• 제목/요약/키워드: TAP device

Search Result 58, Processing Time 0.021 seconds

Smart Multiple-Tap System Based on WiFi for reduction of Standby-Power

  • Jeon, Jeong-woo;Yi, Mira
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.6
    • /
    • pp.123-129
    • /
    • 2017
  • In this paper, we proposed a smart multiple-tap system which a remote user with smartphone can control multiple-taps in order to reduce standby-power consumption more conveniently when plugged-in electric appliances are turned-off. Recently, several researches of smart multiple-tap using IoT technology has reported. However, in these researches, an additional device like as a server computer is necessary, or multiple-taps could be only remotely controlled by smartphone and not directly controlled by on/off switch. The proposed smart multiple-tap system does not need any additional device only if it has a WiFi router, and it can be used for user as well as remote control using smartphone application and physically direct control using contact switches like existing multiple-taps. Our approach is to develop a smart multiple-tap device capable of WiFi communication can each serve as a server or a client, and can be operated by the hybrid switch combining the on/off contact switch and the relay switch. We implemented the prototype of the proposed system composed of the smart multiple-tap device and the smartphone application, and the test of the prototype validates the proposed system.

Development of the Smart Device for Real Time Water Quality Monitoring (실시간 수질 모니터링을 위한 스마트 디바이스의 개발)

  • Ryu, Dae-Hyun;Choi, Tae-Wan
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.4
    • /
    • pp.723-728
    • /
    • 2019
  • Citizens' distrust of water pollution is very high in tap water that we routinely drink. In addition, water pollution accidents of tap water are difficult to predict and the risk is high, so real-time monitoring and management are needed. Therefore, it is necessary to introduce real-time water quality monitoring using the Internet of things(IoT). Residual chlorine is more persistent and economical than other disinfectants and it is easy to check residual effect, so it is mainly used as a disinfection index in waterworks. It can be monitored in real time by using IoT technology in order to secure the safety of tap water. In this study, we developed smart device for real-time water quality monitoring using amperometry sensor and analyzed its performance.

A Study on the Development of One-way Bypass TAP Device for Strengthening the Security of Flood and Environment Surveillance Network (홍수 및 환경 감시망의 보안성 강화를 위한 단방향 Bypass TAP 장치 개발에 관한 연구)

  • Lee, Jin-Young;Kong, Heon-Tag
    • Journal of Digital Convergence
    • /
    • v.13 no.8
    • /
    • pp.473-481
    • /
    • 2015
  • The flood and environment surveillance network on riverside is a network requiring a way to efficiently manage the information from all kinds of sensors, along with an optical communication device that can deliver high-quality video information at high speed. Since on-site prompt recovery is very important especially for communication problems that occurred due to cut-off or aged network, various researches have been carried out on this. However, because the security against outside hacking or outside intrusion with illegal purposes is very important for environment surveillance network, such as the national backbone network, an efficient network maintenance and repair should be enabled while satisfying security and reliability at the same time. A characteristic of requirement is that when security is improved, the efficiency of maintenance and repair drops as they are conflicting to each other. Therefore, this research proposed a system in order to satisfy the conflicting requirement and improve security, by developing a one-way Bypass TAP and an android-based smartphone app that can enable efficient network maintenance and repair.

Impedance design of tap changing auto transformer based LVRT/HVRT test device (탭 변환 단권변압기 기반 LVRT/HVRT 시험장비의 임피던스 설계)

  • Baek, Seung-Hyuk;Kim, Dong-Uk;Yoon, Young-Doo;Kim, Sungmin
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.216-224
    • /
    • 2020
  • This paper proposes an impedance design method of the test device for evaluating Low Voltage Ride Through(LVRT) and High Voltage Ride Through(HVRT) functions. The LVRT/HVRT test device should have ability to generate the fault voltage specified in the grid code for a certain period and to limit the magnitude of the fault current with the design specification. In this paper, the impedance design method for auto transformer is proposed based on a equivalent model of a tap-change auto-transformer during LVRT/HVRT operation. In addition, to generate various fault voltages required the LVRT/HVRT test, tap impedance design in the auto transformer is considered. To verify the validity of the proposed design method, the design process of the 10MVA LVRT/HVRT test device was conducted and the design results was verified through simulation models.

A winding design of Tap Level Converter (Tap Level 제어 전력 변환기의 권선설계)

  • Chun J.H.;Lee H.W.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.53-55
    • /
    • 2006
  • In this paper discusses winding methode of single phase AC-DC reversible power converter The reversible power converter driven by multi Tap winding at both side switching control. It has a advantage that simple drive of main switching device. and obtain load current of good quality without filter circuit and free from noise or isolation for lower switching frequency. In this research, study on current type converter and inverter circuit that consist for possibility of AC-DC/DC-AC multi-level reversible converter.

  • PDF

A Transversal Low Pass Filter Using Charge Coupled Device with Two Level Aluminum Electrode Structure (2중 알루미늄 전극구조의 Charge Coupled Device를 이용한 저역 여파기)

  • 신윤승;김오현
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.18 no.3
    • /
    • pp.25-34
    • /
    • 1981
  • Aluminum anodization method has been investigated for fabricating charge coupled device(CCD) with two-level aluminum gate structure. Al2O3 films were formed to a thickness of 400-500A, by anodizing aluminum with 30-35V of anode voltage for 2 hours using 2 % ammonium tartrate solution as an electrolyte. Breakdown voltage of these films were about 30 volts. Using above mentioned Al2O3 film as an insulator between two aluminum electrodes, CCD transversal low pass filter has been fabricated. CCD transversal low pass filter with 17 tap coefficients has shown 22 dB stop-band attenuation. The operating clock frequency range of the fabricated device was from 3 KHz to 100 KHz.

  • PDF

Optimal Design Study for Development of Washable Faucet Assembly Housing Including Filtration Filter (여과필터를 포함한 세척이 가능한 수도꼭지 어셈블리 하우징 개발을 위한 최적설계 연구)

  • Son, In-Soo;Bae, Sang-Dae
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.5
    • /
    • pp.581-587
    • /
    • 2021
  • In recent years, contamination of drinking water sources has emerged as a serious social problem, such as a large number of impurities in tap water or groundwater or the supply of suitable water due to rust of pipes. Although the government and public institutions are implementing various measures to protect water sources, they cannot improve water quality in a short period of time because of the enormous cost involved. Therefore, in recent years, preference has been given to a device that converts tap water, which is hard water, into soft water by installing a separate water softener at the faucet from which tap water is discharged. However, the existing filtration device has a problem that filtration performance is gradually lowered when impurities accumulate in the filter, requiring continuous filter replacement. In this study, the optimal design of the filter housing was performed to develop a water softener that can be washed when impurities accumulate on the filter inside the water softener connected to the faucet. For optimal design of the filter housing, fluid and fluid-structural interaction analysis were performed on the design pressure to determine the shape and thickness of the housing, and design review was performed through prototype.

Implementation of Smart Multi-tap System based on Zigbee Communication (Zigbee 통신 기반 스마트 멀티탭 시스템 구현)

  • Lee, Jung-Hyuck;Kim, Sang-Hyun;Oh, Chang-Se;Seo, Min-Seok;Kim, Young-Don;Park, Hyun-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.10
    • /
    • pp.930-936
    • /
    • 2014
  • Smart Multiple-Tap to be introduced in this paper, is an electronic device that controls the Multibple-Tap through the Smartphone. It runs on network and has an inbuilt Zigbee communication module. Thus, users can control home devices from remote through home server. Mentioned home server is operated as a gateway and is connected with smart devices on the Internet. To sum up, Users using this Smart Multiple-Tap can check the state information of the multi-tap ON/OFF and can control immediately by smartphone. also, Smart Multiple-Tap perfectly shut down the standby power. when users turn off each of the Smart Multiple-Tap's circle, It drives automatically lowest electricity-consuming mode and shut down the standby power by its own built-in SSR module. therefore, it will bring the energy saving effect on environment using Smart Multiple-Tap.

Empirical study on inhibition effect of scale and rust in tap-water line by zinc ionization device (아연 이온화 장치에 의한 상수배관 내 스케일 및 녹 생성 억제효과 실증 연구)

  • Yum, Kyung-Taek;Choi, Jung-Wook;Yang, Sung-Bong;Shim, Hak-Sup;Yu, Mee-Seon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.6
    • /
    • pp.465-476
    • /
    • 2021
  • Scale and rust generation in water pipes is a common phenomenon when cast iron water pipes have been used for a long time. A physical water treatment device is known among various means for suppressing rust in a water pipe, and a zinc ionization device for putting zinc metal into a pipe and emitting the zinc cation into water is one of such devices. This research measured the amount of zinc ion generated, which is known to exhibit an effect of inhibiting rust and scale generation in a pipe, and examined the scale and rust inhibition effect of the ionization device installed for ground or building water supply. In the case of distilled water, the concentration of zinc ion increased by circulating water in the ionization device several times, and it was verified to be hundreds of ㎍/L, and in the case of discharging ground or tap water, it was verified to be tens of ㎍/L. In addition, a verification pipe was installed to confirm the change inside the pipe before and after installation of the zinc ionization device, and the internal condition of the pipe was observed 3 months to several years after installation. It was confirmed that the corrosion area of the surface of the pipe was no longer increased by installing a corrosion inhibitor, and if the pipe was already filled with corrosion products, the amount of corrosion products gradually decreased every year after installation. The phenomenon of fewer corrosion products could be interpreted as expanding the space in the pipe due to the corrosion product as Fe2O3 adhered to the inner surface of the pipe and turned into a smaller black Fe3O4. In addition, we found that scale such as CaCO3 together in the corrosion by-products gradually decreased with the attachment of the ionization device.

Voltage Sag and Swell Generator with Solid-State Switched Tap Changer (Solid-State Switched Tap Changer를 of용한 Voltage Sag and Swell 발생장치에 대한 연구)

  • Park, Tae-Bum;Chung, Yong-Ho;Kwon, Gi-Hyun;Lim, Kye-Young
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.3-5
    • /
    • 2003
  • 본 논문은 DVR과 DSTATCOM 같은 수 MVA급 용량의 CPD (Custom Power Device)를 평가하기 위한 Sag 및 Swell 전압 발생 장치에 사용될 두 가지 형태의 새로운 회로 방식에 관한 것이다. 제안된 Sag 및 Swell 전압 발생 장치는 계통선로에 직렬로 연결된 직렬 변압기를 통해 다양한 형태로 전압을 발생 시킬 수 있으며, 전격회로는 Solid-State Switched Tap Changer와 AC-Chopper 두 가지 방식을 이용하고 있다. 본 논문에서는 제안된 각각의 방식에 대한 고조파 분석을 하였고, 또한 시뮬레이션을 통해서 제안된 Sag 및 Swell 전압 발생장치를 통해서 원하는 형태의 전압을 얻을 수 있음을 확인하였다.

  • PDF