• 제목/요약/키워드: TEMPERATURE DATA LOGGER

검색결과 63건 처리시간 0.024초

Comparison of the Meteorological Factors on the Forestland and Weather Station in the Middle Area of Korea

  • Chae, Hee Mun;Yun, Young Jo
    • Journal of Forest and Environmental Science
    • /
    • 제34권3호
    • /
    • pp.249-252
    • /
    • 2018
  • Climate is one of most important environmental factors on the forest ecosystem. This study was conducted to analyze the characteristics of meteorological factors in the forest area and weather stations from July 2015 to June 2016 in Cheuncheon and Hongcheon of Kangwon Province in Korea. The HOBO data logger was installed for meteorological analysis in forests area (site 1 and site 2). The meteorological data from the HOBO data logger compared with meteorological data of the weather station. The meteorological data used for the analysis was monthly mean temperature ($^{\circ}C$), monthly mean minimum temperature ($^{\circ}C$), monthly mean maximum average temperature ($^{\circ}C$), and monthly mean relative humidity (%). As a result of this study, the mean temperature ($^{\circ}C$) of forest area was relatively lower than weather station which is the outside the forest area, and the mean maximum temperature ($^{\circ}C$) of weather station was relatively higher than that of forest area. The mean relative humidity (%) was higher in forest area than weather station.

소형 풍력발전 적용 풍력자원조사를 위한 데이터로거 개발 (A Development of Dedicated Data Logger for Wind Resource of Small Wind Power Generator)

  • 윤영천;정문선;김상만;김태곤;문채주
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.146-152
    • /
    • 2012
  • To install a wind power generator, the survey on the wind environment resources must be conducted in advance. The survey on the wind environment resources is to collect and analyze data regarding the wind speed and direction on a data logger. The data logger consists of a sensor, signal processing circuit and storage device. According to the analysis of the stored data, the amount of power generation by the types of generators can be predicted and the most optimal generator including safety grade can be selected, and in case of installing a generator in the future, it can be utilized as basic data regarding supporting base and foundation construction method of survey points. Data logger was developed for a small wind power generator that is suitable for the international standard(IEC 61400) by using DSP-F28335 micro controller in this paper. It was developed to measure the wind speed of 1 [m/s]~17 [m/s], the wind direction of 0 [$^{\circ}$]~359 [$^{\circ}$], and temperature of -30 [$^{\circ}C$]~50 [$^{\circ}C$], and the comparative experiment with other companies' data loggers was conducted, and an error was measured to be less than ${\pm}0.1$ [m/s] for wind speed and less than +1 [$^{\circ}$] for wind direction.

목본식물 형성층 전기저항에 영향을 주는 환경 요인 (Effects of Environmental Factors on the Cambial Electrical Resistance of Woody Plants)

  • 김동욱;김민수;이부용
    • 한국조경학회지
    • /
    • 제35권3호
    • /
    • pp.105-113
    • /
    • 2007
  • This study was conducted to analyze the effects of environmental factors such as soil moisture, light intensity, temperature and humidity on changes in cambial electrical resistance. To improve data quality, cambial electrical resistance was continuously measured at fixed points by using a data logger isolated from alternating current. The relationship between environmental factors and changes in cambial electrical resistance was also analyzed. The results are as follows: 1. Cambial electrical resistance is highly correlated to the temperature of the measured area(r=-0.934). Therefore, temperature compensation is needed to analyze the effects of other environmental factors on cambial electrical resistance changes. 2. If temperature is compensated for, the change of cambial electrical resistance is highly correlated to water vapor pressure(r=-0.836). 3. If temperature and humidity are compensated for, the change of cambial electrical resistance is highly correlated to intensity of light(r=-0.738). 4. Diurnal deviation of soil water potential is not more significantly related than the change of cambial electrical resistance. However, in the long-term, soil water potential and cambial electrical resistance are highly correlated(r=-0.831). This indicates that soil moisture significantly influences the long-term change of cambial electrical resistance.

식중독 발생 위해인자로서 가정용 냉장고의 온도에 대한 확률분포 분석 (Statistical Probability Analysis of Storage Temperatures of Domestic Refrigerator as a Risk Factor of Foodborne Illness Outbreak)

  • 박경진
    • 한국식품과학회지
    • /
    • 제42권3호
    • /
    • pp.373-376
    • /
    • 2010
  • 본 연구는 국내에서의 가정내 냉장고 온도에 대한 조사를 수행하여, 현 시점에서의 냉장고에서의 식품보관 온도분포를 추정하였고, 이를 MRA(미생물 위해평가: Microbial risk assessment)의 입력변수로 활용할 수 있도록 적정 확률분포 모델을 제시하였다. 일반적으로 가정내 냉장고에서의 식품 보관온도는 식중독 발생 등에서 있어 중요한 위해인자로 작용하는 것으로 알려져 있다. 조사대상 가구는 총 139가구이었으며, 조사기간은 2009년 5월에서부터 9월까지 data logger를 이용하여 측정하였다. 조사된 냉장고 온도의 평균은 $3.53{\pm}2.96^{\circ}C$로, $5^{\circ}C$ 이상은 23.6%로 나타났다. 수집된 온도자료는 @RISK를 이용, 적합성 검정(GOF: K-S와 AD test)을 수행하여 적정 확률분포모델에 대해 추정하였고, 이중 LogLogistic(-10.407, 13.616, 8.6107)분포 모델이 가장 적절한 국내에서의 가정내 냉장고 식품보관 온도분포 모델로 나타났다. 이 확률분포 모델은 MRA적용에 있어 노출평가에서 입력변수로서 직접적 활용이 가능하다고 할 수 있겠다.

IoT 기반 지능형 수위 모니터링 플랫폼 설계 및 구현 (Design and Implementation of IoT-Based Intelligent Platform for Water Level Monitoring)

  • 박지훈;강문성;송정헌;전상민
    • 농촌계획
    • /
    • 제21권4호
    • /
    • pp.177-186
    • /
    • 2015
  • The main objective of this study was to assess the applicability of IoT (Internet of Things)-based flood management under climate change by developing intelligent water level monitoring platform based on IoT. In this study, Arduino Uno was selected as the development board, which is an open-source electronic platform. Arduino Uno was designed to connect the ultrasonic sensor, temperature sensor, and data logger shield for implementing IoT. Arduino IDE (Integrated Development Environment) was selected as the Arduino software and used to develop the intelligent algorithm to measure and calibrate the real-time water level automatically. The intelligent water level monitoring platform consists of water level measurement, temperature calibration, data calibration, stage-discharge relationship, and data logger algorithms. Water level measurement and temperature calibration algorithm corrected the bias inherent in the ultrasonic sensor. Data calibration algorithm analyzed and corrected the outliers during the measurement process. The verification of the intelligent water level measurement algorithm was performed by comparing water levels using the tape and ultrasonic sensor, which was generated by measuring water levels at regular intervals up to the maximum level. The statistics of the slope of the regression line and $R^2$ were 1.00 and 0.99, respectively which were considered acceptable. The error was 0.0575 cm. The verification of data calibration algorithm was performed by analyzing water levels containing all error codes in a time series graph. The intelligent platform developed in this study may contribute to the public IoT service, which is applicable to intelligent flood management under climate change.

부산 - 병전간 해저케이블 전압측정 장치의 개발 (Development of a Voltage Measuring System for the Pusan-Hamada Submarine Cable)

  • Bahk, Kyung-Soo
    • 한국해안해양공학회지
    • /
    • 제3권4호
    • /
    • pp.255-260
    • /
    • 1991
  • 차동증폭과 A/D(analog-to-digital) 변환 회로를 마이크로프로세서(microprocessor)로 작동되는 데이타로거(data logger)에 연결하여 부산-하마다간의 해저케이블 전압변동을 기록하는 장치를 개발하였다. 이 장치는 저가격, 소형, 저전력소모가 특징이며 계기의 전압드리프트(drift)가 정밀수정되고, 무인자동으로 다량의 자료저장과 모뎀(modem)에 의한 자료전달이 가능하다. 케이블 전압 및 전류 이외에 실내온도와 수은전지 전압을 측정하는데, 이는 온도영향에 따른 오차보정과 장기관 계기안정도를 확인하기 위한 것이다. 이 계기에 의한 관측자료에 의하면 부산해저중계국에서의 전압신호는, 약 0.2 볼트의 일정한 폭의 높은 주파수의 잡음대로 이루어져 있는데, 조석과 비슷한 느린 주기로 약 1볼트 범위내에서 변동한다. 또한, 케이블 전원공급장치는 실내온도가 빠르게 변할 때 많은 영향을 받는 것으로 나타났다.

  • PDF

여름철 도시의 일상생활에서 경험하는 환경온도와 온냉감 평가 (24 hours' Exposed Temperature and Thermal Comfort in Summer)

  • 전정윤;이민정
    • 한국주거학회논문집
    • /
    • 제14권3호
    • /
    • pp.51-56
    • /
    • 2003
  • All the outdoor and indoor spaces are connected with each other. The human being moves toward those spaces with temperature fluctuation between the natural and artificial temperature. We conducted an experiment which subjects were wearing the data logger in urban life, and measured 24 hours' exposed temperature and thermal comfort in summer. Results were as follows. 1. Subjects controls their micro climate like this. Most of them(84.6%) get weather information. Fashion(46.2%) and weather(30.8%) are the reasons to select clothes. They spend their time in indoor environment for 84.92% hours of a day and have an air-conditioner(61.5%) in their houses. 2. Temperature fluctuation which subjects were exposed for 24 hours were from 15.6$^{\circ}C$ to 33.8$^{\circ}C$ and average fluctuation was 9.02$^{\circ}C$. The median value of experienced temperature were 26-26.5$^{\circ}C$ and average temperature was 26.18$^{\circ}C$. They experienced cold shock of 3.96 times in a day.

양생직후 초기재령의 콘크리트 내부 온도와 상대습도의 측정 및 분석 (Investigation of Internal Temperature and Relative Humidity of Concrete Immediately After Mix and Placement)

  • 박철우;박영훈;박용걸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1065-1068
    • /
    • 2008
  • Concrete is still one most common construction materials even in railway structures. As structures become massive and mega-sized, the importance of early age concrete quality control becomes more significant. Among various factors, relative humidity and temperature are the primary factors governing the early age quality. Temperature raise due to cement hydration causes stress, which can develop to cracking with internal and/or external restraints. Exposure conditions including ambient temperature, humidity and wind also significantly affect the cracking behavior of early age concrete. Among many of studies on the early age concrete behavior, investigation on the variation of temperature and relative humidity internal of concrete is not common. That is in part because the difficulties in measuring the relative humidity and temperature inside the concrete. This study used a digital sensor with an appropriate logger to measure internal temperature and relative humidity. This direct measuring method is expected to provide more reliable and comprehensive data acquisition on the early age behavior of concrete.

  • PDF

태양열발전용 흡수기 설게 및 열손실 특성실험 (Experimental Study on Heat Losses from Receiver of Solar Thermal Power)

  • 김종규;강용혁;김진수;이상남;유창균;윤환기
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.672-675
    • /
    • 2007
  • Experimental data are presented which describe heat losses of cavity type receiver in wind tunnel. Experiments are conducted at various conditions such as the heater temperature in cavity changes from 300, 400, and 500 oC, wind speed in tunnel from 2 to 8 m/s, and four different tilt angle of 30, 50, 70, 90o. The power consumption including temperature, voltage and current for each experimental conditions are measured and stored in data logger at everyone second interval. The experimental results show that heat losses increase with increasing wind speed and with tilt angle. However, heat losses for the tilt angle of 70 and 90o is almost same at each heater temperature. In addition, the effects of natural convection in combined convection heat losses vary in according to the tilt angle.

  • PDF

여름철 논에서의 기온저감 효과 (The cooling effect of a paddy field area during summer)

  • 송철민;김진수;박종화;정구영
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.1497-1500
    • /
    • 2006
  • The cooling effect of paddy fields was compared with those of other land-use areas (upland, urban park, and urban residential area) during midsummer. The temperature were monitored using data logger at one hour intervals in study sites. Diurnal temperature range of study areas in clear days was larger than in cloudy days. Also, diurnal temperature ranges in paddy field, upland, and park areas were larger than those in the urban residential area during clear days. The paddy field or upland area has shown more remarkable cooling effect compared to urban residential areas: Mean duration of temperature below $25^{\circ}C$ in the paddy field area is longer(7 to 8 hours) than in the residential area; The time to fall to below $25^{\circ}C$ in the paddy field area is sooner than in the residential area; Mean daily minimum temperature in the paddy field area is much lower than in the residential area.

  • PDF