• Title/Summary/Keyword: TL

Search Result 1,459, Processing Time 0.022 seconds

A TiO2-Coated Reflective Layer Enhances the Sensitivity of a CsI:Tl Scintillator for X-ray Imaging Sensors

  • Kim, Youngju;Kim, Byoungwook;Kwon, Youngman;Kim, Jongyul;Kim, MyungSoo;Cho, Gyuseong;Jun, Hong Young;Thap, Tharoeun;Lee, Jinseok;Yoon, Kwon-Ha
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.256-260
    • /
    • 2014
  • Columnar-structured cesium iodide (CsI) scintillators doped with thallium (Tl) are frequently used as x-ray converters in medical and industrial imaging. In this study we investigated the imaging characteristics of CsI:Tl films with various reflective layers-aluminum (Al), chromium (Cr), and titanium dioxide ($TiO_2$) powder-coated on glass substrates. We used two effusion-cell sources in a thermal evaporator system to fabricate CsI:Tl films on substrates. The scintillators were observed via scanning electron microscopy (SEM), and scintillation characteristics were evaluated on the basis of the emission spectrum, light output, light response to x-ray dose, modulation transfer function (MTF), and x-ray images. Compared to control films without a reflective layer, CsI:Tl films with reflective layers showed better sensitivity and light collection efficiency, and the film with a $TiO_2$ reflective layer showed the best properties.

An Integrated System for Radioluminescence, Thermoluminescence and Optically Stimulated Luminescence Measurements

  • Park, Chang-Young;Park, Young-Kook;Chung, Ki-Soo;Lee, Jong-Duk;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.160-169
    • /
    • 2018
  • Background: This study aims to develop an integrated optical system that can simultaneously or selectively measure the signals obtained from radioluminescence (RL), thermoluminescence (TL), and optically stimulated luminescence (OSL), which are luminescence phenomena of materials stimulated by radioactivity, heat, and light, respectively. The luminescence mechanism of various materials could be investigated using the glow curves of the luminescence materials. Materials and Methods: RL/TL/OSL integrated measuring system was equipped with a X-ray tube (50 kV, $200{\mu}A$) as an ionizing radiation source to irradiate the sample. The sample substrate was used as a heating source and was also designed to optically stimulate the sample material using various light sources, such as high luminous blue light emitting diode (LED) or laser. The system measured the luminescence intensity versus the amount of irradiation/stimulation on the sample for the purpose of measuring RL, TL and OSL sequentially or by selectively combining them. Optical filters were combined to minimize the interference of the stimulation light in the OSL signal. A long-pass filter (420 nm) was used for 470 nm LED, an ultraviolet-pass filter (260-390 nm) was used for detecting the luminescence of the sample by PM tube. Results and Discussion: The reliability of the system was evaluated using the RL/OSL characteristics of $Al_2O_3:C$ and the RL/TL characteristics of LiF:Mg,Cu,Si, which were used as dosimetry materials. The RL/OSL characteristics of $Al_2O_3:C$ showed relatively linear dose-response characteristics. The glow curve of LiF:Mg,Cu,Si also showed typical RL/OSL characteristics. Conclusion: The reliability of the proposed system was verified by sequentially measuring the RL characteristics of radiation as well as the TL and OSL characteristics by concurrent thermal and optical stimulations. In this study, we developed an integrated measurement system that measures the glow curves of RL/TL/OSL using universal USB-DAQs and the control program.

Comparison of Irradiated Food with Electron Beam and Gamma-ray by PSL and TL Methods (광자극발광법과 열발광법 분석을 통한 전자선과 감마선 조사식품의 비교 연구)

  • Kim, Kyu-Heon;Kwak, Ji-Young;Yoon, Jin-Ho;Park, Young-Eun;Lee, Jae-Hwang;Park, Yong-Chjun;Jo, Tae-Yong;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.3
    • /
    • pp.258-266
    • /
    • 2013
  • This study was conducted to determine the PSL and TL properties of foods irradiated with electron beam and gamma-ray. 5 kinds of food including cereal, pulse, fish powder, dried vegetable and tea were irradiated at 0 to 10 kGy by electron beam accelerator or $^{60}Co$ gamma-ray irradiator. The PSL analysis showed negative results for most of the non-irradiated samples. Non-irradiated shrimp powder showed intermediate result. Irradiated samples gave negative or intermediate or positive value which presented the limitation of PSL technique. In TL analysis, there were TL glow curves at around $300^{\circ}C$ with low intensity on non-irradiated samples. Maximum peak in the range of $150-250^{\circ}C$ was appeared on irradiated samples. TL ratio obtained by re-irradiation with 1 kGy was less than 0.1 on non-irradiated samples and higher than 0.1 on irradiated samples. Therefore, in PSL measurement, electron-beam irradiated samples could obtain more clear results. TL analysis showed obvious difference between non-irradiated and irradiated samples. But the identification was impossible for the sample of rice and lemon tea. Because of it's low contents of mineral.

Detection Characteristics of PSL and TL Methods in Spices Irradiated with Different Radiation Sources (조사선원에 따른 향신료의 PSL과 TL 검지 특성)

  • Kim, Kyu-Heon;Kwak, Ji-Young;Kim, Jung-Ki;Hwang, Cho-Rong;Lee, Jae-Hwang;Park, Yong-Chjun;Kim, Jae-I;Jo, Tae-Yong;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Radiation Industry
    • /
    • v.7 no.1
    • /
    • pp.15-21
    • /
    • 2013
  • The detection characteristics of irradiated spices were investigated depending on radiation sources and doses by photostimulated luminescence (PSL) and Thermoluminescence (TL). 6 kinds of spices (turmeric, onion powder, red pepper, basil, parsley, black pepper) were irradiated at 0 to 10 kGy under ambient conditions by both a $^{60}Co$ gamma irradiator and an electron beam (EB) accelerator, respectively. The PSL analysis showed negative results for non-irradiated spices, while irradiated spices gave intermediate and positive value, which presented the limited potential of PSL technique. In TL measurement, TL glow curves on non-irradiated samples appeared at about $300^{\circ}C$ with low intensity. All irradiated samples were easily distinguishable through radiation-specific strong TL glow curves with maximum peak in range of $150{\sim}200^{\circ}C$. TL ratio ($TL_1/TL_2$) obtained by a re-irradiation step could verify the detection result of $TL_1$ glow curves, showing ratios lower than 0.1 in the non-irradiated sample and higher than 0.1 in irradiated ones. Therefore, in PSL measurement, the identification of irradiated spices showed more clear results in electron beam irradiated samples. TL analysis showed obvious difference between non-irradiated and irradiated samples in gamma ray and electron beam irradiated samples.

Thallium-201 Scan in Bone and Softtissue Sarcoma - Comparison with Tc-99m-MIBI and Tc-99m-MDP Scan - (악성 골 및 연부조직 종양에서 Tl-201 SCAN의 진단적 효능 - Tc-99m-MIBI 및 Tc-99m-MDP scan과의 비교 -)

  • Shin, Duk-Seop;Cho, Ihn-Ho;Ahn, Jong-Chul;Ahn, Myun-Hwan;Lee, Sang-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.2 no.1
    • /
    • pp.1-7
    • /
    • 1996
  • PURPOSE : The purpose of this study is to know the ability of detecting malignant tumor tissue by Tl-201 scan, and to compare with that of Tc-99m-MIBI and Tc-99m-MDP scan. MATERIAL AND METHODS : Between February 1994 and December 1995,38 unselected patients with various bone pathologies were studied prospectively. Eighteen had malignant bone and soft tissue pathologies, while twenty had benign. All patients were studied with Tl-201, Tc-99mMIBI and Tc-99m-MDP scan prior to surgical biopsy. PICKER Prism 2000 gamma camera with high resolution parallel hole collimator was used for scanning. To avoid the interaction of isotope, the early(30min.) and delayed phase(3hrs.) of Tl-20l scan was performed first and Tc-99m-MIBI scan was performed after 30 minutes, and then Tc-99m-MDP scan 48 hours later. The scan images were visually evaluated by a blinded nuclear medicine physician. We could find true positive, true negative, false positive and false negative by the comparison of results with those of biopsy. We calculated positive and negative predictive value(%), sensitivity(%), specificity(%) and diagnostic accuracy(%) of each scan. RESULT : The results of each scan were 85.7, 100, 100, 85, 92.1% in Tl-201, 81, 94.1, 94.4, 80, 86.8% in Tc-99m-MIBI and 50, 66.7, 88.9, 20, 52.6% in Tc-99m-MDP scan. As a conclusion, Tl-201 scan was the most specific and accurate method for detecting malignant tumor tissue. Tc-99m-MIBI scan was also good for malignant tumor searching. CONCLUSION : With our results, we can use Tl-201 scan to differentiate benign from malignant tumor, and to evaluate the response of preoperative chemotherapy or radiotherapy, and to determine the residual tumor or local recurrence. For the better result, we need to have a more detail information about false positive cases and a more objective and quantitative reading technique.

  • PDF

Monitoring microbiological contamination, pre-decontamination, and irradiation status of commercial dried laver (Porphyra sp.) products (시판 유통 김의 미생물 오염도, 사전 살균처리 및 전자선 조사 여부 확인)

  • Lee, Eun-Jin;Kim, Gui-Ran;Lee, Hye-Jin;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • Eighteen commercial laver (Porphyra sp.) products were purchased from Korean market and were monitored for their microbial contamination, pre-decontamination, and luminescence properties. The laver samples showed considerable variation in their microbial contamination, from $10-10^7CFU/g$ of total aerobic counts, <$10-10^2CFU/g$ of coliforms in 4 dried laver samples, and <$10-10^6CFU/g$ of yeasts and molds except in 3 samples. In addition, $10^2CFU/g$ of Bacillus cereus was found in one sample. DEFT/APC analysis was suitable for demonstrating whether the samples were pre-decontaminated or not, with DEFT/APC values lower than 2.0 log for non-heated samples and 1.0-8.5 log for heatprocessed samples. In photostimulated luminescence (PSL) calibration, 15 samples irradiated at 1 kGy showed positive (irradiated) values more than 5000 PCs. Furthermore, thermoluminescence (TL) analysis by separating the marker minerals from samples revealed the potential to be employed in identifying irradiation status by determining $1^{st}$ TL glow at $125-175^{\circ}C$ and TL ratio ($TL_1/TL_2$) of all the samples.

Early Gonadogenesis and Sex Differentiation in the Korean Rose Bitterling, Rhodeus uyekii

  • Goo, In Bon;Kim, Jung Eun;Kim, Myung Hun;Choi, Hye-Sung;Kong, Hee Jeong;Lee, Jeong Ho;Park, In-Seok
    • Development and Reproduction
    • /
    • v.20 no.4
    • /
    • pp.289-296
    • /
    • 2016
  • This report describes the sex differentiation of the Korean rose bitterling, Rhodeus uyekii, from hatching to 170 days post-hatch (DPH) in relation to total length (TL), body weight (BW), and integral water temperature (IWT). The growth curve of TL from just hatching to 83 DPH was $5.144e^{0.045t}$ ($R^2=0.961$; t, time), and that of BW was $2.398e^{0.086t}$ ($R^2=0.725$). Primordial germ cells (PGCs) were observed at 17 DPH (7.9 mm TL, 3.74 mg BW, $374^{\circ}C$ IWT), and thereafter began to protrude into the peritoneal cavity. At 21 DPH ($9.2{\pm}0.14mm$ TL, $4.8{\pm}0.07mg$ BW, $462^{\circ}C$ IWT), some PGCs contained condensed chromatin and oocyte were observed in meiotic prophase. In contrast to the ovaries, which grew gradually after sexual differentiation, testes began multiplying at 25 DPH (10.1 mm TL, 5.42 mg BW, $550^{\circ}C$ IWT), when testicular differentiation was first identified, and multiplied continuously thereafter. At 33 DPH (11.2 mm TL, 10.5 mg BW, $726^{\circ}C$ IWT), the developing testes contained spermatogonia that exhibited mitotic activity. No spermatocyte or sperm cell was observed until 83 DPH (18.9 TL, 48.2 mg BW, $1,826^{\circ}C$ IWT). At 170 DPH (32.5 mm TL, 270.1 mg BW, $3,740^{\circ}C$ IWT), which was the end point of this study, the mature ovaries showed germinal vesicle breakdown, while the mature testes contained observable spermatocytes and sperm cells. These results allow us to identify the sex differentiation type of the Korean rose bitterling as differentiated gonochoristic.

Comparison of Photostimulated Luminescence, Thermoluminescence, and Electron Spin Resonance Spectroscopic Analyses on Dried-spices Irradiated by Gamma Ray and Electron Beam (감마선 및 전자선 조사 처리 건조향신료에 대한 광자극발광, 열발광 및 전자스핀공명의 분광학적 분석 비교)

  • Jeong, Jin-Hwa;Ahn, Jae-Jun;Baek, Ji-Yeong;Kim, Hyo-Young;Kwon, Joong-Ho;Jin, Chang-Hyun;Jeong, Il-Yun
    • Korean Journal of Food Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.256-261
    • /
    • 2014
  • This study was conducted to determine the effect of gamma-ray and electron-beam irradiation on dried spices (black pepper, red pepper, parsley, and basil) using the photostimulated luminescence (PSL), thermoluminescence (TL) and electron spin resonance (ESR) methods. The spices were irradiated at 0, 1, 5, and 10 kGy. All non-irradiated spices had photon counts (PCs) less than 700 PCs. The PCs of three irradiated spices (red pepper, parsley, and basil) were clearly distinguishable from those of non-irradiated ones, exhibiting PSL signals higher than 5000 PCs. However, negative PSL counts (<700 PCs) were obtained for most irradiated black pepper, except those irradiated with 5 kGy gamma rays and 10 kGy electron-beams. TL glow curves of the irradiated spices showed a higher peak at $150-250^{\circ}C$. TL ratios were found to be less than 0.1 for non-irradiated spices and higher than 0.1 for irradiated ones. No ESR signal was observed for any irradiated spice except red pepper, which displayed cellulose-based ESR spectra. Therefore, the results suggest that the PSL, TL, and ESR methods are effective detection techniques for dried spices irradiated with electron beams as well as gamma rays.

Studies on the Lipid Content and Fatty Acid Composition of Anchovy Sauce Prepared by Heating Fermentation (멸치액젓의 가온숙성중 지질함량 및 지방산 조성의 변화)

  • KIM Dong-Soo;KOIZUMI Chiaki;JEONG Bo-Young;JO Kil-Suk
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.27 no.5
    • /
    • pp.469-475
    • /
    • 1994
  • Lipid content and fatty acids composition of anchovy sauce were investigated during fermentation at $20^{\circ}C\;and\;37^{\circ}C$ for 120 days. Total lipid(TL) of raw anchovy was composed of $80.8\%$(1.98g/100g) of non-polar lipid(NL), $19.2\%$ (0.47g/100g) of phospholipid(PL) The contents of TL, NL and PL in the anchovy sauce decreased during fermentation, but the ratio of NL/TL increased from $81.1\%\;to\;90.0\%$ while that of PL/TL decreased from $18.9\%\;to\;10.0\%$. The major fatty acids in TL and NL fractions of fermented anchovy sauce were 16:0, 18:0, 18:1n-9, 16:1n-7, 18:1n-7, 20:5n-3 and 22:6n-3, 22:6n-3 was highest in the PL fraction regardless of temperature or fermentation time.

  • PDF

Detection of Irradiation Treatment for Seasoned-Powdered Foods by Thermoluminescence Measurement (Thermoluminescence 측정에 의한 조미분말식품의 방사선 조사유무 확인)

  • Chung, Hyung-Wook;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.509-516
    • /
    • 1998
  • Thermoluminescence measurements were applied to the detection of seasoned-powered foods such as shellfish extract powder, seasoned marine products, Ramen soup powder and sardine extract powder whether they are irradiated or not. Correlation coefficients $(R^2)$ between irradiation doses and corresponding TL responses were more than 0.5966 in all samples and 0.9500 in Ramen soup powder. TL threshold value was pre-established for the detection of unknown Ramen soup powders by verifying TL responses with a re-irradiation step. Threshold values were maximum 1.37 for the nonirradiated samples and minimum 6.06 for the 2.5 kGy-irradiated samples. The samples showing values between 1.37 and 6.06 were subjected to a re-irradiation step for their detection, which results were reconfirmed by enumerating the total bacterial load of the detected samples. Pre-established threshold values were successfully applicable to the detection of 167 coded unknown samples, both nonirradiated and irradiated with gamma or electron-beam energy. In the assessment of irradiated doses, three calibration curves were pre-established by plotting TL intensity versus applied doses, of which a quadratic equation was obtained for the potential estimation of irradiated doses with some variations from the real doses.

  • PDF