• Title/Summary/Keyword: T-DOC

Search Result 69, Processing Time 0.025 seconds

Evaluation of Pollutant Load Unit Factor for Calculating Pollutants Emission in Aquacultural Farms (양식계 오염원 배출량 산정을 위한 원단위 설정)

  • Park, Jae Hong;Park, Bae Kyoung;Rhew, Doug Hee;Lee, Jae Kwan
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.5
    • /
    • pp.656-665
    • /
    • 2013
  • This research was conducted to investigate pollutant load unit factor from aquacultural farms. Pollutant load unit factors were investigated on the 13 kinds of fish type, i.e., Trout, Leather Carp, Eel, Carp, Cartfish, Freshwater Eel, Crucian Carp, Colored Carp, Sturgeon, Marsh Snail, Sweetfish, Pond Snail, Eriocheir Sinensis. Water qualities in aquacultural farms were investigated wide range of values by fish type and pollutant items. High BOD and COD values were observed at the Leather Carp (Ponded water system), Cartfish (Ponded water system) and Freshwater Eel (Recirculating System). TOC and DOC values were relatively high at the Freshwater Eel (Recirculating System) and Eriocheir Sinensis (Extensive). Eel (Ponded water system) and Freshwater Eel (Recirculating System) produced high concentrated nutrient pollutants, i.e., T-N, T-P. Pollutant load unit factors are dependent on fish type, aquacultural type, water quality items, etc. If some fishes have similar basic unit values, those could be applied for TMDLs as a group of fish having same pollutant load unit. The water quality concentrations of post treatment facilities' (mainly reservoir tank) effluent were higher than those of fish raising bath because of extracting pollutant from sediment in the reservoir tank. Therefore, it needs to the management and regulations about post treatment facilities.

First-flush Runoff Characteristics of NPS from golf course (골프장에서 발생하는 비점오염원의 초기유출수 특성)

  • Shin, Min-Hwan;Choi, Jae-Wan;Choi, Yong-Hun;Seo, Ji-Yeon;Lee, Jae-Woon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1129-1133
    • /
    • 2010
  • 본 연구에서는 수질오염총량제와 정책제안의 원활하고 합리적인 추진을 위해 토지피복분류체계의 대분류중 초지에 해당하고 중분류 중 골프장에 해당하는 지점을 선정하여 강우에 의해 발생하는 비점오염물질의 유출특성을 분석하였다. 연구기간 동안 총 27번의 강우사상으로 인해 발생하는 강우유출수에 대하여 유량과 수질농도를 측정하였다. 유량측정은 웨어를 통한 수위를 측정하여 유량으로 환산하였고, 수질항목은 $BOD_5$, $COD_{Mn}$, DOC, SS, T-N, T-P, $NH_3$-N, $NO_3$-N, $PO_4$-P 등 9개 항목을 분석하였다. 분석된 결과를 이용하여 골프장에서 발생하는 비점오염원의 초기세척효과 발생여부를 판단하기 위하여 누적오염부하량/누적유출량 그래프를 도식화하였다. 연구기간동안 발생한 5~82 mm의 강우로 인해 6.6~2,082 $m^3$의 유출이 발생하였다. 발생된 유출수의 농도는 $BOD_5$ 1.8~11.3 mg/L, $COD_{Mn}$ 19.2~51.4 mg/L, DOC 11.0~31.0 mg/L, SS 2.2~57.3 mg/L, T-N 1.545~16.098, T-P 0.230~4.528 mg/L, $NH_3$-N 0.076~5.285 mg/L, $NO_3$-N 0.122~2.905 mg/L, $PO_4$-P 0.005~2.631 mg/L로 나타났다. 초기유출수의 세척효과는 27번의 강우사상동안 SS 항목의 경우 17번, $NO_3$-N 11번, $NH_3$-N 4번 등이 발생하였다. 초기세척효과가 발생한 강우사상은 초기의 오염원 농도가 중 후반 농도보다 농도가 높음을 의미하므로, 골프장에서 발생하는 강우유출수는 초기에 발생하는 오염원에 초점을 두고 처리방안을 모색해야 할 것으로 판단된다. 또한 SS와 질소계열의 농도가 높은 것은 골프장의 잔디관리를 위한 농약이나 제초제 등의 사용과 토양유실이 원인인 것으로 판단되며, 이를 저감하기 위한 적절한 사용방안과 저감대책이 필요할 것으로 판단된다.

  • PDF

Characteristics of distribution and decomposition of organic matters in stream water and sewage effluent (하천수와 하수처리장 방류수의 유기물 분포 및 분해 특성)

  • Seo, Hee-Jeong;Kang, Yeoung-Ju;Min, Kyoung-Woo;Lee, Kyoung-Seog;Seo, Gwang-Yeob;Kim, Seung-Ho;Paik, Kye-Jin;Kim, Seong-Jun
    • Analytical Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.36-44
    • /
    • 2010
  • This study was performed to investigate the distribution and decomposition characteristics of organic matter in stream water and sewage effluent located in Gwangju. Average of dissolved organic carbon (DOC) to total organic carbon (TOC) ratio was approximately 73.9% in the Youngsan river system. The concentration of refractory dossolved carbon (RDOC) was 3.7 mg/L corresponding to 80.9% of the DOC. The ratio of recalcitrant organic carbon was relatively higher than that of biodegradable organic carbon in stream. Oxidation efficiencies in the stream were 45.0% for BOD, 63.0% for $COD_{Mn}$ and 106.5% for CODcr. In case of sewage effluent was 33.6%, 65.7% and 136.1% respectively. Mean decomposition rate ($K_d$) of Youngsan river mainstream, its tributary sites and sewage effluent were about $0.042\;day^{-1}$, $0.043\;day^{-1}$ and $0.028\;day^{-1}$, respectively and the difference was not significant between the mainstream and its tributary sites (t-test, p>0.05). $K_d$ of the sewage effluent was lower than that of stream water.

Improvement of Emission Performance in a 3.3 Liter DI Diesel Engine by Using Dimethyl Ether Fuel (디메틸에테르 연료를 사용하는 3.3리터 디젤기관의 배기성능 개선)

  • Pyo, Young-Dug;Lee, Young-Jae;Kim, Mun-Heon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.4
    • /
    • pp.178-185
    • /
    • 2007
  • A study is improvement of power and emission in a inline-pump Dr diesel engine by using Dimethyl ether Fuel. Dimethyl ether (DME) is an oxygenated fuel with a cetane number higher than that of diesel oil. It meets the ULEV emission regulation and reduces the smoke to almost zero when used in a diesel engine. But NOx emission is almost same and CO, THC emissions are lower than that of diesel engine. The emissions aren't satisfied the stronger emission regulation in the further. Generally DOC (Diesel Oxidation Catalyst) is used to reduce CO & THC emissions and EGR (Exhaust Gas Recirculation) system is used to reduce NOx emission. Test results showed that the torque and the power with DME were almost same as those of pure diesel oil, but the brake thermal efficiency increased a little. also the BSEC (Brake Specific Energy Consumption) with DME was similar that of diesel. The test results showed that the DOC was the vary effective method to reduce the CO emission in case of Dimethyl Ether Fuel in diesel engine. But, THC emission is showed a little reduction rates. Also EGR system was the very effective method to reduce the NOx emission in case of Dimethyl Ether Fuel in diesel engine.

OXIDATION CHARACTERISTICS OF PARTICULATE MATTER ON DIESEL WARM-UP CATALYTIC CONVERTER

  • Choi, B.C.;Yoon, Y.B.;Kang, H.Y.;Lim, M.T.
    • International Journal of Automotive Technology
    • /
    • v.7 no.5
    • /
    • pp.527-534
    • /
    • 2006
  • Modern passenger cars with diesel engines are equipped with DOC(diesel oxidation catalyst) for the purpose of reducing HC and CO in the exhaust stream. Cold start exhaust emissions pose troubles here as on gasoline engine vehicles. As a result, some of the diesel passenger cars roll off todays the assembly lines with WCC(warm-up catalytic converter). Oxidation characteristics of the particulates in WCC is analyzed in this study by EEPS(engine exhaust particulate size spectrometer). The maximum number of PM is found to come out of WCC in sizes near 10nm when an HSDI diesel engine is operated under the conditions of high speed and medium to heavy load. When the temperature of the WCC exceeds $300^{\circ}C$, the number of PM smaller than 30 nm in diameter sharply increases upon passing through the WCC. Total mass of emitted PM gets reduced downstream of the WCC under low speed and light load conditions due to adsorption of PM onto the catalyst. Under conditions of high speed and medium to heavy load, the relatively large PM shrink or break into fine particles during oxidation process within the WCC, which results in more mass fraction of fine particles downstream of the WCC.

A Study on the Service Improvement Strategies by Enterprise through the Analysis of Customer Response Reviews in Smart Home Applications : Based on the Classification of Functional Elements and Design Elements of smart Home Usability Values (스마트 홈 어플리케이션의 고객반응리뷰분석을 통한 기업별 서비스개선전략에 대한 연구 : 스마트 홈 사용성 가치의 기능적요소와 디자인적 요소 분류를 바탕으로)

  • Heo, Ji Yeon;Kim, Min Ji;Cha, Kyung Jin
    • Journal of Information Technology Services
    • /
    • v.19 no.4
    • /
    • pp.85-107
    • /
    • 2020
  • The Internet of Things market, a technology that connects the Internet to various things, is growing day by day. Besides, various smart home services using IoT and AI (Artificial Intelligence) are being launched in homes. Related to this, existing smart home-related studies focus primarily on ICT technology, not on what service improvements should be made in customer positions. In this study, we will use smart home application customer review data to classify functional and design elements of smart home usability value and examine the ways customers think of service improvement. For this, LG Electronics and Samsung Electronics" Smart Home application, the main provider of Smart Home in Korea, customer reviews were crawled to conduct a comparative analysis between them. In this study, the review of IoT home-applications was analyzed to find service improvement insights from customer perspective, and related analysis of text mining, social network analysis and Doc2vec was used to efficiently analyze data equivalent to about 16,000 user reviews. Through this research, we hope that related companies effectively seek ways to improve smart home services that reflect customer needs and are expected to help them establish competitive strategies by identifying weaknesses and strengths among competitors.

Biogeochemical Reactions in Hyporheic Zone as an Ecological Hotspot in Natural Streams (자연 하천의 생태학적 중요 지점으로서 지표수-지하수 혼합대의 생지화학적 기작)

  • Kim, Young-Joo;Kang, Ho-Jeong
    • Journal of Wetlands Research
    • /
    • v.11 no.1
    • /
    • pp.123-130
    • /
    • 2009
  • Hyporheic zone is an area where hydraulic exchanges occur between surface water and ground water. Such transient area is anticipated to facilitate diverse biogeochemical reactions by providing habitats for various microorganism. However, only a few data are available about microbial properties in hyporheic zone, which would be important in better understanding of biogeochemical reactions in whole streams. The study site is Naesung stream, located in the north Kyoung-Sang Province, of which sediment is sandy with little anthropogenic impacts. Soil samples were collected from a transect placed perpendicular to stream flow. The transect includes upland fringe area dominated by Phragmites japonica, bare soil, and soil adjacent to water. In addition, soil samples were also collected from downwelling and upwelling areas in hyporheic zone within the main channel. Soils were collected from 3 depth in each area, and water content, pH, and DOC were measured. Various microbial properties including extracellular enzyme activities ($\beta$-glucosidase, N-acetylglucosaminidase, phosphatase and arylsulfatase), and microbial community structure using T-RFLP were also determined. The results exhibited a positive correlation between water content and DOC, and between extracellular enzyme activities and DOC. Distinctive patterns were observed in soils adjacent to water and hyporheic zone compared with other soils. Overall results of study provided basic information about microbial properties of hyporheic zone, which appeared to be discernable from other locations in the stream corridor.

  • PDF

Evaluation of Basic Unit for Non-point Pollutants in Runoff of West Coast Highway - Maesong Area (서해안 고속도로 매송지역 비점오염원 원단위 산정 연구)

  • Park, Seyong;Mo, Kyung;Kim, Leehyung;Kang, Heeman;Kim, Moonil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.8
    • /
    • pp.33-40
    • /
    • 2010
  • In this study, evaluation of basic unit of non-point pollutant, which is fundamental evaluation of non-point loading, was conducted using both road point and angle of intersection point in Maesong area, West coast highway by utilizing Event Mean Concentrations(EMC). Concentration of pollutants except heavy metals at these two points rapidly decreased in 30 minutes after start of runoff. According to the results of EMC, for both sampling points, it was determined that the concentrations of TSS(Total Suspended Solid), $BOD_5$(Biological Oxygen Demand), and DOC(Dissolved Organic Carbon) were higher than those of wastewater effluent standard in Korea, however, the concentrations of T-N(Total Nitrogen) and T-P(Total Phosphorus) were lower than those of the standard. In terms of heavy metals, Fe, Pb, and Zn showed higher concentrations than others. When compared with the units established by the Ministry of Environment in Korea, the basic units of $BOD_5$ and T-N in this study were lower. On the other hand, when compared with foreign units, Cu, Pb, and Zn showed approximately 10 times higher concentrations. It was estimated that a long term monitoring should be conducted for obtaining additional data and more reliable basic units for the non-point pollutnats based on the results from this study.

Removal Characteristics of Natural Organic Matter and Taste and Odor by Advanced Water Treatment Process around the Han River Water Supply System (한강수계 고도정수처리 공정에서의 유기물과 맛·냄새의 제거특성)

  • Jae-Lim Lim;Lee, Kyung-Hyuk;Kim, Seong-Su;Chae, Seon-Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.1
    • /
    • pp.13-25
    • /
    • 2007
  • The water treatment plants in Seoul Metropolitan Area, which are under Korea Water Resources Corporation(KOWACO)'s management, take water from Paldang Reservoir in Han River System for drinking water supply. There are taste and odor (T&O) problems in the finished water because the conventional treatment processes do not effectively remove the T&O compounds. As part of countermeasures for taste and odor control, KOWACO is planning to introduce advanced water treatment process such as ozone and GAC in near future. This study evaluated the removal characteristics of T&O and dissolved organic matter (DOM) to find design and operation parameters of advanced water treatment processes in a pilot-scale treatment plant. The GAC adsorption capacity for DOC in the two GAC system (GAC and $O_3$-GAC) at an EBCT of 14min was mostly exhausted after 9months. The differency of the removal efficiency of DOC between $O_3$-GAC and GAC increased with increasing operation time because the bioactivity in $O_3$-GAC process was enhanced by post-ozone process. Removal by conventional treatment was unable to reach the target TON(threshold odor number) of 3 but GAC systems at an EBCT(empty bed contact time) of 14 min were able to archive the target with few exception. During the high T&O episodes, PAC as a pretreatment together with GAC could be useful option for T&O control. However, substantial TON removal continued for more than two year (> 90,000 bed volumes). At the spiking of less concentration 26 to 61 ng/L in the influent of GAC systems, GAC absorber and $O_3$-GAC processes could meet the treatment target. The better spike control after 12 and 19 months of operation compared to that after 7 months of operation is a strong indication of biological control. The results presented in this study had shown that $O_3$-GAC process was found to be more effective for T&O control than GAC process. And the main removal mechanism in GAC systems were adsorption capacity and biodegradation.

A Study on Classification Support Expert System Design based on Note Analysis for DDC 20 Tables (DDC 20판의 주기 분석에 근거한 보조표 분류지원 전문가시스템 설계에 관한 연구)

  • 김상미;남태우
    • Proceedings of the Korean Society for Information Management Conference
    • /
    • 1994.12a
    • /
    • pp.129-132
    • /
    • 1994
  • DOC 20판에서는 보조표 활용을 위하여 다양한 형태의 주기(Note)가 여러 곳에 마련되어 있다. 이 주기는 새로운 학문들이 이전판의 분류체재와의 중복성을 극복하고, 정확한 문헌분류를 위한 중요한 문법규칙들을 포함하고 있다. 그러나. 기술된 주기의 다양성이 제대로 정리되어 있지 않아서 이 주기의 활용은 미흡한 실정이다. 따라서, 본 연구는 DDC 20판의 보조표 T1(표준세분표: Standard Subdivisions) 및 T2(지리, 시대, 인물 구분표: Geographic Areas, Historical Periods, Persons)에 대안 이용주기를 통계적 빈도수를 고려하여 분석하고, 분석된 주기를 유형별로 분류하여 각 유형별 분류기호 생성 문법을 마련하였으며, 분류기호 생성 문법을 유도트리(Derivation tree)를 활용하여 정확한 분류과정을 예시하고, 이를 자동분류시스템으로 활용할 수 있는 분류진원 전문가시스템 모형을 설계하였다.

  • PDF