• Title/Summary/Keyword: TEST-1

Search Result 59,887, Processing Time 0.082 seconds

Repeatability and Reliability of a New Phoria Test Using Flashed and Auto-flashed Presentation

  • Moon, Byeong-Yeon;Park, Sun-Young;Cho, Hyun Gug
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.418-424
    • /
    • 2012
  • The purpose of this study was to assess repeatability and reliability of a new phoria test as compared to established phoria tests and to assess the possibility of mobile or online testing using the auto-flashed presentation. Near dissociated phoria was measured using the von Graefe method, the Howell card test, the modified Thorington test, and a new dichromatic card test (Red-Blue Phoria card test; RBP card test) on 109 subjects. The inter-examiner difference and test-retest difference were calculated. With the auto-flashed presentation of the RBP card test, near dissociated phoria was measured and the intraclass correlation coefficient and test-retest repeatability was assessed on 26 subjects. The variation in inter-examiner repeatability was the smallest for the modified Thorington test (+3.1/-2.6). The RBP card test was +3.0/-3.1, the Howell card test was +3.5/-2.7, and the von Graefe test was +6.2/-6.0. The variation in test-retest repeatability was the smallest for the RBP card test (+0.4/-1.4). The modified Thorington test was +1.3/-1.3, the Howell card test was +1.27/-1.45, and the von Graefe test was +1.59/-2.20. The ICC was 0.919 for the auto-flashed presentation of the RBP card test. The RBP card test is considered a highly repeatable method clinically and can be made a useful application for testing in mobile or online.

Electric Degradation of Failure Mode of Solar Cell by Thermal Shock Test (열충격 시험 후 태양전지 파괴 모드에 따른 전기적 특성변화)

  • Kang, Min-Soo;Jeon, Yu-Jae;Shin, Young-Eui
    • Journal of Energy Engineering
    • /
    • v.22 no.4
    • /
    • pp.327-332
    • /
    • 2013
  • 일본 연구에서는 열충격 시험을 통한 태양전지의 파괴모드에 따른 전기적 특성을 분석하였다. 시편은 Photovoltaic Module을 만들기 전 3 line Ribbon을 Tabbing한 단결정 Solar Cell을 제작하였다. 열충격 시험 Test 1의 온도조건은 저온 $-40^{\circ}C$, 고온 $85^{\circ}C$, Test 2는 저온 $-40^{\circ}C$, 고온 $120^{\circ}C$에서 Ramping Time을 포함하여 각각 15분씩, 총 30분을 1사이클로 500사이클을 각각의 조건으로 수행하였다. 열충격 시험 후 Test 1에서는 4.0%의 효율 감소율과 1.5%의 Fill Factor 감소율을 확인하였으며, Test 2에서는 24.5%의 효율 감소율과 11.8%의 Fill Factor 감소율을 확인하였다. EL(Electroluminescence)촬영 및 단면을 분석한 결과, Test 1과 Test 2 시편 모두 Cell 표면 및 내부에서의 Crack이 발견되었다. 하지만, Test 2의 시험이 Test 1보다 가혹한 온도조건의 시험으로 인해 Test 1에서 나타나지 않았던, Cell 파괴를 Test 2에서 확인하였다. 결국, Test 1에서 효율의 직접적인 감소 원인은 Cell 내부에서의 Crack이며, Test 2에서는 Cell 내부에서의 Crack 및 Cell 파괴로 인한 Cell 자체의 성능저하로 효율이 크게 감소한다는 것을 본 실험을 통하여 규명하였다.

Reliability of Measured Popliteal Angle by Traditional and Stabilized Active-Knee-Extension Test

  • Kim, Min-Hee;Kim, Yong-Wook;Jung, Doh-Heon;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.16 no.4
    • /
    • pp.1-7
    • /
    • 2009
  • The active-knee-extension (AKE) test has been used to measure hamstring muscle length. The traditional AKE test measures the popliteal angle to the point of resistance with a 90-degree flexion of the hip fixed by straps, while the stabilized AKE test measures the popliteal angle to the point of resistance with a 90-degree flexion of the hip stabilized using a pressure biofeedback unit providing lumbopelvic stabilization. The purpose of this study was to determine test-retest reliability of the traditional AKE test and stabilized AKE test. Twenty healthy adults participated in the study. The popliteal angles were measured with a digital inclinometer during each test. To assess the test-retest reliability between the 2 test sessions, intraclass correlation coefficients (ICCs) were calculated. The intrasubject coefficient of variation ($CV_{intra}$) was also calculated. To compare the traditional and stabilized AKE tests for changes in pressure, paired t-tests were applied. The results of this study were as follows: 1) ICCs(3,1) value for test-retest reliability was .96 in the traditional AKE test, and was .98 in the stabilized AKE test. 2) The maximal $CV_{intra}$ was 33.7% in the traditional AKE test and 15.7% in the stabilized AKE test. 3) Differences of $6.1{\pm}2.1$ mmHg in pressure were measured in the traditional AKE test, and differences of $1.2{\pm}1.0$ mmHg in pressure were measured in the stabilized AKE test. The results show the traditional and stabilized AKE test to be highly reliable, with test-retest reliability. However, the stabilized AKE test represented less variation and more stabilization than the traditional AKE test. Further study is needed to measure the inter-rater reliability of the stabilized AKE test for generalization and clinical application.

  • PDF

SERO-EPIDEMIOLOGICAL STUDY OF BRUCELLOSIS AMONG GOATS AND SHEEP AT PESHAWAR DISTRICT

  • Ghani, M.;Siraj, M.;Zeb, A.;Naeem, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.8 no.5
    • /
    • pp.489-494
    • /
    • 1995
  • Sero-epidemiological study was carried out to observe the prevalence of brucellosis in 500 slaughtered as well as in 500 healthy animals in Peshawar district of N.W.F.P. All serum samples were subjected to four serological tests i.e. Standard Plate Test (SPT), Standard Tube Test (STT), Rivanol Test (RV) and 2, Mercapto-Ethanol Test (2, ME). The incidence of disease in 500 healthy animals tested by standard plate test, standard tube test, rivanol test and 2, Mercapto-ethanol test, was 2.8%, 1.8%, 1.6% and 1.2% respectively. While the incidence of brucellosis in 500 slaughter animals from Peshawar abattoir was 3.0%, 2.2%, 2.00% and 1.2% by standard plate test, standard tube test, rivanol test and 2, Mercapto-ethanol test The disease prevalence was higher in slaughtered animals as compared to healthy animals. The disease was more common in goats than sheep, also more prevalence in aged female than younger stocks. The efficacy of SPT was found more effective as compared to STT, RV, and 2, ME tests both in slaughtered as well as apparently healthy animals at Peshawar district. Standard Plate test detected 2.9%, Standard Tube test 2.0%, Rivanol test 1.8% and 2, Mercapto-ethanol test detected 1.2% positive cases in slaughtered as well as in healthy animals. So the Standard Plate Test was found to be more reliable, sensitive, and easy to performed.

The Effect of Test Anxiety,Intelligence, and Item Arrangement Order on Test Performance in Earth Science (시험불안(試驗不安) 지능(知能) 및 문항배렬(問項配列) 방식(方式)이 지구과학(地球科學) 의험수행(議驗遂行)에 미치는 효과(效果))

  • Kim, Sang-Dal;Yi, Hyang-Sun;Hwang, In-Ho
    • Journal of The Korean Association For Science Education
    • /
    • v.11 no.2
    • /
    • pp.161-178
    • /
    • 1991
  • This study was designed to investigate the effect of test anxiety, intelligence, and item arrangement order on test performance in Earth Science. The main purposes in this study were to investigate (1) (2) (3) (4) on test performance.: (1) the effect of test anxiety components on test performance in Earth Science. (2) the effect of item arrangement order on test performance in Earth Science. (3) the effect of test anxiety This study was designed to investigate the effect of test anxiety, intelligence, and item arrangement order on test performance in Earth Science. The main purposes in this study were to investigate (1) (2) (3) (4) on test performance.: (1) the effect of test anxiety components on test performance in Earth Science. (2) the effect of item arrangement order on test performance in Earth Science. (3) the effect of test anxiety components on test performance in Earth Science according to learner's intelligence levels. (4) test effect of item arrangement order on learner's intelligence. The hypothesis was that there is difference among test achievements scores according to (1) test anxiety-worry levels. (2) item arrangement orders. (3) item arrangement orders on test anxiety-worry levels. (4) test anxiety-worry levels on intelligence levels. (5) test anxiety-emotionality levels. (6) item arrangement orders on test anxiety-emotionality levels. (7) test anxiety-emotionality levels on intelligence levels. (8) item arrangement orders on intelligence levels. The test items selected for this study were derived from the text Science (part 1) first grade of high school. The subjects of this study were 164 of high school first grade boy students in Pusan. They were assigned to one of the three groups, according to test anxiety levels.: (1) upper 25% of total subjects designated to high group (2) middle 50% (3) low group, lower 25% of total subjects And according to LQ. (1) upper 25% of total subjects designated to high group. (2) middle 50%. (3) low group, lower 25% of total subjects Analysis of variance was used in this study for hypothesis examination. The dependent variable was the achievement scores of Earth Science test and independent variables were test anxiety(worry, emotionality) level, LQ. level, item arrangement orders. The principal findings of the present study are as follows: (1)Test achievement score trend decreases as the test anxiety (worry, emotionality) increases although the result is not statistically significant. (2)There is no significant difference among test achievement scores according to item arrangement orders. (3)The higher the LQ. is, the more effective test anxiety. And the LQ. has significant interaction effect with test anxiety. (4)There is significant interaction effect between the LQ. levels and itemqr arrangement orders.

  • PDF

The Effects of Aromatherapy on Depression, Sleep, Mood, and Smell in Stroke Patients and Their Caregivers (향기흡입이 뇌졸중환자와 돌봄 제공자의 우울, 수면, 기분 및 냄새에 미치는 효과)

  • Suh, Soon-Rim;Seo, Ji-Yeong;Choi, Eun-Hee;Park, Wan-Ju
    • Research in Community and Public Health Nursing
    • /
    • v.19 no.1
    • /
    • pp.27-35
    • /
    • 2008
  • Purpose: The purpose of this study was to examine the effects of aroma-inhalation on depression, sleep, mood, and smell in stroke patients and their caregivers. Method: This study employed one group pretest-posttest repeated design. Data were collected at three time points: baseline(pre-test), 10 days and 20 days after the intervention(Post-test1 and post-test2, respectively). The sample included a total of 23 subjects. Data were analyzed by SPSS 12.0 program using repeated measure ANOVA. Results: Depression was not statistically significant difference among pre-test, post-test1 and post-test2. Sleep was improved after intervention $37.61{\pm}7.41$(pre-test), $41.22{\pm}8.26$ (post-test1), $44.33{\pm}7.67$(post-test2) (F=8.182. p=.001) Mood was significantly improved after intervention: $16.95{\pm}4.89$(pre-test), $14.89{\pm}6.31$(post-test1), $12.11{\pm}5.04$(post-test2). Smell including smell perception, discomfort due to smell and relation between age and smell was significantly improved after intervention: $2.63{\pm}1.20$ (pre-test). $2.00{\pm}1.16$(post-test1), $1.63{\pm}.96$(post-test2) (F=6.176. p=.006) in smell perception, $2.50{\pm}1.10$ (pre-test). $1.81{\pm}.91$(post-test1), $1.19{\pm}.40$(post-test2) (F=12.26. p=.000) in discomfort due to smell and $3.53{\pm}1.18$(pre-test). $2.59{\pm}1.46$(post-test1), $2.53{\pm}1.33$(post-test2) (F=4.148, p=.025) in relation between age and smell. Conclusion: The results suggest that aroma-inhalation may have an effect on sleep, mood and smell and can be effective nursing intervention to increase the relaxation in stroke patients and their caregivers.

  • PDF

Design of PCI/USB Interface Controller with IEEE 1149.1 Test Function (IEEE 1149.1 테스트 기능이 내장된 PCI/USB 통합 인터페이스 회로의 설계)

  • Kim, Young-Hun;Kim, Ki-Tae;Park, Sung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.10 s.352
    • /
    • pp.54-60
    • /
    • 2006
  • In order to test the board with IEEE 1149.1 boundary scan design, the test sequence must be applied as the bit stream However it is very tedious job to generate the test bit sequence since it requires the complete hlowledge about the 1149.1. This fuper introduces a convenient PCI/USB interface controller, named as Test-Ready PCI (TRPCI) ard Test-Ready USB (TRUSB). Test Bus Controller has been developed by TI and Lucent aiming to generate the test bit stream as an instruction level, thus even the novice test engineer can easily generate the test sequence.

Test Method with TSS in Bluetooth Baseband (블루투스 베이스밴드의 Test Suite Structure에 의한 테스트 방안)

  • Moon, Sang-ook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.997-999
    • /
    • 2005
  • In order for efficient Bluetooth Baseband functional test, Bluetooth SIG (Special Interest Group) provides with Test Suite Structure (TSS) in the Bluetooth specification version 1.1. Bluetooth Baseband hardware which needs to be authenticated should implement the test specification defined in the TSS part I.1 through I.3. In this paper, we discuss the method to verify and test a Bluetooth Baseband implementation based on the TSS version 1.0. Also, we describe various senario and implementation possibilities to perform the Bluetooth Baseband authentication test.

  • PDF

Study on Thermal Environmental Test for XKT-1 (KT-1 Export Version) Aircraft (XKT-1(수출형 KT-1) 항공기 열 환경시험에 관한 연구)

  • Kim, Jinseog
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.3
    • /
    • pp.105-113
    • /
    • 2021
  • This paper delineates the applied thermal environmental test profiles using test conditions and procedures based on MIL-STD-810 Method 501 (High Temperature Test Method) and Method 502 (Low Temperature Test Method). The test profiles have been optimized in order to comply with export customer's requirements and product reliability in high and low temperature environment for XKT-1 (KT-1 Export Version) aircraft. Additionally, the tests are suitable for large sized environmental chambers, which is one of the facilities of ADD (Agency for Defense Development) according to ETEMP (Environmental Test and Evaluation Master Plan). The results of these test profiles and test executions satisfy the customer requirements and product reliability. The present paper can be applied to the other export programs with more severe temperature conditions.

A Study on Technique of Development Test by an Aircraft Captive Flight Test in Weapon System (무기체계의 항공기 탑재비행시험을 통한 개발시험 기법 연구)

  • Yeom, Hyeong-Seop;Oh, Jong-Hoon;Sung, Duck-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.10
    • /
    • pp.1010-1016
    • /
    • 2009
  • In this paper, we have described an aircraft captive flight test for the development test of weapon systems. We have conducted a captive flight test for the development of core onboard parts and sensors of airborne weapons and guided missiles. We have used KTX-1/XKO-1 aircraft as a platform for the captive flight test. In order to perform a captive flight test, we have made a captive test pod as a shape of external fuel tank in the XKO-1 and have modified XKO-1 aircraft for a system interface. We have taken a development test about all kinds of seekers, navigation & guidance systems, and core part of guided missile through the aircraft captive flight test.