• 제목/요약/키워드: T detector

검색결과 431건 처리시간 0.027초

Detector Mount Design for IGRINS

  • Oh, Jae Sok;Park, Chan;Cha, Sang-Mok;Yuk, In-Soo;Park, Kwijong;Kim, Kang-Min;Chun, Moo-Young;Ko, Kyeongyeon;Oh, Heeyoung;Jeong, Ueejeong;Nah, Jakyoung;Lee, Hanshin;Jaffe, Daniel T.
    • Journal of Astronomy and Space Sciences
    • /
    • 제31권2호
    • /
    • pp.177-186
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is a near-infrared wide-band high-resolution spectrograph jointly developed by the Korea Astronomy and Space Science Institute and the University of Texas at Austin. IGRINS employs three HAWAII-2RG Focal Plane Array (H2RG FPA) detectors. We present the design and fabrication of the detector mount for the H2RG detector. The detector mount consists of a detector housing, an ASIC housing, a Field Flattener Lens (FFL) mount, and a support base frame. The detector and the ASIC housing should be kept at 65 K and the support base frame at 130 K. Therefore they are thermally isolated by the support made of GFRP material. The detector mount is designed so that it has features of fine adjusting the position of the detector surface in the optical axis and of fine adjusting yaw and pitch angles in order to utilize as an optical system alignment compensator. We optimized the structural stability and thermal characteristics of the mount design using computer-aided 3D modeling and finite element analysis. Based on the structural and thermal analysis, the designed detector mount meets an optical stability tolerance and system thermal requirements. Actual detector mount fabricated based on the design has been installed into the IGRINS cryostat and successfully passed a vacuum test and a cold test.

스마트 홈에서 연소에 따른 화재감지기 원격 IoT 작동 시간에 관한 연구 (A Study on Remote IoT operating time for Fire Detector of Smart Home)

  • 고은영;홍성호;차재상
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권2호
    • /
    • pp.235-238
    • /
    • 2020
  • 스마트홈 시대에 화재안전은 인명 및 시설안전에 매우 중요한 사항이다. 화재로 인한 사상자 및 재산상 피해는 국가적으로 큰 손실일 것이다. 본 논문에서는 스마트홈에서 화재에 따라 화재감지기 작동시간을 판단하여 위험성을 예측할 수 있도록 제안하고자 한다. IoT 화재감지기인 열감지기와 연기감지기 중에서 화재에 따라 작동하는 시간의 차이로 인하여 위험성을 예측을 할 수 있다. 본 실험결과를 바탕으로 이온식 연기감지기가 매우 빠른 특성을 보여 추후 화재예방시설시에 본 결과물이 잘 활용되면 좋을 것이다.

Application of an Energy Sensitive CZT Detector to a DXA Type of Bone Densitometer

  • Yoon, Je-Woong;Lee, Hyung-Koo;Lee, Heung-Kyu
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.422-424
    • /
    • 2002
  • The accuracy of DXA(Dual Energy X-ray Absorptiometry) highly depends on the detection and separation capability of dual energy X-ray X-ray photons. In addition both of scan time and patient exposure are affected by detection efficiency. A CZT detector with a good energy resolution and high detection efficiency was evaluated for the application of bone densitometry. Its performance was compared to a photomultiplier tube with a NaI(T1) scintillator in terms of energy resolution, detection efficiency and the accuracy of bone mineral density measurement. The comparison study was performed with CZT detector and PM tube using DXA equipments(OSTEO Plus, OSTEO Prima, ISOL Technology). The energy spectrum was acquired using MCA(Multi-Channel Analyzer). The used X-ray energy ranged from 20keV to 86keV. The MCA result of the CZT detector showed a slightly sharper energy spectrum than that of NaI(T1). Detection efficiency of the CZT detector at 59.5keV was 1.4 times better. Remarkably the final results of bone mineral density measurements demonstrate only less than 1% difference. The CZT detector appears to have many benefits for the application of bone densitometry. Its excellent energy resolution can enhance the counting accuracy of dual energy X-ray spectrum. Furthermore its compactness in physical dimension and no cooling requirement will be additional benefits for a more compact and accurate bone densitometer.

  • PDF

Feasibility study of multiplexing method using digital signal encoding technique

  • Kim, Kyu Bom;Leem, Hyun Tae;Chung, Yong Hyun;Shin, Han-Back
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2339-2345
    • /
    • 2020
  • Radiation imaging systems consisting of a large number of channels greatly benefit from multiplexing methods to reduce the number of channels with minimizing the system complexity and development cost. In conventional pixelated radiation detector modules, such as anger logic, is used to reduce a large number of channels that transmit signals to a data acquisition system. However, these methods have limitations of electrical noise and distortion at the detector edge. To solve these problems, a multiplexing concept using a digital signal encoding technique based on a time delay method for signals from detectors was developed in this study. The digital encoding multiplexing (DEM) method was developed based on the time-over-threshold (ToT) method to provide more information including the activation time, position, and energy in one-bit line. This is the major advantage of the DEM method as compared with the traditional ToT method providing only energy information. The energy was measured and calibrated by the ToT method. The energy resolution and coincidence time resolution were observed as 16% and 2.4 ns, respectively, with DEM. The position was successfully distributed on each channel. This study demonstrated the feasibility that DEM was useful to reduce the number of detector channels.

A Monochromatic X-Ray CT Using a CdTe Array Detector with Variable Spatial Resolution

  • Tokumori, Kenji;Toyofuku, Fukai;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.411-414
    • /
    • 2002
  • The CdTe semiconductor detector has a higher detection efficiency for x-rays and $\square$amma rays and a wider energy band gap compared with Si and Ge semiconductor detectors. Therefore, the size of the detector element can be made small, and can be operated at room temperature. The interaction between a CdTe detector and incident x-rays is mainly photoelectric absorption in the photon energy range of up to 100 keV. In this energy range, Compton effects are almost negligible. We have developed a 256 channel CdTe array detector system for monochromatic x-ray CT using synchrotron radiation. The CdTe array detector system, the element size of which is 1.98 mm (h) x 1.98 mm (w) x 0.5 mm (t), was operated in photon counting mode. In order to improve the spatial resolution, we tilted the CdTe array detector against the incident parallel monochromatic x-ray beam. The experiments were performed at the BL20B2 experimental hutch in SPring-8. The energy of incident monochromatic x-rays was set at 55 keV. Phantom measurements were performed at the detector angle of 0, 30 and 45 degrees against the incident parallel monochromatic x-rays. The linear attenuation coefficients were calculated from the reconstructed CT images. By increasing the detector angle, the spatial resolutions were improved. There was no significant difference between the linear attenuation coefficients which were corrected by the detector angle. It was found that this method was useful for improving the spatial resolution in a parallel monochromatic x-ray CT system.

  • PDF

지점검지기 신뢰도 비교를 통한 대표치 생성 개선방안 : 구간 교통량을 중심으로 (Improvement of Representative Value through Comparison of the Reliability of point detector : focusing on traffic volume)

  • 최윤혁;이윤석
    • 한국ITS학회 논문지
    • /
    • 제12권5호
    • /
    • pp.22-35
    • /
    • 2013
  • 본 논문은 영상검지기 증가에 따라 교통정보 신뢰도에 대한 우려가 높아지고 있는 바, 지점검지기 데이터 분석을 통해 신뢰도가 높은 대표 구간 교통량 생성방법을 제안하였다. 이를 위해 고속도로를 대상으로 영상과 루프 검지기에서 각각 수집된 교통량 차이를 비교분석하고 통계적으로 검증하였으며, 실측교통량과의 오차율을 분석하였다. 분석 결과, 영상검지기와 루프검지기에서 각각 수집된 교통량은 동일 구간, 동일한 시간대에 수집된 자료라도 차이가 있었으며, 이는 통계적으로 유의하였다. 또한 루프검지기에서 수집된 교통량이 실측교통량과의 가장 차이가 적어, 대표 구간 교통량 생성 시 루프 및 영상 교통량을 평균하는 현재의 방법보다 영상검지기보다 신뢰도가 높은 루프 검지기 자료를 대표치로 이용하는 방법을 제안하였다. 이는 다양한 신뢰도를 보이는 많은 데이터를 이용하여 대표치를 생성하는 것보다, 하나라도 보다 신뢰성이 높은 데이터를 대표치로 이용하는 것이 훨씬 양질의 데이터를 생성할 수 있음을 보여준다. 다만, 루프검지기라고 할지라도 유지관리 및 기타 다양한 요소에 의해 신뢰도가 저하될 수 있으므로 검지기 상태에 대한 검증과 평가는 반드시 전제되어야 한다.

Analysis of Cationic Surfactants in Cosmetics By Reverse phase Ion-Pair Chromatigraphy with Suressed Conductivity Detector and UV Detector

  • Jong-Keun Choi;Jae
    • 대한화장품학회지
    • /
    • 제23권3호
    • /
    • pp.161-167
    • /
    • 1997
  • Determination of several cationic surfactants in cosmetics has been investigated. Reverse phase ion pair chromatography was used to identify and quantitate cationic surfactants. Cationic surfactants analyzed in this experiment were cetylpyridium chloride, stearyltrimetylammonium chloride, bezalkonium chloride, benzyldicethylcetylammonium chloride, and bihenyltrimethyl ammonium chloride. The separation was achieved on a reverse phase coumn with 10mM HCl-acetonitrile eluent. In this condition, the most of cationic surfactants with exception of CPC and CTAC respectively with suppressed conductivity detector and UV detector connected in series. The calibration curves obtained by plotting the peak areas of the cationic surfactants were linear at levels ranging from 0.005 to 0.1% correlation coefficient, r=0.9988. The detection limits were 1 to 5ppm in sample solution. The average recoveries of cationic surfactants added to hair treatment cream and hair rinse in three to five experiments were 96.7 105.2% and relative standard deviations were 1.1-3.8%. The case that there were CPC and CTAC in same solution was also tested. CPC and CTAC which couldn't be separated on reverse phase column were quantitated with suppressed conductivity detector and UV detector connected in series. Recovery of CPC and CTAC were 101.6 and 89.2% respectively. The proposed method was applied to the determination of cationic surfactants in commercial hair treatment cream.

  • PDF

MEASUREMENT OF THE D-D NEUTRON GENERATION RATE BY PROTON COUNTING

  • Kim, In-Jung;Jung, Nam-Suk;Choi, Hee-Dong
    • Nuclear Engineering and Technology
    • /
    • 제40권4호
    • /
    • pp.299-304
    • /
    • 2008
  • A detection system was set up to measure the neutron generation rate of a recently developed D-D neutron generator. The system is composed of a Si detector, He-3 detector, and electronics for pulse height analysis. The neutron generation rate was measured by counting protons using the Si detector, and the data was crosschecked by counting neutrons with the He-3 detector. The efficiencies of the Si and He-3 detectors were calibrated independently by using a standard alpha particle source $^{241}Am$ and a bare isotopic neutron source $^{252}Cf$, respectively. The effect of the cross-sectional difference between the D(d,p)T and $D(d,n)^3He$ reactions was evaluated for the case of a thick target. The neutron generation rate was theoretically corrected for the anisotropic emission of protons and neutrons in the D-D reactions. The attenuations of neutron on the path to the He-3 detector by the target assembly and vacuum flange of the neutron generator were considered by the Monte Carlo method using the MCNP 4C2 code. As a result, the neutron generation rate based on the Si detector measurement was determined with a relative uncertainty of ${\pm}5%$, and the two rates measured by both detectors corroborated within 20%.

초음파 센서를 이용한 건널목 지장물 검지장치에 관한 고찰 (A consideration on obstacle detector at level crossing using by ultrasonic sensor)

  • 조봉관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.286-288
    • /
    • 2003
  • Accidents at level crossing where railways and roads cross cause many casualties because of collision of cars etc and it also has a risk of the 2nd accident of trains. it is the most vulnerable point in the railway safety. Fundamental solution for accidents at level crossing is making the crossings cubic. but it can't be easily progressed because of environmental and financial difficulties. every kind of anti-accident measures are being strived for. one of the strived results is level crossing obstacle detector which automatically detects obstacles like defected cars etc in the middle of level crossing and transmits the information of obstacles to the approaching train. However present level crossing obstacle auto detector needs high expenses to be installed and has difficulties that lenses of beam transmitter, beam receiver should be cleaned in snowing winter. this document reviews level crossing obstacle auto detector using ultrasonic sensor to measure these difficulties.

  • PDF

용량센서를 적용한 오일증기검출기 거동 해석 (Analysis of Oil-Mist-Detector applied Capacitance Sensor)

  • 이길승;김태옥;김화영;안중환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.279-280
    • /
    • 2006
  • This paper analysised Oil-Mist-Detector applied Capacitance Sensor which protects Diesel engine & human from explosion by detecting density of oil mist distribution. Assuming that distance between oil mists is same, Capacitance sensor plates & all oil mists could be analogized to capacitors. From equivalent circuit of Oil-Mist-Detector, variation of Capacitance which is related to Oil Mist's diameter & density of oil mist distribution is obtainable.

  • PDF