• Title/Summary/Keyword: T2WI

Search Result 234, Processing Time 0.034 seconds

Design of a Broadband Window Antenna Using a Parallel T-Matching Network (병렬 T-정합 회로를 이용한 차량 유리 부착형 광대역 안테나 설계)

  • Kim, Yoon-Geon;Kay, Young-Chul;Ji, Sung-Hwan;Choo, Ho-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.1
    • /
    • pp.122-130
    • /
    • 2012
  • In this paper, we propose a broadband vehicle antenna that can operate at the WiBro band(2.3~2.4 GHz) for a wireless internet service. The feeding of the proposed antenna consists of two T-matching networks on both side of the polyarcylate substrate, and the two T-matching networks are connected through via holes. The designed antenna was built and installed on a rear window of a commercial sedan, and the antenna performances, such as the reflection coefficients and the radiation gain are measured in the open-sight area. The received signal strength of the designed antenna was also tested in a strong field area as well as in a weak field area. The measurement results show the matching bandwidth($S_{11}$ <10 dB) of about 300 MHz in the WiBro band and the average gain of about -5.13 dBi along the azimuth direction.

Peritumoral Brain Edema in Meningiomas: Correlation of Radiologic and Pathologic Features

  • Kim, Byung-Won;Kim, Min-Su;Kim, Sang-Woo;Chang, Chul-Hoon;Kim, Oh-Lyong
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.1
    • /
    • pp.26-30
    • /
    • 2011
  • Objective: The primary objective of this study was to perform a retrospective evaluation of the radiological and pathological features influencing the formation of peritumoral brain edema (PTBE) in meningiomas. Methods: The magnetic resonance imaging (MRI) and pathology data for 86 patients with meningiomas, who underwent surgery at our institution between September 2003 and March 2009, were examined. We evaluated predictive factors related to peritumoral edema including gender, tumor volume, shape of tumor margin, presence of arachnoid plane, the signal intensity (SI) of the tumor in T2-weighted image (T2WI), the WHO histological classification (GI, GII/GIII) and the Ki-67 antigen labeling index (LI). The edema-tumor volume ratio was calculated as the edema index (EI) and was used to evaluate peritumoral edema. Results: Gender (p=0.809) and pathological finding (p=0.084) were not statistically significantly associated with peritumoral edema by univariate analysis. Tumor volume was not correlated with the volume of peritumoral edema. By univariate analysis, three radiological features, and one pathological finding, were associated with PTBE of statistical significance: shape of tumor margin (p=0.001), presence of arachnoid plane (p=0.001), high SI of tumor in T2WI (p=0.001), and Ki-67 antigen LI (p=0.049). These results suggest that irregular tumor margins, hyperintensity in T2WI, absence of arachnoid plane on the MRI, and high Ki-67 LI can be important predictive factors that influence the formation of peritumoral edema in meningiomas. By multivariate analysis, only SI of the tumor in T2WI was statistically significantly associated with peritumoral edema. Conclusion: Results of this study indicate that irregular tumor margin, hyperintensity in T2WI, absence of arachnoid plane on the MRI, and high Ki-67 LI may be important predictive factors influencing the formation of peritumoral edema in meningiomas.

Useful MRI Features for Distinguishing Benign Peripheral Nerve Sheath Tumors and Myxoid Tumors in the Musculoskeletal System

  • Lee, Eunchae;Lee, Guen Young;Cho, Whan Sung;Lee, Joon Woo;Ahn, Joong Mo;Lee, Eugene;Kang, Heung Sik
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.3
    • /
    • pp.153-161
    • /
    • 2015
  • Purpose: To identify the differential MRI findings between myxoid tumors and benign peripheral nerve sheath tumors (BPNSTs) in the musculoskeletal system. Materials and Methods: The study participants included a total of 35 consecutive patients who underwent MRI between September 2011 and December 2013. The patients were pathologically diagnosed with myxoid tumors (22 patients) or BPNSTs (13 patients). Evaluation was done by two radiologists, based on the following characteristics: size, margin, degree of signal intensity (SI) on T2-weighted images (T2WI), homogeneity of SI on T2WI, enhancement pattern, enhancement homogeneity, presence of cystic portion, internal fat component, presence of fat split sign, presence of target sign, presence of continuation with adjacent neurovascular bundle, and presence of surrounding halo. Results: Large size, high SI on T2WI, heterogeneous enhancement, and internal fat component were commonly observed in myxoid tumors, while homogenous enhancement, fat split sign, target sign were common in BPNSTs. The differences were statistically significant (P < 0.05). Other findings, such as margin, homogeneity of SI on T2WI, enhancement pattern (peripheral or solid), internal cystic portion, continuation with neurovascular bundle, and surrounding halo, did not show significant difference between myxoid tumors and BPNSTs (P > 0.05). Conclusion: In the differential diagnosis of myxoid tumors and BPNSTs involving the musculoskeletal system, several MRI findings such as degree of SI on T2WI, enhancement homogeneity, internal fat component, fat split sign, and target sign, may be helpful in establishing the diagnosis.

IoT-based D2D relation algorithms utilizing a Wi-Fi (Wi-Fi를 활용한 IoT기반 D2D 릴레이션 알고리즘)

  • Lim, Hyeok;Kim, Wung-Jun;Hwang, Jong-Sun;Jung, Dae-Jin;Jung, Hoe-Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.645-647
    • /
    • 2015
  • IoT (Internet of Things) technology has immense potential in our modern society. Generally when used in a consumer electronics environment, the IoT can continue to work more efficiently than the conventional method of home appliances. In order to use the IOT device's effectively in the environment, we need to determine the relationship between all device's based on their state and priority and compare it to find the suitable device based on the state and priority. In this paper I have done research on Wi-Fi devices in a network environment and I have observed relationships between them. Also I have proposed an algorithm to determine the device status and priority. This determines high-priority devices and they are identified on the basis of the state of the device associated with a particular operation and proceeds further.

  • PDF

Optimizations of 3D MRI Techniques in Brain by Evaluating SENSE Factors (삼차원 자기공명영상법의 뇌 구조 영상을 위한 최적화 연구: 센스인자 변화에 따른 신호변화 평가)

  • Park, Myung-Hwan;Lee, Jin-Wan;Lee, Kang-Won;Ryu, Chang-Woo;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.161-170
    • /
    • 2009
  • Purpose : A parallel imaging method provides us to improve temporal resolution to obtain three-dimensional (3D) MR images. The objective of this study was to optimize three 3D MRI techniques by adjusting 2D SESNE factors of the parallel imaging method in phantom and human brain. Materials and Methods : With a 3 Tesla MRI system and an 8-channel phase-array sensitivity-encoding (SENSE) coil, three 3D MRI techniques of 3D T1-weighted imaging (3D T1WI), 3D T2-weighted imaging (3D T2WI) and 3D fluid attenuated inversion recovery (3D FLAIR) imaging were optimized with adjusting SESNE factors in a water phantom and three human brains. The 2D SENSE factor was applied on the phase-encoding and the slice-encoding directions. Signal-to-noise ratio(SNR), percent signal reduction rate(%R), and contrast-to-noise ratio(CNR) were calculated by using signal intensities obtained in specific regions-of-interest (ROI). Results : In the phantom study, SENSE factor = 3 was provided in 0.2% reduction of signals against without using SENSE with imaging within 5 minutes for 3D T1WI. SENSE factor = 2 was provided in 0.98% signal reduction against without using SENSE with imaging within 5 minutes for 3D T2WI. SENSE factor = 4 was provided in 0.2% signal reduction against without using SENSE with imaging around 6 minutes for 3D FLAIR. In the human brain study, SNR and CNR were higher with SENSE factors = 3 than 4 for all three imaging techniques. Conclusion : This study was performed to optimize 2D SENSE factors in the three 3D MRI techniques that can be scanned in clinical time limitations with minimizing SNR reductions. Without compromising SNR and CNR, the optimum 2D SENSE factors were 3 and 4, yielding the scan time of about 5 to 6 minutes. Further studies are necessary to optimize 3D MRI techniques in other areas in human body.

  • PDF

Functional Magnetic Resonance Imaging in the Diagnosis of Locally Recurrent Prostate Cancer: Are All Pulse Sequences Helpful?

  • Liao, Xiao-Li;Wei, Jun-Bao;Li, Yong-Qiang;Zhong, Jian-Hong;Liao, Cheng-Cheng;Wei, Chang-Yuan
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1110-1118
    • /
    • 2018
  • Objective: To perform a meta-analysis to quantitatively assess functional magnetic resonance imaging (MRI) in the diagnosis of locally recurrent prostate cancer. Materials and Methods: A comprehensive search of the PubMed, Embase, Cochrane Central Register of Controlled Trials, and Cochrane Database of Systematic Reviews was conducted from January 1, 1995 to December 31, 2016. Diagnostic accuracy was quantitatively pooled for all studies by using hierarchical logistic regression modeling, including bivariate modeling and hierarchical summary receiver operating characteristic (HSROC) curves (AUCs). The Z test was used to determine whether adding functional MRI to T2-weighted imaging (T2WI) results in significantly increased diagnostic sensitivity and specificity. Results: Meta-analysis of 13 studies involving 826 patients who underwent radical prostatectomy showed a pooled sensitivity and specificity of 91%, and the AUC was 0.96. Meta-analysis of 7 studies involving 329 patients who underwent radiotherapy showed a pooled sensitivity of 80% and specificity of 81%, and the AUC was 0.88. Meta-analysis of 11 studies reporting 1669 sextant biopsies from patients who underwent radiotherapy showed a pooled sensitivity of 54% and specificity of 91%, and the AUC was 0.85. Sensitivity after radiotherapy was significantly higher when diffusion-weighted MRI data were combined with T2WI than when only T2WI results were used. This was true when meta-analysis was performed on a per-patient basis (p = 0.027) or per sextant biopsy (p = 0.046). A similar result was found when $^1H$-magnetic resonance spectroscopy ($^1H$-MRS) data were combined with T2WI and sextant biopsy was the unit of analysis (p = 0.036). Conclusion: Functional MRI data may not strengthen the ability of T2WI to detect locally recurrent prostate cancer in patients who have undergone radical prostatectomy. By contrast, diffusion-weight MRI and $^1H$-MRS data may improve the sensitivity of T2WI for patients who have undergone radiotherapy.

Individual approach in the recanalization treatment of the acute ischemic brain stroke according to the various MR findings in hyperacute stage

  • Y. Jang;Lee, D.;Kim, H.;Lee, J.;Park, C.G.;Lee, H.K.;Kim, S.;D. Suh
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.98-98
    • /
    • 2003
  • We will present various MR findings of hyperacute ischemic stroke with our own experiences in the management of the patients according to the findings. 대상 및 방법: A total of 441 patients were underwent 'acute stroke MR' imaging protocol between Mar. 2001 and Jun. 2003. The protocol included initial T2-weighted image (WI), diffusion WI (DWI, b=2000), time-of-flight (TOF) MR angiography (MRA), and pefusion WI(PWI), and follow-up T2WI, DWI, TOF MRA, and neck vessel contrast-enhanced MRA obtained three to five days after the insult. Among them, we retrospectively reviewed the MR findings and clinical courses of 193 patients with anterior circulation territorial infarction. Those ICA and MCA lesions were divided into six and five groups respectively according to the level and mechanism of the occlusion. PWI findings can be another factor in the management planning.

  • PDF

Ischemic Infarcion Model by Middle Cerebral Artery Occlusion using Allogenic Blood Clot in Beagle Dogs (비글견에서 동종혈전 색전술을 이용한 중간대뇌동맥의 허혈성 뇌경색 모델)

  • Kim, Younghwan;Choi, Sooyoung;Lee, Kija;Han, Woosok;Choi, Hojung;Lee, Youngwon
    • Journal of Veterinary Clinics
    • /
    • v.33 no.1
    • /
    • pp.10-15
    • /
    • 2016
  • The purpose of this study was to establish reproducible ischemic infarction model using allogenic blood clot in beagle dogs and identify induced ischemic lesion after middle cerebral artery occlusion using magnetic resonance imaging (MRI) and histopathologic findings. Twenty eight male beagle dogs with no evidence of neurologic disease were experimented. Allogenic embolus was made using a healthy beagle dog. After internal carotid artery (ICA) was exposure, 16G catheter was introduced through the ICA. The dog was administered 0.3 ml blood clot for 15 seconds followed by 3 ml of saline for 15 seconds. MRI scans were performed with 1.5T to evaluate ischemic lesion at 7 days after middle cerebral artery occlusion procedure. Evaluation parameters of MRI include location, distribution, infarction type, margin, shape, mass effect and intensity of T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), fluid attenuated inversion recovery (FLAIR) sequence, diffusion weighted imaging (DWI) and apparent diffusion coefficient (ADC). On MRI, all dogs (28/28) showed focal or multifocal lesion including telencephalon and thalamus lesions, especially caudate nucleus (24/28). These lesions had well-defined margin from adjacent brain parenchyma, none or mild mass effect and various shape. Most of dogs appeared hyperintensity on T1WI, T2WI, FLAIR, and DWI/ADC, corresponding to chronic infarction. These lesions were histopathologically confirmed atrophic changes and unstained lesion. In conclusion, MRI is the useful method to provide information about ischemic infarction in dogs and the best reproducible ischemic infarction model was developed by using allogenic blood clot.

Effect of Metals used in Orthopedic on Magnetic Resonance Imaging I (정형보철용 금속이 자기공명영상에 미치는 영향 I)

  • Kim, Hyeong-Gyun;Choi, Seong-Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.46-50
    • /
    • 2012
  • Stainless steel and titanium used for orthopedic prosthetic metal, magnetic resonance imaging was measured quantitatively the extent of distortion. Based on reading tests at varying metal magnetic resonance imaging (MRI) were investigated. To two image acquisition conditions for having three metal bodies mutually quantitative it compared analyzed the image of cross direction and the image of lengthwise. As for the distortion of the magnetic resonance image, as for the distortion of image it became small in the order of Clip, Strainless and Titanium. In addition, with T1WI and T2WI which are image acquisition condition T2WI the distortion of image became small. As for the distortion of the image by the metal, you could see the distortion of image in elliptical shape, the metal a bigger image distortion appeared in many parts. If clinical doctor has the condition of the same operation, use the Titanium material, it can, raising the diagnostic value of magnetic resonance image inspection after the operating from Stainless.

Comparison of Single- and Multi-Echo Susceptibility-Weighted Imaging in Detecting Cerebral Arteriovenous Shunts: A Preliminary Study (뇌동정맥단락 진단에서의 단일 에코 자화율 강조영상과 다중 에코 자화율 강조영상의 비교: 예비 연구)

  • Seung Wan Han;Jae Ho Shin;Yon Kwon Ihn;Seung Ho Yang;Jae Hoon Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.226-239
    • /
    • 2023
  • Purpose To compare the sensitivities of T2-weighted image (T2WI) and susceptibility-weighted imaging (SWI) in detecting cerebral arteriovenous fistula (AVF), cerebral arteriovenous malformation (AVM), and carotid-cavernous sinus fistula (CCF), and to qualitatively evaluate single-echo SWI (s-SWI) and multi-echo SWI (m-SWI) in characterizing vascular lesions. Materials and Methods From January 2016 to December 2021, cerebral angiography-proven lesions were recruited. The sensitivities of T2WI and SWI in detecting vascular lesions were compared using McNemar's test. Qualitative evaluations of s-SWI and m-SWI were categorized to be of poor, average, or good quality and compared using Fisher's exact test. Results A total of 24 patients (mean age: 61 years, 12 female, and 12 male) were enrolled. Twenty patients underwent s-SWI or m-SWI, and four patients underwent both. AVF, AVM, and CCF were diagnosed in 10, 11, and 3 patients, respectively. SWI demonstrated higher sensitivity compared to that of T2WI (82.1% vs. 53.6%, p = 0.013). m-SWI showed better image quality compared to that of s-SWI (good quality, 83.3% vs. 25.0%, p = 0.009). Conclusion SWI demonstrated a higher sensitivity for detecting cerebral arteriovenous shunts compared to that of T2WI. m-SWI exhibited better image quality compared to that of s-SWI in characterizing vascular lesions.