• Title/Summary/Keyword: TF-32

Search Result 62, Processing Time 0.026 seconds

Influence of flowable composite lining on microleakage at the gingival dentin margin (유동성 레진이 치은 상아질 변연 누출에 미치는 영향)

  • Lee, Jung-Min;Kim, Young-Kyung;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.394-402
    • /
    • 2002
  • 2급 복합레진 수복 와동의 치은 변연이 상아질 상에 있을 때 유동성 레진 이장의 유무와 두께가 미세누출에 미치는 영향을 알아보기 위해 본 실험을 시행하였다. 60개의 발거된 대구치의 근, 원심면에 각각 협설측 3mm, 치은벽 깊이 1mm의 2급 와동을 형성하고 치은 변연은 법랑-백아 경계에서 약 1mm 하방에 위치 시켰다. 모든 와동을 32% 인산으로 15초 처리 및 30초 수세 후 Prime & Bond$^{\circledR}$ NT 상아질 접착제를 적용하였고, Tetric Ceram(TC), Tetric Flow(TF)를 이용하여 다음의 6가지 군으로 나누어 수복하였다. (1) TC로 수평 적층 충전, (2) TC로 수직 적층 충전, (3) 0.5-1mm두께로 TF 이장 후 TC로 수평적층 충전, (4) 0.5-1mm 두께로 TF 이장 후 TC로 수직 적층 충전, (5) 2-3mm 두께로 TF 이장 후 TC로 수평적층 충전, (6) 2-3mm두께로 TF이장 후 TC로 수직 적층 충전. 충전된 시편을 37$^{\circ}C$ 100% humidity에서 24시간 보관하고 5$^{\circ}C$와 55$^{\circ}C$에서 500회의 열순환을 실시하여 치은 변연의 0.5mm 외부에 nail varnish를 도포 하여 2% methylene blue 용액에 12시간 침잠시켰다. 시편을 아크릴릭 레진에 매몰하여 수복물의 중앙에서 종절단 한 후 입체현미경하에서 색소의 침투도를 관찰하여 다음과 같은 결과를 얻었다. 유동성 레진의 이장을 시행한 군과 하지 않은 군간에 미세누출은 유의차를 보이지 않았다(p>0.05) 유동성 레진의 두께에 따른 미세누출의 차이는 나타나지 않았다(p>0.05) 경사면 충전법을 시행한 군에서는 유동성 레진을 이장한 군들이 이장하지 않은 군보다 유의하게 많은 누출을 보였다(p<0.05). 수평적층 충전법을 시행한 군에서는 유동성 레진 이장이 미세누출에 유의한 차이를 보이지 않았다(p>0.05).

MICROLEAKAGE OF 2-STEP ADHESIVE SYSTEMS IN DIAMOND-PREPARED CAVITY (다이아몬드 기구로 삭제한 와동에서 2단계 접착제의 미세누출 비교)

  • Lee, Myung-Goo;Cho, Kwon-Hwan;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.5
    • /
    • pp.437-444
    • /
    • 2007
  • The purpose of this study was to compare the marginal microleakage of different 2-step adhesive systems in Class V cavities prepared with different diamond points. Forty Class V cavities were prepared with two different (coarse or fine) diamond points on cervical third of extracted molars. The occlusal and gingival margin of cavities was located in enamel and dentin, respectively. They were divided into one of four equal groups (n = 10) and ; Group 1-prepared with coarse diamond point (EX-41), restored with Single Bond and Z 250, Group 2-prepared with fine diamond piont (TF-21F), restored with Sing)e Bond and Z 250, Group 3-prepared with coarse diamond point (EX-41), restored with Clearfil SE Bond and Clearfil AP-X, Group 4-prepared with fine diamond point (TF-21F), restored with Clearfil SE Bond and Clearfil AP-X. Specimens were thermocycled, immersed in a 2% methylene blue solution for 24 hours, and bisected longitudinally. They were observed leakages at enamel and dentinal margins. Data were analyzed using Mann-Whitney and Wilcoxon signed ranked test. In this study, marginal microleakage or Single Bond was not affected by type of diamond points. But Clearfil SE Bond showed higher marginal microleakage at both enamel and dentinal margin when Class V cavity was prepared with coarse diamond point.

Comparison of Voice Characteristics Before and After High-Caffeine Intake (고카페인 섭취 전·후 음성 특성 비교)

  • Lee, Areum;Kim, Eunyun;Yoo, Hyunji;Choi, Yaelin
    • Phonetics and Speech Sciences
    • /
    • v.7 no.4
    • /
    • pp.59-65
    • /
    • 2015
  • This study was conducted to identify the differences in voice characteristic variables before and after taking a certain amount of high-caffeine. Linear PCM-M10 Recorder (SONY) was used for the recorder and basic frequency of the voice (Fo), frequency fluctuation rate (jitter), amplitude fluctuation rate (shimmer) and Signal-to-Noise Ratio (SNR) were measured using TF-32(University of Wisconsin-Madison, USA). First, prolonged phonation analysis results of /ah/ by male subjects showed the shimmer values after taking high-caffeine increased statistically significantly(p<.05) compared with before the intake and SNR values significantly decreased. (p<.05). On the other hand, female subjects didn't show any statistically significant differences in all variables. Second, male subjects showed statistically significant increased shimmer values after the intake compared with before the intake at /ah/ of syllable 'na' and /ah/ in 'ra' in 'autumn' paragraph (p<.05), and jitter values significantly increased at /ah/ in 'ah' (p<.05). However, female subjects didn't show any statistically significant differences in all variables. Results of this study showed that high-caffeine intake more affects male subjects than female subjects. In male subjects, shimmer and SNR changed at vowel prolonged phonation, /ah/, and study results showed that shimmer and SNR in 'Autumn' paragraph /na/, /ra/ and jitter in /ah/ could be identified as the variables to show the voice change.

Comparison between Word Embedding Techniques in Traditional Korean Medicine for Data Analysis: Implementation of a Natural Language Processing Method (한의학 고문헌 데이터 분석을 위한 단어 임베딩 기법 비교: 자연어처리 방법을 적용하여)

  • Oh, Junho
    • Journal of Korean Medical classics
    • /
    • v.32 no.1
    • /
    • pp.61-74
    • /
    • 2019
  • Objectives : The purpose of this study is to help select an appropriate word embedding method when analyzing East Asian traditional medicine texts as data. Methods : Based on prescription data that imply traditional methods in traditional East Asian medicine, we have examined 4 count-based word embedding and 2 prediction-based word embedding methods. In order to intuitively compare these word embedding methods, we proposed a "prescription generating game" and compared its results with those from the application of the 6 methods. Results : When the adjacent vectors are extracted, the count-based word embedding method derives the main herbs that are frequently used in conjunction with each other. On the other hand, in the prediction-based word embedding method, the synonyms of the herbs were derived. Conclusions : Counting based word embedding methods seems to be more effective than prediction-based word embedding methods in analyzing the use of domesticated herbs. Among count-based word embedding methods, the TF-vector method tends to exaggerate the frequency effect, and hence the TF-IDF vector or co-word vector may be a more reasonable choice. Also, the t-score vector may be recommended in search for unusual information that could not be found in frequency. On the other hand, prediction-based embedding seems to be effective when deriving the bases of similar meanings in context.

Evaluation of Image Quality Based on Time of Flight in PET/CT (PET/CT에서 재구성 프로그램의 성능 평가)

  • Lim, Jung Jin;Yoon, Seok Hwan;Kim, Jong Pil;Nam Koong, Sik;Shin, Seong Hwa;Yoon, Sang Hyeok;Kim, Yeong Seok;Lee, Hyeong Jin;Lee, Hong Jae;Kim, Jin Eui;Woo, Jae Ryong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.110-114
    • /
    • 2012
  • Purpose : PET/CT is widely used for early checking up of cancer and following up of pre and post operation. Image reconstruction method is advanced with mechanical function. We want to evaluate image quality of each reconstruction program based on time of flight (TOF). Materials and Methods : After acquiring phantom images during 2 minutes with Gemini TF (Philips, USA), Biograph mCT (Siemens, USA) and Discovery 690 (GE, USA), we reconstructed image applied to Astonish TF (Philips, USA), ultraHD PET (Siemens, USA), Sharp IR (GE, USA) and not applied. inside of Flangeless Esser PET phantom (Data Spectrum corp., USA) was filled with $^{18}F$-FDG 1.11 kBq/ml (30 Ci/ml) and 4 hot inserts (8. 12. 16. 25 mm) were filled with 8.88 kBq/ml (240 ${\mu}Ci/ml$) the ratio of background activity and hot inserts activity was 1 : 8. Inside of triple line phantom (Data Spectrum corp., USA) was filled with $^{18}F$-FDG 37 MBq/ml (1 mCi). Three of lines were filled with 0.37 MBq (100 ${\mu}Ci$). Contrast ratio and background variability were acquired from reconstruction image used Flangeless Esser PET phantom and resolution was acquired from reconstruction image used triple line phantom. Results : The contrast ratio of image which was not applied to Astonish TF was 8.69, 12.28, 19.31, 25.80% in phantom lid of which size was 8, 12, 16, 25 mm and it which was applied to Astonish TF was 6.24, 13.24, 19.55, 27.60%. It which was not applied to ultraHD PET was 4.94, 12.68, 22.09, 30.14%, it which was applied to ultraHD PET was 4.76, 13.23, 23.72, 31.65%. It which was not applied to SharpIR was 13.18, 17.44, 28.76, 34.67%, it which was applied to SharpIR was 13.15, 18.32, 30.33, 35.73%. The background variability of image which was not applied to Astonish TF was 5.51, 5.42, 7.13, 6.28%. it which was applied to Astonish TF was 7.81, 7.94, 6.40 6.28%. It which was not applied to ultraHD PET was 6.46, 6.63, 5.33, 5.21%, it which was applied to ultraHD PET was 6.08, 6.08, 4.45, 4.58%. It which was not applied to SharpIR was 5.93, 4.82, 4.45, 5.09%, it which was applied to SharpIR was 4.80, 3.92, 3.63, 4.50%. The resolution of phantom line of which location was upper, center, right, which was not applied to Astonish TF was 10.77, 11.54, 9.34 mm it which was applied to Astonish TF was 9.54, 8.90, 8.88 mm. It which was not applied to ultraHD PET was 7.84, 6.95, 8.32 mm, it which was applied to ultraHD PET was 7.51, 6.66, 8.27 mm. It which was not applied to SharpIR was 9.35, 8.69, 8.99, it which was applied to SharpIR was 9.88, 9.18, 9.00 mm. Conclusion : Image quality was advanced generally while reconstruction program which is based on time of flight was used. Futhermore difference of result compared each manufacture reconstruction program showed up, however this is caused by specification of instrument of each manufacture and difference of reconstruction algorithm. Therefore we need further examination to find out appropriate reconstruction condition while using reconstruction program used for advance of image quality.

  • PDF

A comparison of dimensional standard of several nickel-titanium rotary files

  • Kim, Ki-Won;Cho, Kyung-Mo;Park, Se-Hee;Choi, Ki-Yeol;Karabucak, Bekir;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.1
    • /
    • pp.7-11
    • /
    • 2014
  • Objectives: The aim of this study was to compare the dimensional standard of several nickel-titanium (Ni-Ti) rotary files and verify the size conformity. Materials and Methods: ProFile (Dentsply Maillefer), RaCe (FKG Dentaire), and TF file (SybronEndo) #25 with a 0.04 and 0.06 taper were investigated, with 10 in each group for a total of 60 files. Digital images of Ni-Ti files were captured under light microscope (SZX16, Olympus) at $32{\times}$. Taper and diameter at $D_1$ to $D_{16}$ of each files were calculated digitally with AnalySIS TS Materials (OLYMPUS Soft Imaging Solutions). Differences in taper, the diameter of each level ($D_1$ to $D_{16}$) at 1 mm interval from (ANSI/ADA) specification No. 101 were statistically analyzed using one-way ANOVA and Scheffe's post-hoc test at 95% confidence level. Results: TF was the only group not conform to the nominal taper in both tapers (p < 0.05). All groups except 0.06 taper ProFile showed significant difference from the nominal diameter (p < 0.05). Conclusions: Actual size of Ni-Ti file, especially TF, was different from the manufacturer's statements.

The Effect of $WO_3$ Addition on Microwave Dielectric Properties in $BaTiO_3-3{(1-x)TiO_2-xWO_3}$ System ($WO_3$ 첨가량 변화에 따른 $BaTiO_3-3{(1-x)TiO_2-xWO_3}$ 계의 고주파 유전특성)

  • 박찬식;변재동;김왕섭;김경용
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.4
    • /
    • pp.448-454
    • /
    • 1995
  • The effect of WO3 addition on microwave dielectric properties of BaTiO3-3{(1-x)TiO2-xWO3} system was studied. Addition of WO3 to this system resulted in the formation of BaWO4 and Ba2Ti9O20 phases. Both the dielectric constant (K) and the temperature coefficientof resonant frequency (Tf) were decreased with the amount of WO3 addition. The value of Q$\times$f0 was increased as the amount of WO3 was increased up to x=0.0275, and then decreased when x exceeded 0.03. At x=0.0275, this ceramic showed excellent microwave proprties of K=34-35, Q$\times$f0=50,000-53,000, and near zero ppm/$^{\circ}C$ of Tf.

  • PDF

양자 키 분배 기술을 활용한 하이브리드 키 교환 방법

  • SIM, Dong-Hi
    • Review of KIISC
    • /
    • v.32 no.4
    • /
    • pp.99-107
    • /
    • 2022
  • 본 논문에서는 표준화 기구에서 개발되었거나 아직 개발 중인, 양자 컴퓨팅에 의한 공격에 대해 안전한 양자 내성 보안체계로의 전환을 위해 양자 키 분배 (Quantum Key Distribution - QKD) 기술을 암호키 교환에 활용하는 다양한 하이브리드 접근 방식 들을 살펴보았다. 이러한 방법들은 두 가지 이상의 서로 다른 키 교환 방법을 결합하는 '키 교환을 위한 하이브리드 접근 방식'들을 의미한다. 양자 키 분배(QKD) 네트워크에서 생성하는 대칭 키를 활용하여 다른 방식으로 생성된 암호키와의 다양한 방식의 결합을 통한 하이브리드 접근 방식의 호환성에 대해서 살펴보았고, 아울러 다양한 네트워크 계층의 보안 통신 프로토콜과 함께 QKD를 함께 사용할 수 있도록 하는 표준들을 함께 분석하였으며, 이러한 표준들에서 추가적으로 개발이 필요한 영역들을 함께 살펴보았다.

Utility of $^{99m}Tc$-MAG3 Perfusion Indices in the Evaluation of Renal Transplant Function During Early Post-transplantation Period (이식 초기 이식신 기능 평가에서 $^{99m}Tc$-MAG3 신관류 지표의 유용성)

  • Kim, Sung-Hoon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.497-507
    • /
    • 2000
  • Purpose: We have examined the utility of $^{99m}Tc$-MAG3 perfusion indices for assessing renal graft function in early post-transplantation period. Materials and Methods: Our study included 80 renal transplant recipients (48 men and 32 women, mean age: 40.3 years). Diagnosis was based on biopsy, laboratory data and clinical course. Renal scintigraphy (RS) was obtained using 100 MBq of $^{99m}Tc$-MAG3 from 11 days to 23 days of kidney transplantation. We measured 5 indices in whole-kidney (WK) and cortical (C) renograms; Hilson's perfusion index (PI), transplant perfusion index (TP) and transplant function index (TF) as perfusion parameter, and the time to peak activity (Tmax) and the ratio of renal counts at 20 min to that at 3 min (K20/3) as functional parameter. Results: The diagnoses at the day of RS were normal graft (NG) in 44, acute rejection (AR) in 14, acute tubular necrosis (ATN) in 10, and Cyclosporine A nephrotoxicity (CsA) in 12. TP and TF were significantly decreased in AR, ATN and CsA, compared to those in NG. K20/3 of AR and ATN wore significantly greater than that of NG. WK-Tmax of AR was significantly longer than that of NG. K20/3 of AR and C-K20/3 of ATN were significantly prolonged relative to those of CsA. There were no statistically significant perfusion indices among complication groups. Conclusion: TP and TF reflecting microperfusion and initial tubular extraction are reliable in assessing graft function. However, it is required to correlate perfusion indices with functional indices and clinical course in differentiating from one another among complication groups.

  • PDF

Delineating Transcription Factor Networks Governing Virulence of a Global Human Meningitis Fungal Pathogen, Cryptococcus neoformans

  • Jung, Kwang-Woo;Yang, Dong-Hoon;Maeng, Shinae;Lee, Kyung-Tae;So, Yee-Seul;Hong, Joohyeon;Choi, Jaeyoung;Byun, Hyo-Jeong;Kim, Hyelim;Bang, Soohyun;Song, Min-Hee;Lee, Jang-Won;Kim, Min Su;Kim, Seo-Young;Ji, Je-Hyun;Park, Goun;Kwon, Hyojeong;Cha, Sooyeon;Meyers, Gena Lee;Wang, Li Li;Jang, Jooyoung;Janbon, Guilhem;Adedoyin, Gloria;Kim, Taeyup;Averette, Anna K.;Heitman, Joseph;Cheong, Eunji;Lee, Yong-Hwan;Lee, Yin-Won;Bahn, Yong-Sun
    • 한국균학회소식:학술대회논문집
    • /
    • 2015.05a
    • /
    • pp.59-59
    • /
    • 2015
  • Cryptococcus neoformans causes life-threatening meningoencephalitis in humans, but the treatment of cryptococcosis remains challenging. To develop novel therapeutic targets and approaches, signaling cascades controlling pathogenicity of C. neoformans have been extensively studied but the underlying biological regulatory circuits remain elusive, particularly due to the presence of an evolutionarily divergent set of transcription factors (TFs) in this basidiomycetous fungus. In this study, we constructed a high-quality of 322 signature-tagged gene deletion strains for 155 putative TF genes, which were previously predicted using the DNA-binding domain TF database (http://www.transcriptionfactor.org/). We tested in vivo and in vitro phenotypic traits under 32 distinct growth conditions using 322 TF gene deletion strains. At least one phenotypic trait was exhibited by 145 out of 155 TF mutants (93%) and approximately 85% of the TFs (132/155) have been functionally characterized for the first time in this study. Through high-coverage phenome analysis, we discovered myriad novel TFs that play critical roles in growth, differentiation, virulence-factor (melanin, capsule, and urease) formation, stress responses, antifungal drug resistance, and virulence. Large-scale virulence and infectivity assays in insect (Galleria mellonella) and mouse host models identified 34 novel TFs that are critical for pathogenicity. The genotypic and phenotypic data for each TF are available in the C. neoformans TF phenome database (http://tf.cryptococcus.org). In conclusion, our phenome-based functional analysis of the C. neoformans TF mutant library provides key insights into transcriptional networks of basidiomycetous fungi and ubiquitous human fungal pathogens.

  • PDF