• Title/Summary/Keyword: TACS

Search Result 33, Processing Time 0.024 seconds

A simulation of Lightning Performance of the 154 kV Transmission Line with the Surge Arrester Installation (154 kV 송전선로에 피뢰기 설치시 내뢰성 향상효과 모의)

  • Shim, Eung-Bo;Woo, Jung-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1642-1644
    • /
    • 1997
  • The simulation study of lightning faults reducing effects by the installation of surge arresters on the 154 kV transmission line is stated here. For the purpose of detailed simulation of arcing horn, a flashover model with dynamic characteristics of arcing horn gap was represented as a non-linear inductance which is controlled by EMTP/TACS(Electromagnetic Transient Program/fransient Analysis of Control Systems) switches. The back flashover inducing current was increased from 50 kA to 88 kA by the installation of surge arresters on the transmission line which has one ground wire and 20 ohms of tower footing resistances. The great advantage of surge arrester installation on one circuit of the double circuit transmission line is to prevent the simultaneous back flashover up to 190 kA.

  • PDF

A Study on Distance Relay Modeling Using EMTP (거리 계전기의 EMTP 모델링에 관한 연구)

  • Shim, Jae-Chul;Ryu, Chang-Won;Kang, Yu-Won;Yim, Wha-Yeong
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.997-999
    • /
    • 1997
  • This Paper presents a relay modeling technique to deal with the relay transient characteristics. Existing relay models are based on steady-state concepts. The ninth-order state space mathematical model of the Mho distance relay has been constructed. Computer modeling of a typical distance relay is done within the Transient Analysis of Control System(TACS) subsection of the ElectroMagnetic Transient Program(EMTP).

  • PDF

Electric Arc furnaces: Chaotic Load Models and Transient Analysis

  • Jang, Gil-Soo;Venkata, S.S.;Kwon, Sae-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.923-925
    • /
    • 1998
  • Electric arc furnaces (EAFs) are a main cause of voltage flicker due to the interaction of the high demand currents of the load with the supply system impedance. The stochastic models have described the physical phenomena of EAFs. An alternative approach is to include deterministic chaos in the characterization of the arc currents. In this paper, a chaotic approach to such modeling is described and justified. At the same time, a DLL (Dynamic Link Library) module, which is a FORTRAN interface with TACS (Transient Analysis of Control Systems), is developed to implement the chaotic load model in the Electromagnetic Transients Program (EMTP). The details of the module and the results of tests performed on the module to verify the model and to illustrate its capabilities are presented in this paper.

  • PDF

A Study on the Implementation of Distance Relaying Techniques using EMTP MODELS (EMTP MODELS를 사용한 거리계전기법 구현에 관한 연구)

  • Lee, Myong-Hee;Choi, Hae-Sul;Seo, Yong-Pil;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.634-636
    • /
    • 1995
  • This paper presents a new distance relay modeling techniques which avoids unnecessary computational procedure. A general-purpose simulation language, called MODELS, has been added to the software ATP(Alternative Transients Program) providing a new option to perform numerical and logical manipulations of variables of an electrical system. This language has been designed to replace the previous option TACS (Transient Analysis of Control Systems) which permits to simulate a control system in conjunction with a large power network. One purpose of this study is to build a structure for modeling of digital distance relays within EMTP MODELS. Contrary to the traditional methods, the new method using MODELS reduce the number of simulation steps in modeling the distance relay.

  • PDF

New Performance Analysis of SSSC with EMPT Simulation and Scaled-model Experiment (EMTP 시뮬레이션과 축소모형 실험에 의한 SSSC의 성능 해석)

  • Kang, Jung-Gu;Han, Byung-Moon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.524-530
    • /
    • 1999
  • This paper describes performance analysis techniques for SSSC using computer simulations with EMPT and experiments with a hardware scaled-model. A switching-level simulation model with EMTP was developed for the SSSC connected in series with the transmission line. The increase of transmission capability and dynamic performance was analyzed with the simulation model. The simulation results were reverified by experimental works with a hardware scaled-model. The developed analysis techniques can be used for designing and evaluating actual system of SSSC.

  • PDF

A study on series compensation capacitors to control subsynchronous resonance (SSR을 제어하기 위한 직렬 보상 캐패시터에 관한 연구)

  • Kim, Sung-Nam;Lee, Seung-Hwan;Lee, Hoon-Goo;Kim, Yong-Joo;Han, Kyung-Hee;Chung, Yon-Tack
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.434-436
    • /
    • 1995
  • This paper was to determine the feasibility of controlling subsynchronous resonance(SSR) by the fast modulation of series compensation capacitors. The presence of subsynchronous currents in the system was detected by a subsynchronous relay which was modeled by the transient analysis of control systems (TACS) in the electromagnetic transients program (EMTP). The capacitor segments were switched by bi-directional thyristor swtiches. The paper proved that effective control of SSR can be obtained only by the detuning of the system and the removal or blocking of subsynchronous energy from the system.

  • PDF

An Analysis on the Overvoltage in Gas Insulated Transmission Lines with EMTP/ATPDraw (EMTP/ATPDraw를 이용한 가스절연송전선로(GIL)의 과전압 분석)

  • Park, Hung-Sok;Han, Sang-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.999-1004
    • /
    • 2011
  • Nowadays, it is becoming difficult to secure a transmission line route when a new transmission line is constructed due to social environment and resident complaints. As existing urban areas are expanded and new cities are constructed, the necessity of high-capacity underground power transmission has been increasing because of load concentration in downtown areas. In North America, Europe and Japan, the research has been carried out for 2nd generation gas insulated transmission lines(GIL) which is more environmentally friendly and economical compared to previous GILs. The new GILs have been applied to real power systems from early 2000s. In South Korea, GIL is being considered as a possible solution for replacing 345kV high-capacity overhead transmission lines with underground transmission ones, so KEPCO is planning to develop and apply a new 362kV rated GIL underground transmission lines instead of overhead transmission lines. In this paper, the overvoltage generated at the combined transmission line adapting GIL was reviewed using EMTP.

A Stock Assessment of Yellow Croaker using Bioeconomic Model: a Case of Single Species and Multiple Fisheries (생물경제모형을 이용한 참조기의 자원평가에 관한 연구 - 단일어종·다수어업 사례를 중심으로)

  • Sim, Seonghyun;Nam, Jongoh
    • Ocean and Polar Research
    • /
    • v.37 no.2
    • /
    • pp.161-177
    • /
    • 2015
  • This study analyzes the stock assessment of yellow croaker caught mainly by the Korean stow net and gill net fisheries focusing on single species and multiple fisheries. This study standardizes fishing efforts for the two fisheries using the general linear model and uses a surplus production model based on the exponential growth model. The Clarke Yoshimoto Pooley model estimates a maximum sustainable yield(MSY), an allowable biological catch(ABC), fishing efforts for MSY($E_{MSY}$) and for ABC($E_{ABC}$). The bio-economic model is used to estimate the maximum economic yield(MEY) and fishing efforts for MEY($E_{MSY}$). Also, the study employs an economic analysis to estimate the economic interaction between stow net and gill net fisheries. The economic analysis shows the profit accruing to the two fisheries from estimated ABC. Finally, the study compares TACs based on single species and single fishery to TAC based on single species and multiple fisheries. The study proposes that the TAC assessment is necessary for single species and multiple fisheries in order to preserve resources.

Development of HIF Detection Rules for Distribution Line (배전선로 보호를 위한 고저항 사고 검출 룰의 개발)

  • Kim, K.H.;Chang, S.I.;Choi, S.K.;Choi, J.H.;Hwang, E.C.;Kim, N.H.;Kang, Y.C.;Park, J.K.;Kim, I.D.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1006-1008
    • /
    • 1997
  • This paper presents the logic based High Impedance Fault(HIF) detection rules for distribution lines. Due to the characteristics of HIF, which shows low current on relaying points, it is difficult to detect the fault occurred in distribution line by the conventional overcurrent relay(OCR) and/or harmonics relay. The HIF data were generated by using TACS in EMTP. In this paper, The harmonic index is defined as the ratio of harmonic component to fundamental component. The proposed HIF detection rules are obtained by analysing the difference between normal condition and HIF condition.

  • PDF

Effectiveness Analysis on Comb Pen Shell Based on TAC System (키조개 TAC 제도의 효과 분석)

  • Jeong, Min-Ju;Nam, Jong-Oh
    • The Journal of Fisheries Business Administration
    • /
    • v.47 no.3
    • /
    • pp.15-33
    • /
    • 2016
  • This study aims to analyze effectiveness of the resource use under the total allowable catch system (TACs) of Comb pen shell, a species among TAC targeting ones through its stock assessment based on the surplus production model such as the Clark Yoshimoto Pooley (CYP) model. Particularly, this study is separated into five analysis periods in order to understand changes in Comb pen shell resource and its efficient use after TAC system implemented in 2001. The results of this study are as follows. First, five sustainable yield curves (SYCs) and exponential growth functions (EGFs) produced by the surplus production model based on Gompertz growth function to compare before and after implementation of the Korean TAC system show that the TAC system has generated a positive stock rebuilding effect for Comb pen shell caught by the diver fishery since 2001. Secondly, five profits based on differences between the sustainable total revenue (STR) and the total cost (TC) with respect to fishing efforts present that the TAC system has increased efficiency of resource use of Comb pen shell caught by the diver fishery after implementation of the Korean TAC system. In conclusion, the Korean TAC system has increased efficiency of resource use as well as has led a positive stock rebuilding effect for Comb pen shell.