• Title/Summary/Keyword: TL Analysis

Search Result 287, Processing Time 0.023 seconds

Development of Chemical Separation Process for Thallium-201 Radioisotope with Lead Standard Material (납 표준물질을 이용한 방사성동위원소 Thallium-201의 화학적 분리공정 개발)

  • JunYoung Lee;TaeHyun Kim;JeongHoon Park
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.543-549
    • /
    • 2023
  • Thallium-201 (201Tl) is a medical radioisotope which emits gamma rays when it decays and used in myocardial perfusion scans in single-photon emission tomography due to its similar properties to potassium. Currently, the Korea Institute of Radiological & Medical Sciences is the only institution producing 201Tl in Korea, and optimization of 201Tl production research is necessary to meet supply compared to domestic demand. To this end, technical analysis of plating target production and chemical separation methods essential for 201Tl production research is conducted. It deals with the process of generating and separating 201Tl radioisotope and target production, It can be generated through a nuclear reaction such as natHg(p,xn)201Tl, 201Hg(p,n)201Tl, natPb(p,xn)201Bi → 201Pb → 201Tl, 205Tl(p,5n)201Pb → 201Tl, and considering impure nuclide generated simultaneously with the use of proton beam energy of 35 MeV or less, it is intended to be produced using the 203Tl(p,3n)201Pb→201Tl nuclear reaction. In particular, the chemical separation of Tl is a very important element, and the chemical separation methods that can separate it is broadly divided into four types, including solid phase extraction, liquid-liquid, electrochemical, and ion exchange membrane separation. Some chemical separations require additional separation steps, such as methods using selective adsorption. Therefore, this technical report describes four chemical separation methods and seeks to separate high-purity 201Tl using a method without additional separation steps

Global Transcriptional Analysis Reveals Upregulation of NF-${\kappa}B$-responsive and Interferon-stimulated Genes in Monocytes by Treponema lecithinolyticum Major Surface Protein

  • Lee, Sung-Hoon;Lee, Hae-Ri;Jun, Hye-Kyoung;Choi, Bong-Kyu
    • International Journal of Oral Biology
    • /
    • v.36 no.2
    • /
    • pp.91-101
    • /
    • 2011
  • MspTL is the major surface protein of Treponema lecithinolyticum associated with periodontitis and endodontic infections. Our recent investigation revealed that MspTL induces proinflammatory cytokines and intercellular adhesion molecule 1 in THP-1 cells and periodontal ligament cells. In this study we conducted oligonucleotide microarray analysis to investigate the global transcriptional regulation in THP-1 cells stimulated with purified recombinant MspTL. MspTL upregulated the expression of 90 genes in THP-1 cells at least four fold, and the functions of these genes were categorized into adhesion, apoptosis/antiapoptosis, cell cycle/growth/differentiation, chemotaxis, cytoskeleton organization, immune response, molecular metabolism, proteolysis, signaling, and transcription. The majority of the modified genes are known to be NF-${\kappa}B$-responsive and interferon-stimulated genes (ISGs). The expression of 12 selected genes was confirmed by real-time RT-PCR. Because prostaglandin $E_2(PGE_2)$ is an important inflammatory mediator and Cox-2 was found to be induced by MspTL in the microarray analysis, we determined the level of $PGE_2$ in the culture supernatants of MspTL-treated cells and found that MspTL significantly increased $PGE_2$. Our results provide insight into the gene regulation of host cells in response to MspTL, and may contribute to the understanding of the molecular mechanism in periodontitis.

Application of Thermoluminescence to Detecting Post-Irradiation of Onion and Garlic (열발광기를 이용한 양파와 마늘의 방사선 조사 여부 검지)

  • ;;Ute Wagner;Georg A. Schreiber
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.27 no.1
    • /
    • pp.63-68
    • /
    • 1998
  • Irradiation can be utilized to inhibit sprouting of onions and garlic. Thermoluminescence(TL) is a potential method to detect post-irradiation of onions and garlic because they are irradiated with soil or dusts on them, from which minerals can be isolated for TL analysis. This study was to determine whether TL can be applied for the detection of post-irradiation of onions and garlic. Onions and garlic produced in Korea were irradiated in the range of 0.01~0.6kGy. Minerals isolated from the samples using sodium polytrungstate solution were used for TL analysis. The onions and garlic irradiated at 0.15kGy or higher could be detected with little errors. Minimum dose for the 2nd glow could be applied since the dose for the 2nd glow did not affect the results. The TL intensities of the temperature ranges of 229~295$^{\circ}C$ and 229~361$^{\circ}C$ and the maximum intensity provided more accurate information for the determination of the post-irradiation of onions and garlic.

  • PDF

Left Ventricular Ejection Fraction Determined by Gated Tl-201 Perfusion SPECT and Quantitative Software (게이트 Tl-201 관류 SPECT와 Cedars 소프트웨어를 이용하여 측정한 좌심실 구혈률)

  • Hyun, In-Young;Kim, Sung-Eun;Seo, Jeong-Kee;Hong, Eui-Soo;Kwan, Jun;Park, Keum-Soo;Lee, Woo-Hyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.222-227
    • /
    • 2000
  • Purpose: We compared estimates of ejection fraction (EF) determined by gated Tl-201 perfusion SPECT (g-Tl-SPECT) with those by gated blood pool (GBP) scan. Materials and Methods: Eighteen subjects underwent g-Tl-SPECT and GBP scan. After reconstruction of g-Tl-SPECT, we measured EF with Cedars software. The comparison of the EF with g-Tl-SPECT and GBP scan was assessed by correlation analysis and Bland Altman plot. Results: The estimates of EF were significantly different (p<0.05) with g-Tl-SPECT ($40%{\pm}14%$) and GBP scan ($43%{\pm}14%$). There was an excellent correlation of EF between g-Tl-SPECT and GBP scan (r=0.94, p<0.001). The mean difference of EF between GBP scan and g-Tl-SPECT was +3.2% Ninety-five percent limits of agreement were ${\pm}9.8%$. EF between g-Tl-SPECT and GBP scan were in poor agreement. Conclusion: The estimates of EF by g-Tl-SPECT was well correlated with those by GBP scan. However, EF of g-Tl-SPECT doesn't agree with EF of GBP scan. EF of g-Tl-SPECT can't be used interchangeably with EF of GBP scan.

  • PDF

Detection Characteristics of TL, ESR and DNA Comet for Irradiated Peanuts by Origins (TL, ESR및 DNA Comet분석에 의한 원산지별 땅콩의 방사선 조사 검지 특성)

  • 이은영;정재영;조덕조;권중호
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.6
    • /
    • pp.1076-1081
    • /
    • 2001
  • Gamma-irradiated peanuts, Korean and Chinese origins, were investigated on detection properties by thermoluminescence (TL), electron spin resonance (ESR), and DNA comet assay (single cell gel electrophoresis). TL measurement showed that the non-irradiated sample revealed a glow curve with low intensity at about 25$0^{\circ}C$, while the irradiated samples showed higher intensity around at 18$0^{\circ}C$. TL ratio (TL$_1$/TL$_2$) of area for TL$_1$ glow curve to TL$_2$ was below 0.05 for the non-irradiated sample and 0.2 or more for the irradiated ones, thus identifying each other. ESR spectroscopy for the irradiated peanuts using outer skin showed negligible signals induced by irradiation, indicating ESR is little applicable to the detection of irradiated peanuts. In DNA comet assay, the non-sample had no or very short tails, whereas the irradiated samples revealed the cells with long tails. Significance in the increase of their lengths depending on irradiation dose (r=0.761/Korean, r=0.768/Chinese) was also found. There was no remarkable difference in detection properties by origins of samples in all determinations, It is concluded that TL analysis or DNA comet assay is suitable for detection of irradiated peanuts and a combined method is recommendable for enhancing the reliability of detection results.

  • PDF

Evaluation of TlBr semiconductor detector in gamma camera imaging: Monte Carlo simulation study

  • Youngjin Lee;Chanrok Park
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4652-4659
    • /
    • 2022
  • Among the detector materials available at room temperature, thallium bromide (TlBr), which has a relatively high atomic number and density, is widely used for gamma camera imaging. This study aimed to verify the usefulness of TlBr through quantitative evaluation by modeling detectors of various compound types using Monte Carlo simulations. The Geant4 application for tomographic emission was used for simulation, and detectors based on cadmium zinc telluride and cadmium telluride materials were selected as a comparison group. A pixel-matched parallel-hole collimator with proven excellent performance was modeled, and phantoms used for quality control in nuclear medicine were used. The signal-to-noise ratio (SNR), contrast to noise ratio (CNR), sensitivity, and full width at half maximum (FWHM) were used for quantitative analysis to evaluate the image quality. The SNR, CNR, sensitivity, and FWHM for the TlBr detector material were approximately 1.05, 1.04, 1.41, and 1.02 times, respectively, higher than those of the other detector materials. The SNR, CNR and sensitivity increased with increasing detector thickness, but the spatial resolution in terms of FWHM decreased. Thus, we demonstrated the feasibility and possibility of using the TlBr detector material in comparison with commercial detector materials.

The Measurement and Analysis of LiF:Mg, Cu, Na, Si TL Material by Thermoluminescence Spectrum (LiF:Mg, Cu, Na, Si TL 물질의 열자극발광스펙트럼 측정 및 분석)

  • Lee, J.I.;Moon, J.H.;Kim, D.H.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.149-153
    • /
    • 2001
  • Three-dimensional thermoluminescence(TL) spectra of LiF: Mg, Cu, Na, Si TL material based on temperature, wavelength and intensity were measured and analyzed. The glow curves were obtained by integration of luminescence intensity for wavelength at each temperature, and various trapping parameters related to the trap formation were determined by analyzing these curves. Computerized glow curve deconvolution(CGCD) method which based on general order kinetics(GOK) model were used for the glow curve analysis. The glow curves of LiF:Mg, Cu, Na, Si TL material were deconvoluted to six isolated glow curves which have peak temperature at 333 K, 374 K, 426 K, 466 K, 483 K and 516 K, respectively. The 466 K main glow peak had an activation energy of 2.06 eV and a kinetic order of 1.05. This TL material was also found to have three recombination centers, 1.80 eV, 2.88 eV and 3.27 eV by TL spectra analysis based on Franck-Condon model. It showed that 2.88 eV is the dominant center, followed by 3.27 eV level, and 1.80 eV center is ascertained as emission center of this material even though its very weak emission intensity.

  • PDF

Synthesis and Characterization of Thallium (Ⅲ) Complexes with Tetracyanoquinodimethane, TI$(TCNQ)_3$ and $TICI_2(TCNQ)_{2.5}$

  • 김미경;김영인;문성배;최성낙
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.5
    • /
    • pp.424-428
    • /
    • 1996
  • TlCl2(TCNQ)2.5 and Tl(TCNQ)3 were obtained from the reaction of LiTCNQ (TCNQ=tetracyanoquinodimethane) and TlX3 (X=Cl and NO3). These compounds were characterized by spectroscopic(IR, UV, EPR), electrochemical methods, and electrical conductivity measurements. Thermal analysis (TG, DSC) was also conducted. The room temperature electrical conductivities of these compounds are in the range of semiconductors. Spectroscopic studies indicate that Tl(TCNQ)3 has fully ionized TCNQ- ions in a form of simple salt, whereas TlCl2(TCNQ)2.5 is consisted of TCNQ- and TCNQ0 as a complex salt. EPR values of TCNQ- radical anion are 1.999 in both compounds and the signal attributable to metal ion is not observed, suggesting that any unpaired electrons are localized on TCNQ radicals, and metal atoms have diamagnetic state. Ligand decomposition and reduction process are simultaneously progressed in both compounds above at 200 ℃. The endothermic activation energy of TlCl2(TCNQ)2.5 is shown somewhat larger than that of Tl(TCNQ)3, it may be due to Tl-Cl bond strength. The mid-peak potentials of these compounds are very similar to those of TCNQ and the values of Epa and Epc are almost equal to 1. The wave of thallium ion is not detected in cyclic voltammogram, hence the redox processes of the complexes might be mainly localized to the TCNQ ligand rather than thallium ion.

Physical Detection Properties of Irradiated Wheat and Corn Treated with Different Radiation Sources (방사선 조사선원에 따른 밀과 옥수수의 물리적 검지 특성)

  • Kim, Gui-Ran;Lee, Ju-Woon;Kim, Jeong-Sook;Kwon, Joong-Ho
    • Food Science and Preservation
    • /
    • v.16 no.2
    • /
    • pp.211-216
    • /
    • 2009
  • This study determined the photostimulated luminescence(PSL), thermoluminescence(TL), and electron spin resonance(ESR) properties of wheat and corn irradiated with 0-10 kGy of gamma-ray or electron-beam. PSL values of both irradiated grains, regardless of radiation source, were 241-429 photons/sec in nonirradiated samples(negative values, defined as ${\leq}700$ photons/60 sec) and 5,528-40,870 photons/60 sec in irradiated ones(positive values, defined as ${\geq}5,000$ photons/sec), thereby distinguishing irradiated from nonirradiated samples. The TL glow curves($TL_1$) peaked at around $300^{\circ}C$ in nonirradiated samples, but at about $180^{\circ}C$ in irradiated samples, at high intensities, regardless of radiation source. The TL ratios($TL_1/TL_2$) calculated to strengthen $TL_1$ data reliability were less than 0.03 for nonirradiated samples and over 0.20 for irradiated materials, in good agreement with threshold values for nonirradiated(${\leq}0.1$) and irradiated(${\geq}0.1$) samples. ESR analysis was not applicable in identification of irradiated wheat and corn. Electron-beam irradiation resulted in higher PSL and TL signals than did gamma-rays, at the same applied doses.

Analyzing a Physical Marker to Identify Irradiated Dried Garlic and Cabbage (건마늘과 건양배추의 방사선 조사여부 확인을 위한 물리적 마커 분석)

  • Kim, Dong-Gil;Ahn, Jae-Jun;Jin, Qiong-Wen;Lee, Ho-Cheon;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.2
    • /
    • pp.136-140
    • /
    • 2009
  • The verification of irradiation treatments, using dried garlic and cabbage treated at 0-20 kGy, was investigated by analyzing the photostimulated luminescence (PSL), electron spin resonance (ESR) and thermoluminescence (TL) characteristics of the samples. The PSL results showed that the photon counts/60 sec of the non-irradiated dried garlic and cabbage were 287-337, corresponding to negative, while those of the irradiated samples were 7511-54063 photon counts/ 60 sec, corresponding to positive, making it possible to discriminate the non-irradiated from the irradiated samples. In ESR analysis, the dried garlic irradiated at 20 kGy exhibited cellulose radicals, whereas the irradiated dried cabbage showed crystalline sugar-induced multi-component signals, which were not found in the non-irradiated samples. The ESR signal intensity significantly increased as the irradiation dose increase ($R^2$= 0.9369 - 0.9926). The TL glow curves of the irradiated samples appeared at a temperature interval of 150-250, which were significantly different from those of non-irradiated samples, showing a significant increase in TL signal intensity with irradiation dose ($R^2$= 0.9670 - 0.9768). To enhance the reliability of the results, the first glow curve ($TL_1$) was compared with the second glow curve ($TL_2$) obtained after a re-irradiation step at 1 kGy. The TL ratio ($TL_1/TL_2$) was in good agreement with the reported TL threshold values for both the non-irradiated (<0.1) and irradiated (> 0.1) samples.