• 제목/요약/키워드: TEST CELL

검색결과 4,630건 처리시간 0.036초

제강슬레그의 연직배수재로서의 활용에 관한 연구 (The Application of Converts Slag for Vertical Drains)

  • 김용수;정승용;한기현;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.623-630
    • /
    • 2000
  • In this study, it was to investigate the possibility to use the converts slag, by product in producing steel as a substitute material with sand that is used fur a civil construction materials, in developing techniques to use converts slag to improve soft clay ground. To do this, it was investigated the physical and mechanical properties of the converts slag as a civil construction material. For this, cylindrical cell consolidation with a single vertical drains and large scale soil box test were performed. Through large scale soil box test, the applicability of the converts slag to the present vertical drain techniques which is dependent on sand and plastic drains was studied. As a result of that, it was found that the shape of inserted drains was maintained after completing a consolidation process of a soft clay with slag drains. In addition, we could find that the slag drains showed the similar results with sand drains in soft clay by analyzing the effect of acceleration of consolidation.

  • PDF

Water-Side Oxide Layer Thickness Measurement of the Irradiated PWR Fuel Rod by ECT Method

  • Park, Kwang-June;Chun, Yong-Bum
    • Nuclear Engineering and Technology
    • /
    • 제29권2호
    • /
    • pp.175-180
    • /
    • 1997
  • It has been known that eater-side corrosion of fuel rods in nuclear reactor is accompanied with the metallic loss of wall thickness and hydrogen pickup in the fuel dadding tube. The fuel dad corrosion is one of the major factors to be controlled to maintain the fuel integrity during reactor operation. An oxide later thickness measuring device equipped with ECT probe system was developed by KAERI, and whose performance test was carried out in NDT(Non-destructive Test) hot-cell or PIE(Post Irradiation Examination) Facility. At first, the calibration/performance test was executed for the unirradiated standard specimen rod fabricated with several kinds of plastic thin films whose thickness ore predetermined, and the result of which showed a good precision within 10% of discrepancy. And then, hot test us peformed for the irradiated fuel rod selectively extracted from J44 fuel assembly discharged from Kori Unit-2. The data obtained with this device were compared with the metallographic result obtained from destructive examination in PIEF hot-cell on the same fuel rod to verify the validity of the measurement data.

  • PDF

부식촉진시험에 의한 콘크리트 내의 철근의 부식 모니터링에 관한 실험적 연구 (An Experimental Study on the Corrosion Monitoring of Reinforcing Steel in Concrete by the Accelerated Corrosion Test)

  • 배수호;정영수;김진영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.543-548
    • /
    • 2001
  • The corrosion monitoring methods of reinforcing steel in concrete are the various methods such as half cell potential method, galvanic current method, resistivity method, polarization resistance method, AC impedance method and etc. In this study, the corrosion monitoring methods of reinforcing steel in concrete were investigated for the test specimens using corrosion inhibitors, zinc-mortar, zinc-plate, respectively. For this purpose, the accelerated corrosion tests for reinforcing steel were conducted according to the periodic cycles(140 days) of wetting($65^{\circ}C$, 90% R.H.) and drying period(15$^{\circ}C$ , 65% R.H.) for the test specimens. As a result, it can be concluded from the test that half cell potential and galvanic current method as monitoring techniques for corrosion were found to be relatively reliable and easily usable method in the field.

  • PDF

Iosipescu Shear Test를 이용한 고분자 복합재료의 종방향 전단계수 연구 (Effective Longitudinal Shear Modulus of Polymeric Composite Using Iosipescu Shear Test)

  • 정태헌;권용수;이유태;이동주
    • 한국산업융합학회 논문집
    • /
    • 제3권1호
    • /
    • pp.61-67
    • /
    • 2000
  • Effective shear modulus of continuous fiber reinforced polymeric composites is measured using a modified Iosipescu Shear Test(IST) and compared with data obtained by finite element analyses that a concept of unit cell is. It is found that the numerical results of the longitudinal shear modulus give a good agreement with experimental data at lower fiber volume fraction. In this paper, both the distance and stress transfer between the fibers are discussed as the major factors.

  • PDF

DSP 칩과 최적분별법을 이용한 새로운 혈구입자 계수기 설계 (A New Design of Blood Cell Counter using DSP chip and Optimal Discrimination Method)

  • 김규학;김종원;김근섭;홍완희;김성환
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1991년도 춘계학술대회
    • /
    • pp.89-93
    • /
    • 1991
  • The purpose of this reserch is to design the blood cell counting instrument which can measure the number of RBC(Red Blood Cell) and WBC(White Blood Cell) including many other blood component. The proposed method uses the electrical impedence method and the new discrimination method wi th DSP chip and software algorithm. The system consist of control unit, blood cell discrimination unit, hemoglobin spectrometer, post detect ion processor unit, and IBM-PC interface unit. In this paper, the discrimination system has been implemented using digital signal processor, which result in the reduction of system hardware and cost. The system is helpful in providing necessary clinical test for screen test and quality control of hematology.

  • PDF

1kW 이하의 평판형 SOFC 스택제작 및 성능평가 (Fabrication and Performance Test in Stacks of Planar Solid Oxide Fuel Cell under 1kW)

  • 조남웅;황순철;한상무;김영우;김승구;전재호;김도형;전중환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.121-124
    • /
    • 2007
  • Stacks of solid oxide fuel cell under 1kW max power were designed on planar type employing anode supported cell and metallic interconnects. The stacks composed of 3-cells, 8-cells, and 16-cells were fabricated by using single cell purchased from Indec, sealant and interconnect prepared at RIST. In performance test of the final 16-cells stacks, OCV was recorded to be 16.7 V. Peak power and power density were 1 kW, 0.77 $W/cm^{2}$ at $820^{\circ}C$, respectively. In addition, the long term degradation rate of the power exhibited 2.25 % in 500 h at $750^{\circ}C$.

  • PDF

수소연료전지자동차 연료소비율 평가기술 개발에 관한 연구 (Development on Fuel Economy Test Method for Hydrogen Fuel Cell Vehicles)

  • 임종순;이현우;홍윤석;이광범;용기중;권해붕
    • 한국수소및신에너지학회논문집
    • /
    • 제21권3호
    • /
    • pp.207-213
    • /
    • 2010
  • Fuel consumption measurement of hydrogen fuel cell vehicle is considerably different from internal combustion engine vehicle such as carbon balance method. A practical method of fuel consumption measurement has been developed for hydrogen fuel cell vehicles. There are three method of hydrogen fuel consumption testing, gravimetric, PVT (pressure, volume and temperature), and mass flow, all of which necessitate physical measurements of the fuel supply. The purpose of this research is to measure the fuel consumption of hydrogen fuel cell vehicles on chassis-dynamometer and to give information when the research is intended to develop test method to measure hydrogen fuel economy.

국제표준에 대비한 국내 비자동저울의 품질평가에 관한 연구 (Quality Assessment of Domestic Non-automatic Weighing Instruments for International Standards)

  • 남궁재관;공재향
    • 한국공작기계학회논문집
    • /
    • 제13권6호
    • /
    • pp.127-134
    • /
    • 2004
  • As the result of reduction of the barrier of national economy on matters of quality assurance of weighing instruments in recently, it is considering in domestic as well as international matters. Therefore, this study is to analysis and compare with international md national measuring standards on the electric self-indicating scale, to improve the quality of electronic machine by providing a reformation plan on currently problems of domestic manufactured, and to identify to introduce in domestic criteria from international standards. I had compared KSC 1313 to OIML R 76-1 as the performance assessment items, such as metrology Properties test, static temperature test, temperature effect testing under the un-load, electronic wave disturbance test, high-tempereature and high-humidity stability test and durability test. Therefore, only one company is passed all items of the test according to the international (reference) standards, but it is possible to improve the quality in general if it should be use the load cell and electric components which is stability of temperature change in order to supplementation to the static temperature test and temperature effect testing under the un-load. It is also possible to apply in the domestic with the OIML 76-1 after correcting the design.

PCR 기법 이용 VTe 분비 대장균 검출 (Detection of VTe-producing E coli using PCR method)

  • 윤순식;박남용;임정택
    • 대한수의학회지
    • /
    • 제36권3호
    • /
    • pp.607-614
    • /
    • 1996
  • Several methods for rapid and accurate detection of VTe-producing E coli were established. These methods contain beta-glucuronidase-secretion test, beta-haemolysis-production test in blood agar, verocytotoxicity test, and PCR. All of the VTe-producing strains made beta-haemolysis on 5% sheep blood agar. VTe-producing strains secreted beta-glucuronidase whereas 0157:H7 strains producing VTI or VTII did not secrete that enzyme. Verocytotoxicity test was established for rapid diagnosis. VTe detection was rapider in Vero cell suspension than Vero cell monolayer. In PCR, there was a positive result only in VTe-producing E coli, not in VTI or VTII-producing E coli. In this experiment, 165 strains of E coli were islated from feces or intestinal contents of post-weaning piglets showing nervous sign or diarrhea. And 20 strains of E coli that produced VTe were selected by verocytotoxicity test and PCR. According to these experiments, there was a direct correlation between verocytotoxicity test and PCR. And verocytotoxicity test is recommended as a routine diagnostic method and PCR does as a accurate diagnostic method to detect VTe-producing E coli.

  • PDF

공장 자동화를 위한 지능 생산 시스템 개발에 관한 연구 (Study of Intelligent Manufacturing System Development for Factory Automation)

  • Park, K.H.
    • 한국정밀공학회지
    • /
    • 제14권7호
    • /
    • pp.126-136
    • /
    • 1997
  • This paper describes a task level cell programming environment that deals with difficulties in programming Flexible Manufacturing Cells (FMCs), and consists of the cell programming editor and the automatic generation module. In the cell programming editor, cell programs can be developed with task- oriented cell specifications that reduces the amount of details to be considered by cell programmers. The automatic generation module transforms task specifications into executable programs used by cell constituents. The development tool in designing the environment is an object-oriented approach which provides a simple to use and intuitive user interface, and allows for an easy development of object models associated with the environment. Test results are illustrated in order to demonstrate the applicability of the developed envifonment.

  • PDF