• 제목/요약/키워드: T1 3D subtraction

검색결과 9건 처리시간 0.026초

Comparison of 3D Volumetric Subtraction Technique and 2D Dynamic Contrast Enhancement Technique in the Evaluation of Contrast Enhancement for Diagnosing Cushing's Disease

  • Park, Yae Won;Kim, Ha Yan;Lee, Ho-Joon;Kim, Se Hoon;Kim, Sun-Ho;Ahn, Sung Soo;Kim, Jinna;Lee, Seung-Koo
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권2호
    • /
    • pp.102-109
    • /
    • 2018
  • Purpose: The purpose of this study is to compare the performance of the T1 3D subtraction technique and the conventional 2D dynamic contrast enhancement (DCE) technique in diagnosing Cushing's disease. Materials and Methods: Twelve patients with clinically and biochemically proven Cushing's disease were included in the study. In addition, 23 patients with a Rathke's cleft cyst (RCC) diagnosed on an MRI with normal pituitary hormone levels were included as a control, to prevent non-blinded positive results. Postcontrast T1 3D fast spin echo (FSE) images were acquired after DCE images in 3T MRI and image subtraction of pre- and postcontrast T1 3D FSE images were performed. Inter-observer agreement, interpretation time, multiobserver receiver operating characteristic (ROC), and net benefit analyses were performed to compare 2D DCE and T1 3D subtraction techniques. Results: Inter-observer agreement for a visual scale of contrast enhancement was poor in DCE (${\kappa}=0.57$) and good in T1 3D subtraction images (${\kappa}=0.75$). The time taken for determining contrast-enhancement in pituitary lesions was significantly shorter in the T1 3D subtraction images compared to the DCE sequence (P < 0.05). ROC values demonstrated increased reader confidence range with T1 3D subtraction images (95% confidence interval [CI]: 0.94-1.00) compared with DCE (95% CI: 0.70-0.92) (P < 0.01). The net benefit effect of T1 3D subtraction images over DCE was 0.34 (95% CI: 0.12-0.56). For Cushing's disease, both reviewers misclassified one case as a nonenhancing lesion on the DCE images, while no cases were misclassified on T1 3D subtraction images. Conclusion: The T1 3D subtraction technique shows superior performance for determining the presence of enhancement on pituitary lesions compared with conventional DCE techniques, which may aid in diagnosing Cushing's disease.

유방자기공명영상에서 3 차원 최대 강도 투사 재건 영상의 유용성 (Usefulness of Three-Dimensional Maximal Intensity Projection (MIP) Reconstruction Image in Breast MRI)

  • 김현성;강봉주;김성헌;최재정;이지혜
    • Investigative Magnetic Resonance Imaging
    • /
    • 제13권2호
    • /
    • pp.183-189
    • /
    • 2009
  • 목적 : 유방자기공명영상에서 3 차원 최대 강도 투사 (3D MIP) 재건 영상의 유용성을 알아보고자 하였다. 대상 및 방법 : 유방암으로 진단받고 유방자기공명영상을 시행한 27명의 환자의 54개의 유방을 대상으로 하였다. GE Signa Excite Twin speed (GE medical system, Wisconsin, USA) 1.5 T 기기를 이용하여 기본 영상으로 축면 T2 강조 T1 강조 영상과 시상면 T1 강조 지방 억제 영상, 역동적 조영 증강 영상과 감산 영상을 얻었다. 이후 초기 역동적 조영증강 영상의 감산영상으로 워크스테이견 (GE Medical system)을 이용하여 3D MIP 영상을 얻었다. 3D MIP 영상과 기본 유방자기공명영상에서 발견된 병변을 ACR BI-$RADS^{(R)}$ MRI lexicon에 따라 분석하였다. 각각의 영상에서 발견된 병변의 소견들을 비교하고 3D MIP에서 기본자기공명영상에서 보다 추가적인 정보를 얻을 수 있는지 알아보았다. 결과 : 종괴의 경우 기본 유방자기공명영상에서 보이는 56개 중 43개가 3D MIP 영상에서 발견되었다 (76.8%). 비종괴성 조영 증강의 경우 20개 중 17개가 발견되었다 (85%). 169개의 초점성 조영증강 병변이 3D MIP 영상에서, 109개가 기본 유방자기공명영상에서 확인되었다. 3D MIP 영상에서 60.9%의 category 3병변이 발견되었고(14/23), 68.87%의 category 4 병변 (11/16), 100%의 category 5병변 (28/28)이 발견되었다. 3D MIP 영상에서 분석된 조영증강 병변들의 category가 기본 유방 자기공명 영상의 결과들과 통계적으로 일치하였다(p-value < 0.0001). 기본 유방 자기공명 영상에서 초점으로 분석된 2개의 병변들이 3D MIP 영상에서는 다초점성의 악성 병변으로 발견되었고, 1개의 추가적 병변이 3D MIP 영상에서만 발견되었다. 결론 : 3D MIP 영상은 한계점들을 갖고 있으나, 기본 유방자기공명영상의 분석에 있어 추가적으로 이용 시 유용하다.

  • PDF

Diagnosis of Subclavian Steal: Contrast Enhanced 3D MR Angiography vs 2D TOF

  • 이호규;김건언;최중곤;서대철
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.136-136
    • /
    • 2001
  • Purpose: Subclavian steal refers to the retrograde flow of blood in a vertebral artery that supplies t ipsilateral shoulder and arm caused by proximal subclavian artery stenosis or occlusion. T purpose of this exhibit is to demonstrate MR findings of subclavian steal on contrast-enhanc 3D (CE 3DMRA) and 2D TOF MR angiography. Method: Four patients(men 3 and women 1, age: 28-78years) with subclavian steal obtained both CE 3DMRA and digital subtraction angiography(DSA) including subclavian arterie Sequential imaging was undertaken during first pass after double dose of Gd-DTPA (0 mM/kg) Injected by a power injector. Coronal source images were obtained with coronal D-fast low angle shot sequence(TR/TE/flip angle=3.8/l.3/35, acquisition time= 10sec/one measurement). Precontrast imaging was subtracted from enhanced images and maximu intensity projection was done. 2D time-of-flight MR angiography(2D TOF) of the carot bifurcation was added in all cases with post-saturation. All studies were review retrospectively.

  • PDF

Comparison of Ictal-Interictal Subtraction and Statistical Parametric Mapping in Patients with Temporal Lobe Epilepsy

  • Rahyeong Juh;Taesuk Suh;Kim, Jaeseung;Daehyuk Moon
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.335-337
    • /
    • 2002
  • The aim of this study was investigate the epileptogenic zone in temporal lobe epilepsy (TLE). We evaluated the subtraction image of interictal SPECT from ictal SPECT coregistered to 3-dimensional (3D) MRI, and compared with the normal healthy SPECT using a SPM99. Forty-nine patients with TLE (M:F=28:21, mean age: 33${\pm}$2.1 years) underwent a pairs of ictal and interictal SPECT. We performed subtraction interictal SPECT from ictal SPECT in TLE patients. In addition, using SPM methods and t-statistics, SPECT images of the TLE patients were compared with normal healthy SPECT on a voxel by voxel basis. The voxels with a p-value of less than 0.05, 0.005, 0.001 were considered to be significantly different. The subtraction results by ictal and interictal SPECT coincided with the significant rCBF changes when compare of the normal healthy SPECT using a SPM99. The results suggested that analysis of difference of the two methods using healthy normal SPECT with SPM99 is useful tool in evaluation of seizure focus in epilepsy.

  • PDF

The Utility Evaluation of Reconstructed 3-D Images by Maximum Intensity Projection in Magnetic Resonance Mammography and Cholangiopancreatography

  • Cho, Jae-Hwan;Lee, Hae-Kag;Park, Cheol-Soo;Kim, Ham-Gyum;Baek, Jong-Geun;Kim, Eng-Chan
    • Journal of Magnetics
    • /
    • 제19권4호
    • /
    • pp.365-371
    • /
    • 2014
  • The aim of this study was to evaluate the utility of 3-D images by comparing and analyzing reconstructed 3-D images from fast spin echo images of MRI cholangiopancreatography (MRCP) images using maximum intensity projection (MIP) with the subtraction images derived from dynamic tests of magnetic resonance mammography. The study targeted 20 patients histologically diagnosed with pancreaticobiliary duct disease and 20 patients showing pancreaticobiliary duct diseases, where dynamic breast MR (magnetic resonance) images, fast spin echo imaged of pancreaticobiliary duct, and 3-D reconstitution images using a 1.5T MR scanner and 3.0T MR scanner were taken. As a result of the study, the signal-to-noise ratio in the subtracted breast image before and after administering the contrast agent and in the reconstructed 3-D breast image showed a high ratio in the reconstructed image of lesional tissue, relevant tissue, and fat tissue. However, no statistically meaningful differences were found in the contrast-to-noise ratio of the two images. In the case of the MRCP image, no differences were found in the ratios of the fast spin echo image and reconstructed 3-D image.

The Role of Dynamic Contrast Enhanced MR Mammography in Differentiation between Benign and Malignant Breast Lesions

  • 한송이;차은숙;정상설;김학희;변재영;이재문
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.135-135
    • /
    • 2002
  • Purpose: To assess diagnostic accuracy of dynamic contrast enhanced MR mammography in differentiating between benign and malignant lesions. Materials and methods: Ninety-three patients with suspicious mammographic, sonographic or palpable findings underwent pre- or postoperative contrast-enhanced MR imaging of breast using three dimensional fast low-angle shot (3D FLASH) sequence (16/4 msec[repetition time / echo time], 20 flip angle, 3mm slice thickness with no slice gap, 256 by 256 in-plane matrix) covering whole breasts. T1 weighted images were obtained before and after bolus administration of gadopentetate dimeglumine (0.15 mmol/kg). Subtraction images and time-signal intensity curves of region of interest were obtained sequentially and correlated with pathologic diagnoses of lesions.

  • PDF

Subtraction 기법을 이용한 한우 성장 단계 특이 발현 유전자 탐색 (Identification of the Differentially Expressed Genes of Hanwoo During the Growth Stage by Subtractive cDNA Hybridization)

  • 장요순;김태헌;윤두학;박응우;정일정;조진기
    • Journal of Animal Science and Technology
    • /
    • 제44권1호
    • /
    • pp.13-22
    • /
    • 2002
  • 한우의 성장단계 특이발현 유전자를 탐색하기 위하여, 본 연구에서는 유전자의 발현 유무 및 발현정도의 차이를 나타내는 유전자를 분리하는데 있어 가장 강력한 수단으로 알려진 subtractive cDNA hybridization 기법을 이용하여 한우 등심조직으로부터 12개월령 및 24개월령 특이적인 subtractive cDNA library를 제작하였다. 성장단계 특이적인 유전자를 탐색하기 위하여, 6, 12 및 24개월령 cDNA를 사용하여 reverse northern blot 분석을 실시하였으며, 6개월령 cDNA probe에 대하여 특이적인 signal을 나타낸 3개의 clone은 EPV 20, Ca2+ ATPase, 및 TCTP 유전자와 유사성을 나타내었다. 12개월령 cDNA probe에 대하여 특이적인 signal을 나타낸 9개의 cDNA clone은 각각 VCP, HSP 70, aldolase A, MSSK1, GM-2 activator protein, ryanodine receptor, acidic ribosomal phosphoprotein p1, ADP/ATP translocase T1 및 UCP 2 유전자와 높은 homology를 가지고 있었다. 또한 2개의 clone이 각각 12개월령 및 24개월령 cDNA probe에 대하여 특이적인 signal을 나타내었는데, 12개월령 cDNA probe에 대해서만 signal을 나타낸 clone은 ferrochelatase 유전자와 유사하였으며, 24개월령 probe에 대해서만 signal을 나타낸 clone은 ADRP 유전자와 유사하였다. 이상에서와 같이, 본 연구에서 제작한 성장단계 특이적인 subtractive cDNA library를 분석하여 14종의 유전자를 한우 성장단계 특이 발현 후보 유전자로 선정하여 염기서열을 분석하였으며, 이외에도 성장단계에 있어 특이적으로 발현될 것으로 추정되는 cDNA 클론의 염기서열을 분석하였다.

Brain Perfusion SPECT에서 Image Registration의 유용성 (Usefulness of Image Registration in Brain Perfusion SPECT)

  • 송호준;임정진;김진의;김현주
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.60-64
    • /
    • 2011
  • Brain의 질병을 평가하는 유용한 검사방법 중의 하나인 brain perfusion SPECT는 환자의 움직임으로 인한 검사의 실패확률이 높아 one day method를 사용하지 못하고 two days method를 사용해야 하는 경우가 많다. 본 연구에서는 image registration을 사용하여 검사의 실패확률을 줄이고 one day method로 검사를 시행할 수 있는지 image registration을 적용할 경우 검사의 신뢰성을 알아보고자 하였다. Jaszczak phantom에 준비된 방사성동위원소 $^{99m}Tc$을 insert에 111 MBq/mL가 되도록 분배하여 넣고 나머지 background에 3,145 MBq/mL가 되도록 넣어 1:8의 비율로 phantom을 제작하고 Hoffman 2-D brain phantom과 cylindrical uniform phantom에는 111 MBq/mL가 되도록 만든다. 완성된 phantom은 기본 위치에서 frame 당 5 sec씩 총 120 frame을 획득하여 영상을 얻었다. 또 Phantom과 환자의 데이터를 가지고 original 영상과 registration 영상, registration 시행한 후에 original 영상을 subtraction한 영상과 registration하지 않은 영상에서 subtraction한 영상 간의 임의의 같은 위치에 ROI를 설정하고 영상에서 counts 차이를 알아보았다. 실험 결과 약간의 counts 차이를 보였으나 이것은 실험시간이 경과함에 따른 RI의 decay와 phantom의 구조물이 없는 cylindlical phantom에서 조차 약간의 counts의 차이를 보이는 바로 미루어 봤을 때 실험 결과 나온 counts의 차이는 적다고 할 수 있을 것이다. 따라서 registration을 활용하여 brain perfusion SPECT의 단점들을 개선하고 정확한 진단에 도움을 줄 수 있을 것으로 사료된다.

  • PDF

인체 혈장 중 칼시트리올의 효소면역 분석법 검증 및 단회투여 후 약물동태 연구 (Validation of an Enzyme-Immunoassay for Calcitriol in Human Plasma and Evaluation of Its Pharmacokinetics after Single-dose in Korean Volunteers)

  • 김예태;진수언;김현기;신백기;정의현;김종국;박정숙
    • Journal of Pharmaceutical Investigation
    • /
    • 제39권4호
    • /
    • pp.309-314
    • /
    • 2009
  • An enzyme immunoassay (EIA) was validated for quantitation of cacitriol in human plasma. Calcitriol was immunoextracted with immunocapsules, which contain monoclonal antibodies to calcitriol linked to solid phase particles in suspension with a vitamin D binding protein inhibitor. Calcitrol was eluated and the eluates were evaporated under a gentle stream of nitrogen gas. The absorbance of analytes was determined using a microplate reader (reference wavelength 650 nm; measurement wavelength 450 nm). The method was specific and sensitive enough to detect as low as 6.5 pmol/L of calcitriol. Linear calibration range was 6.5-491 pmol/L with correlation coefficient greater than 0.99. The overall accuracy was in the range of 83.8 to 111.2% and precision C.V. (%) 0.99 to 8.47%. The recovery was approximately 100% and stability was confirmed during storage and sample preparation. The pharmacokinetic parameters were calculated by baseline subtraction because calcitriol is an endogenous material. Following oral dose of calcitriol, the mean AUC$_{24h}$ was 1038${\pm}$539 pmol/Lhr and C$_{max}$ of 128${\pm}$63.1 pmol/L was reached at 3.50${\pm}$1.07 hr. The mean t$_{1/2}$ of calcitriol was 5.13${\pm}$2.10 hr. The present EIA method was successfully applied to study bioavailability after oral administration of 2 ${\mu}$g of calcitriol in healthy Korean subjects.