• 제목/요약/키워드: T-pipe

검색결과 399건 처리시간 0.031초

비틀림 유도파를 이용한 근지표면 전단속도 규명 (Identification of the Shear Velocities of Near Surface Soils Using Torsional Guided Waves)

  • 박경조;오형수
    • 한국소음진동공학회논문집
    • /
    • 제22권8호
    • /
    • pp.771-776
    • /
    • 2012
  • A technique is presented that uses a circular waveguide for the measurement of the bulk shear(S-wave) velocities of unconsolidated, saturated media, with particular application to near surface soils. The technique requires the measurement of the attenuation characteristics of the fumdamental T(0,1) mode that propagates along an embedded pipe, from which the acoustic properties of the surrounding medium are inferred. From the dispersion curve analysis, the feasibility of using T(0,1) mode which is non-dispersive and have constant attenuation over all frequency range is discussed. The principles behind the technique are discussed and the results of an experimental laboratory validation are presented. The experimental data are best fitted for the different depths of wetted sand and the shear velocities as a function of depths are formulated using power law curves.

결함 평가에서 용접 잔류응력 분포의 영향 (Effect of Residual Stress Distributions in Defect Assessment)

  • 이세환;이형연;김종범;이재한
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2006년 추계학술발표대회 개요집
    • /
    • pp.15-17
    • /
    • 2006
  • Weld residual stresses can be a major concern in structural integrity assessments such as a nuclear power plant. In this paper, detailed weld residual stress analyses were presented for a typical multi-pass weld of pipe-butt weld and plate T-butt weld. The calculated residual stress distributions were compared with those of the measured data and recommended profiles in R6 and BS7910. Defect assessment which is based on the stress intensity factor(SIF) calculations was carried out for a plate T-butt weld with cracks considering the weld residual stress distributions.

  • PDF

강관기둥과 PHC 파일을 연결하는 접합부에 관한 구조성능평가 (Structural Performance Evaluation of Joint between PHC Pile and Steel Tube Column)

  • 김상봉;오진탁;김영식;주영규
    • 한국공간구조학회논문집
    • /
    • 제15권3호
    • /
    • pp.85-93
    • /
    • 2015
  • This paper presents a foundation pile to steel column connection that can resist large magnitude of moment and that can be easy installed. The developed joint has spherical shape and it is given the name HAT joint to mean Hallow half-sphere steel joint. Four types of HAT joints are developed. Namely, H-type, T-type, P-type and K-type. In this paper I will talk about the performance assessment of T-type(Tube Column) and P-type(Pile Column) of HAT joints with finite element analysis and experiment on a full scale model is presented.

Mod. 9Cr1Mo 강의 크리프 강도에 미치는 경도의 영향 (Effects of hardness values on the creep rupture strength in a Mod. 9Cr1Mo Steel)

  • 이연수;유석현;공병욱;김정태
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.637-642
    • /
    • 2003
  • The Modified 9Cr-1Mo steel identified as T91, P91 and F91 in the ASME specification has been widely used for the construction of modern power plants. The available data on the influence of process parameters during manufacturing and fabrication on its properties are not sufficient. In this study, the influence of various thermal cycles on the hardness and the creep rupture strength was analyzed in the base metal and the weldments made in tube and pipe of a Mod.9Cr-1Mo steel. The low hardness, 155Hv, showed low creep rupture strength below the allowable stresses of T91 base metal in the ASME specification. This low value was attributed to the fully recovered dislocation structure and the weakening of precipitation hardening associated with the abnormal thermal cycles.

  • PDF

PIV 가시화에 의한 합류덕트에서의 유동특성 (Flow Characteristics for PIV Visualization at Junction Duct)

  • 김명관;권오붕;배대석
    • 동력기계공학회지
    • /
    • 제9권4호
    • /
    • pp.45-50
    • /
    • 2005
  • Characteristics of flows at T-junction duct with and without orifices are investigated in this paper. Experiments and PIV visualization were carried out for several flow rates. Two-dimensional PIV experimental apparatus was decided by numerical analysis. PIV visualization was also coded to visualize flow fields at junctions for two-dimensional case. For the PIV visualization system, Grey-Level Cross-Correlation particle tracking algorithm was used to calculate the flow fields. Vinyl chloride polymer particles of $100{\sim}150{\mu}m$ of diameter are used in this visualization. The PIV visualization results showed relatively good agreement with Experimental data.

  • PDF

염소 접촉조 직렬 연결시 수리흐름 특성에 관한 연구 (Case study on Hydraulic characteristics within Chlorine Contactors in Series)

  • 강태훈;채선하;김성수;왕창근
    • 상하수도학회지
    • /
    • 제25권4호
    • /
    • pp.497-502
    • /
    • 2011
  • In order to examine the effects of combination of plug flow reactors in series on hydraulic characteristics, comparative tracer tests were conducted for the cases of the existing clear well and clear wells combined in series. From the results of tests, $T_{10}$/T within existing clear well was 0.62~0.68 depending on inlet flowrate, and that in the case of combination in series was 0.69~0.78. While it would be minor improvement in contact efficiency, it would be appropriate to combine two clearwell with pipe in series for expansion.

3D+t 관상동맥표현을 위한 매개변수 모델링 (Parametric Modeling Approach to Represent 3D+t Coronary Arteries)

  • 송수민;이유부;최유주;김명희
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제11권1호
    • /
    • pp.50-54
    • /
    • 2005
  • 본 논문은 관상동맥의 구조와 그 움직임을 사실적으로 표현하기 위한 매개변수적 모델링기법을 제안한다. 매개변수적 기법으로 생성된 모델은 메쉬 정점의 인덱스만으로 모델간 매칭을 위한 대응점을 찾을 수 있으므로, 시간대별로 달라지는 정점의 위치를 쉽게 추적함으로써 모델의 움직임을 표현할 수 있다. 그러나 이러한 기법으로 생성된 모델은 분리, 접합 등의 변형 조작이 어렵고, 트리형태 객체에 적용하기 힘든 단점이 있다. 본 논문에서는 이를 극복하기 위해 분할된 혈관영역의 골격데이타에서 찾아낸 분기점을 중심으로 Generalized Cylinder를 이용하여 실린더 형태의 각 혈관세그먼트를 모델링 한 후, 분기영역을 3 개의 하프파이프(half pipe)와 2 개의 삼각형 패치로 연결하여 모델링하였다. 완성된 모델은 다시점 관상동맥데이터에 적용하였고, 각 시점에서 구해진 정점의 위치를 선형보간함으로써 부드러운 혈관의 움직임을 나타내었다.

  • PDF

The Characteristics of Charging Water Spray at Electrostatic Precipitator

  • Chung, J.H.;Kanazawa, S.;Ohkubo, T.;Nomoto, Y.;Adachi, T.
    • 한국안전학회지
    • /
    • 제9권4호
    • /
    • pp.132-136
    • /
    • 1994
  • The new spray system is proposed by using a pipe with hygroscopic needle electrode In order to develop an air-cleaning ESP with high collection efficiency for submicron particles and high removal efficiency for NOx, SO$_2$, NH$_3$. Fundamental characteristics of charging water spray, which is not an usual wet type, are investigated experimentally. As a result, corona discharging mode and ozone generation rate are significantly affected by the operational conditions, such as the applied voltage and wet condition of the needle electrode.

  • PDF

유리온실의 태양열 집열방법별 집열효과 (Heating Efficiency of Difference Heat Collection Methods for Greenhouse)

  • 최영하;이재한;권준국;박동금;이한철
    • 생물환경조절학회지
    • /
    • 제9권3호
    • /
    • pp.166-170
    • /
    • 2000
  • 자연열(태양열)을 효율적으로 이용하기위해 1999년부터 2000년 까지 2년간 상면적이 100$m^2$인 3동의 유리온실에 각기 다른 집열시스템을 설치하였다. 즉, 집열면적과 경사도가 각각 24$m^2$, 50$^{\circ}$로서 현재 시판되고 있는 태양열 집열기(평판형, Solar hart Inc.)를 이용하는 방법, 직경과 송풍량이 각각 1m, 2.5m$^{-3}$.m$^{-2}$ .min로서 라디에이터가 부착된 2개의 유동팬을 천장부에 설치하고 천창을 밀폐한 후 온실상부의 열을 집열하는 방법, 온실의 중도리 전부를 물이 순환되는 각관 (75x45x3t, 1m 간격x10줄x온실길이 12m=120m)으로 설치하여 집열하는 방법 등으로 하였다. 각 동마다 지하에 26톤의 저수 능력을 갖는 D2000xW1500xL8600의 축열조를 설치한 후 중간을 막아 저온수조와 고온수조로 구분하였고, 수조 중간 1.5m 높이에 통수로를 내어 일정량의 물(약 15톤)이 지속적으로 순화될 수 있도록 하였다. 최저기온 9$^{\circ}C$로 설정하여 1,000$m^2$를 공간 난방할 경우 난방연료 절감율은 태양열 집열기, 유동팬 및 각관에서 각각 7%, 19%, 28%로 나타났다. 태양열 집열기를 이용하는 대부분의 농가에서는 40~50$m^2$ 정도의 집열면적을 갖는 집열기를 이용하고 있는데 이 경우 년간 난방연료 절감율은 14% 정도로서 경제성이 없으며, 유동팬도 집열효율에 비해 제작, 설치 및 유지비가 과다하게 소요되므로 경제성이 없다. 각관의 경우 관 자체의 자재비나 설치비에 추가부담이 적으면서 집열효율이 비교적 높기 때문에 관의 부식, 골조 표면적 증가에 의한 시설내 차광 증가, 중도리의 각형 구조로 인한 강도저하 등의 문제가 해결되면 집열 방법으로 고려될 수 있을 것이다.

  • PDF

고체기준전극 및 원격전위측정 시스템 개발에 관한 연구 (A Study on the Development of Solid Reference Electrode and Remote Protection Potential Measuring System)

  • 류영돈;김진준;김동균
    • 한국가스학회지
    • /
    • 제19권3호
    • /
    • pp.38-43
    • /
    • 2015
  • 지하에 매설된 도시가스 배관은 부식으로부터 보호하기 위하여 전기방식조치를 하도록 하고 있으며, 전기방식시설의 효과적인 유지관리를 위해 1년마다 배관의 전위를 측정 하도록 하고 있다. 방식전위의 측정은 테스트박스(T/B)에서 실시하게 되는데, 도심에 설치된 T/B의 경우 대부분 도로상에 설치되어 있어 전위를 측정할 때 어려움이 있다. 즉, 교통량이 많은 도로에서 전위를 측정하기 위해서는 차량을 통제하거나, 교통량이 적은 심야에 실시해야 하는 등 어려움이 있다. 본 연구에서는 이러한 방식전위 측정의 문제점을 해결하기 위해 고체기준전극 및 무선통신기술을 이용한 원격전위 측정시스템 개발에 관한 연구를 수행하였다. 고체기준 전극을 개발하여 실험실에서 성능테스트를 실시하고, 도시가스 배관이 설치된 현장에 직접 매설하여 전위 값의 변화를 관찰하였다. 또한, 무선통신을 이용하여 측정된 전위값을 서버로 전송하고, 사무실에서 전위값의 변화를 확인하였다. 고체기준전극을 이용한 전위값은 국내에서 사용되고 있는 타사 제품과 큰 차이가 없는 것으로 확인되었으며, 현장에서 측정한 전위 값과 웹서버로 보내진 전위값의 차이는 없었다. 개발된 고체기준전극은 향후 도심에 설치된 테스트 박스의 전위를 차량을 이용하여 측정하는데 사용할 계획이다.