• Title/Summary/Keyword: T-pipe

Search Result 399, Processing Time 0.039 seconds

Enhanced damage index method using torsion modes of structures

  • Im, Seok Been;Cloudt, Harding C.;Fogle, Jeffrey A.;Hurlebaus, Stefan
    • Smart Structures and Systems
    • /
    • v.12 no.3_4
    • /
    • pp.427-440
    • /
    • 2013
  • A growing need has developed in the United States to obtain more specific knowledge on the structural integrity of infrastructure due to aging service lives, heavier and more frequent loading conditions, and durability issues. This need has spurred extensive research in the area of structural health monitoring over the past few decades. Several structural health monitoring techniques have been developed that are capable of locating damage in structures using modal strain energy of mode shapes. Typically in the past, bending strain energy has been used in these methods since it is a dominant vibrational mode in many structures and is easily measured. Additionally, there may be cases, such as pipes, shafts, or certain bridges, where structures exhibit significant torsional behavior as well. In this research, torsional strain energy is used to locate damage. The damage index method is used on two numerical models; a cantilevered steel pipe and a simply-supported steel plate girder bridge. Torsion damage indices are compared to bending damage indices to assess their effectiveness at locating damage. The torsion strain energy method is capable of accurately locating damage and providing additional valuable information to both of the structures' behaviors.

Artificial Intelligence-based Leak Prediction using Pipeline Data (관망자료를 이용한 인공지능 기반의 누수 예측)

  • Lee, Hohyun;Hong, Sungtaek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.7
    • /
    • pp.963-971
    • /
    • 2022
  • Water pipeline network in local and metropolitan area is buried underground, by which it is hard to know the degree of pipe aging and leakage. In this study, assuming various sensor combinations installed in the water pipeline network, the optimal algorithm was derived by predicting the water flow rate and pressure through artificial intelligence algorithms such as linear regression and neuro fuzzy analysis to examine the possibility of detecting pipe leakage according to the data combination. In the case of leakage detection through water supply pressure prediction, Neuro fuzzy algorithm was superior to linear regression analysis. In case of leakage detection through water supply flow prediction, flow rate prediction using neuro fuzzy algorithm should be considered first. If flow meter for prediction don't exists, linear regression algorithm should be considered instead for pressure estimation.

Physical Properties of High Performance Multilayered PVC Pipe (고성능 다층 PVC pipe의 물성)

  • Shin, Yong-Jin;Ryang, Kyung-Seung;Kim, Sung-Hyun
    • Applied Chemistry for Engineering
    • /
    • v.10 no.5
    • /
    • pp.711-717
    • /
    • 1999
  • A multilayer-structure material containing ductile and brittle layer simultaneously was examined and compared with a single layer material using fracture mechanical properties. We found that impact strength of multilayer structure material was considerably higher than single layer's and toughness was enhanced by about two times or higher in similar glass transition temperature($T_g$) region and the same dimension. The superposition principle of impact pulse was used for interpretation of kinetic stress wave as a high-velocity crack proceeds in the plastic. It was understood that the optimum condition of ductile/brittle thickness ratio could be designed in the final toughness enhancement of multilayer.

  • PDF

Leak-Before-Break Assessment Margin Analysis of Improved SA508-Gr.1a Pipe Material (개선된 SA508-Gr.1a 배관재의 파단전누설평가 여유도 분석)

  • Kim, Maan-Won;Lee, Yo-Seob;Shin, In-Whan;Yang, Jun-Seog;Kim, Hong-Deok
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.1
    • /
    • pp.42-48
    • /
    • 2020
  • The effect of improving the tensile and J-R fracture toughness properties of SA508 Gr.1a on the LBB margin for the main steam pipe is investigated. The material properties and microstructure images of the existing main steam piping material SA106 Gr.C used in domestic nuclear power plants and the newly selected material SA508 Gr.1a were compared. For each material, LBB margins were calculated and compared through finite element analysis and crack instability evaluation. The LBB margin of the improved SA508 Gr.1a is found to be greatly improved compared to that of the existing SA106 Gr.C and SA508 Gr.1a. This is because of the increased material's strength and J-R fracture toughness compared to the previous materials. In order to analyze the effect of physical property change on the LBB margin, the sensitivity of each LBB margin according to the variation of tensile strength and J-R fracture toughness was analyzed. The effect of the change in tensile strength was found to be greater than that of the change in fracture toughness. Therefore, an increase in strength significantly influenced the improvement of the LBB margin of the improved SA508 Gr.1a.

Protection Performance Simulation of Coal Tar-Coated Pipes Buried in a Domestic Nuclear Power Plant Using Cathodic Protection and FEM Method (국내원전에 매설된 콜타르 코팅 배관의 음극방식과 FEM법을 이용한 방식성능 시뮬레이션)

  • Chang, H.Y.;Kim, K.T.;Lim, B.T.;Kim, K.S.;Kim, J.W.;Park, H.B.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.115-127
    • /
    • 2017
  • Coal tar-coated pipes buried in a domestic nuclear power plant have operated under the cathodic protection. This work conducted the simulation of the coating performance of these pipes using a FEM method. The pipes, being ductile cast iron have been suffered under considerably high cathodic protection condition beyond the appropriate condition. However, cathodic potential measured at the site revealed non-protected status. Converting from 3D CAD data of the power plant to appropriate type for a FEM simulation was conducted and cathodic potential under the applied voltage and current was calculated using primary and secondary current distribution and physical conditions. FEM simulation for coal tar-coated pipe without defects revealed over-protection condition if the pipes were well-coated. However, the simulation for coal tar-coated pipes with many defects predict that the coated pipes may be severely degraded. Therefore, for high risk pipes, direct examination and repair or renewal of pipes are strongly recommended.

Microbiological Contamination and Sanitary Management of Aquarium Water in the Busan Area

  • Cho, Kyung-Soon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.46 no.1
    • /
    • pp.1-11
    • /
    • 2014
  • This research has been performed by our own investigation, also cooperated with Health and Sanification Division and each of district offices in Busan metropolitan city. After choosing, we collected water samples five times for microbiological examination. As a result of investigating in 160 water samples from urban areas, we could detect 88 cases of Vibrio spp. Furthermore, there were four cases exceeding the acceptable limit of aquarium water (100,00/mL) and another four cases exceeding the limit of Coliform group (1,000 below/100 mL). As a result of investigating that we performed for 271 cases of water samples from coastal areas from April to November, we could detect 130 cases of vibrio species and 10 cases of Coliform group. After performing 17 kinds of antibiotic susceptibility test for 41 cases of isolated Vibrio parahaemolyticus, 27 cases showed tolerance to Amplicllin (AM), all of 31 cases showed intermediate resistance only to Cefazolin (CF) but had sensitivity to the rest of them. As a result of performing antibiotic susceptibility test, serum test and PFGE gene analysis on each 10 pair of Vibrio parahaemolyticus detected concurrently from intake-pipe water and, aquarium water, we couldn't get data showing that they are clearly same species in three kinds of test. In addition, UV sterilization, Ozonization and so on. Based on our research, intake pipe didn't have a problem with microbiological contamination so we are sure that the germ came from supplied fish had caused that kind of contamination. For effective management, UV sterilization or Ozonization which can be handled consistently should be adopted in aquarium.

Establishing Automated Mapping/Facilities Management System Using PC-CAD (PC용 CAD를 이용한 단지기반시설 정보화)

  • 이규석;안승만;탁형렬
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.15 no.2
    • /
    • pp.141-148
    • /
    • 1997
  • Continuous development of Personal Computer(PC) combined with the decrease of price and the expansion of operating system in PC like Windows 95, and Windows N/T makes it possible for the user to consider PC-bas-ed Automated Happing/Facilities Management (AM/FM) system. Therefore, the purpose of this study is to establish a PC-based data automation system of pipe infrastructures-water, sewer, and drainage-and road in Korea Land Corporation. In order to achieve this goal, relevant literature survey was done first. Secondly, the study site was determined by discussion with Korea Land Institute. Thirdly, PC-based CAD software for AM/FM in the world market were surveyed, and AutoCAD Map was selected because KLC had been using hundreds of AutoCAD copies already. After that user needs assessment was done to visit on-site office, local branch office, and the corresponding city office for the system design and database design. After the graphic data were digitized and the attribute data were entered into the batabase, the data automation system was established, and tested for application. Finally, the guidelines and problems for PC-based data automation in AM/FM was discussed.

  • PDF

The Effect of Turbulence Penetration on the Thermal Stratification Phenomenon Caused by Coolant Leaking in a T-Branch of Square Cross-Section

  • Choi, Young-Don;Hong, Seok-Woo;Park, Min-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.2
    • /
    • pp.51-60
    • /
    • 2003
  • In the nuclear power plant, emergency core coolant system (ECCS) is furnished at reactor coolant system (RCS) in order to cool down high temperature water in case of emergency. However, in this coolant system, thermal stratification phenomenon can occur due to coolant leaking in the check valve. The thermal stratification produces excessive thermal stresses at the pipe wall so as to yield thermal fatigue crack (TFC) accident. In the present study, effects of turbulence penetration on the thermal stratification into T-branches with square cross-section in the modeled ECCS are analysed numerically. Standard k-$\varepsilon$ model is employed to calculate the Reynolds stresses in momentum equations. Results show that the length and strength of thermal stratification are primarily affected by the leak flow rate of coolant and the Reynolds number of duct. Turbulence penetration into the T-branch of ECCS shows two counteracting effects on the thermal stratification. Heat transport by turbulence penetration from main duct to leaking flow region may enhance thermal stratification while the turbulent diffusion may weaken it.

A Study on the Decrease of the Unclamping time using Hydraulic Circuit (유압 회로를 이용한 초고속 스핀들의 언클램핑(unclamping) 시간 저감 방안 연구)

  • Chung W.J.;Lee C.M.;Cho Y.D.;Whang Y.K.;Chung D.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1745-1748
    • /
    • 2005
  • According to the demand of the high productivity, the interest of manufacturing skills is growing in industrial society. Especially the high speed spindle in machining center becomes important these days. The exchange time of the tool in machining center usually calls T-T(tool to tool) time. Detailly explaning, It is influenced by the unclamping time. Affecting factors of the unclamping time are various(the hydraulic system, drawbar mass, a flow meter, disc spring, a piston diameter, pipe diameters, and so on). In this study, we could find factors that decrease the unclamping time and verify it for softwares.(AMESim $4.0^{(R)}$ & visual Nastran $4D^{(R)}$)

  • PDF

Failure Assessment Diagrams of Semi-Elliptical Surface Crack with Constraint Effect (구속상태를 고려한 반타원 표면균열의 파손평가선도)

  • Seo, Heon;Han, Tae-Su;Lee, Hyeong-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.11 s.170
    • /
    • pp.2022-2032
    • /
    • 1999
  • In recent years, the subject of remaining life assessment has drawn considerable attention in the power generation industry. In power generation systems a variety of structural components, such as steam pipes, turbine rotors, and superheater headers, typically operate at high temperatures and high pressures. Thus a life prediction methodology accounting for fracture and rupture is increasingly needed for these components. For accurate failure assessment, in addition to the single parameter such as K or J-integral used in traditional fracture mechanics, the second parameter like T-stress describing the constraint is needed. The most critical defects in such structures are generally found in the form of semi-elliptical surface cracks in the welded piping-joints. In this work, selecting the structures of surface-cracked plate and straight pipe, we first perform line-spring finite element modeling, and accompanying elastic-plastic finite element analyses. We then present a framework for including constraint effects (T-stress effects) in the R6 failure assessment diagram approach for fracture assessment.