• 제목/요약/키워드: T/T probe

검색결과 427건 처리시간 0.024초

Identification of Isoleucine-Accepting tRNA in Maize Mitochondria

  • Park, Young-In;Lee, Byung-Chul;Chang, Hyo-Ihl;Moon, A-Ree
    • BMB Reports
    • /
    • 제28권6호
    • /
    • pp.494-498
    • /
    • 1995
  • Maize mitochondrial tRNAs for isoleucine have been isolated using a putative $tRNA^{Ile}$ gene probe which has been previously isolated and characterized. It contains the 5'-CAT anticodon which would normally recognize the AUG methionine codon. The nucleotide sequence of one of these tRNAs has been partially determined, and contains a modified nucleotide at the first position of the anticodon. This type of posttranscriptional modification event could change the specificity of amino acid acceptance of a tRNA, unlike that deduced from the corresponding gene. An aminoacylation experiment also demonstrated that these purified tRNAs have isoleucine acceptance activity but no methionine-accepting activity.

  • PDF

A FRET Assay for Celiac Disease

  • Lee, Sae A;Cho, Chul Min;Jang, Il Ho;Kang, Jung Sook
    • 대한의생명과학회지
    • /
    • 제22권4호
    • /
    • pp.160-166
    • /
    • 2016
  • To provide a basis for a homogeneous fluorescence resonance energy transfer (FRET) immunoassay for celiac disease, we carried out a FRET experiment using guinea pig tissue transglutaminase (tTG) and antibodies to tTG (anti-tTG) purified from rat serum. Fluorescein was utilized as the probe, and a nonfluorescent dye, QSY 7 served as the quencher. We labeled anti-tTG and tTG with fluorescein isothiocyanate and QSY 7 succinimidyl ester, respectively. Fluorescein-labeled anti-tTG was the donor, and QSY 7-labeled tTG was the acceptor of the FRET experiment. When we titrated fluorescein-labeled anti-tTG with QSY 7-labeled tTG, we observed a large decrease in the steady-state fluorescence intensity, which was due to strong FRET from fluorescein-labeled anti-tTG to QSY 7-labeled tTG. Using time-resolved fluorescence spectroscopy, we could also observe a decrease in the fluorescence lifetime, which confirms the steady-state data. We expect that these results might be useful in the development of a novel fluorescence immunoassay for an easy screening and follow-up of celiac patients.

T/R코일프로브를 이용한 원전 SG세관 검사의 와전류탐상 신호해석 (Signal Analysis of Eddy Current Test Using T/R Coil Probe for Inspection of Steam Generator Tube in NPP)

  • 임건규;이향범
    • 조명전기설비학회논문지
    • /
    • 제22권4호
    • /
    • pp.159-165
    • /
    • 2008
  • 본 논문에서는 전자기 유한요소 해석을 통하여 배열와전류프로브의 T/R 코일의 와전류탐상 특성을 해석하였다. 신호해석을 위해 사용된 결함은 Notch 결함이며, 결함의 깊이는 관두께를 기준으로 40[%]로 하였으며, 결함의 위치는 관의 내부 및 외부에 있는 것으로 하였다. Transmit 코일을 중심으로 Receive 코일의 위치를 원주방향으로 $0[^{\circ}]$, $30[^{\circ}]$, $60[^{\circ}]$, $90[^{\circ}]$에 위치시키면서 신호해석을 수행하였다. 프로브의 전자기적 특성을 해석하기 위하여 맥스웰 방정식을 이용하여 지배방정식을 유도하였고, 이를 3차원 유한요소법을 이용하여 수치 해석을 수행하였다. 두 종류 결함의 수치해석 비교 결과 내부결함의 신호가 외부결함보다 크게 발생하였고, Transmit 코일에 대한 Receive 코일의 각도 및 위치 변화시 결함신호의 차이를 확인할 수 있었다. ASME 표준 시험편을 이용한 배열와전류 프로브의 와전류탐상 실험신호와 비교결과 유사한 신호를 확인할 수 있었다. 본 논문의 결과는 배열와전류 프로브의 와전류 탐상 신호 평가시 도움이 될 것이다.

재발성 호흡기 증상을 동반한 병적 위식도 역류 질환에서 이중 채널 식도내 pH 검사의 의의 (Clinical Significance of Dual-probe Esophageal pH Monitoring in Pathological Gastroesophageal Reflux Disease with Recurrent Respiratory Symptoms)

  • 최윤창;문경래
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제6권1호
    • /
    • pp.17-23
    • /
    • 2003
  • 목 적: 24시간 이 중 채널 식도 pH 검사를 하여 위식도 역류와 호흡기 증상과의 상호 관계를 알아보고 호흡기 증상이 있는 역류 환자에서 원위부와 근위부 식도 pH 측정치를 비교하고자 연구하였다. 방 법: 1998년 8월부터 2002년 8월까지 조선대학교병원 소아과에 위식도 역류의 증상이 있거나 3주일 이상의 만성 기침 등 잦은 호흡기 증상이 있어 식도 pH 검사를 실시한 34명 중 원위부 식도에서 병적인 역류를 보인 17명을 대상으로 하였다. 병적 역류의 기준은 95백분위수 이상의 역류지표 (reflux index)를 병적 역류로 정의하였다. 결 과: 1) 대상 34명에서 호흡기 증상이 있는 16명 중 12명(75%), 호흡기 증상이 없는 18명 중 5명(28%)에서 원위부 식도에서 병적 역류를 보였다. 2) I군에서 근위부와 원위부의 역류 지수, 총 역류횟수, 5분 이상 지속된 역류의 횟수, 최장 역류 시간 등 모든 항목들이 유의한 차이를 보였다(P<0.05). 3) II군에서 근위부와 원위부의 최장 역류 시간을 제외한 모든 항목들이 유의한 차이가 없었다(P>0.1). 4) 근위부 식도에서 I군과 II군의 모든 항목들이 유의한 차이가 없었다(P>0.5). 결 론: 원위부 위식도 역류를 보이는 환자에서 호흡기 증상의 유무에 따라 근위부 식도 pH 검사 결과의 모든 항목에서 차이를 보이지 않아 재발성 호흡기 증상을 보이는 환자에서 이중채널 식도 pH검사의 유용성에 대해 재고가 필요할 것으로 판단된다.

  • PDF

고밀도 프로빙 테스트를 위한 수직형 프로브카드의 제작 및 특성분석 (Development and Characterization of Vertical Type Probe Card for High Density Probing Test)

  • 민철홍;김태선
    • 한국전기전자재료학회논문지
    • /
    • 제19권9호
    • /
    • pp.825-831
    • /
    • 2006
  • As an increase of chip complexity and level of chip integration, chip input/output (I/O) pad pitches are also drastically reduced. With arrival of high complexity SoC (System on Chip) and SiP (System in Package) products, conventional horizontal type probe card showed its limitation on probing density for wafer level test. To enhance probing density, we proposed new vertical type probe card that has the $70{\mu}m$ probe needle with tungsten wire in $80{\mu}m$ micro-drilled hole in ceramic board. To minimize alignment error, micro-drilling conditions are optimized and epoxy-hardening conditions are also optimized to minimize planarity changes. To apply wafer level test for target devices (T5365 256M SDRAM), designed probe card was characterized by probe needle tension for test, contact resistance measurement, leakage current measurement and the planarity test. Compare to conventional probe card with minimum pitch of $50{\sim}125{\mu}m\;and\;2\;{\Omega}$ of average contact resistance, designed probe card showed only $22{\mu}$ of minimum pitch and $1.5{\Omega}$ of average contact resistance. And also, with the nature of vertical probing style, it showed comparably small contact scratch and it can be applied to bumping type chip test.

Effect of Korean Mistletoe Lectin on Gene Expression Profile in Human T Lymphocytes: A Microarray Study

  • Lyu, Su-Yun;Park, Won-Bong
    • Biomolecules & Therapeutics
    • /
    • 제18권4호
    • /
    • pp.411-419
    • /
    • 2010
  • Korean mistletoe has a variety of biological effects, such as immunoadjuvant activities. This study investigates the effects of Korean mistletoe lectin (Viscum album L. var. coloratum agglutinin, VCA) on human T lymphocytes to determine whether VCA acts as an immunomodulator. Purified human T-lymphocytes were cultured with VCA and RNA from each point was analyzed using Affymetrix human genome chips containing 22,500 probe sets which represents more than 18,000 transcripts derived from 14,500 human genes. As a result, there was a striking upregulation of genes coding for chemokines. Seventeen genes out of 50 coding for proteins with chemokine activity were upregulated including CXCL9 and IL-8 which are related to the treatment of cancer. In addition, 28 cytokine genes were upregulated including IL-1, IL-6, IL-8, IFN-$\gamma$, and TNF-$\alpha$. Taken together, the data suggest that Korean mistletoe lectin, in parallel with European mistletoe, has an ability to modulate human T cell function.

혈류 시뮬레이터와 LD의 자기혼합효과를 이용한 혈류계 프로브의 구현 (Implementation of a blood flow simulator and a blood flowmeter probe using self-mixing effect of the laser diode)

  • 김종원;고한우
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.76-77
    • /
    • 1998
  • In this paper, the authors have implemented a blood flow simulator and a blood flowmeter probe using self-mixing effect of the laser diode. The purpose of the blood simulator is to simulate microvascular blood flow in tissue. It consists of melinex film (thickness = $125{\mu}m$) which has similar optical characteristics to epidermis and porous polyethylene filter (Vyon, porosity 35%, mean pore size $50{\mu}m$, thickness=1 mm) which has similar optical characteristics to dermis. The blood flowmeter probe consists of laser diode(5 mW, 780 nm wavelength), CD lens(focal lenght 12 mm), current-to-voltage converter, highpass filter, and preamplifier. It doesn't need optical fiber, therefore, implementation of the probe is simpler than conventional probe using optical fiber.

  • PDF

신경신호기록용 탐침형 반도체 미세전극 어레이의 제작 (Fabrication of Depth-probe type Silicon Microelectrode array for Neural signal Recording)

  • 윤태환;황은정;신동용;김성준
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.147-148
    • /
    • 1998
  • In this paper, we developed the process for depth-probe type silicon microelectrode arrays. The process consists of four mask steps only. The steps are for defining sites, windows, and for shaping probe using plasma etch from above, and for shaping using wet etch from below, respectively. The probe thickness is controlled by dry etching, not by impurity diffusion. We used gold electrodes with a triple dielectric system consisting of oxide/nitride/oxide. The shank of the probe taper from 200um to tens of urn tip and has 30 um thickness.

  • PDF