• Title/Summary/Keyword: T-F map

Search Result 103, Processing Time 0.024 seconds

Effect of MRI Media Contrast on PET/MRI (PET/MRI에 있어 MRI 조영제가 PET에 미치는 영향)

  • Kim, Jae Il;Kim, In Soo;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.19-25
    • /
    • 2014
  • Purpose: Integrated PET/MRI has been developed recently has become a lot of help to the point oncologic, neological, cardiological nuclear medicine. By using this PET/MRI, a ${\mu}-map$ is created some special MRI sequence which may be divided parts of the body for attenuation correction. However, because an MRI contrast agent is necessary in order to obtain an more MRI information, we will evaluate to see an effect of SUV on PET image that corrected attenuation by MRI with contrast agent. Materials and Methods: As PET/MRI machine, Biograph mMR (Siemens, Germany) was used. For phantom test, 1mCi $^{18}F-FDG$ was injected in cylinderical uniformity phantom, and then acquire PET data about 10 minutes with VIBE-DIXON, UTE MRI sequence image for attenuation correction. T1 weighted contrast media, 4 cc DOTAREM (GUERBET, FRANCE) was injected in a same phatnom, and then PET data, MRI data were acquired by same methodes. Using this PET, non-contrast MRI and contrast MRI, it was reconstructed attenuation correction PET image, in which we evanuated the difference of SUVs. Additionally, for let a high desity of contrast media, 500 cc 2 plastic bottles were used. We injected $^{18}F-FDG$ with 5 cc DOTAREM in first bottle. At second bottle, only $^{18}F-FDG$ was injected. and then we evaluated a SUVs reconstructed by same methods. For clinical patient study, rectal caner-pancreas cancer patients were selected. we evaluated SUVs of PET image corrected attenuastion by contrast weighted MRI and non-contrast MRI. Results: For a phantom study, although VIBE DIXON MRI signal with contrast media is 433% higher than non-contrast media MRI, the signals intensity of ${\mu}-map$, attenuation corrected PET are same together. In case of high contrast media density, image distortion is appeared on ${\mu}-map$ and PET images. For clinical a patient study, VIBE DIXON MRI signal on lesion portion is increased in 495% by using DOTAREM. But there are no significant differences at ${\mu}-map$, non AC PET, AC-PET image whether using contrast media or not. In case of whole body PET/MRI study, %diff between contras and non contrast MRAC at lung, liver, renal cortex, femoral head, myocardium, bladder, muscle are -4.32%, -2.48%, -8.05%, -3.14%, 2.30%, 1.53%, 6.49% at each other. Conclusion: In integrated PET/MRI, a segmentation ${\mu}-map$ method is used for correcting attenuation of PET signal. although MRI signal for attenuation correciton change by using contrast media, ${\mu}-map$ will not change, and then MRAC PET signal will not change too. Therefore, MRI contrast media dose not affect for attenuation correction PET. As well, not only When we make a flow of PET/MRI protocol, order of PET and MRI sequence dose not matter, but It's possible to compare PET images before and after contrast agent injection.

  • PDF

Investigation of light stimulated mouse brain activation in high magnetic field fMRI using image segmentation methods

  • Kim, Wook;Woo, Sang-Keun;Kang, Joo Hyun;Lim, Sang Moo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.12
    • /
    • pp.11-18
    • /
    • 2016
  • Magnetic resonance image (MRI) is widely used in brain research field and medical image. Especially, non-invasive brain activation acquired image technique, which is functional magnetic resonance image (fMRI) is used in brain study. In this study, we investigate brain activation occurred by LED light stimulation. For investigate of brain activation in experimental small animal, we used high magnetic field 9.4T MRI. Experimental small animal is Balb/c mouse, method of fMRI is using echo planar image (EPI). EPI method spend more less time than any other MRI method. For this reason, however, EPI data has low contrast. Due to the low contrast, image pre-processing is very hard and inaccuracy. In this study, we planned the study protocol, which is called block design in fMRI research field. The block designed has 8 LED light stimulation session and 8 rest session. All block is consist of 6 EPI images and acquired 1 slice of EPI image is 16 second. During the light session, we occurred LED light stimulation for 1 minutes 36 seconds. During the rest session, we do not occurred light stimulation and remain the light off state for 1 minutes 36 seconds. This session repeat the all over the EPI scan time, so the total spend time of EPI scan has almost 26 minutes. After acquired EPI data, we performed the analysis of this image data. In this study, we analysis of EPI data using statistical parametric map (SPM) software and performed image pre-processing such as realignment, co-registration, normalization, smoothing of EPI data. The pre-processing of fMRI data have to segmented using this software. However this method has 3 different method which is Gaussian nonparametric, warped modulate, and tissue probability map. In this study we performed the this 3 different method and compared how they can change the result of fMRI analysis results. The result of this study show that LED light stimulation was activate superior colliculus region in mouse brain. And the most higher activated value of segmentation method was using tissue probability map. this study may help to improve brain activation study using EPI and SPM analysis.

A REMARK ON INVARIANCE OF QUANTUM MARKOV SEMIGROUPS

  • Choi, Ve-Ni;Ko, Chul-Ki
    • Communications of the Korean Mathematical Society
    • /
    • v.23 no.1
    • /
    • pp.81-93
    • /
    • 2008
  • In [3, 9], using the theory of noncommutative Dirichlet forms in the sense of Cipriani [6] and the symmetric embedding map, authors constructed the KMS-symmetric Markovian semigroup $\{S_t\}_{t{\geq}0}$ on a von Neumann algebra $\cal{M}$ with an admissible function f and an operator $x\;{\in}\;{\cal{M}}$. We give a sufficient and necessary condition for x so that the semigroup $\{S_t\}_{t{\geq}0}$ acts separately on diagonal and off-diagonal operators with respect to a basis and study some results.

ITERATIVE SOLUTION OF NONLINEAR EQUATIONS WITH STRONGLY ACCRETIVE OPERATORS IN BANACH SPACES

  • Jeong, Jae-Ug
    • Journal of applied mathematics & informatics
    • /
    • v.7 no.2
    • /
    • pp.605-615
    • /
    • 2000
  • Let E be a real Banach space with property (U,${\lambda}$,m+1,m);${\lambda}{\ge}$0; m${\in}N$, and let C be a nonempty closed convex and bounded subset of E. Suppose T: $C{\leftrightarro}C$ is a strongly accretive map, It is proved that each of the two well known fixed point iteration methods( the Mann and Ishikawa iteration methods.), under suitable conditions , converges strongly to a solution of the equation Tx=f.

GENERALIZED COMPOSITION OPERATORS FROM GENERALIZED WEIGHTED BERGMAN SPACES TO BLOCH TYPE SPACES

  • Zhu, Xiangling
    • Journal of the Korean Mathematical Society
    • /
    • v.46 no.6
    • /
    • pp.1219-1232
    • /
    • 2009
  • Let H(B) denote the space of all holomorphic functions on the unit ball B of $\mathbb{C}^n$. Let $\varphi$ = (${\varphi}_1,{\ldots}{\varphi}_n$) be a holomorphic self-map of B and $g{\in}2$(B) with g(0) = 0. In this paper we study the boundedness and compactness of the generalized composition operator $C_{\varphi}^gf(z)=\int_{0}^{1}{\mathfrak{R}}f(\varphi(tz))g(tz){\frac{dt}{t}}$ from generalized weighted Bergman spaces into Bloch type spaces.

A Note on S-closed Space and RC-convergence. (S-closed 공간(空間)과 RC 수렴(收斂)에 관하여)

  • Han, Chun-Ho
    • Journal of Industrial Technology
    • /
    • v.5
    • /
    • pp.47-49
    • /
    • 1985
  • Semi-open을 기초로 하여 만들어진 S-closed 공간의 일반적인 성질을 살펴보고 S-closed 공간과 (maximum) filterbase와의 관계를 조사하였다. 이를 바탕으로 regular closed된 cover C, regular open set인 족(族) C, rc-accumulation, (maximum) filterbase에서의 관계(關係)를 살펴 보았다. Mapping theory에서 almost-open almost-continuous map f가 almost continuous되는 것을 보였다.

  • PDF

ON SOME PROPERTIES OF THE BLASS TOPOS

  • Kim, Ig-Sung
    • The Pure and Applied Mathematics
    • /
    • v.2 no.1
    • /
    • pp.25-29
    • /
    • 1995
  • The topos constructed in [6] is a set-like category that includes among its axioms an axiom of infinity and an axiom of choice. In its final form a topos is free from any such axioms. Set$\^$G/ is a topos whose object are G-set Ψ$\sub$s/:G${\times}$S\longrightarrowS and morphism f:S \longrightarrowT is an equivariants map. We already known that Set$\^$G/ satisfies the weak form of the axiom of choice but it does not satisfies the axiom of the choice.(omitted)

  • PDF

ISHIKAWA AND MANN ITERATION METHODS FOR STRONGLY ACCRETIVE OPERATORS

  • JONG YEOUL PARK;JAE UG JEONG
    • Communications of the Korean Mathematical Society
    • /
    • v.13 no.4
    • /
    • pp.765-773
    • /
    • 1998
  • Let E be a smooth Banach space. Suppose T : E longrightarrow E is a strongly accretive map. It is proved that each of the two well known fixed point iteration methods (the Mann and Ishikawa iteration methods), under suitable conditions, converges strongly to a solution of the equation Tx = f.

  • PDF

Development of magnetocardiograph system using YBCO SQUID magnetometers (YBCO SQUID 자력계를 이용한 자기심장검사장치 개발)

  • Kim, I.S.;Oh, S.H.;Lim, H.K.;Lee, Y.H.;Lee, S.G.;Park, Y.K.
    • Progress in Superconductivity
    • /
    • v.8 no.2
    • /
    • pp.158-163
    • /
    • 2007
  • YBCO do superconducting quantum interference device (SQUID) magnetometers based on bicrystal junctions have been fabricated for magnetocardiograph (MCG) measurements. We could fabricate YBCO SQUID magnetometers having magnetic field noise of about $20fT/Hz^{1/2}$ at white noise region. We have developed an MCG system employing the high performance SQUID magnetometers. The lightweight MCG system, requiring liquid nitrogen as a coolant, consists of 6-channel SQUID sensors, an adjustable patient bed with sliding motion, and data analyses software. The MCG system could record quite clear MCG signals in a room with moderate magnetic shielding. In normal operation with multi-position MCG measurements, we could obtain clear 48-point mappings of magnetic field map and current source map with high enough signal qualities far clinical trials.

  • PDF

Interpretation of Adaptational Environment of the genus Trapa in Korea Through peat deposit

  • Lee, Jin-Hee;Kim, Dae-Jae
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.1
    • /
    • pp.69-80
    • /
    • 2015
  • Studies on Trapa of Korean, Japanese, and Chinese origins have been generally limited to currently living Trapa, thereby demonstrating the lack of phylogenetic approaches. In the present study, we conducted a numerical taxonomic study on 34 Korean origin Trapa species newly discovered in peat deposits. By using the numerical taxonomy as well as geological data, we created an appearance map based on the periods and taxonomic groups of the Korean Trapa. Further, by using this appearance map, we reviewed the limitations that exist in the taxa and simultaneously discussed the adaptational environment of Trapa in each period. Although other studies have discussed new variants of Trapa worldwide, including T. litwinowii V. vassil. var. chihuensis S.F.Guan & Q.Lang of China (Guan and Lang, 1987), the present study is significant because it provides data on the origin of Korean Trapa species. The availability of such data is essential in determining the adaptational environment of the presently living Trapa. To our knowledge, this is the first report of approximately 10 newly discovered and other presently living species of Trapa. Further, the appearance map in the present study allows the use of the 10 newly discovered species and variants of 34 Trapa species indigenous to South Korea for over 1000 years, for a comparison with the currently living Trapa species. Thus, the present study results could serve as important basic data to understand the adaptational environment of the genus Trapa. from the past to the present in Korea.