• Title/Summary/Keyword: T-pipe

Search Result 397, Processing Time 0.024 seconds

An Analytical Study on Influence of Longitudinal Stiffeners on Seismic Performance of Circular Steel Columns (수직보강재가 원형강기둥의 이력거동에 미치는 영향에 대한 해석적 연구)

  • Jang, Gab-Chul;Chang, Kyong-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.1 s.23
    • /
    • pp.63-70
    • /
    • 2007
  • To improve the land use of urban, Construction of the circular steel column is required recently. The circular steel columns have a advantage for improving a load carrying rapacity as wall as reducing a effective section area. However, the circular steel columns under service load, such as earthquake, shows a tendency to cause local buckling and large deformation. To prevent these phenomena, use of longitudinal stiffeners is considered. The application of longitudinal stiffeners at the circular steel columns is expected to increase a load carrying capacity, buckling strength and seismic performance of circular steel column. However, increasing the loading carving rapacity of buckling which constructed the longitudinal stiffeners, was not investigated yet. Therefore it needs study on effect of longitudinal stiffener in pipe-section steel pier. In this study, the load rallying capacity of buckling of steel pier was investigated by using elastic-plastic finite element analysis considered geometrical and material non-linearity. Also, this study investigated the effect of longitudinal stiffeners on loading carrying capacity of buckling and the relationship between width and thickness of longitudinal stiffeners. And also, a Influence of longitudinal stiffeners on seismic performance of circular steel columns was investigated by numerical analysis

  • PDF

Application of the Flowerbed Type Infiltration System for Low Impact Development - Focus on the Application to Eco-Village - (저부하형 개발을 위한 화단형 빗물침투시설 적용방안 - 생태전원마을에서의 적용을 중심으로 -)

  • Han, Young-Hae;Lee, Tae-Goo;Schuetze, T.
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.33-40
    • /
    • 2012
  • Since 2000 country region developmental policy has been to integrate not only the improvement of physical living environment but also various subjects on ecology, environment, scenery, local culture, and green tourism. This study has recently established a decentralized Rainwater Management plan in order to provide an hydrology cycle system to the eco-village being planned by Seocheon-gun as a part of the garden village development business promoted by the ministry of agriculture and forestry. Hydraulic conductivity of the subject area is measured at $10^{-7}{\sim}10^{-10}m/sec$, and a flowerbed-type rainwater Infiltration system capable of controlling a non-point pollution source that stems from the development-caused impermeable surface has been applied. In the case of rainwater flowing out from the main entrance way and parking lot within the complex being treated in the flowerbed-type rainwater infiltration system, natural purification effects via soil and plants as well as natural water cycling effects through evaportranspiration and infiltration are expected. The significance of this study, compared to conventional decentralized rainwater management being applied limited to the urban areas, is that it offers appropriate rainwater management planning based on the analysis of the current situation of the subject area. Decentralized Rainwater Management is a valuable measure both economically and ecologically that reduces the burdens on local underground water cultivation as well as rain water pipe lines or purification systems, and sewage pipes.

Radionuclides of Ground waters in Busan (부산지역 지하수의 방사성물질 특성)

  • Jeon, Dae-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.5
    • /
    • pp.51-61
    • /
    • 2009
  • This study was performed to research the characteristic of radionuclides of 80 groundwater monitoring networks in Busan. According to the research, average concentration of Uranium was $4.33\;{\mu}g/L$, maximum concentration of Uranium was $171.55\;{\mu}g/L$ among the 80 sampling sites. One sample exceeded the Proposal standard of drinking water in USA in Uranium ($30\;{\mu}g/L$) and four samples exceeded the recommendatory value of WHO about Uranium ($15\;{\mu}g/L$). Radon and gross-$\alpha$ concentration of all samples were far less than the Proposal standard of drinking water in USA. In this study average concentration of radionuclides in underground water wasn't too high, but needed to control the concentration of them to prevent exposure to the people. And it needs to be taken measures in some sites with high concentration of Uranium by closing the pipe line or etc through more studies.

A Presentation on the Manual Hydraulic Calculation Method of the Loop Type Fire Sprinkler System (Loop형 스프링클러 설비의 수리계산 방법에 대한 제시)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.73-79
    • /
    • 2015
  • There are three kinds of design method of the fire sprinkler systems. Grid type is connected all branch as a trapezoid. Loop type is connected cross-mains like circle. The last one is a tree type most commonly used. Grid type needs computer program to calculate the friction loss and flow rate apart from very simple form. In loop type, manual calculation is possible. Design engineer can draw up and calculate the demands without computer program. Because water supplies two direction in loop type, friction loss is smaller than tree type. Water distribution in operation area is uniform because of the small differences of sprinklers discharge pressure. Loop type is superior to tree type in respect of total pressure and flow rate. Using the small diameter pipe, the labor and construction cost will be decreased in the end. Loop type sprinkler design is rarely laid out because design engineers don't know the method. This paper is intended to inform that the loop type is better than the tree type in performance and economic point of view. And also this paper intend to use the loop type easily and widely.

A design of Giga-bit security module using Fully pipe-lined CTR-AES (Full-pipelined CTR-AES를 이용한 Giga-bit 보안모듈 설계)

  • Vinh, T.Q.;Park, Ju-Hyun;Kim, Young-Chul;Kim, Kwang-Ok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.6
    • /
    • pp.1026-1031
    • /
    • 2008
  • Nowdays, homes and small businesses rely more and more PON(Passive Optical Networks) for financial transactions, private communications and even telemedicine. Thus, encryption for these data transactions is very essential due to the multicast nature of the PON In this parer, we presented our implementation of a counter mode AES based on Virtex4 FPGA. Our design exploits three advanced features; 1) Composite field arithmetic SubByte, 2) efficient MixColumn transformation 3) and on-the-fly key-scheduling for fully pipelined architecture. By pipeling the composite field implementation of the S-box, the area cost is reduced to average 17 percent. By designing the on-the-fly key-scheduling, we implemented an efficient key-expander module which is specialized for a pipelined architecture.

A Convergence Study on Waterline Management of Unit Chair in Dental Hygiene Laboratory (교내 실습실의 유니트체어의 수관관리에 관한 융합연구)

  • Choi, Jung-OK
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.10
    • /
    • pp.27-31
    • /
    • 2019
  • The purpose of this study is to gather biofilm of unit chair waterline in the laboratory, to analyze microorganisms, to apply the existing draw-off method and the method of using disinfectant, and to compare the change of the number of microorganisms. The water was provided by the waterline of the unitchair, and the gathered samples were cultured with the use of R2A agar plate. Bacterial species separated through the identification of microorganisms were analyzed. To identify the decrease of microorganism for draw-off, samples were gathered in the intervals of 30 seconds, 60 seconds and 120 seconds, and to identify the effect of disinfectant, samples after disinfection were gathered. The quantitative comparison of microorganisms through the gathered samples was done by SPSS program. The number of identified bacteria are 8 species, most of which are gram-negative bacterium, and Sphingomonas type. The rapid decrease of the number of microorganism through draw-off for 60 seconds was confirmed, and microorganisms after disinfection weren't detected right away. Based on the method and result of this study, the water pipe of unit chair, which can be neglected easily, can be managed, so cross infection can be prevented, and systemic management can be possible.

The influence of nano-silica on the wear and mechanical performance of vinyl-ester/glass fiber nanocomposites

  • Sokhandani, Navid;Setoodeh, AliReza;Zebarjad, Seyed Mojtaba;Nikbin, Kamran;Wheatley, Greg
    • Advances in nano research
    • /
    • v.13 no.1
    • /
    • pp.97-111
    • /
    • 2022
  • In the present article, silica nanoparticles (SNPs) were exploited to improve the tribological and mechanical properties of vinyl ester/glass fiber composites. To the best of our knowledge, there hasn't been any prior study on the wear properties of glass fiber reinforced vinyl ester SiO2 nanocomposites. The wear resistance is a critical concern in many industries which needs to be managed effectively to reduce high costs. To examine the influence of SNPs on the mechanical properties, seven different weight percentages of vinyl ester/nano-silica composites were initially fabricated. Afterward, based on the tensile testing results of the silica nanocomposites, four wt% of SNPs were selected to fabricate a ternary composite composed of vinyl ester/glass fiber/nano-silica using vacuum-assisted resin transfer molding. At the next stage, the tensile, three-point flexural, Charpy impact, and pin-on-disk wear tests were performed on the ternary composites. The fractured surfaces were analyzed by scanning electron microscopy (SEM) images after conducting previous tests. The most important and interesting result of this study was the development of a nanocomposite that exhibited a 52.2% decrease in the mean coefficient of friction (COF) by augmenting the SNPs, which is beneficial for the fabrication/repair of composite/steel energy pipelines as well as hydraulic and pneumatic pipe systems conveying abrasive materials. Moreover, the weight loss due to wearing the ternary composite containing one wt% of SNPs was significantly reduced by 70%. Such enhanced property of the fabricated nanocomposite may also be an important design factor for marine structures, bridges, and transportation of wind turbine blades.

Impact-resistant design of RC slabs in nuclear power plant buildings

  • Li, Z.C.;Jia, P.C.;Jia, J.Y.;Wu, H.;Ma, L.L.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3745-3765
    • /
    • 2022
  • The concrete structures related to nuclear safety are threatened by accidental impact loadings, mainly including the low-velocity drop-weight impact (e.g., spent fuel cask and assembly, etc. with the velocity less than 20 m/s) and high-speed projectile impact (e.g., steel pipe, valve, turbine bucket, etc. with the velocity higher than 20 m/s), while the existing studies are still limited in the impact resistant design of nuclear power plant (NPP), especially the primary RC slab. This paper aims to propose the numerical simulation and theoretical approaches to assist the impact-resistant design of RC slab in NPP. Firstly, the continuous surface cap (CSC) model parameters for concrete with the compressive strength of 20-70 MPa are fully calibrated and verified, and the refined numerical simulation approach is proposed. Secondly, the two-degree freedom (TDOF) model with considering the mutual effect of flexural and shear resistance of RC slab are developed. Furthermore, based on the low-velocity drop hammer tests and high-speed soft/hard projectile impact tests on RC slabs, the adopted numerical simulation and TDOF model approaches are fully validated by the flexural and punching shear damage, deflection, and impact force time-histories of RC slabs. Finally, as for the two low-velocity impact scenarios, the design procedure of RC slab based on TDOF model is validated and recommended. Meanwhile, as for the four actual high-speed impact scenarios, the impact-resistant design specification in Chinese code NB/T 20012-2019 is evaluated, the over conservation of which is found, and the proposed numerical approach is recommended. The present work could beneficially guide the impact-resistant design and safety assessment of NPPs against the accidental impact loadings.

Modification of an LPG Engine Generator for Biomass Syngas Application (바이오매스 합성가스 적용을 위한 LPG 엔진발전기 개조 및 성능평가)

  • Eliezel, Habineza;Hong, Seong Gu
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.5
    • /
    • pp.9-16
    • /
    • 2022
  • Syngas, also known as synthesis gas, synthetic gas, or producer gas, is a combustible gas mixture generated when organic material (biomass) is heated in a gasifier with a limited airflow at a high temperature and elevated pressure. The present research was aimed at modifying the existing LPG engine generator for fully operated syngas. During this study, the designed gasifier-powered woodchip biomass was used for syngas production to generate power. A 6.0 kW LPG engine generator was modified and tested for operation on syngas. In the experiments, syngas and LPG fuels were tested as test fuels. For syngas production, 3 kg of dry woodchips were fed and burnt into the designed downdraft gasifier. The gasifier was connected to a blower coupled with a slider to help the air supply and control the ignition. The convection cooling system was connected to the syngas flow pipe for cooling the hot produce gas and filtering the impurities. For engine modification, a customized T-shaped flexible air/fuel mixture control device was designed for adjusting the correct stoichiometric air-fuel ratio ranging between 1:1.1 and 1.3 to match the combustion needs of the engine. The composition of produced syngas was analyzed using a gas analyzer and its composition was; 13~15 %, 10.2~13 %, 4.1~4.5 %, and 11.9~14.6 % for CO, H2, CH4, and CO2 respectively with a heating value range of 4.12~5.01 MJ/Nm3. The maximum peak power output generated from syngas and LPG was recorded using a clamp-on power meter and found to be 3,689 watts and 5,001 watts, respectively. The results found from the experiment show that the LPG engine generator operated on syngas can be adopted with a de-ration rate of 73.78 % compared to its regular operating fuel.

Operating result of Hydroxyapatite Crystallization-Filtration (HCF) process and characterization of its sludge for wastewater effluent (하수 인 고도처리를 위한 인 결정여과공정 운전결과 및 부산슬러지 특성 검토)

  • Chang, Hyang-Youn;Kim, Weon-Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.401-401
    • /
    • 2022
  • 우리나라 대규모 하수처리장에 상용화되어있는 응집공정의 운영상 난점을 극복하고자 대체공정으로 고안된 인 결정여과공정(HCF, Hydroxyapatite Crystallization-Filtration process)의 pilot plant를 구축하고 부산슬러지의 자원화를 위해 그 특성을 검토하였다. 기존의 hydroxyapatite(HAP) 결정화공정 내 탈탄산(decarbonation) 단계를 생략하는 HCF공정의 경우에 고농도의 Ca2+ 주입과 처리수내 탄산염으로 인해 HAP을 포함하는 석회계 슬러지가 발생하는데, 이는 산성화된 토양의 개량제(중화제)로 널리 사용될 수 있다. 본 연구를 위해 경기도 I하수처리장 2차침전지 후단에 구축된 처리용량 27.1 - 135.6 m3/day HCF pilot plant의 전처리 조건은 pH 10.0 - 11.0, Ca2+ 농도 80 mg/L이었다. 결정여과조는 선속도 1.0 - 5.0 m/hr, 상향류로 운전되며, 여재는 2.0 - 3.0 mm의 석회석 모래를 충전하였다. 역세척은 중앙에 Air lifting pipe를 설치하여 역세척수가 처리수와 분리배출되도록 설계하였고, 침전시켜 역세척 슬러지를 회수하였다. 처리수의 평균 T-P, PO4-P 및 SS는 각각 0.05, 0.04, 1.1 mg/L으로 모든 항목에서 방류수 수질기준 이하로 안정적으로 유출되었다. 회수된 HCF 슬러지는 SEM-EDX, XRD, FT-IR을 활용하여 그 특성을 분석하였다. SEM-EDX로 분석된 슬러지의 원자분율은 CaCO3 또는 HAP으로 추측되었다. 또한, XRD spectrum 분석결과, 슬러지의 주요 구성성분은 calcite, HAP, phosphoric acid(H3PO4) 및 brusite로 나타났다. FT-IR 분석결과, 슬러지는 대부분 인산염 및 탄산염의 무기물로 구성되어 있으며, 유입수의 인 농도가 높을수록 슬러지 내 HAP의 함량이 calcite보다 높은 것으로 나타났다. 고농도의 Ca2+을 주입하여 탈탄산단계를 생략한 HCF의 부산슬러지는 HAP 이외에도 CaCO3와 칼슘-인 화합물로 구성되어 있는 것으로 나타났다. 하수 인 고도처리를 위한 HCF공정의 하수처리시설 인 고도처리 적용이 검증되었으며, 부산슬러지를 산성화된 토양의 개량제(중화제) 또는 비료로서의 재활용 및 자원화 가능성이 시사되었다.

  • PDF