• 제목/요약/키워드: T-type plate

검색결과 197건 처리시간 0.024초

Numerical studies on axially loaded doubler plate reinforced elliptical hollow section T-joints

  • Sari, Busra;Ozyurt, Emre
    • Steel and Composite Structures
    • /
    • 제43권1호
    • /
    • pp.107-116
    • /
    • 2022
  • This paper presents results of numerical studies completed on unreinforced and doubler plate reinforced Elliptical Hollow Section (EHS) T-joints subjected to axial compressive loading on the brace member. Non-linear finite element (FE) models were developed using the finite element code, ABAQUS. Available test data in literature was used to validate the FE models. Subsequently, a parametric study was carried out to investigate the effects of various geometrical parameters of main members and reinforcement plates on the ultimate capacity of reinforced EHS T-joints. The parametric study found that the reinforcing plate significantly increases the ultimate capacity of EHS T-joints up to twice the capacity of the corresponding unreinforced joint. The thickness and length of the reinforcing plate have a positive effect on the ultimate capacity of Type 1 joints. This study, however, found that the capacity of Type 1 orientation is not dependent on the brace-to-chord diameter ratio. As for type 2 orientations, the thickness and length of the reinforcement have a minimal effect on the ultimate capacity. A new design method is introduced to predict the capacity of the reinforced EHS T-joints Type 1 and 2 based on the multiple linear regression analyses.

The Image Resolution Compare to Having Lead Plate or Not Lumbar Lateral Projection

  • Kim, Hyun-Soo;Min, Jung-Whan;Dong, Kyung-Rae
    • 대한디지털의료영상학회논문지
    • /
    • 제13권4호
    • /
    • pp.145-151
    • /
    • 2011
  • The purpose of this study is to know some changes of resolution and image if we remove scattered ray using lead plate when doing lumbar lateral projection. Using 3 DR system(2 FD types, 1 CCD type) equipments and 2 film system equipments, we gain the image whether the phantom of abdomen equivalent sticking resolution chart has lead plate or not, whether we do collimation or not. Also, we use ion chamber, measure radiation exposure rate and change to entrance surface dose from it. we gain that images in the greatest condition of taking in clinic. 5 people in this group decoded resolution with our eyes, measured thickness of images and compared them from each equiments. Resolution has difference to size of collimation in DR FD type. Also there is no difference the original image with the new image which we abbreviated mAs. In DR CCD type, resolution didn't have difference whether lead plate is or not and whether we do collimation or not. In film type, existing or nonexisting of lead plate didn't influence on resolution. Lead plate makes the quality of image higher due to reducing scattered ray, it doesn't influence on resolution.

  • PDF

철근콘크리트 기둥 철골 보의 합성구조 외부형 접합부 구조성능에 관한 연구 (A Performance Test on Exterior T-type Joint for RCS Composite System)

  • 양승렬;이상호;김병국;정하선;김종락;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.977-982
    • /
    • 2000
  • As a newly structural system, RCS composite system has been researched last two decades. However mechanism of exterior T-type joint for RCS composite system is not well known. This research is focus on the exterior T-type joint for RCS composite system. Specimens are designed by the ASCE guideline, tested and compared with the inner RCS joint. Test variables include face bearing plate(FBP), extended face bearing plate(E-FBP) and U-bar. The tests indicate that the strength of exterior T-type joint is higher than that of the guideline by ASCE. The U-bar has a significant effect on the joint strength and absorbing the strain energy.

용융탄산염 연료전지용 하이브리드 타입 센터 플레이트의 설계 및 제작 (Design and Production of Hybrid Type Center Plate for Molten Carbonate Fuel Cell)

  • 이창환;류승민;양동열;강동우;장인갑;이태원
    • 소성∙가공
    • /
    • 제20권4호
    • /
    • pp.273-278
    • /
    • 2011
  • Employing the TRIZ problem solving technique, a hybrid-type center plate for the molten carbonate fuel cell(MCFC) was developed for the purpose of improving gas sealing and maintenance. The manufacturing method of the hybrid-type center plate was divided into a trimming operation and a two-step bending process. In the latter, a modified punch shape was used to reduce springback. Using finite element(FE) simulations, bending stresses in the thickness and the in-plane directions were computed and the bending conditions were optimized. The optimized results of the two-step bending process were used as a basis for the design of the trimming process of the hybrid-type center plate. Finally, the external manifold-type center plate and the hybrid-type center plate were fabricated using a die set that accounts for the optimized conditions. It was found that the numerical simulation results were in good agreement with the experiments.

직교이방성판요소를 사용한 철근콘크리트거더교량의 해석 (Analysis of RC girder bridges using orthotropic plate elements)

  • 오병환;박종범;김세훈;김지상
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.552-555
    • /
    • 2004
  • For the estimation of the load effects of the slab-an-girder type structures, the applicability of FEM analysis for RC T-type girder bridges using orthotropic plate elements has been studied in the present study. The present study indicates that the analysis by orthotropic plate elements for RC T-type girder bridges gives reasonable results for sectional force, including moments and shear. The results from the present method gives the values in between full composite and non-composite cases, which are reasonable when compared with actual test results.

  • PDF

Analysis of Sternal Fixation Results According to Plate Type in Sternal Fracture

  • Byun, Chun Sung;Park, Il Hwan;Hwang, Wan Jin;Lee, Yeiwon;Cho, Hyun Min
    • Journal of Chest Surgery
    • /
    • 제49권5호
    • /
    • pp.361-365
    • /
    • 2016
  • Background: Sternal fractures are relatively rare, and caused mainly by blunt anterior chest wall trauma. In most cases, sternal fractures are treated conservatively. However, if the patient exhibits problematic symptoms such as intractable chest wall pain or bony crepitus due to sternal instability, surgical correction is indicated. But no consensus exists regarding the most appropriate surgical method. We analyzed the results of surgical fixation in cases of sternal fracture in order to identify which surgical method led to the best outcomes. Methods: We retrospectively reviewed the medical records of patients with sternal fractures from December 2008 to December 2011, and found 19 patients who underwent open reduction and internal fixation of the sternum with a longitudinal plate (L-group) or a T-shaped plate (T-group). We investigated patients' characteristics, clinical details regarding each case of chest trauma, the presence of other associated injuries, the type of open reduction and fixation, whether a combined operation was performed, and postoperative complications. Results: Of the 19 patients, 10 patients (52.6%) were male, and their average age was 56.8 years (range, 32 to 82 years). Seven patients (36.8%) had isolated sternal fractures, while 12 (63.2%) had other associated injuries. Seven patients (36.8%) were in the L-group and 12 patients (63.2%) were in the T-group. Three patients in the L-group (42.9%) showed a loosening of the fixation. In all patients in the T-group, the fracture exhibited stable alignment. Conclusion: Open reduction and internal fixation with a T-shaped plate in sternal fractures is a safer and more efficient treatment method than treatment with a longitudinal plate, especially in patients with a severely displaced sternum or anterior flail chest, than a longitudinal plate.

기-액 상변화 열전달식 고온 히터 플레이트의 작동 특성과 성능에 관한 연구 (A Study on the Heat Transfer Characteristics and Performance of the High Temperature Range Heater Plate Using Liquid-Vapor Phase Change Heat Transfer)

  • 강환국;임광빈
    • 한국표면공학회지
    • /
    • 제46권6호
    • /
    • pp.283-289
    • /
    • 2013
  • The experimental study for the temperature uniformity on the wafer using liquid-vapor phase heat transfer mechanism is performed. For the experiment, the heater plate which is consist of stainless steel container, working fluid and electrical heater is designed, manufactured and tested at the range of 600 to $850^{\circ}C$. The results showed that the phase change type heater plate was much more uniform and stable temperature on the heater plate surface and wafer than the uniform heat flux type heater plate at the atmospheric condition. Also, the results of 300 mm outer diameter of heater plate showed that the same temperature uniformity compared with 230 mm.

절곡강판을 이용한 교량용 강-콘크리트 합성 바닥판의 피로 성능평가 (Fatigue Strength Evaluation of Steel-Concrete Composite Bridge Deck with Corrugated Steel Plate)

  • 안진희;심정욱;정연주;김상효
    • 한국강구조학회 논문집
    • /
    • 제20권6호
    • /
    • pp.731-740
    • /
    • 2008
  • 본 연구는 하부 절곡강판과 T형강을 D16mm 스터드 전단연결재를 이용하여 콘크리트와 일체화시킨 교량용 강합성 바닥판의 피로 거동 및 피로성능을 평가하기 위한 것이다. 제안된 강합성 바닥판의 피로성능 평가를 위하여 총 8본의 시험체가 제작되었으며, 각각의 시험체에 3 종류의 일정진폭을 가진 피로하중이 재하되었다. 피로실험결과, 피로균열은 강합성 바닥판 하부 절곡강판의 절곡점에서 발생하여 상부 T형강으로 진전되는 것으로 나타났으며, 피로하중에 따라 시험체의 변위 및 변형률이 증가하고 피로균열발생 후 변위와 변형률이 급격히 변화하였다. 제안된 강합성 바닥판의 피로강도는 도로교설계기준 및 도로교설계기준 피로상세 범주의 자료가 된 NCHRP 102와 NCHRP 147 보고서의 피로실험결 과와 비교하여 평가한 결과 대상 강합성 바닥판은 피로상세 범주 C에 해당하는 것으로 평가되었다.

패치 로딩을 받는 알루미늄 합금 A6082-T6 사각형 판의 임계 탄성좌굴하중 검토 (Critical Elastic Buckling Load Investigation of Aluminium Alloy A6082-T6 Square plate Subjected to Patch Loading)

  • 오영철;고재용
    • 해양환경안전학회지
    • /
    • 제20권4호
    • /
    • pp.451-460
    • /
    • 2014
  • 본 연구에서 해양플랜트 구조물에 주로 사용하고 있는 알루미늄 합금 A6082-T6의 재료특성을 반영한 사각형 판에 대한 패치 로딩의 구조 안정성 문제를 검토하였다. 구조 안정성 문제를 검토 시 네 가지 패치 로딩 형태와 종횡비 효과, 주변지지조건을 적용하여 임계 탄성 좌굴하중을 산출하였다. 고유치 좌굴해석 간 사용한 요소는 4절점 쉘요소 shell181을 적용하였다. 패치 로딩을 받는 판은 균일 축 압축하중과 비교 시 상이한 탄성 좌굴거동이 발생되는 것을 관찰할 수 있었으며 하중형태와 위치, 종횡비 효과 등과 같은 변수에 대해 상당히 영향을 받고 있는 것을 확인할 수 있다. 또한, 종횡비(a/b) 1.0, 하중길이(${\gamma}b$) 200 mm 단순지지 사각형 판에서 패치 로딩 형태에 따른 임계 탄성좌굴하중은 67 %(하중 I), 119 %(하중 II), 76 %(하중 III), 160 %(하중 IV)이 각각 산출되었으며 하중 I과 III은 하중 II와 IV보다 훨씬 더 탄성 좌굴거동에 강한 것으로 판단할 수 있다.

Displacement and stress distribution of the maxillofacial complex during maxillary protraction using palatal plates: A three-dimensional finite element analysis

  • Eom, Jusuk;Bayome, Mohamed;Park, Jae Hyun;Lim, Hee Jin;Kook, Yoon-Ah;Han, Seong Ho
    • 대한치과교정학회지
    • /
    • 제48권5호
    • /
    • pp.304-315
    • /
    • 2018
  • Objective: The purpose of this study was to analyze initial displacement and stress distribution of the maxillofacial complex during dentoskeletal maxillary protraction with various appliance designs placed on the palatal region by using three-dimensional finite element analysis. Methods: Six models of maxillary protraction were developed: conventional facemask (Type A), facemask with dentoskeletal hybrid anchorage (Type B), facemask with a palatal plate (Type C), intraoral traction using a Class III palatal plate (Type D), facemask with a palatal plate combined with rapid maxillary expansion (RME; Type E), and Class III palatal plate intraoral traction with RME (Type F). In Types A, B, C, and D, maxillary protraction alone was performed, whereas in Types E and F, transverse expansion was performed simultaneously with maxillary protraction. Results: Type C displayed the greatest amount of anterior dentoskeletal displacement in the sagittal plane. Types A and B resulted in similar amounts of anterior displacement of all the maxillofacial landmarks. Type D showed little movement, but Type E with expansion and the palatal plate displayed a larger range of movement of the maxillofacial landmarks in all directions. Conclusions: The palatal plate served as an effective skeletal anchor for use with the facemask in maxillary protraction. In contrast, the intraoral use of Class III palatal plates showed minimal skeletal and dental effects in maxillary protraction. In addition, palatal expansion with the protraction force showed minimal effect on the forward movement of the maxillary complex.