• 제목/요약/키워드: T-type inverter

검색결과 96건 처리시간 0.037초

Research on the Mechanism of Neutral-point Voltage Fluctuation and Capacitor Voltage Balancing Control Strategy of Three-phase Three-level T-type Inverter

  • Yan, Gangui;Duan, Shuangming;Zhao, Shujian;Li, Gen;Wu, Wei;Li, Hongbo
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2227-2236
    • /
    • 2017
  • In order to solve the neutral-point voltage fluctuation problem of three-phase three-level T-type inverters (TPTLTIs), the unbalance characteristics of capacitor voltages under different switching states and the mechanism of neutral-point voltage fluctuation are revealed. Based on the mathematical model of a TPTLTI, a feed-forward voltage balancing control strategy of DC-link capacitor voltages error is proposed. The strategy generates a DC bias voltage using a capacitor voltage loop with a proportional integral (PI) controller. The proposed strategy can suppress the neutral-point voltage fluctuation effectively and improve the quality of output currents. The correctness of the theoretical analysis is verified through simulations. An experimental prototype of a TPTLTI based on Digital Signal Processor (DSP) is built. The feasibility and effectiveness of the proposed strategy is verified through experiment. The results from simulations and experiment match very well.

T형 3레벨 인버터 중성점 전압의 모델예측제어 (Model predictive control for T-type 3-level inverter neutral point)

  • 김태훈;이우철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 추계학술대회 논문집
    • /
    • pp.145-146
    • /
    • 2015
  • 본 논문은 3상 T-type 3-레벨 인버터의 중성점 전압 제어를 위한 예측제어에 관한 연구이다. 최근 인버터의 효율 향상 등의 장점으로 멀티레벨 인버터가 주목받고 있다. 모델예측제어 방식은 물리적 입력 상태를 반영하여 최적의 성능을 제공할 수 있는 제어기법이다. 3-레벨 인버터에서는 전압벡터의 개수가 많아 예측제어기법을 적용하기에는 계산시간이 오래걸리는 단점이 있다. 본 논문에서는 SPWM 방식에 예측저어를 통해 offset 을 주는 방식으로 DC-link단 중성점 전압제어를 하였다.

  • PDF

다중공진 영전류 스위칭을 이용한 고주파 유도가열용 인버터 (High Frequency Inverter for Induction Heating with Multi-Resonant Zero Current Switching)

  • 라병훈;서기영;이현우;김광태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.38-40
    • /
    • 2002
  • In the case of conventional high frequency inverter, with damage of switch by surge voltage when switch gets into compulsion extinction by load accident and so on because reactor is connected by series to switch, or there was problem of conduction loss by reactor's resistivity component, Also, it has controversial point of that can not ignore conduction loss of switch in complete work kind action of soft switching. In this paper, as high frequency induction heating power supply, we propose half bridge type multi resonance soft switching high frequency inverter topology that can realize high amplitude operation of load current with controlling switch current by multiplex resonance, mitigating surge voltage when switch gets into compulsion extinction and to be complete operation of zero current switching by opposit parallel connected reactor to inverter switch. and do circuit analysis for choice of most suitable circuit parameter of circuit

  • PDF

3레벨 T-type 계통연계 인버터용 출력 필터 설계 (Design of Output Filter for Grid Connected 3-level T-type Inverter)

  • 안효민;오창열;장은수;이병국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.317-318
    • /
    • 2016
  • 본 논문에서는 3레벨 T-type 계통연계 인버터의 출력 전류 리플 특성 분석을 통하여 출력 필터 설계 방법을 제시한다. 제시한 설계 방법을 이용하여 국제 고조파 기준에 부합하는 3레벨 T-type 계통연계 인버터용 출력 필터를 설계하며, 이를 시뮬레이션을 통하여 검증한다.

  • PDF

3-레벨 T-Type 인버터 기반 에너지 저장장치 설계 및 제어 (Design and Control of Energy Storage System Based on 3-Level T-Type Inverter)

  • 오창열;안효민;박상민;이병국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.257-258
    • /
    • 2016
  • 본 논문에서는 3-레벨 T-type 인버터를 적용한 에너지 저장장치 시스템의 설계 및 제어 전략을 제시한다. 3-레벨 T-type 인버터의 양방향 및 에너지 저장장치의 동작 특성에 기반한 전체 시스템의 설계 고려사항을 제시하고, 이를 효율적으로 운용할 수 있도록 제어 전략을 수립하고 제어기를 구성한다. 또한, 제시한 설계 고려사항 및 제어 전략의 성능평가를 통해 그 동작을 검증한다.

  • PDF

T-type 3-레벨 인버터 제어를 위한 예측제어 방법 (Predictive control method for T-type 3-level inverter)

  • 김태훈;이우철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.331-332
    • /
    • 2015
  • 본 논문은 3상 T-type 3-레벨 인버터에 적용할 수 있는 예측제어 방법에 관한 논문이다. 최근 인버터의 효율 향상 등의 장점으로 멀티레벨 인버터가 주목받고 있다. 그중 T-type 방식은 저전압, 중전압에서 강점이 있는 토폴로지이며, 예측제어 방식은 직관적이고 쉽게 이해가능한 스위치 제어방법이다. 3-레벨 인버터에서는 전압벡터의 개수가 많아 예측제어기법을 적용하기에는 계산시간이 오래걸리는 단점이 있다. 본 논문에서는 CB PWM 방식에 예측값으로 offset을 주는 방식으로 DC단 중성점 전압제어와 출력전압제어를 하였다.

  • PDF

오프셋 전압을 이용한 계통 연계형 3상 3레벨 T-type 태양광 PCS의 중성점 전압 불평형 보상 (Compensation of Unbalanced Neutral Voltage for Grid-Connected 3-Phase 3-Level T-type Photovoltaic PCS Using Offset Voltage)

  • 박관남;최익;최주엽;이영권
    • 한국태양에너지학회 논문집
    • /
    • 제37권6호
    • /
    • pp.1-12
    • /
    • 2017
  • The DC link of Grid-Connected 3-Phase 3-Level T-type Photovoltaic PCS (PV-PCS) consists of two series connected capacitors for using their neutral voltage. The mismatch between two capacitor characteristics and transient states happened in load change cause the imbalance of neutral voltage. As a result, PV-PCS performance is degraded and the system becomes unstable. In this paper, a mathematical model for analyzing the imbalance of neutral voltage is derived and a compensation method using offset voltage is proposed, where offset voltage adjusts the applying time of P-type and N-type small vectors. The validity of the proposed methods is verified by simulation and experiment.

Experiences with Simulation Software for the Analysis of Inverter Power Sources in Arc Welding Applications

  • Fischer W.;Mecke H.;Czarnecki T.K.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.731-736
    • /
    • 2001
  • Nowadays various simulation tools are widely used for the design and the analysis of power electronic converters. From the engineering point of view it is rather difficult to parameterize power semiconductor device models without the knowledge of basic physical parameters. In recent years some data sheet driven behavioral models or so called 'wizard' tools have been introduced to solve this problem. In this contribution some experiences with some user-friendly power semiconductor models will be discussed. Using special simulation test circuits it is possible to get information on the static and dynamic behavior of the parameterized models before they are applied in more complex schemes. These results can be compared with data sheets or with measurements. The application of these models for power loss analysis of inverter type arc welding power sources will be described.

  • PDF

전동차용 IGBT형 추진제어장치의 6호선 본선 만차 시험에 관한 연구 (A Study On Full Load Test of IGBT Type Propulsion System for Electric Railway in SMG 6 Line)

  • 박건태;정만규;고영철;방이석;서광덕
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.666-673
    • /
    • 2000
  • This paper describes the full load test results of IGBT VVVF inverter for the railway propulsion system. The 1,650kVA IGBT VVVF inverter has been developed. Therefore, the field test is performed in SMG 6 Line to confirm its the reliability and performance. The train consists of 4M4T(4 Motor car 4 Trailer Car) and the electrical equipment for field test are as follows VVVF inverter 4 sets, 16 traction motors and 2 SIVs. The propulsion system is composed with IC4M(1-Controller 4-Motors). The results of propulsion system which have the excellent acceleration/deceleration and the jerk characteristics as well as starting ability on slope are taken through the field test.

  • PDF

인젝션용 스크롤 압축기의 성능특성에 관한 실험적 연구 (Experimental Study on the Performance Characteristics of an Injection Type Scroll Compressor)

  • 조홍현;김용찬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.193-198
    • /
    • 2000
  • For an inverter-driven compressor, the discharge temperature increased with a rise of frequency, Therefore, it is necessary to control the discharge temperature at high frequencies in order to obtain system reliability and efficiency. This paper describes the effects of liquid injection system on the performance of an inverter-driven scroll compressor. Experiments were performed at ASHRAE-T conditions. Frequency was altered from 45 to 105Hz. As results of the present work, the refrigerant discharge temperature fur the injection system was dropped approximately $10{\sim}20^{\circ}C$ as compared to those for the non-injection system. The COP of the compressor was improved approximately $0.8{\sim}9.3%$ at high frequencies(75, 90, and 105 Hz).

  • PDF