• 제목/요약/키워드: TEST-1

검색결과 60,243건 처리시간 0.07초

디지털 보청기에서의 NAL-NL1 기반 한국형 비선형 fitting formula 연구 (A Study of Korean Non-linear Fitting Formula based on NAL-NL1 for Digital Hearing Aids)

  • 김혜미;이상민
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권2호
    • /
    • pp.169-178
    • /
    • 2009
  • In this study, we suggest Korean nonlinear fitting formula (KNFF) to maximize speech intelligibility for digital hearing aids based on NAL-NL1 (NAL-nonlinear, version 1). KNFF was derived from the same procedure which is used for deriving NAL-NL1. KNFF consider the long-term average speech spectrum of Korean instead of English because the frequency characteristic of Korean is different from that of English. New insertion gains of KNFF were derived using the SII (speech intelligibility index) program provided by ANSI. In addition, the insertion gains were modified to maximize the intelligibility of high frequency words. To verify effect of the new fitting gain, we performed speech discrimination test (SDT) and preference test using the hearing loss simulator from NOISH. In the SDT, a word set as test material consists of 50 1-syllable word generally used in hearing clinic. As a result of the test, in case of moderate hearing loss with severe loss on high frequency, the SDT scores of KNFF was more improved about 3.2% than NAL-NLl and about 6% in case of the sever hearing loss. Finally we have obtained the result that it was the effective way to increase gain of mid-high frequency bands and to decrease gain of low frequency bands in order to maximize speech intelligibility of Korean.

1g 진동대실험과 전산해석에 의한 모형실험의 Size Effect에 관한 연구 (A Study on Size Effect of Model Test by 1g Shaking Table Test and One-Dimensional Ground Response Analysis)

  • 전남수;오문섭;최명진;임희대
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.755-758
    • /
    • 2010
  • 본 연구에서는 토목구조물에 대하여 상사율을 고려한 1g 진동대실험(Shaking Table Test)과 전산해석을 수행하여, 실제 지진하중(단주기, 장주기, 인공지진)에 대한 토목구조물의 안정성을 분석 및 평가 하였다. 상사율에 따른 지표면 가속도 거동을 비교 분석하기 위하여 여러 가지 상사율을 적용한 실험을 수행하여 측정된 결과와 전산해석 결과를 상호 비교 분석하여 상사비에 따른 실험결과의 적절성을 평가하였다. 상사율을 1/50과 1/50보다 크게 조성하여 진동대실험과 전산해석 결과에 의하면, 지표면 가속도의 결과는 모두 유사한 결과를 보였다. 상사율 1:50 이상인 단면의 경우 진동대실험과 전산해석 결과 사이의 유사성이 떨어지는 것으로 볼 때, 1:50 이하인 상사단면이 실제 현장에서의 거동을 모사하는데 더 높은 신뢰성을 제공하는 것으로 판단된다.

  • PDF

HEMP 방호시설의 SE 평가방법의 비교 (Comparison of SE Evaluation Methods for HEMP Shelters)

  • 정연춘;이종경;권석태
    • 한국전자파학회논문지
    • /
    • 제25권11호
    • /
    • pp.1197-1200
    • /
    • 2014
  • HEMP 방호시설의 전자파 차폐 성능을 평가하는데 사용하고자 하는 두 시험 규격, IEEE Std. 299 및 MIL-STD-188-125-1은 동일한 방호시설임에도 불구하고, 각기 다른 시험 결과를 제공한다. 특히, 10 kHz~20 MHz 대역의 저주파 자기장 영역에서는 IEEE Std. 299 규격에 의한 시험 결과가 MIL-STD-188-125-1 규격에 비해 20~30 dB 정도 더 낮게 평가됨을 확인하였다. 이러한 결과는 두 규격에서 규정하고 있는 측정 조건이 상이함에 기인하며, 따라서 측정거리의 단축을 위해 IEEE Std. 299 규격을 적용할 경우에는 기존의 MIL-STD-188-125-1 규격에 근거하여 작성된 전자파 차폐 성능 요구는 재조정되어야 한다.

Mg-Al 합금의 크리프 거동에 미치는 합금원소의 영향 (Effect of Alloying Elements on Creep Behavior of Mg-Al Alloys)

  • 임현규;김세광;김도향
    • 한국주조공학회지
    • /
    • 제32권1호
    • /
    • pp.44-49
    • /
    • 2012
  • In this study, three magnesium alloys were investigated; those are 1.5wt.% CaO added AM80, 1.0wt.% CaO added AM60, and conventional MRI153 alloys. Test specimens of three alloys were prepared by re-melting and casting into steel mold with ingots and machining. The mechanical properties and the creep behavior at 150 degrees Celsius of these specimens were determined and their microstructures were characterized using OM and SEM. For the application to die-casting, fluidity test were carried out with spiral mold. Compared with 1.0wt.% CaO added AM60 alloy, 1.5wt.% CaO added AM80 alloy exhibited good creep properties in all test conditions. Moreover, CaO added alloys showed better creep properties than MRI153 alloy at lower load condition. It is proposed that 1.5wt.% CaO added AM80 alloy is useful to apply to power-train parts such as transmission case in vehicles.

Min-Max 방법을 적용한 4:2:1 절충적 계획 (4:2:1 compromise plans using Min-Max method)

  • 최재혁;강창욱
    • 산업경영시스템학회지
    • /
    • 제21권47호
    • /
    • pp.1-10
    • /
    • 1998
  • Testing high reliability devices under nomal operating condition is difficult, because the devices are not likely to fail in the relatively short time available for tests. For most applications it is necessary to accelerate the causes of failure by increasing a stress above its nomal value. Previous accelerated life test(ALT) plans have shown how to find optimum allocation, lowest stress and sample size subject to minimizing the variance of mean life estimator. In these ALT plans, the highest acceptable test-stress was assumed to be specified in advance by the experimenter but there is no guidance for selecting it. This assumption is, however, inappropriate for many applications. Testing devices at too-high stress levels can invalidate the extrapolation model, or introduce failure mechanisms that are not anticipated under nomal operating conditions. In this paper, we propose new 4:2:1 compromise plans using Min-Max method to minimize this risk and present minimized test-stress levels(max, middle, min), and find sample allocation based on Min-Max 4:2:1 compromise plans. In result, we compare previous 4:2:1 compromise plans specified maximum test-stress with Min-Max 4:2:1 compromise plans minimized maximum test-stress.

  • PDF

The First Report to Evaluate Safety of Cyanobacterium Leptolyngbya sp. KIOST-1 for Use as a Food Ingredient: Oral Acute Toxicity and Genotoxicity Study

  • Lee, Youngdeuk;Kim, Taeho;Lee, Won-Kyu;Ryu, Yong-Kyun;Kim, Ji Hyung;Jeong, Younsik;Park, Areumi;Lee, Yeon-Ji;Oh, Chulhong;Kang, Do-Hyung
    • Journal of Microbiology and Biotechnology
    • /
    • 제31권2호
    • /
    • pp.290-297
    • /
    • 2021
  • Leptolyngbya sp. KIOST-1 (LK1) is a newly isolated cyanobacterium that shows no obvious cytotoxicity and contains high protein content for both human and animal diets. However, only limited information is available on its toxic effects. The purpose of this study was to validate the safety of LK1 powder. Following Organisation for Economic Co-operation and Development (OECD) guidelines, a single-dose oral toxicity test in Sprague Dawley rats was performed. Genotoxicity was assessed using a bacterial reverse mutation test with Salmonella typhimurium (strains TA98, TA100, TA1535, and TA1537) and Escherichia coli WP2 uvrA, an in vitro mammalian chromosome aberration test using Chinese hamster lung cells, and an in vivo mammalian erythrocyte micronucleus test using Hsd:ICR (CD-1) SPF mouse bone marrow. After LK1 administration (2,500 mg/kg), there were no LK1-related body weight changes or necropsy findings. The reverse mutation test showed no increased reverse mutation upon exposure to 5,000 ㎍/plate of the LK1 powder, the maximum tested amount. The chromosome aberration test and micronucleus assay demonstrated no chromosomal abnormalities and genotoxicity, respectively, in the presence of the LK1 powder. The absence of physiological findings and genetic abnormalities suggests that LK1 powder is appropriate as a candidate biomass to be used as a safe food ingredient.

Kolmogorov-Smirnov Type Test for Change with Sample Fourier Coefficients

  • Kim, Jae-Hee
    • Journal of the Korean Statistical Society
    • /
    • 제25권1호
    • /
    • pp.123-131
    • /
    • 1996
  • The problerm of testing for a constant mean is considered. A Kolmogorov-Smirnov type test using the sample Fourier coefficients is suggested and its asymptotic distribution is derived. A simulation study shows that the proposed test is more powerful than the cusum type test when there is more than one change-point or there is a cyclic change.

  • PDF

진단용 X선발생장치의 X선관 가변조리개 성능검사와 조사야일치검사 및 중심선속 일치검사에 대한 평가 (Evaluation to X-ray Tube Variable Beam Limiting Device Ability Test, Collimation and Beam Alignment Test of Diagnostic X-ray Unit)

  • 임인철;이상훈
    • 한국콘텐츠학회논문지
    • /
    • 제9권3호
    • /
    • pp.250-255
    • /
    • 2009
  • 본 연구는 경남 김해지역내의 병원에서 사용되고 있는 진단용방사선발생장치 중 일반촬영용장비 40대를 X선관 가변조리개 성능검사와 광조사야와 실제 X선조사야면의 일치검사 및 초점과 가변조리개의 중심선속 일치검사를 통해 장비의 성능을 평가 조사하여 다음과 같은 결과를 얻을 수 있었다. 1. 가변조리개 성능검사에서 최대X선조사야시험 결과는 부적절한 장비가 4대(10%), 최소X선조사야시 험결과에서는 5대(12.5%)로 나타났다. 2. 광조사야와 X선조사야일치시험 결과에서는 최대허용치인 2%이내가 23대(57.5%), 2%이내를 벗어난 장비가 17대(42.5%)로 나타났다. 3. 중심선속 일치시험 결과에서는 완전일치가 11대(27.5%), $0.5^{\circ}$이내로 벗어난 경우는 11대(27.5%), $0.6^{\circ}-1.5^{\circ}$이내가 10대(25%), $1.6^{\circ}-3^{\circ}$이내가 7대(17.5%), $3^{\circ}$이상인 경우가 1대(2.5%)로 나타났다. 결론적으로 가변조리개 중 일부가 기준치에 떨어진 성능상태에서 사용하고 있었으며, 광조사야와 X선 조사야일치상태 및 중심선속 일치에서도 최대허용치를 벗어난 상태에서 상당수의 장비를 사용하고 있었다. 그러므로 피검자의 방사선 피폭을 최소화하고 영상의 질을 향상시키기 위해서는 주기적이고 지속적인 점검평가를 거쳐 노후화 되었거나 부족한 성능상태의 기기를 수리, 보완해야함을 알 수 있었다.

철근콘크리트 축소모델의 부재거동 상사성에 관한 연구 (A Study on the Similitude of Member Behavior for Small-Scale Modeling of Reinforced Concrete Structure)

  • 장진혁;이한선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.187-192
    • /
    • 1995
  • Four types of experiments were performed to check the similitude of member behavior between prototype and 1/10 scale models:(1) Test of slender columns with P- effect, (2)Test of short columns with and without confinement steel, (3)Test of simple beams without stirrups, and (4)T-beam test. Based on the results of experiments, the conclusions were made as follows : (1) The P- effect of slender columns can be almost exactly represented by 1/10 acale model. (2)The effect of confinement on short columns by the hoop steel can also roughly simulated by 1/10 scale model. (3)The failure modes of simple beams models were the yielding of tension steel followed by large diagonal tension cracking+compressive concrete failure. (4)The behaviors of prototype and 1/10 scale model in T-beams appear very similar.

  • PDF