• Title/Summary/Keyword: T1 3D subtraction

Search Result 9, Processing Time 0.032 seconds

Comparison of 3D Volumetric Subtraction Technique and 2D Dynamic Contrast Enhancement Technique in the Evaluation of Contrast Enhancement for Diagnosing Cushing's Disease

  • Park, Yae Won;Kim, Ha Yan;Lee, Ho-Joon;Kim, Se Hoon;Kim, Sun-Ho;Ahn, Sung Soo;Kim, Jinna;Lee, Seung-Koo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.2
    • /
    • pp.102-109
    • /
    • 2018
  • Purpose: The purpose of this study is to compare the performance of the T1 3D subtraction technique and the conventional 2D dynamic contrast enhancement (DCE) technique in diagnosing Cushing's disease. Materials and Methods: Twelve patients with clinically and biochemically proven Cushing's disease were included in the study. In addition, 23 patients with a Rathke's cleft cyst (RCC) diagnosed on an MRI with normal pituitary hormone levels were included as a control, to prevent non-blinded positive results. Postcontrast T1 3D fast spin echo (FSE) images were acquired after DCE images in 3T MRI and image subtraction of pre- and postcontrast T1 3D FSE images were performed. Inter-observer agreement, interpretation time, multiobserver receiver operating characteristic (ROC), and net benefit analyses were performed to compare 2D DCE and T1 3D subtraction techniques. Results: Inter-observer agreement for a visual scale of contrast enhancement was poor in DCE (${\kappa}=0.57$) and good in T1 3D subtraction images (${\kappa}=0.75$). The time taken for determining contrast-enhancement in pituitary lesions was significantly shorter in the T1 3D subtraction images compared to the DCE sequence (P < 0.05). ROC values demonstrated increased reader confidence range with T1 3D subtraction images (95% confidence interval [CI]: 0.94-1.00) compared with DCE (95% CI: 0.70-0.92) (P < 0.01). The net benefit effect of T1 3D subtraction images over DCE was 0.34 (95% CI: 0.12-0.56). For Cushing's disease, both reviewers misclassified one case as a nonenhancing lesion on the DCE images, while no cases were misclassified on T1 3D subtraction images. Conclusion: The T1 3D subtraction technique shows superior performance for determining the presence of enhancement on pituitary lesions compared with conventional DCE techniques, which may aid in diagnosing Cushing's disease.

Usefulness of Three-Dimensional Maximal Intensity Projection (MIP) Reconstruction Image in Breast MRI (유방자기공명영상에서 3 차원 최대 강도 투사 재건 영상의 유용성)

  • Kim, Hyun-Sung;Kang, Bong-Joo;Kim, Sung-Hun;Choi, Jae-Jeong;Lee, Ji-Hye
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.183-189
    • /
    • 2009
  • Purpose : To evaluate the usefulness of three-dimensional (3D) maximal intensity projection (MIP) reconstruction method in breast MRI. Materials and Methods : Total 54 breasts of consecutive 27 patients were examined by breast MRI. Breast MRI was performed using GE Signa Excite Twin speed (GE medical system, Wisconsin, USA) 1.5T. We obtained routine breast MR images including axial T2WI, T1WI, sagittal T1FS, dynamic contrast-enhanced T1FS, and subtraction images. 3D MIP reconstruction images were obtained as follows; subtraction images were obtained using TIPS and early stage of contrast-enhanced TIPS images. And then 3D MIP images were obtained using the subtraction images through advantage workstation (GE Medical system). We detected and analyzed the lesions in the 3D MIP and routine MRI images according to ACR $BIRADS^{(R)}$ MRI lexicon. And then we compared the findings of 3D MIP and those of routine breast MR images and evaluated whether 3D MIP had additional information comparing to routine MR images. Results : 3D MIP images detect the 43 of 56 masses found on routine MR images (76.8%). In non-mass like enhancement, 3D MIP detected 17 of 20 lesions (85 %). And there were one hundred sixty nine foci at 3D MIP images and one hundred nine foci at routine MR images. 3D MIP images detected 14 of 23 category 3 lesions (60.9%), 11 of 16 category 4 lesions (68.87%), 28 of 28 Category 5 lesions (100%). In analyzing the enhancing lesions at 3D MIP images, assessment categories of the lesions were correlated as the results at routine MR images (p-value < 0.0001). 3D MIP detected additional two daughter nodules that were descriped foci at routine MR images and additional one nodule that was not detected at routine MR images. Conclusion : 3D MIP image has some limitations but is useful as additional image of routine breast MR Images.

  • PDF

Diagnosis of Subclavian Steal: Contrast Enhanced 3D MR Angiography vs 2D TOF

  • 이호규;김건언;최중곤;서대철
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.136-136
    • /
    • 2001
  • Purpose: Subclavian steal refers to the retrograde flow of blood in a vertebral artery that supplies t ipsilateral shoulder and arm caused by proximal subclavian artery stenosis or occlusion. T purpose of this exhibit is to demonstrate MR findings of subclavian steal on contrast-enhanc 3D (CE 3DMRA) and 2D TOF MR angiography. Method: Four patients(men 3 and women 1, age: 28-78years) with subclavian steal obtained both CE 3DMRA and digital subtraction angiography(DSA) including subclavian arterie Sequential imaging was undertaken during first pass after double dose of Gd-DTPA (0 mM/kg) Injected by a power injector. Coronal source images were obtained with coronal D-fast low angle shot sequence(TR/TE/flip angle=3.8/l.3/35, acquisition time= 10sec/one measurement). Precontrast imaging was subtracted from enhanced images and maximu intensity projection was done. 2D time-of-flight MR angiography(2D TOF) of the carot bifurcation was added in all cases with post-saturation. All studies were review retrospectively.

  • PDF

Comparison of Ictal-Interictal Subtraction and Statistical Parametric Mapping in Patients with Temporal Lobe Epilepsy

  • Rahyeong Juh;Taesuk Suh;Kim, Jaeseung;Daehyuk Moon
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.335-337
    • /
    • 2002
  • The aim of this study was investigate the epileptogenic zone in temporal lobe epilepsy (TLE). We evaluated the subtraction image of interictal SPECT from ictal SPECT coregistered to 3-dimensional (3D) MRI, and compared with the normal healthy SPECT using a SPM99. Forty-nine patients with TLE (M:F=28:21, mean age: 33${\pm}$2.1 years) underwent a pairs of ictal and interictal SPECT. We performed subtraction interictal SPECT from ictal SPECT in TLE patients. In addition, using SPM methods and t-statistics, SPECT images of the TLE patients were compared with normal healthy SPECT on a voxel by voxel basis. The voxels with a p-value of less than 0.05, 0.005, 0.001 were considered to be significantly different. The subtraction results by ictal and interictal SPECT coincided with the significant rCBF changes when compare of the normal healthy SPECT using a SPM99. The results suggested that analysis of difference of the two methods using healthy normal SPECT with SPM99 is useful tool in evaluation of seizure focus in epilepsy.

  • PDF

The Utility Evaluation of Reconstructed 3-D Images by Maximum Intensity Projection in Magnetic Resonance Mammography and Cholangiopancreatography

  • Cho, Jae-Hwan;Lee, Hae-Kag;Park, Cheol-Soo;Kim, Ham-Gyum;Baek, Jong-Geun;Kim, Eng-Chan
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.365-371
    • /
    • 2014
  • The aim of this study was to evaluate the utility of 3-D images by comparing and analyzing reconstructed 3-D images from fast spin echo images of MRI cholangiopancreatography (MRCP) images using maximum intensity projection (MIP) with the subtraction images derived from dynamic tests of magnetic resonance mammography. The study targeted 20 patients histologically diagnosed with pancreaticobiliary duct disease and 20 patients showing pancreaticobiliary duct diseases, where dynamic breast MR (magnetic resonance) images, fast spin echo imaged of pancreaticobiliary duct, and 3-D reconstitution images using a 1.5T MR scanner and 3.0T MR scanner were taken. As a result of the study, the signal-to-noise ratio in the subtracted breast image before and after administering the contrast agent and in the reconstructed 3-D breast image showed a high ratio in the reconstructed image of lesional tissue, relevant tissue, and fat tissue. However, no statistically meaningful differences were found in the contrast-to-noise ratio of the two images. In the case of the MRCP image, no differences were found in the ratios of the fast spin echo image and reconstructed 3-D image.

The Role of Dynamic Contrast Enhanced MR Mammography in Differentiation between Benign and Malignant Breast Lesions

  • 한송이;차은숙;정상설;김학희;변재영;이재문
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.135-135
    • /
    • 2002
  • Purpose: To assess diagnostic accuracy of dynamic contrast enhanced MR mammography in differentiating between benign and malignant lesions. Materials and methods: Ninety-three patients with suspicious mammographic, sonographic or palpable findings underwent pre- or postoperative contrast-enhanced MR imaging of breast using three dimensional fast low-angle shot (3D FLASH) sequence (16/4 msec[repetition time / echo time], 20 flip angle, 3mm slice thickness with no slice gap, 256 by 256 in-plane matrix) covering whole breasts. T1 weighted images were obtained before and after bolus administration of gadopentetate dimeglumine (0.15 mmol/kg). Subtraction images and time-signal intensity curves of region of interest were obtained sequentially and correlated with pathologic diagnoses of lesions.

  • PDF

Identification of the Differentially Expressed Genes of Hanwoo During the Growth Stage by Subtractive cDNA Hybridization (Subtraction 기법을 이용한 한우 성장 단계 특이 발현 유전자 탐색)

  • Jang, Y.S.;Kim, T.H.;Yoon, D.H.;Park, E.W.;Cheong, I.C.;Jo, J.K.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.1
    • /
    • pp.13-22
    • /
    • 2002
  • To identify the differentially expressed genes at growth stage of Hanwoo, we constructed the subtractive cDNA library from loin mRNA of 12- and 24-month old Hanwoo by PCR-based subtraction. The fourteen genes were confirmed by sequencing and reverse northern blot analysis, and they were selected as candidate of putative genes differentially expressed at the growth stage of Hanwoo. Three subtracted cDNA fragments that expressed specific signal to cDNA probe for 6-month-old loin of Hanwoo were highly homologous to those of the genes encoding EPV 20, Ca2+ATPase, and TCTP, respectively. The nine cDNA clones showed intense signal to cDNA probe from 12-month-old loin of Hanwoo, and highly homologus to those of genes encoding VCP, HSP 70, aldolase A, MSSK1, GM-2 activator protein, ryanodine receptor, acidic ribosomal phosphoprotein p1, ADP/ATP translocase, and UCP 2, respectively. Two subtracted cDNA clones that expressed specific signal to cDNA probes for 12- and 24-month-old loin of Hanwoo were detected. One of them was highly homologus to the gene encoding ferrochelatase and the other was highly homologus to the gene encoding ADRP.

Usefulness of Image Registration in Brain Perfusion SPECT (Brain Perfusion SPECT에서 Image Registration의 유용성)

  • Song, Ho-June;Lim, Jung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.60-64
    • /
    • 2011
  • Purpose: The brain perfusion SPECT is the examination which is able to know adversity information related brain disorder. But brain perfusion SPECT has also high failure rates by patient's motions. In this case, we have to use two days method and patients put up with many disadvantages. We think that we don't use two days method in brain perfusion SPECT, if we can use registration method. So this study has led to look over registration method applications in brain perfusion SPECT. Materials and Methods: Jaszczak, Hoffman and cylindrical phantoms were used for acquiring SPECT image data on varying degree in x, y, z axes. The phantoms were filled with $^{99m}Tc$ solution that consisted of a radioactive concentration of 111 MBq/mL. Phantom images were acquired through scanning for 5 sec long per frame by using Triad XLT9 triple head gamma camera (TRIONIX, USA). We painted the ROI of registration image in brain data. So we calculated the ROIratio which was different original image counts and registration image counts. Results: When carring out the experiments under the same condition, total counts differential was from 3.5% to 5.7% (mean counts was from 3.4% to 6.8%) in phantom and patients data. In addition, we also run the experiments in the double activity condition. Total counts differential was from 2.6% to 4.9% (mean counts was from 4.1% to 4.9%) in phantom and patients data. Conclusion: We can know that original and registration data are little different in image analysis. If we use the image registration method, we can improve disadvantage of two days method in brain perfusion SPECT. But we must consider image registration about the distance differences in x, y, z axes.

  • PDF

Validation of an Enzyme-Immunoassay for Calcitriol in Human Plasma and Evaluation of Its Pharmacokinetics after Single-dose in Korean Volunteers (인체 혈장 중 칼시트리올의 효소면역 분석법 검증 및 단회투여 후 약물동태 연구)

  • Kim, Ye-Tae;Jin, Su-Eon;Kim, Hyun-Ki;Shin, Baek-Ki;Jeong, Ui-Hyeon;Kim, Chong-Kook;Park, Jeong-Sook
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.4
    • /
    • pp.309-314
    • /
    • 2009
  • An enzyme immunoassay (EIA) was validated for quantitation of cacitriol in human plasma. Calcitriol was immunoextracted with immunocapsules, which contain monoclonal antibodies to calcitriol linked to solid phase particles in suspension with a vitamin D binding protein inhibitor. Calcitrol was eluated and the eluates were evaporated under a gentle stream of nitrogen gas. The absorbance of analytes was determined using a microplate reader (reference wavelength 650 nm; measurement wavelength 450 nm). The method was specific and sensitive enough to detect as low as 6.5 pmol/L of calcitriol. Linear calibration range was 6.5-491 pmol/L with correlation coefficient greater than 0.99. The overall accuracy was in the range of 83.8 to 111.2% and precision C.V. (%) 0.99 to 8.47%. The recovery was approximately 100% and stability was confirmed during storage and sample preparation. The pharmacokinetic parameters were calculated by baseline subtraction because calcitriol is an endogenous material. Following oral dose of calcitriol, the mean AUC$_{24h}$ was 1038${\pm}$539 pmol/Lhr and C$_{max}$ of 128${\pm}$63.1 pmol/L was reached at 3.50${\pm}$1.07 hr. The mean t$_{1/2}$ of calcitriol was 5.13${\pm}$2.10 hr. The present EIA method was successfully applied to study bioavailability after oral administration of 2 ${\mu}$g of calcitriol in healthy Korean subjects.