• Title/Summary/Keyword: TL

Search Result 1,453, Processing Time 0.03 seconds

Age and Growth of Barbel Steed Hemibarbus labeo in Goe-san Lake in Korea

  • Lee, Wan-Ok;Zhang, Ming-Ming;Oh, Chul-Woong;Baek, Jae-Min;Song, Kyung-Jun
    • Fisheries and Aquatic Sciences
    • /
    • v.15 no.4
    • /
    • pp.353-359
    • /
    • 2012
  • Age and growth of Hemibarbus labeo caught from Goe-san Lake in South Korea from March to November, 2011, were studied. A total of 201 specimens was collected, ranging from 110 to 580 mm in total length (TL). Males and females made up 47.9% and 52.1% of the sample, respectively. Marginal increment analyses showed that vertebral increments, each composed of one opaque and one hyaline zone, were deposited annually. Opaque edges were prevalent from June to July. The relationship between TL and vertebral radius was linear, with equations of R = 0.008TL - 0.208 (male) and R = 0.009TL - 0.272 (female). Regression equations between TL and total weight (TW) were $TW=9{\times}10^{-6}TL^{2.987}$ (male), $TW=8{\times}10^{-6}TL^{3.014}$ (female), and $TW=9{\times}10^{-6}TL^{2.988}$ (combined sexes), according to the von Bertalanffy growth equation. Back-calculated TL was expressed using the von Bertalanffy equation as follows: $L_t=438.25(1-e^{-0.175(t+0.164)})$ for males, $L_t=483.36(1-e^{-0.147(t+0.115)})$ for females, and $L_t=464.86(1-e^{-0.162(t+0.176)})$ for the sexes combined. The growth performances were 4.526, 4.536, and 4.544, respectively.

How Computed Tomography Contrast Media and Magnetic Resonance Imaging Contrast Media Affect the Changes of Uptake Counts of 201Tl

  • Lee, Jin-Hyeok;Lee, Hae-Kag;Cho, Jae-Hwan;Cheon, Miju
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.372-377
    • /
    • 2014
  • The purpose of the study is to investigate how uptake counts of $^{201}Tl$ of radioisotopes in the human body could change, when taking computed tomography and magnetic resonance imaging right after injecting contrast media. $^{201}Tl$ radioisotope substances of iodine contrast medium, which is a computed tomography contrast medium, and paramagnetic contrast medium, which is an magnetic resonance imaging contrast medium, were used as study materials. First, $^{201}Tl$ was put into 4 cc of normal saline in test tube, and then a computed tomography contrast medium of Iopamidol$^{(R)}$ or Dotarem$^{(R)}$, was put into 2 cc of normal saline in test tube. An magnetic resonance imaging contrast medium of Primovist$^{(R)}$ or Gadovist$^{(R)}$ was also put into 2 cc of normal saline in test tube. Each contrast medium was distributed to make $^{201}Tl$ as 3 mCi, with a total of 4 cc. Gamma camera, low energy high resolution collimator, and pinhole collimator were used to obtain images. The uptake count of $^{201}Tl$ was measured with 1000 frames of images, and obtained after 10 times of repetition. This study revealed that the use of Gadovist$^{(R)}$, which is an magnetic resonance imaging contrast medium, showed the smallest number of uptake count, after measuring $^{201}Tl$ uptake count by low energy high resolution collimator. On the other hand, the use of Iopamidol$^{(R)}$, which is a computed tomography contrast medium, showed the biggest difference in uptake count, when measuring $^{99m}Tc$ uptake count by Pinhole collimator. When examining with gamma camera, using contrast medium and $^{201}Tl$, identifying the changes of uptake count is very important for improving the value of diagnosis.

Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Tl-201 Perfusion Single Photon Emission Tomography (심전도 게이트 심근관류 Tl-201 SPECT로 측정된 좌심실 기능 및 좌심실 용적의 정확성)

  • Pai, Moon-Sun;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.94-99
    • /
    • 2005
  • Electrocardiogram-gated single photon omission computed tomography (SPECT) provides valuable information in the assessment of both myocardial perfusion and ventricular function. Tl-201 is a suboptimal isotope for gating. Tl-201 images are more blurred compared with Tc-99m tracers due to the increased amount of scattered photons and use of a smooth filter. The average myocardial count densities are approximately one-half those of conventional technetium tracers. However, Tl-201 is still widely used because of its well-established utility for assessing myocardial perfusion, viability and risk stratification. Gated SPECT with Tl-201 enables us to assess both post-stress and rest left ventricular volume and function. Previous studies with gated Tl-201 SPECT measurements of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) have shown high correlation with first-pass radionuclide angiography, gated blood pool scan, Tc-99m-MIBI gated SPECT, contrast ventriculography, echocardiography, and 3-dimensional magnetic resonance imaging. However, problems related to these studies include few agreement data of EDV and ESV, use of a reference method that is likely to have the same systemic errors (gated Tc-99m-MIBI SPECT), and other technical factors related to the count density of gated SPECT. With optimization of gated imaging protocols and more validation studies, gated Tl-201 SPECT would be an accurate method to provide perfusion and function information in patients with coronary artery disease.

Growth of Ammodytes personatus in Korean waters 1, Daily Growth Increment, Early Growth and Spawning Time in Juvenile Stage (까나리, Ammodytes personatus의 성장 1. 치어의 일령, 초기성장 및 산란시기)

  • KIM Yeong Hye;KANG Yong Joo;RYU Dong Ki
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.5
    • /
    • pp.550-555
    • /
    • 1999
  • The growth and spawning time of juvenile Ammodytes personatus were analyzed based on the daily growth increment in otolith reading of the sample caught in the coastal waters of Shinsudo, Sacheon from March 20 to May 1, 1988. Daily growth increment in otolith was formed once a day. The estimated spawning time ranged from November, 1987 to March, 1988. The von Bertalanffy growth model and the Gompertz growth model were expressed as, $TL=87.80(1-e^{-0.0074(t+10.79)})$ and $TL=72.59 e^{-1.8417\;e-0.0152t}$ respectively, where TL is total length in mm, t is age in day.

  • PDF

Thermoluminescence (TL) of Minerals Separated from Irradiated Mussel

  • Yi, Sang-Duk;Oh, Man-Jin
    • Preventive Nutrition and Food Science
    • /
    • v.10 no.1
    • /
    • pp.17-21
    • /
    • 2005
  • This study was carried out to determine whether detection of minerals separated from irradiated mussel could be could be done by thermoluminescence (TL) method. After the minerals were separated by sodium polytungstate solution (2.0 g/mL) from irradiated mussel, organic compounds remaining in the minerals were removed by acid-base treatment and dried at 50℃ overnight, and then the minerals were measured through TL. The TL intensities of separated minerals at different irradiation doses during storage conditions of room and darkroom were obtained. TL intensity of first glow curves for minerals separated from irradiated mussel showed linear increase from the control to 5 kGy and slight increase from 5 kGy to 10 kGy. Since glow curve ratios of G2, G3 and G4, calculated from re-irradiated minerals measured immediately after irradiation and after storage of three months were over 0.5, detection of irradiation was possible. G1, which showed the glow curve ratios above 0.1, was classified as non-irradiated samples because the unique first glow curve was not found within the recommended temperature interval (150-230℃). Hence, on the basis of TL intensity, and glow curve ratio and shape, it is possible to correctly identify irradaited mussels after mineral separation during storage.

Magnetic properties of polycrystalline Tl-1223 superconductor (Tl-1223 다결정 초전도체의 자기적 특성)

  • Baek R;Lee J. H;Kim Y. C;Jeong D. Y
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.41-45
    • /
    • 2004
  • Polycrystalline Tl-1223 superconductors with a chemical composition of (Tl, Pb, Bi)TEX>$ (Sr, Ba)<_2$$Ca_2$$Cu_3$$O_{x}$ were synthesized by the solid state reaction method. The optimum chemical composition was $Tl_{0.8}$ $Pb_{0.2}$ $Bi_{0.2}$ $Sr_{1.8}$ $Ba_{0.2}$ $Ca_{2.2}$ $Cu_3$$O_{x}$ And the optimum sintering temperature and time were $905^{\circ}C$ and 7.5h, respectively. The sample was evaluated for their superconducting properties by magnetization measurement. The critical temperature $T_{c}$ is 120 K and the critical current density $J_{c}$ (T=5K, 0T) is estimated to be ∼ $10^{5}$ A/$\textrm{cm}^2$ for $Tl_{0.8}$ $Pb_{0.2}$ $Bi_{0.2}$ $Sr_{1.8}$ $Ba_{0.2}$ $Ca_{2.2}$$Cu_3$$O_{x}$ .

  • PDF

Properties of PSL, TL, and ESR to Identify the Irradiated Sesame Seeds after Steaming

  • Lee, Jeon-Geun;Kausar, Tusneem;Chung, Hyung-Wook;Jeong, Il-Yun;Bhatti, Ijaz A.;Kwon, Joong-Ho
    • Food Science and Biotechnology
    • /
    • v.18 no.2
    • /
    • pp.374-378
    • /
    • 2009
  • Three physical methods, photostimulated luminescence (PSL), thermoluminescence (TL), and electron spin resonance (ESR), have been applied to detect the irradiation treatment for the non- and steamed sesame seed samples. PSL successfully screened the irradiated samples from the non-irradiated control by comparing their photon counts (PCs) with the lower (less than 700 count/60 sec) and upper threshold values (higher than 5,000 count/60 sec). TL signals were still detected in all irradiated samples even after steaming, which was reconfirmed with TL ratios [integrated area of $TL_1$ (the first glow)/$TL_2$ (the second glow)] through re-irradiation step. ESR spectrometry showed that radiation-induced cellulose radicals were detected in all the irradiated samples irrespective of steaming treatment. Identification of the irradiated sesame seeds was possible even after steaming by analyzing PSL, TL, and ESR.

Thermoluminescent Characteristics of Newly Developed LiF:Mg,Cu,Na,Si TL Detectors

  • Lee J. I.;Kim J. L.;Chang S. Y.
    • Nuclear Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.47-52
    • /
    • 2004
  • Recently, a new sintered pellet-type LiF:Mg,Cu,Na,Si TL detector which has a high sensitivity and good reusability, named KLT-300(KAERI LiF:Mg,Cu,Na,Si TL detector), was developed by the variation of the dopants concentrations and the parameters of the preparation procedure at KAERI (Korea Atomic Energy Research Institute). In this study, the thermoluminescent characteristics of the newly developed TL detectors were investigated. The sensitivity of the TL detector was compared with that of the TLD-100 by light integration. The dose linearity of the detector was tested from $10^{-6}$ Gy up to 30 Gy. The dose response was very linear up to 10 Gy and a sublinear response was observed at higher doses. The energy response of the detector was studied for photon energies from 20 keV to 662 keV. The result shows that a maximum response of 1.004 at 53 keV and a minimum response of 0.825 at 20 keV were observed. The reproducibility study for the TL detector was also carried out. The coefficients of variation for each detector separately did not exceed 0.016, and for all the 10 detectors collectively was 0.0054. Lower limit of detection for the detector was investigated at 70 nGy by the Harshaw 4500 TLD Reader and the residual signal of the TL detector was found to be $0.57\%$.

Identification of Irradiated Granule-Type Ramen Soup Powder by Pulsed Photostimulated Luminescence and Thermoluminescence during Storage

  • Yi, Sang-Duk;Yang, Jae-Seung;Kim, Dong-Woo;Shin, Doo-Ho;Jo, Gab-Yeon;Chang, Kyu-Seob;Oh, Man-Jin
    • Preventive Nutrition and Food Science
    • /
    • v.8 no.1
    • /
    • pp.79-84
    • /
    • 2003
  • This study was carried out to establish a method for determining if granule-type Ramen soup powder has been irradiated. Thermoluminescence (TL) and pulled photostimulated luminescence (PPSL) were used as the detection methods through observed changes of TL and PPSL intensities after storage under differing conditions. PPSL intensities increased with increases in irradiation doses. The threshold level of PPSL was below 412$\pm$58 photon counts regardless of storage conditions (room and darkroom) after 10 months. TL intensities also increased with increasing irradiation doses. The coefficients ($R^2$) of PPSL (0.74~0.94) and TL intensities (0.92~0.58) were very highly correlated with irradiation dose. The PPSL and TL intensities were decreased after 10 months of storage. These results indicate that discrimination of irradiated from non-irradiated granule-type Ramen soup powder is possible using TL and PPSL methods despite the decrease in intensities of TL and PPSL with increasing storage times.

Archival Data Stability Evaluation and Aspect of BD-R TL Media (BD-R TL 매체의 장기 안정성 평가 및 보존 특성 향상에 관한 고찰)

  • Park, Sun-Joo;Kim, Do-Hyun;Lee, Kwan-Yong;Lee, Jae-Yong;Kim, Young Il;Bahng, Keuk-Young;Kim, Young-Joo
    • Transactions of the Society of Information Storage Systems
    • /
    • v.11 no.2
    • /
    • pp.31-35
    • /
    • 2015
  • The Blu-ray Disc Recordable-Triple Layer (BD-R TL) media is considered as one of strong candidates for archival application among optical media formats, due to its large capacity. However, the long-term stability and degradation aspect have not been fully understood yet for BD-R TL media. Thus, the BD-R TL media were recorded at full tracks and analyzed by the random-symbol error rate (R-SER) measurement at different recording layers and recording positions after the accelerated aging test to understand its long-term stability. Finally, the general degradation aspect of BD-R TL media was discussed to improve the long-term stability.