• 제목/요약/키워드: TEMPERATURE

검색결과 89,032건 처리시간 0.081초

MOSFET Rds(on) 온도-저항 특성을 이용한 과열보호회로 모델링 (Over-Temperature Protection Circuit Modeling Using MOSFET Rds(on) Temperature-Resistance Characteristics)

  • 최낙권;이상훈;김형우;김기현;서길수;김남균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 D
    • /
    • pp.3019-3021
    • /
    • 2005
  • In this paper we suggest a novel temperature detection method utilized in direct over-temperature protection circuit modeling. The suggested model detects temperature variation using Rds(on) characteristics of MOSFET, while the conventional methods are using extra devices such as a temperature sensor or an over-temperature detection transistor. The temperature-dependant MOSFET model is implemented using Spice ABM(Spice Analog Behavior Model). The direct over-temperature protection circuit was designed including it. We verified effectiveness of the temperature dependant Rds(on) model characteristics and performance of the direct over-temperature protection circuit on PSpice simulation

  • PDF

광섬유자이로의 고리 온도변화에 의한 바이어스 특성 및 온도 보상 (The Bias Drift Due to Fiber Coil Temperature Variation and the Temperature Compensation in Fiber Optic Gyroscope)

  • 조민식;정경호;도재철;최우석;송기원;강수봉;신원철
    • 한국군사과학기술학회지
    • /
    • 제12권2호
    • /
    • pp.222-227
    • /
    • 2009
  • The bias characteristics due to the changes of temperature and temperature gradient of fiber coil are investigated in fiber-optic gyroscope. The bias performance is degraded with the changes of temperature and temperature gradient of fiber coil. The temperature compensation using both the temperature-dependent bias measurement and the temperature-induced error model of fiber-optic gyroscope improves the bias stability about 3 times as much as the uncompensated original case, which leads to very stable bias performance over the temperature range from $-35^{\circ}C$ to $+77^{\circ}C$.

최상부 유온을 이용한 배전용 변압기의 진단 기법 (A Diagnostic Technique for Distribution Transformers using Top Oil Temperature)

  • 최도혁;윤용한;민경래;김재철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권5호
    • /
    • pp.242-251
    • /
    • 2000
  • In this paper, we argued the possibility of the diagnostic technique for distribution transformers using the top oil temperature rising above the ambient temperature. The proposed diagnostic technique used the reference top oil temperature rising at rated current. We determined the emergency value of the transformer using the limitation of the top oil temperature rising and calculated the loss of life. The top oil temperature rises because of the load currents. In this point, the proposed diagnostic technique was explained. The proposed system measures the load current, top oil temperature and ambient temperature. With the diagnostic device, we tested the top oil temperature rising of t재 transformers. Then the loss of life was calculated by the top oil temperature.

  • PDF

정밀 오일냉각기의 오일온도 제어오차에 관한 연구 (A Study on the Oil Temperature Control Errors of Precision Oil Coolers)

  • 이상호;이찬홍;김갑순
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.451-454
    • /
    • 2003
  • The Oil Coolers is very important unit for the stable thermal performance in machine tools, semiconductor equipments and high precision measuring systems. To select a proper oil cooler for the temperature control of core unit in a machine, not only cooling ability but also static and dynamic sensitivity of temperature sensors are considered. In this paper, the relationship between cooling ability and inflow oil temperature is identified. The cooling ability is increased with the increase of inflow oil temperature. The oil temperature control errors of a cooler are influenced by mainly sensitivity of temperature sensors and heating velocity in a machine. The validity of error cause analysis for temperature control is proved by real cooling experiments with inflow and outflow temperature sensors.

  • PDF

Temperature distribution during heavy oil thermal recovery considering the effect of insulated tubing

  • Zhang, Songting
    • Geomechanics and Engineering
    • /
    • 제19권6호
    • /
    • pp.523-532
    • /
    • 2019
  • Based on the formation characteristics, wellbore parameters and insulated tubing (IT) parameters of the Shengli oilfield, Shandong, China, a geomechanical model is built to predict the temperature distributions of the wellbore and formation. The effects of the IT heat conductivity coefficient (HCC), well depth and IT joint on the temperature distribution of the IT, completion casing, cement sheath, and formation are investigated. Results show the temperature of the formation around the wellbore has an exponentially decreasing relation with the distance to the wellbore. The temperature of the formation around the wellbore has an inverse relation with the IT HCC when the temperatures of the steam and the formation are given. The temperature of the casing outer wall is mainly determined by the steam temperature and IT HCC rather than by the initial formation temperature. The temperature of the casing at the IT joint is much larger than that of the other location. Due to the IT joint having a small size, the effects of the IT joint on the casing temperature distribution are limited to a small area only.

주위온도 변화에 따른 어분의 자연발화에 관한연구 (A Study on Autoignition of Fish Meal with Change of Ambient Temperature)

  • 목연수;최재욱
    • 한국안전학회지
    • /
    • 제7권1호
    • /
    • pp.47-56
    • /
    • 1992
  • Spontaneous ignition charactenstics for fish meal were observed by performing experiments at constant ambient temperature and varying the ambient temperature sinusoidally. As the results of the experiments at a constant ambient temperature, the critical spontaneous ignition temperature of the sample for large, intermediate and small vessels was 170.5$^{\circ}C$, 177.5$^{\circ}C$ and 188.5$^{\circ}C$, respectively. The critical spontaneous ignition temperature decreased as the sample vessel size increased. Apparent activation energy of used fish meal calculated from the Frank-Kamenetskii's thermal ignition theory was 37.60Kcal/mol. In case of varying the ambient temperature sinusoidally, the amplitudes of temperature were 1$0^{\circ}C$, 2$0^{\circ}C$ and 3$0^{\circ}C$ respectively with the period in each amplitude 1hr, 2hrs and 3hrs. The results showed that the critical spontaneous ignition temperatures at the varied amplitudes of temperature were lower than that at the constant anbient temperature and increased as the amplitude increased. At the same amplitude, the critical spontaneous ignition temperature increased with the period.

  • PDF

Correlative Changes between Photosynthetic Activities and Chlorophyll Fluorescence in Wheat Chloroplasts Exposed to High Temperature

  • Young-Nam Hong
    • Journal of Plant Biology
    • /
    • 제37권1호
    • /
    • pp.37-42
    • /
    • 1994
  • Correlative changes between photosynthetic O2 exchange rates and room temperature Chl fluorescence were investigated in wheat (Triticum aestivum L.) chloroplasts treated with high temperature for 5 min. With increasing treatment temperature, photosynthetic O2 evolution rate mediated by PSII was decreased, showing 50% inhibition at 38$^{\circ}C$ (I50). But PSI activity measured by O2 uptake rates was stimulated as a function of increasing temperature. Dark level fluorescence (Fo)-temperature (T) analysis showed that fluorescence rising temperature (Tr), critical temperature (Tc), and peak temperature (Tp) was 38, 43, and 52$^{\circ}C$, respectively. Quenching analysis of Chl fluorescence showed that both the oxidized fraction of plastoquinone (qQ) and degree of thylakoid membrane energization (qNP) increased up to 4$0^{\circ}C$ and then declined dramatically. These results suggest that Tr is correlated with temperature showing a 50% of inhibition of photosynthesis and under mild high temperature stress, qNP is worth regarding as indicator for heat-induced damage of photosynthesis.

  • PDF

Effects of environmental temperature and age on the elastic modulus of concrete

  • Yang, Shuzhen;Liu, Baodong;Li, Yuzhong;Zhang, Minqiang
    • Structural Engineering and Mechanics
    • /
    • 제72권6호
    • /
    • pp.737-746
    • /
    • 2019
  • Concrete mechanical properties change constantly with age, temperature, humidity and the other environmental factors. This research studies the effects of temperature and age on the development of concrete elastic modulus by a series of prism specimens. Elastic modulus test was conducted at various temperatures and ages in the laboratory to examine the effects of temperature and age on it. The experimental results reveal that the concrete elastic modulus decreases with the rise of temperature but increases with age. Then, a temperature coefficient K is proposed to describe the effects of temperature and validated by existing studies. Finally, on the basis of K, analytical models are proposed to determine the elastic modulus of concrete at a given temperature and age. The proposed models can offer designers an approach to obtain more accurate properties of concrete structures through the elastic modulus modification based on actual age and temperature, rather than using a value merely based on laboratory testing.

원자로의 반응도와 온도계수 (Temperature Coefficient of Reactioity)

  • 노윤래
    • 전기의세계
    • /
    • 제15권5호
    • /
    • pp.1-5
    • /
    • 1966
  • The stability and safety of operation of a reactor is determined mainly by the sign and magnitude of its reactivity responses to temperature changes. Reactors are subject to temperature fluctuations due to the changes in reactor power and ambient temperature. These temperature fluctuations cause reactivity disturbances through changes in the nuclear and physical properties of the core. Because of these important phenomena by the temperature effects, a large portion of study and testing on a reactor design has been conducted. In this experiment the overall temperature coefficient of the TRIGA MARK-II reactor is measured. The basic procedure is to change the tgemperature of the water moderator, and from the movements of a newly recalibrated control rod(this is necessary due to the effects of fuel burn-up and control rod depression) required to mintain criticality, the reactivity worth of the temperature change is determined. From this measurement, the overall temperature coefficient seems to be smoothly varying, almost a linear function of temperature, and a value of approximately -0.267${\c}$/$^{\circ}C$ can be obtained for an average temperature range from $17.6^{\circ}C$ to $32.5^{\circ}C$.

  • PDF

Temperature Dependence of Efficiency Droop in GaN-based Blue Light-emitting Diodes from 20 to 80℃

  • Ryu, Guen-Hwan;Seo, Dong-Joo;Ryu, Han-Youl
    • Current Optics and Photonics
    • /
    • 제2권5호
    • /
    • pp.468-473
    • /
    • 2018
  • We investigate the temperature dependence of efficiency droop in InGaN/GaN multiple-quantum-well (MQW) blue light-emitting diodes (LEDs) in the temperature range from 20 to $80^{\circ}C$. When the external quantum efficiency (EQE) and the wall-plug efficiency (WPE) of the LED sample were measured as injection current and temperature varied, the droop of EQE and WPE was found to be reduced with increasing temperature. As the temperature increased from 20 to $80^{\circ}C$, the droop ratio of EQE was decreased from 16% to 14%. This reduction in efficiency droop with temperature can be interpreted by a temperature-dependent carrier distribution in the MQWs. When the carrier distribution and radiative recombination rate in MQWs were simulated and compared for different temperatures, the carrier distribution was found to become increasingly homogeneous as the temperature increased, which is believed to partly contribute to the reduction in efficiency droop with increasing temperature.