• Title/Summary/Keyword: TLD

Search Result 362, Processing Time 0.025 seconds

Response of LiF Thermoluminescent Dosimeter to Gamma-Rays as a Cavity Detector (LiF 열형광선량계(熱螢光線量計)의 감마선(線)에 대한 공동검출기(空洞檢出器)로서의 감응(感應))

  • Ha, C.W.;Yook, C.C.;Jun, J.S.
    • Journal of Radiation Protection and Research
    • /
    • v.1 no.1
    • /
    • pp.10-14
    • /
    • 1976
  • Influence of the cavity size on the response of LiF TLD was theoretically investigated for a presumed system of spherical TLD cavity imbedded in a medium of polyethylene. Calculation of the response for different radii of the spherical cavity was carried out as a function of incident photon energy, applying recent cavity theory. The range of the radii covers 1.578 to 6.528 mm, while that of the incident photon energies extends from 0.02 to 3.0 MeV. As a results, the response of the LiF TLD imbedded in a medium as a cavity was found to be functions of its own size as wall as the incident photon energy.

  • PDF

Real-time Face Tracking Method using Improved CamShift (향상된 캠쉬프트를 사용한 실시간 얼굴추적 방법)

  • Lee, Jun-Hwan;Yoo, Jisang
    • Journal of Broadcast Engineering
    • /
    • v.21 no.6
    • /
    • pp.861-877
    • /
    • 2016
  • This paper first discusses the disadvantages of the existing CamShift Algorithm for real time face tracking, and then proposes a new Camshift Algorithm that performs better than the existing algorithm. The existing CamShift Algorithm shows unstable tracking when tracing similar colors in the background of objects. This drawback of the existing CamShift is resolved by using Kinect’s pixel-by-pixel depth information and the Skin Detection algorithm to extract candidate skin regions based on HSV color space. Additionally, even when the tracking object is not found, or when occlusion occurs, the feature point-based matching algorithm makes it robust to occlusion. By applying the improved CamShift algorithm to face tracking, the proposed real-time face tracking algorithm can be applied to various fields. The results from the experiment prove that the proposed algorithm is superior in tracking performance to that of existing TLD tracking algorithm, and offers faster processing speed. Also, while the proposed algorithm has a slower processing speed than CamShift, it overcomes all the existing shortfalls of the existing CamShift.

Measuring Thermo-luminescence Efficiency of TLD-2000 Detectors to Different Energy Photons

  • Xie, Wei-min;Chen, Bao-wei;Han, Yi;Yang, Zhong-Jian
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.179-183
    • /
    • 2016
  • Background: As an important detecting device, TLD is a widely used in the radiation monitoring. It is essential for us to study the property of detecting element. The aim of this study is to calculate the thermo-luminescence efficiency of TL elements. Materials and Methods: A batch of thermo-luminescence elements were irradiated by the filtered X-ray beams of average energies in the range 40-200 kVp, 662 keV $^{137}Cs$ gamma rays and then the amounts of lights were measured by the TL reader. The deposition energies in elements were calculated by theory formula and Monte Carlo simulation. The unit absorbed dose in elements by photons with different energies corresponding to the amounts of lights was calculated, which is called the thermo luminescent efficiency (${\eta}^{(E)}$). Because of the amounts of lights can be calculated by the absorbed dose in elements multiply ${\eta}^{(E)}$, the ${\eta}^{(E)}$ can be calculated by the experimental data (the amounts of lights) divided by absorbed dose. Results and Discussion: The deviation of simulation results compared with theoretical calculation results were less than 5%, so the absorbed dose in elements was calculated by simulation results in here. The change range of ${\eta}^{(E)}$ value, relative to 662 keV $^{137}Cs$ gamma rays, is about 30% in the energy range of 33 keV to 662 keV, is in accordance by the comparison with relevant foreign literatures. Conclusion: The ${\eta}^{(E)}$ values can be used for updating the amounts of lights that are got by the direct ratio assumed relations with deposition energy in TL elements, which can largely reduce the error of calculation results of the amounts of lights. These data can be used for the design of individual dosimeter which used TLD-2000 thermo-luminescence elements, also have a certain reference value for manufacturer to improve the energy-response performance of TL elements by formulation adjustment.

Quality Assurance of CORVUS Planning System for Intensity Modulated Radiation Therapy (CORVUS Planning System을 사용한 세기조절방사선치료의 정도관리에 관한 연구)

  • 김성규
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.9-16
    • /
    • 2004
  • The intensity modulated radiation therapy (IMRT) is believed to be on of the best treatment techniques for the goal of radiation therapy: to irradiate fatal dose to tumor region while minimizing dose to critical organs. It is essential to have comprehensive quality assurance program to assure the precision and the accuracy of the treatment due to the characteristic of the IMRT. The quality assurance technique for the Corvus treatment planning system was developed and its effectiveness was tested with the treatment planning of H&N region. Acrylic phantom, film and ionization chamber were used for this study, the discrepancy between the treatment planning and the film measurements showed 0.03 cm and 0.28 cm for the 90% of isodose line in each directions. Dose measurements showed 1% and 1.2% differences for ionization chamber and TLD, respectively. This concluded that the system can be used for clinic.

  • PDF

Optimization of Process Variables in the Hydrogenation of p-Toluidine on Ru/C Catalyst (Ru/C 촉매를 이용한 p-Toluidine의 선택적 수소화 반응에 있어서 공정변수의 최적화연구)

  • Hong, Bum-eui;Lee, Jong-min;Park, Yeung-ho
    • Applied Chemistry for Engineering
    • /
    • v.19 no.4
    • /
    • pp.432-438
    • /
    • 2008
  • Hydrogenation reactions of p-toluidine over Ru/C were performed while varying reaction temperature, the hydrogen pressure, catalyst loading, solvent, and alkali additive and the effects on the reaction rates and product distribution were examined. 4-Methylcyclohexylamine was generated as a main product and bis(4-methyl cyclohexyl)amine was obtained as a resentative side-product for the hydrogenation reaction of p-toluidine. The selectivity of MCHA decreased with reaction temperature and the hydrogen pressure while increased with catalyst loading. IPA was the best solvent for MCHA. A mechanism of hydrogenation reaction of p-toluidine was suggested from the results. It was found that the presence of alkali salt increased MCHA by reducing BMCHA and rates of hydrogen reaction increased.

Study on the Dosimetry and Assessment of Terrestrial Radiation Exposure (지각 방사선에 의한 피폭선량측정 및 해석)

  • Jun, Jae-Shik;Oh, Hi-Peel;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.2
    • /
    • pp.87-100
    • /
    • 1990
  • For the quantitative evaluation and assessment of radiation exposure from terrestrial component of natural environmental radiation, successive thermoluminescence dosimetry and periodical in-situ gamma ray spectrometry were carried out for a period of 24 months. LiF PTFE dise TLDs and $3&{\phi}{\times}3'$cylindrical NaI(Tl)scintill ation detector in association of portable multichannel analyzer (4096 ch) were used in this study. The doses measured were evaluated and assessed in terms of effective dose equivalent. As a concomitant output, the dose equivalent due to ionizing component of cosmic ray was able to be evaluated. According to the results obtained in terms of variance weighted mean, the annual effective dose equivalents of terrestrial gamma ray and cosmic ray ionizing component in Taejeon area came out to be $564{\pm}4\;{\mu}Sv(64.8{\pm}0.5nSv{\cdot}h^{-1}$ and $300{\pm}2\;{\mu}Sv(34.3{\pm}0.2nSv{\cdot}h^{-1}$, respectively, which are reasonable comparably with that appeared in UNSCEAR Report[28]as per caput annual effective dose equivalent in 'areas of normal background radiation'.

  • PDF

Estimation of the effective dose of dental cone-beam computed tomography using personal computer-based Monte Carlo software

  • Kim, Eun-Kyung;Han, Won-Jeong;Choi, Jin-Woo;Battulga, Bulgan
    • Imaging Science in Dentistry
    • /
    • v.48 no.1
    • /
    • pp.21-30
    • /
    • 2018
  • Purpose: To calculate the effective doses of cone-beam computed tomography (CBCT) using personal computer-based Monte Carlo (PCXMC) software (Radiation and Nuclear Safety Authority, Helsinki, Finland) and to compare the calculated effective doses with those measured using thermoluminescent dosimeters (TLDs) and an anthropomorphic phantom. Materials and Methods: An Alphard VEGA CBCT scanner (Asahi Roentgen Ind. Co., Kyoto, Japan) with multiple fields of view (FOVs) was used for this study. The effective doses of the scout and main projections of CBCT using 1 large and 2 medium FOVs with a height >10 cm were calculated using PCXMC and PCXMCRotation software and then were compared with the doses obtained using TLD-100 LiF and an anthropomorphic adult human male phantom. Furthermore, it was described how to determine the reference points on the Y- and Z-axes in PCXMC, the important dose-determining factors in this software. Results: The effective doses at CBCT for 1 large ($20.0cm{\times}17.9cm$) and 2 medium FOVs ($15.4cm{\times}15.4cm$ and $10.2cm{\times}10.2cm$) calculated by the PCXMC software were 181, 300, and $158{\mu}Sv$, respectively. These values were comparable (16%-18% smaller) to those obtained through TLD measurements in each mode. Conclusion: The use of PCXMC software could be an alternative to the TLD measurement method for effective dose estimation in CBCT with large and medium FOVs.

Intercomparison Exercise at Harshaw 6600, DVG-02TM, and D-Shuttle Dosimeters for the Individual Monitoring of Ionizing Radiation

  • Kim, Dmitriy Spartakovich;Murayama, Kentaro;Nurtazin, Yernat;Koguchi, Yasuhiro;Kenzhin, Yergazy;Kawamura, Hiroshi
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.79-88
    • /
    • 2019
  • Background: The main goal of experiments is to compare various operational and technical characteristics of D-Shuttle semiconductor personal dosimeters of the Japanese company "Chiyoda Technol Corporation" and Harshaw thermoluminescent dosimeters (TLD) manufactured by "Thermo Fisher Scientific" and DTL-02 of the Russian Research and Production Enterprise (RPE) "Doza" by their occupational and calibration exposure at various dose equivalents from 0.5 to 20 mSv of gamma-radiation. Materials and Methods: Besides dosimeters DTL-02, D-Shuttle and Harshaw TLD, there were also used: (1) the primary reference radionuclide source Hopewell Designs IAEA: G10-1-12 with $^{137}Cs$ isotope (an error is not more than 6% and activity is 20 Ci), and (2) the verification device UPGD-2M of RPE "Doza" and installed in the National Center for Expertise and Certification of the Republic of Kazakhstan (Kapchagai, the National Center for Expertise and Certification). Results and Discussion: The main results of researches are the following: (1) TLDs for Harshaw 6600 and DVG-02TM have an approximately equal measurement accuracy of the individual dose equivalents in the range from 0.5 to 20 mSv of gamma-radiation. (2) Advantages of dosimeters for Harshaw 6600 are due to the high measurement productivity and opportunity to indicate the dose on the skin $H_p$(0.07). Advantages of DVG-02TM consist of operation simplicity and lower cost than of Harshaw 6600. (3) D-Shuttles are convenient for use in the current and the operational monitoring of ionizing radiation. Measurement accuracy and 10% linearity of measurements are ensured when D-Shuttle is irradiated with dose equivalents below 1 mSv at the equivalent dose rate not higher than $3mSv{\cdot}hr^{-1}$. This allows using D-Shuttle at a routine technological activity. Conclusion: The obtained results of experiments demonstrate advantages and disadvantages of D-Shuttle semiconductor dosimeters in comparison with two TLD systems of DVG-02TM and Harshaw 6600.

The Usefulness Evaluation of Radiation Shielding Devices in PET Scan Procedures (PET 검사 프러시저별 방사선 차폐기구의 유용성 평가)

  • Kim, Yeong-Seon;Seo, Myeong-Deok;Lee, Wan-Kyu;Jeong, Yo-Cheon;Kim, Sang-Wook;Seo, Il-Teak;Song, Jae-Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.65-76
    • /
    • 2010
  • Purpose: he use of PET scanners and the number of patient in Korea have been increased for recent several years dramatically. For this reason, technologists have more possibilities to be exposed to the radiation. The hospitals using PET scanners should make an effort to reduce the radiation exposure dose. The purpose of this study was to evaluate the radiation exposure does when using radiation shielding devices. The evaluation was performed through questionnaire survey and experiment. Materials and Methods: First, the technologists who had experience working in PET center in 2008-2009 were surveyed with questionnaire and TLD Figures, personal opinion of utilization of radiation shielding devices are analyzed. Second, we measured the shielding rate of shielding devices which have been using in PET study procedures. We divided the procedures into four steps; distribution, moving, injection of $^{18}F$-FDG and patient setup. Results: First, the results of this survey, using of L-block+Syringe shield, L-block, Syringe shield, No shield during the injection, were each 58.5%, 20%, 9%, 12.3%. The TLD values according to utilization of radiation shield, using both L-block+Syringe Shield and L-block showed the lower TLD values, and Syringe shield only or No shield showed the higher TLD values. Second, the results of experiments according to PET study procedures measured the shielding rates as follows. The shielding rates during the distribution using L-block, L-block+Apron shield were measured 97.4%, 97.7%. The shielding rates during the $^{18}F$-FDG delivery to the injection room using mobile Syringe shield, Syringe holder, Syringe shield carrier were each 81.7%, 98.9%, 99.7%. The shielding rates during the injection using Syringe shield, L-block, L-block+Syringe shield were measured each 51.9%, 98.3%, 98.7%. The shielding rates of Apron were measured in each 30, 60, 90, 120, 150 cm distance. The measurement were each 16.9%, 14.2%, 16.6%, 17.1%, 18.1%, 18.6%. Conclusion: The most effective method for radiation shielding is to using L-block during the $^{18}F$-FDG distribution and Syringe shield carrier during in moving $^{18}F$-FDG. For the $^{18}F$-FDG injection, L-block+Syringe shield have to be used. The shielding effect of Apron has shown average 16.4%. According to the survey of questionnaire, the operators recognized well risk of the radiation exposure but, tended ignore in working. The radiation dose according to recognition of radiation exposure risk was not relevant. but radiation dose according to utilization of radiation shield lower the more use it. The main reason of no use of shielding devices is cumbersome, 55% of the respondents answered. I'm sure, by use of radiation shield in all PET procedure, radiation exposure will be reduced considerably.

  • PDF