• Title/Summary/Keyword: T형

Search Result 242, Processing Time 0.023 seconds

An Experimental Study on Flexural Strength of Modular Composite profiled Beams (휨 보강된 모듈단면 합성 프로파일보의 휨 내력에 관한 실험적 연구)

  • Ahn, Hyung Joon;Ryu, Soo Hyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.3
    • /
    • pp.323-333
    • /
    • 2007
  • This paper presents a study that attempted to improve the site applicability of profile sheets and check the effects of bending reinforcement in composite profiled beams, and consequently, to suggest an improved modular-type CB2 and two types of bending reinforcement methods. As a result of the reinforcing and reforming modular profiled beam experiment conducted, CBIIshowed an adequate deformation capacity as well as a sufficient plastic plateau at the maximum load and thereafter. For all the specimens, an insignificant modular slip occurred while linear relations were kept constant, at up to approximately 50% of the maximum load and at constant linear relations. The experimental values were very low. Probably, due to the small-scale experiment, the area of the concrete for the concrete filling and covering might have been insufficient, which might have led to the failure to improve the strength. Comparing the results with the standard design stress, all the specimens-except for T16 and B16-indicated more than 0.9. Based on the standard design stress, the reinforced modular profiled beam was consideredto have positive applicability.

A Study on the Practical Load with T-shape Joint Structure by the FEA (유한요소해석에 의한 T형 결합구조물에서의 실하중 산출에 관한 연구)

  • 송준혁;김경재;박형일;강희용;김동우;양성모
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.2
    • /
    • pp.107-115
    • /
    • 2001
  • It is required more precise analysis for practical load because of complexities and varieties of vehicle structure. To establish the numerical model, many researchers have been developed designing tools for linking F.E. Analysis results and experimental results. There studies have generally focused on each experimental method or analytical method separately. There are few studies based on both methods. This paper conceives new procedure for the determination of the load direction and magnitude applied on mechanical structures. New procedure is the combination of the analytical and empirical method with analyzed strain by F.E. Analysis under unit load and with measured principal stress by strain gages under driving load, respectively. In this paper, we theorize the procedure of practical load determination and make the validity and the practicality of the procedure with the application to T-shape jointed structure. F.E. Analysis is conducted to get the principal stress on arbitrary points in the F.E. model of T-shape joint under unit load. Then experiment is carried out to get the principal stress on the same points of F.E. model. To demonstrate the actual driving condition, the load conditions are bending and torsion. From these two data sets, the magnitude, the direction and the position of load can be obtained. Theory and practice do not always coincide; since there are some errors such as ill-poseness, measuring error and modeling error in experimental data, we examine the proper method of error minimization.

  • PDF

Shear Capacity of the RC T Beams Strengthened for Shear with NSM FRP Strips (FRP 판으로 표면매립 전단보강된 철근콘크리트 T형 보의 전단성능)

  • Seo, Soo-Yeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.256-262
    • /
    • 2022
  • The purpose of this study is to define the shear reinforcing effect of Near-Surface-Mounted (NSM) FRP strips in reinforced concrete (RC) member through a test. Three T shaped RC beams were made and two of them were strengthened with NSM FRP strips for increase shear strength. And those were tested to find the shear strengthening effect. In the test, two case of shear strengthening methods were considered such as 1) with NSM FRP strips having full embedded length and 2) with NSM FRP strips having some what short embedded length and additional externally bonded FRP sheet. As a result, the shear strengthening effect could be obtained when the NSM FRP strips are embedded to have full length up to the bottom of slab. However the shear strength was not increased in the case of having somewhat short embedded length of NSM FRP strips even additional EB sheet was enhanced.

Histologic Effects of a Contact Diode Laser on Intraoral Soft Tissue (접촉식 다이오드레이저조사가 구강연조직에 미치는 조직학적 영향)

  • White, Joel M.;Shin, Keum-Back;Thompson, Rick;Myers, Terry D.
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.2
    • /
    • pp.101-108
    • /
    • 1998
  • 본 연구는 두 가지 관점, 즉 다이오드레이저를 구강연조직에 접촉식으로 조사하여 조직을 절제할 경우 첫째 심부조직에서의 온도 상승 정도에 대한 분석 평가, 둘째 절제에 따른 조직의 열적 응고에 대한 조직학적 분석 평가를 위해 시도되었다. 연구를 위해 도축된 소의 혀 배면으로부터 5.0mm깊이에 T형 열전대(type T thermocouple)를 설치하고 조사조건에 따른 레이저절제 도주의 온도변화를 측정하고, 또한 해당조사부위의 조직을 대상으로 통법에 의한 H-E염색 후 조직학적 측면에서 열적 응고상을 검색하여 Nd:YAG레이저의 경우에서와 비교하였다. 즉 파장815nm의 다이오드레이저를 0-10W의 출력, 50Hz와 연속파의 주파수조건에서 접촉식으로 조사하였으며, 또한 파장1064nm의 Nd:YAG레이저를 0-10W의 출력, 50Hz와 100Hz의 주파수 조건에서 접촉식으로 조사하였다. 레이저의 접촉조사시 레이저광섬유 첨단부에서 10(10gm의 일정한 압력과 25mm/sec의 이동속도로 조직을 절제하였다. 레이저가 접촉조사된 조직부위를 통법에 의해 조직학적으로 H-E염색을 시행하였으며, 계측현미경을 이용하여 10배율 아래에서 조직절제의 폭과 깊이, 측방 및 하방 쪽으로 열적 응고의 폭을 계측하였다. 계측치에 대한 통계학적 처리결과 조직절제의 폭과 측방쪽으로 열적응고의 폭은 다이오드레이저에와 Nd:YAG레이저에서 같은 정도를 나타냈다. 조직절제의 깊이는 Nd:YAG레이저에서에 비해 다이오드레이저에서 더 깊었다. 하방쪽으로의 열적응고의 폭은 Nd:YAG레이저를 10Hz의 조건에서 조사한 경우에서 가장 넓었으며, 다이오드레이저를 50Hz와 연속파의 조건에서 조사한 경우에서 가장 좁았다. 레이저절제 도중 심부조직에서의 온도변화는 다이오드 레이저에서와 Nd:YAG레이저에서 모두 출력이 증가함에 따라 상승되었으며, 다이오드레이저에서 보다 Nd:YAG레이저에서 더 높이 상승되었다. 결론적으로 본 연구에서 시도된 조사조건 범위 이내에서는 구강연조직 절제시 다이오드레이저가 펄스형 광섬유 전달식 Nd:YAG레이저 보다 심부조직에서의 낮은 온도상승과 하방쪽으로의 좁은 열적 응고의 폭을 보이면서 우수한 조직절제효과를 나타냈다.

  • PDF

Flexural Strength of Reinforced Concrete T Beams Strengthened with Soffit and Web Fiber Sheets. (섬유시트로 밑면과 옆면이 보강된 T형 철근콘크리트보의 휨 강도)

  • 박대효;이규철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.469-474
    • /
    • 2002
  • Recently fiber sheets are used for strengthening the damaged concrete structures due to its many advantages such as its durability, non-corrosive nature, low weight, ease of application, cost saving, control of crack propagation, strength to thickness ratio, high tensile strength, serviceability and aesthetic. However, the lack of analytical procedures for predicting the nominal moment capacity by the fiber sheet reinforcement leads to difficulties in the effective process of decisions of the factors in the strengthening procedure. In this work, flexural strengthening effects by fiber sheets bonded on soffit and web of the member are theoretically studied for the reinforced concrete T beam. The analytical solutions are compared with experimental results of several references to verify the proposed approach.

  • PDF

Finite Element Analysis of RC Structures considering Bond Characteristics (부착특성을 고려한 RC구조물의 유한요소 해석)

  • 한상호
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.5
    • /
    • pp.157-164
    • /
    • 1997
  • 일반적으로 콘크리트와 철근간의 경계면을 나타내는 유한요소법에는 균열의 부근에서 발생하는 부착열화 현상을 고려하지 않고 있다. 이것은 균열 부근에서 과도한 부착을 초래하고 , 국소 변형과 균열의 진전에도 영향을 준다. 본 연구에서는 철근콘크리트 구조물의 균열부근에서 일어나는 부착거동의 변화를 고려한 비선형 부착응력-미끄럼 모델을 제안하였다. 철근과 콘크리트간의 경계면에는 링크요소를 이용하였고, 링크의 특성은 철근을 가로지르는 균열의 상태에 따라 변하도록 조정하였다. 균열의 형성상태를 정량화하고, 부착거동을 두 포락선 1) 균열로부터 충분히 떨어진 위치에서의 부착상태를 모델링한 외연포락선, 2)횡균열면에 있어서의 부착상태를 모델링한 내연포락선의 사이에 변이시키기 위하여 비국소적 손상도 개념을 도입하였다. 이 방법의 유효성을 알아보기 위하여 편재하중을 받는 T형 교각의 실험 및 해석결과를 제시하였다. 제안된 모델의 결과를 실험결과와 비교하여 본 모델의 유용성을 검증하였다.

Design and Performance Analysis of a Variable Configuration Tracked Vehicle (가변 형상 무한 궤도 차량의 성능 해석 및 설계)

  • 김한호;곽윤근
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.1
    • /
    • pp.20-27
    • /
    • 2001
  • A variable configuration tracked vehicle(VCTV) is developed to reduce turning energy and improve climbing ability for stairs. This mechanism has four track T-type frames. By changing the driving direction, each track T-type frame rotates to minimize the contact area with ground. It also has better performance than other VCTV in energy consumption of turning. Futhermore this mechanism is more stable than other VCTV on the rough terrain. When climbing stairs, each track T-type frame rotates to obtain a front attack angle and keep stability on steep stairs. The design parameters of components of track T-type frames are optimized to enhance the performance of climbing stairs. Performance indices include a stable angle, a climbing ability, a height of the vertical obstacle. In case that the overall length of the mechanism is 0.2m, it is required that the radius of the wheels should be 5mm and the length track contacted with he ground should be 0.09m to climb higher and steeper stairs.

  • PDF

Equivalent Circuit Composition of a Linear Induction Motor (선형유도전동기의 등가회로 구성 - LIM의 T형 등가회로 산정을 위한 구속시험 -)

  • Jang, S.M.;Lee, H.G.;Park, Y.T.;Kim, B.S.;Jeong, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.47-49
    • /
    • 1996
  • The equivalent circuit of LIM is generally composed as the same that of rotary induction motor. However it is very difficult to move the LIM at synchronous velocity for open-secondary circuit test. The resistance representing the core losses in the primary core can not be ignored because the air-gap of LIM is larger than that of rotary induction motor. In this paper, the T-type equivalent circuit of a LIM with the core loss resistance is chosen using static zero slip test and theoritical analysis.

  • PDF

Design and Test of ASME Strainer for Coolant System of Research Reactor (연구용 원자로 냉각계통의 ASME 스트레이너 설계 및 성능시험)

  • Park, Yong-Chul;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.3 s.4
    • /
    • pp.24-29
    • /
    • 1999
  • The ASME strainers have been newly installed at the suction side of each reactor coolant pump to get rid of the foreign materials which may damage the pump impeller or interfere with the coolant path of fuel flow tube or primary plate type heat exchanger. The strainer was designed in accordance with ASME SEC. III, DIV. 1, Class 3 and the structural integrity was verified by seismic analysis. The screen was designed in accordance with the effective void area from the result of flow analysis for T-type strainer. After installation of the strainer, it was confirmed through the field test that the flow characteristics of primary cooling system were not adversely affected. The pressure loss coefficient was calculated by Darcy equation using the pressure difference through each strainer and the flow rate measured during the strainer performance test. And these are useful data to predict flow variations by the pressure difference.

  • PDF

A study on the reidual stress and strain deu to welding of L and T shapes (L형 및 T형 잠류응력과 변형율에 관한 연구)

  • ;;Kim, Won Young
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.5 no.3
    • /
    • pp.199-206
    • /
    • 1981
  • This paper presents a method of calculation of the stresses, the strains and the deflections due to welding in L shape and in T shape. Using step by step method of plasticity and establishing the equilibrium conditions in section, we calculated thermal stresses and strains during welding and in the final step of calculation we got the residual stresses, strains and the deflections due to welding. Also we measured the stresses and the strains with hole-drilling method and compared the results with the method of calculation presented in this paper. Because of its symmetry of section, the deflection due to welding in T shape is generally much less than that in L shape. The residual stresses are tensile in welded joints and HAZ, and compressive in base metal as butt welding of plates, but the compressive stresses in base metal decrease repidly as the points are away from welded joint except horizontal plates of T shape. The theoretical method of calculaiton presented in this paper coincides faily well with the experiment.