• 제목/요약/키워드: T2 Measurement

검색결과 2,013건 처리시간 0.03초

PV모듈 발전성능 비교시험과 계측편차 요인 분석 (Analysis of Comparison Test and Measurement Error Factor for I - V Performance of Photovoltaic Module)

  • 강기환;김경수;유권종;안형근;한득영
    • 한국태양에너지학회 논문집
    • /
    • 제29권2호
    • /
    • pp.70-75
    • /
    • 2009
  • In this experiment, we did sampling 6 kinds of photovoltaic modules and analyzed the discrepancy of measurement results between l laboratory and 4 PV makers to have performance repeatability at Standard Test Condition(STC) condition. From the KIER's results, Korea's standard test laboratory, other laboratory showed -10% measurement variation. The causes came from correction of reference cell, test condition and the state of skill. Form the comparison test, we analyzed the problems. But three PV maker reduced measurement variation, other one PV maker and one test laboratory didn't improve the problems of correction of reference cell, test condition and the state of skill. Also, High Efficiency Module had a big discrepancy of -10.0$\sim$-6.2% among 3 laboratories which have a less than 10msec light pulse duration time. This made low spectrum response speed so the Fill Factor decreased maximum output power under 10msec light pulse duration time

입원한 영유아의 심첨 맥박 측정 방법에 관한 연구 (The Study for Apical Pulse Measurement Technique Through Hospitalized Children)

  • 조경미;김은주
    • Child Health Nursing Research
    • /
    • 제5권1호
    • /
    • pp.48-58
    • /
    • 1999
  • The purpose of this study was to determine the most accurate technique measuring the apical pulse rate, using three counting duration 15, 30 and 60 seconds, and two methods start ‘0’ and start ‘1’. The instrument used in the study was the EKG monitor, stethoscope and stopwatch. Data was analyzed by utilizing SPSSWIN program. General characteristics of the subjects were analyzed by frequency, percentile, mean, SD. The subject of this research is made up of 46 children and 20 nurses. The children were infants, & under the age of 5. They were hospitalised in PICU & NICU in 2 tertiary hospitals in seoul from Jan. 1. 1998 to Sep. 10. 1998. The measurement of starting 1 & measurement of starting ‘0’ used the T-test to find out the measurement error. Apical pulse duration of 15, 30, 60 seconds were used to find out measurement error, the measurement error depend on experience of Nurse were analyzed by using ANOVA. The result of this study are as follows. 1. When comparing the starting poin of apical pulse 0&1, starting with 1 the measurement error is less, but not statiscally significant. 2. When counting the apical pulse by 15, 30,60 sec. ; 60 seconds counting duration was more accurate, but not statistically significant. 3. The mean of measure error ; Group under 100/min, is 10.33 ; from 100 re 119/min, is 8.30 ; from 120 to 139/min, is 4.76 ; from 140 to 159/min, is 6.09 ; above 160, is 17.83. The differences of these groups are statistically significant. When 60sec were counted, under 140/min the mean of measurement error is 3.4. Also when 30 seconds were counted from 140/min to 159/min the measurement error is 7.14, above 160/min the measurement error is 16.4. That measurement mean is the smallest than the other durations. During the 15 sec. count the measurement error was the largest of them all. 4. By the experience of the nurses, the apical pulse count measurement error was discovered. Under a year experience this measurement error was the largest(11.09), 1 year to under 3 years, the error is the smallest(4.86). 3 year to under 6 years the error is 8.33, 5 years above the error is 6.11 but this is not statistical significant. Under a year experience when counting 15, 30, 60 seconds the error is the largest. The group of the nurses from a year to under 3 years, the measurement error is the smallest of all the groups. The result of the study is to determine the technique measuring the apical pulse rate, Hargest (1974), starting point ‘0’ is not proved. When the pulse rate increases the 30 sec measurement rate is accurate. Under 140/min the 60 sec measurement rate is the most accurate. Depending on the nurses experiences, there is a variable difference to the apical pulse rate measurement. Especially new nurses training courses should enforce the children’s pulse rate count and the basic vital signs.

  • PDF

열처리에 따른 경질 폴리우레탄의 물성 변화 연구 (Studies of Annealing Effect on the Properties of the Rigid Polyurethane)

  • 강성중;정현철;김우년;이영범;최건형;홍성호;김상범
    • 한국가스학회지
    • /
    • 제2권4호
    • /
    • pp.18-24
    • /
    • 1998
  • 작용기가 2.9인 4,4'-diphenylmethane diisocyanate (MDI)와 polyester polyol 그리고 사슬 연장제로서 1,4-butane diol로부터 제조한 polyurethane을 시차 주사 열분석기(DSC) 동적 기계적 열분석기(DMTA), 그리고 퓨리에 변환 적외선 분광기(FT-IR)를 이용하여 물성을 연구하였다. 본 연구에서 제조한 polyurethane은 MDI의 높은 작용기로 인한 가교 때문에 균일한 망상구조를 가지고 있음을 알 수 있었다. 또한 하드 세그먼트 함량이 증가할수록 $T_g$는 증가함을 관찰할 수 있었다. 이러한 DSC 결과는 DMTA에서도 재확인할 수 있었다. 한편 polyurethane의 열처리 효과(annealing effect)를 관찰하기 위해 다양한 열처리 조건에 따라 polyurethane의 열분석을 하였다. 그 결과 열처리 온도가 증가될수록 폴리우레탄의 $T_g$가 증가됨을 관찰할 수 있었다. 반면에 열처리 시간에는 크게 의존하지 않음을 관찰할 수 있었다. 이러한 $T_g$의 증가는 팽윤(swelling) 실험으로부터 열처리에 따라 가교 밀도가 증가하며 이러한 가교 밀도의 증가가 polyurethane의 $T_g$를 상승시키는 원인임을 확인 할 수 있었다. 반면에 FT-IR 연구로부터 열처리에 의한 polyurethane의 수소결합 정도의 변화는 관찰할 수 없었다.

  • PDF

유방촬영용 X선장치의 선질 특성 (Measurement of X-ray Quality in Mammography Unit)

  • 이인자;김정민;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권2호
    • /
    • pp.5-10
    • /
    • 1998
  • In the mammography, X-ray beam quality is one of the most important factors. Using X-ray mammography unit model GE/CGR Senography 600T Senix H.F, Authors studied four subjects. 1. The aluminum attenuation rate in 30 kVp when used with or without compression plate. 2. HVLs at 5 different area of the X-ray field of $26{\sim}32kVp$. 3. HVLs to know the influence of corrected measurement or parallel measurement. 4. Film density with microdensitometer along and cross to the long axis of X-ray tube, in terms of the Heel effect in the X-ray field. The following results were obtained. 1. Beam quality of anode area was harder than cathode area. 2. The dose reduction rate of compression plate was approximately $65.5%{\sim}88.1%$ and the beam quality with compression plate was hardened up to 4kVp accordingly. 3. If the X-ray beam enters the attenuation plate obliquely, HVL was $2.6{\sim}2.9%$ harder than perpendicular to it. 4. Because of heel effect, the film density of cathode area is higher than anode area to film density of 0.5.

  • PDF

장갑의 적합성 향상을 위한 손부위 2차원 계측정보 DB구축에 관한 연구 -성인 남.녀 만 18세에서 만 64세를 중심으로- (The Database Development of 2-D Hands Measurement for Improving Fitness of gloves -focused on the ages from 18 to 64 of male & female adults-)

  • 최혜선;김은경
    • 한국의류학회지
    • /
    • 제28권3_4호
    • /
    • pp.509-520
    • /
    • 2004
  • The aim of this study was to provide the basic 2-dimensional statistics requisite in the siting system and design of gloves. The 64 static measurements were selected to provide information about hands. Participants in the study were 824 adults, aged between 18 and 64. Subjects were divided into four age groups: 18 to 29, 30 to 39, 40 to 49, and 50 to 64, and separated according to sex. Statistical tests such as Descriptive Analysis, and Anova were conducted to analyze the data and ascertain the differences among the ages. The disparities between sex groups were compared by T-test. In addition, correlation among the 57 measurements was analyzed and the results were compared to the data from Japanese and other studies. The results indicated that all the measurements were significantly larger in the male group. There were significant differences among age groups for most hand circumferences, breadths and thickness items. As the age increased, the hand circumferences, breadths and thickness items became wider and thicker. In addition, as the age increased, the mean measurement value of the length items decreased, so that it became shorter. Hand length was highly correlated with finger length, palm length and height. Maximum hand circumference II was highly correlated with hand circumferences, hand breadth and weight.

전실정보 가이드북을 이용한 교육이 신경외과 중환자실 환자가족의 전실스트레스, 불안 및 교육만족도에 미치는 효과 (The Effects of Education Using a Relocation Information Guidebook on Relocation Stress, Anxiety, and Education Satisfaction in Family Caregivers of Patients in Neurosurgical Intensive Care Units)

  • 이현주;이윤미
    • 중환자간호학회지
    • /
    • 제8권2호
    • /
    • pp.43-54
    • /
    • 2015
  • Purpose: This study aimed to identify the effects of education, using a relocation information guidebook, on the family caregivers of patients who were scheduled to be transferred from a neurosurgical intensive care unit to a general ward. Methods: They were divided into two groups: an experimental group (n = 21) and a control group (n = 20). A relocation information guidebook was created based on a literature review and an interview with five family caregivers about how to satisfy their needs. The collected data were analyzed with a ${\chi}^2$ test, Fisher's exact test, paired t-test, and t-test. Results: The effect of education, using the relocation information guidebook, on the family caregivers of patients who were relocated to a general ward from the neurosurgical intensive care unit was not significant for relocation stress (t = 0.94p, = .352) or anxiety (t = 1.25, p = .217), but was significant for education satisfaction (t = -2.50, p = .017). Conclusion: There were no differences in relocation stress and anxiety scores between the control and experimental groups. However, several methodological issues were highlighted that must be considered in future research, including the timing and measurement of transfer anxiety, and the intervention itself.

Breast Cancer Association with CYP1A2 Activity and Gene Polymorphisms - a Preliminary Case-control Study in Tunisia

  • Ayari, I;Arnaud, MJ;Mani, A;Pavanello, S;Saguem, S
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권8호
    • /
    • pp.3559-3563
    • /
    • 2015
  • The aim of the present study was to evaluate the relative contribution of CYP1A2 isoforms (-3860 G/A, -2467T/delT and -163C/A) in control subjects and breast cancer patients to the metabolism of caffeine in human liver. Restriction fragment length polymorphism analysis of PCR-amplified Fragments (PCR-RFLP) was used for the genotyping of CYP1A2 SNPs and HPLC allowed the phenotyping through the measurement of CYP1A2 activity using the 17X + 13X + 37X/137X urinary metabolite ratio (CMR) and plasma caffeine half life (T1/2). The CYP1A2 -3860A genotype was associated with a decreased risk of breast cancer. In contrast, distributions of the CYP1A2 -2467T/delT or -2467delT/delT and -163A/C or A/A genotypes among breast cancer patients and controls were similar. When the genotype and phenotype relationship was measured by comparing the mean CMR ratios and caffeine half life within the genotype groups between subjects and breast cancer patients, there were no significant differences except for -3860 A, most of them being homozygous for the -3860 G/G SNP and had a significant higher mean CMR ratio and half life than those with -3860 G/A (P=0.02). The results of this preliminary study show a significant association between CP1A2 -3860 G variant and CYP1A2 phenotype which must be confirmed by further large-size case-control studies.

EMF 방법에 의한 $BaCuO_2$의 생성자유에너지 측정 (Measurement of Formation Free Energy of $BaCuO_2$ by EMF Method)

  • 김수권
    • 한국재료학회지
    • /
    • 제6권2호
    • /
    • pp.228-234
    • /
    • 1996
  • BzCuO2 의 생성 자유에너지를 이중 이온교환된 Ba2+-$\beta$/$\beta$"-AI2O3를 전해질로 사용하여 다음과 같은 생성셀로부터 측정하였다. Au(po2=10-3)/Au+BaCuO2+CuO// Ba2+-$\beta$/$\beta$"-Au이 갈바닉셀에서 BzCuO2 의 임의의 생성식과 생성자유에너지는 다음과 같다. BaO+CuO=BaCuO2 $\Delta$fGo/kJ.mol-1=-77.3-3.3x10-3T/K.3x10-3T/K.

  • PDF

70 nm T-게이트를 갖는 InGaAs/InAlAs/GaAs metamorphic HEMT 소자의 제작 및 특성 (Fabrication and Characterization of 70 nm T-gate AlGaAs/InGaAs/GaAs metamorphic HEMT Device)

  • 김성찬;임병옥;백태종;고백석;신동훈;이진구
    • 대한전자공학회논문지SD
    • /
    • 제41권9호
    • /
    • pp.19-24
    • /
    • 2004
  • 우리는 3층 구조의 레지스터와 이중 노광 방법을 이용하여 유전체 지지대를 사용하지 않은 새로운 방법으로 게이트 길이가 70 nm인 T-게이트를 갖는 InGaAs/InAlAs/GaAs metamorphic HEMT 제작 하였다. 게이트 길이가 70 nm이고 게이트 단위폭이 70 ㎛인 2개의 게이트를 가지고 있는 MHEMT는 최대 포화 전류밀도가 최대 포화 전류밀도가 228.6 mA/mm, 상호전달 컨덕턴스는 645 mS/mm, 전류이득차단주파수가 255 GHz인 특성을 보였다.

New UWB BPF with Steep Selectivity Based on T-Resonator and Capacitively Coupled λ/4 and λ/2 Line Sections

  • Duong, Thai Hoa;Kim, Ihn-Seok
    • Journal of electromagnetic engineering and science
    • /
    • 제9권3호
    • /
    • pp.164-173
    • /
    • 2009
  • In this paper, two new circuit structures for European and U.S. ultra-wide band(UWB) bandpass filters(BPFs) with sharp roll-off characteristics are introduced. We show first that the ultra-wide bandpass property is obtained from a $\lambda$/4 open T resonator with a capacitively coupled $\lambda$/4 short-circuited line, which provides two attenuation poles at lower and upper cutoff frequencies. Then, two identical capacitively coupled input/output lines, which can be $\lambda$/4-length open ends or $\lambda$/2-length short ends, with the T-resonator, are adopted to suppress lower and higher frequency components outside of the pass band. There is coupling between the input and output lines providing two additional transmission zeros in the lower and upper transition bands of the filter. Since the coupling between the T-resonator with the $\lambda$/4 short-circuited line and the input/output lines limits the bandwidth of the filter to the European UWB band, both the $\lambda$/4 short-circuited line and the input/output lines are inserted between the two stacked T-resonators for the U.S. UWB band. The filter structures are simulated with ADS and HFSS and realized with low-temperature co-fired ceramic(LTCC) green tape which has the dielectric constant of 7.8. Measurement results agree well with HFSS simulation results.