the group with $T-PLS^{TM}\;(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;versus\;46.8{\pm}23.0mg/dL\;in\;Bio-pump^{TM},\;p<0.05)$. There was no significant difference in coronary infarction, arrhythmia, renal failure and morbidity rate of cerebrovascular disease. There was a case of death after surgery (death rate of 5%) in the group tested with $T-PLS^{TM}$, but the death rate was not statistically significant. Conclusion: Coronary bypass was operated with $T-PLS^{TM}$ (Pulsatile flow pump) using a heart-lung machine. There was no unexpected event caused by mechanical error during surgery, and the clinical process of the surgery was the same as the surgery for which $Bio-pump^{TM}$ was used. In addition, $T-PLS^{TM}$ used surgery was found to be less detrimental to blood corpuscles than the pulsatile flow has been known to be. Authors of this study could confirm the safety of $T-PLS^{TM}$.

Self-renewal and circulating capacities of metastatic hepatocarcinoma cells required for collaboration between TM4SF5 and CD44

  • Lee, Doohyung;Lee, Jung Weon
    • BMB Reports
    • /
    • v.48 no.3
    • /
    • pp.127-128
    • /
    • 2015
  • Tumor metastasis involves circulating and tumor-initiating capacities of metastatic cancer cells. Hepatic TM4SF5 promotes EMT for malignant growth and migration. Hepatocellular carcinoma (HCC) biomarkers remain unexplored for metastatic potential throughout metastasis. Here, novel TM4SF5/CD44 interaction-mediated self-renewal and circulating tumor cell (CTC) capacities were mechanistically explored. TM4SF5-dependent sphere growth was correlated with $CD133^+$, $CD24^-$, ALDH activity, and a physical association between CD44 and TM4SF5. The TM4SF5/CD44 interaction activated c-Src/STAT3/ Twist1/ B mi1 signaling for spheroid formation, while disturbing the interaction, expression, or activity of any component in this signaling pathway inhibited spheroid formation. In serial xenografts of less than 5,000 cells/injection, TM4SF5-positive tumors exhibited locally-increased CD44 expression, suggesting tumor cell differentiation. TM4SF5-positive cells were identified circulating in blood 4 to 6 weeks after orthotopic liver-injection. Anti-TM4SF reagents blocked their metastasis to distal intestinal organs. Altogether, our results provide evidence that TM4SF5 promotes self-renewal and CTC properties supported by $CD133^+/TM4SF5^+/CD44^+^{(TM4SF5-bound)}/ALDH^+/CD24^-$ markers during HCC metastasis.