• 제목/요약/키워드: Systemic blood pressure

검색결과 133건 처리시간 0.026초

과량수혈이 혈역학에 미치는 영향 (Hemodynamic effects of induced overtransfusion of blood in dogs)

  • 기노석
    • Journal of Chest Surgery
    • /
    • 제17권3호
    • /
    • pp.418-423
    • /
    • 1984
  • Appreciation of the large volume deficits which may occur in surgical or trauma patients due to blood loss has led to vigorous transfusion techniques designed to overt hypovolemic shock and ischemic damage to vital organs which may develop in minutes during the hypovolemic state. In a significant proportion of patients treated with massive rapid blood or fluid transfusion, hypervolemia occurs and life threatening pulmonary edema may develop. Especially, hypervolemia may occur during transfusion for preventing development of the so-called low output syndrome following cardiac surgery. However, the most effective indicator which reveals the adequate level of transfusion is not settled yet. The present study was aimed to compare the effectiveness of the indicators suggested thus far and to determine the most sensitive one. Eight dogs were experimentally studied in terms of left atrial pressure, pulmonary arterial systolic pressure, central venous pressure, mean systemic arterial pressure and heart rate before and after induced hypervolemia with infusion of 600ml heparinized homologous blood. Immediately after induced overtransfusion of the blood, pulmonary arterial systolic pressure increased 75.0%, in omparison with the control before transfusion, left atrial pressure 58.8%, central venous pressure 44.6%, and mean systemic arterial pressure 10.1%, one hour after transfusion, pulmonary arterial systolic pressure 40.0%, left atrial pressure 21.2%, central venous pressure 14.5%, and mean systemic arterial pressure 3.2%, central venous pressure 14.5%, and mean systemic arterial pressure 3.2%, respectively. Heart rate showed no significant change throughout the experiment. These result suggested that the changes of the pulmonary arterial systolic pressure is the most sensitive indicator for detection of hypervolemia during blood transfusion.

  • PDF

폐내압증가시(肺內壓增加時)의 동맥혈압(動脈血壓) 및 심박변동(心搏變動)에 관(關)하여 (Responses of Systemic Arterial Blood Pressure and Heart Rates to Graded Increase of Positive Lung Inflation)

  • 김규수;오상유;최병옥;이중길
    • The Korean Journal of Physiology
    • /
    • 제3권2호
    • /
    • pp.25-31
    • /
    • 1969
  • Effects of graded increase of positive lung inflation upon heart rates and arterial blood pressure were observed in the anesthetized dogs to analyze the mechanical and neural regulatory factor in response to the positive inflation of the lung. The results obtained were summarized as followings: 1) When the low grade of positive lung inflation was employed under the mild to moderate anesthesia, central venous pressure was linearly increased while heart rate was decreased. After bilateral vagotomy, central venous pressure was obviously increased while heart rate was constant. 2) When the high degree of positive lung inflation was employed, changes of central venous pressure and heart rate were not significant. 3) The low grade of intrapulmonary pressure increase caused reflex tachycardia in phase 2 and overshooting in phase 4 in response to the systemic arterial blood pressure change. 4) On the other hand, the high degree of intrapulmonary pressure increase caused paradoxical bradycardia in phase 2 and lack of overshooting in phase 4 in response to the systemic arterial blood pressure change. 5) It may be noted that the experimental model employed in the present study is a useful tool to evaluate and analyze the neural and mechanical regulatory factor in response to the graded increase of the positive lung inflation.

  • PDF

A Comparison of Ultrasonic Doppler and Oscillometric Methods in Systemic Blood Pressure Measurement of Dogs

  • Gang, Ho-min;Song, Joong-Hyun;Cho, Kyu-Woan;Jung, Dong-In
    • 한국임상수의학회지
    • /
    • 제33권6호
    • /
    • pp.321-324
    • /
    • 2016
  • The present study compared two indirect blood pressure methods at thoracic limb, pelvic limb, and coccygeal sites. For measurement of blood pressure, 48 client-owned dogs in a clinical setting were used. When comparing the results obtained by doppler and oscillometric methods, there were significant differences in blood pressure of the thoracic and pelvic limbs. The Doppler machine produced significantly higher blood pressure value than oscillometry measured at thoracic and pelvic limbs. The difference in blood pressure between the two methods was not significant when measured in the tail. Comparison of blood pressure measured at three different sites by doppler, blood pressure measured at pelvic limb was higher than at thoracic limb and tail. In case of oscillometry, there were no significant differences between the three sites. The results of this study indicate that mechanical and positional differences were existed in blood pressure measurements at the canine thoracic limb, pelvic limb and tail.

3부위 최적맥파의 주파(h1) 비율 분석을 통한 전체 체순환 평가방법 (Body Systemic Circulation Assessment Method through Analysing the Radial, Dorsalis Pedis, Temporal Arterial Pulse Wave)

  • 유승연;박은성;최예빈;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제33권3호
    • /
    • pp.121-130
    • /
    • 2016
  • Objectives : Recently, people who have normal brachial blood pressure(BP) are being threatened by high-risk disease such as stroke. The aim of this study is to suggest that new method to assess systemic circulation. It can be performed by analyzing optimal blood pulse wave on 3 sites belonging to subjects that have normal BP. Methods : We respectively extracted main peaks(h1) of optimal blood pulse wave on left/right temporal artery(LR1=h1), radial artery(LR2=h1) and dorsalis pedis artery(LR3=h1). We obtained h1 from 30 subjects who are discreetly chosen and have normal BP. Main peak(h1) can be extracted by using 3D pulse imaging analyser(DMP-1000+, DAEYOMEDI Co., Korea) that has 5-level pressure method. We analyzed the ratio of [LR1/LR2] and [LR3/LR2]. Results : In the case of male group, the results are [LR1/LR2=0.7100.177] and [LR3/LR2=0.9290.317]. In the case of female group, the results are [LR1/LR2=0.6680.121] and [LR3/LR2=0.7050.195]. Especially, it is statistically verified that the result of ratio [LR3/LR2] is much higher in male group than in female group(p<0.05). Conclusions : We suggested the standard ratio of [LR1/LR2] and [LR3/LR2] for normal subjects, respectively. It can be adopted as a new method to evaluate the systemic circulation.

한국산 잡견에서 백혈구 제거 충진액이 체외순환 중 위점막 이산화탄소 농도와 IL-8 수준에 미치는 영향 (The Effects of Leukocyte Depleted Priming Solution on the Gastric Mucosal $Co_{2}$ Partial Pressure and Serum IL-8 Level during Cardiopulmonary Bypass in Korean Mongrel Dogs)

  • 박건;이종호;김진호;진웅;권종범;김치경;왕영필
    • Journal of Chest Surgery
    • /
    • 제38권12호
    • /
    • pp.807-814
    • /
    • 2005
  • 배경: 체외순환은 심정지를 필요로 하는 모든 심장 수술에서 정지된 심장의 기능을 대신하여 환자의 말초 장기의 혈액순환을 유지하기 위한 필수적인 과정이다. 그러나 체외순환은 필연적으로 인공도관을 관류하는 특성상 신체의 혈관계를 흐르는 혈류와 달리 혈액손상에 따른 전신성 염증반응을 피할 수 없으며, 이러한 전신성 염증반응과 함께 말초혈관의 미세혈관 순환장애가 체외순환동안에 원발장기의 손상을 초래하는 것으로 생각된다. 저자들은 전신성 염증반응을 일으키는 주된 혈액성분인 백혈구를 제거한 충진액을 사용하여 전신성 염증반응을 줄일 수 있는가를 확인하고, 체외순환도중 위점막의 산도를 측정함으로써 위점막의 미세혈류에 대한 백혈구 제거 충진액의 효과를 확인하기 위하여 실험을 진행하였다. 대상 및 방법: 실험군은 15마리의 한국산 잡견을 충진액의 성분에 따라 비혈액성 충진액군, 백혈구 제거 혈액성 충진액군, 백혈구 비제거 혈액성 충진액군으로 각각 5마리씩 세 군으로 나누었다. 세 군 모두에서 2시간의 체외순환 및 연속된 4시간의 마취유지를 시행하였으며, 체외순환 전과 체외순환 후 1시간, 2시간, 체외순환 종료 후 2시간 4시간에 위점막 이산화탄소 농도와 산도, 동맥혈 이산화탄소 분압 과 호기말 이산화탄소 분압을 측정하고, 염증반응의 지표검사를 위하여 동맥혈을 채혈하였다. 전신성 염증반응의 정도는 채취한 동맥혈에서 ELISA (enzyme linked immunosorbent assay)법을 이용하여 IL-8의 수준을 검사하였다. 결과: 1, 위점막의 이산화탄소 농도는 백혈구 제거 혈액성 충진액군이 백혈구 비제거 혈액성 충진액군과 비혈액성 충진액군에 비하여 유의하게 낮았다(p=0.02, 0.01). 2. 위점막의 산도는 백혈구 제거 혈액성 충진액군과 백혈구 비제거 혈액성 충진액군간에 유의한 차이를 보였다(p=0.01). 3. 전신성 염증반응의 정도를 확인하기 위하여 측정한 IL-8의 수준은 백혈구 제거 혈액성 충진액군과 비혈액성 충진액군이 백혈구 비제거 혈액성 충진액군에 비하여 유의하게 낮았다(p=0.01, 0.01). 결론: 백혈구를 제거한 혈액성 충진액을 사용하는 것이 체외순환중 위점막의 미세순환 장애를 방지하고 전신성 염증반응을 감소시킬 수 있음을 확인하였다.

본태성 고혈압에 대한 기국지황환(杞菊地黄丸)의 효과에 관한 체계적 고찰 및 메타 분석 (Qu-Ji-Du-Huang-Wan for Essential Hypertension : Systemic Review and Meta-analysis)

  • 한인식;신지혜;조윤영;박해모;양창섭;정민정;장인수;선승호
    • 동의생리병리학회지
    • /
    • 제31권2호
    • /
    • pp.118-125
    • /
    • 2017
  • The purpose of this study is to investigate the blood pressure reducing effect of Qi-Ju-Di-Huang-Wan (QJDHW) in adults with essential hypertension by using methods of systemic review and meta-analysis. Major search engines, such as PubMed, EMBASE, Cochrane library, Web of Science, CNKI, CiNii, J-STAGE, KISS, NDSL, RISS, OASIS, DBpia and so on, were used. The search period we used is from the start date of the search engine to October 30, 2016 and no language limits were placed. Randomized controlled trials using QJDHW in adults with essential hypertension were searched and extracted by two independent researchers. Meta-analysis was performed on outcome variables of the total effective rate (TER), systolic blood pressure (SBP) and diastolic blood pressure (DBP). Risk of bias (RoB) of Cochrane was used to assess methodological quality. Thirteen studies were finally selected. We observed that the combined treatment of QJDHW and antihypertensive drug had 3.6 times the odds ratio of TER for blood pressure lowering than a single use of an antihypertensive drug. Additionally, mean differences of SBP and DBP were -8.88 mmHg (95% Confidential Interval (CI) -12.77 mmHg, -5.00 mmHg, P<0.00001), -7.09 mmHg (95% CI -9.93, -4.25, P <0.00001), respectively. Single use of QJDHW did not reduce blood pressure more than an antihypertensive drug. All items of RoB were unclear and the methodological quality was low. Our analysis suggests that the combination of QJDHW and antihypertensive drugs may be more effective in reducing blood pressure than a single antihypertensive drug. But due to low methodological quality, careful interpretation will be needed and systematic long-term clinical trials will be required.

대동맥 반사파를 재현한 4 element 대동맥 혈압 모델을 이용한 혈압 기반 진단 기술의 평가 (Estimation of Blood Pressure Diagnostic Methods by using the Four Elements Blood Pressure Model Simulating Aortic Wave Reflection)

  • 최성욱
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권5호
    • /
    • pp.183-190
    • /
    • 2015
  • Invasive blood pressure (IBP) is measured for the patient's real time arterial pressure (ABP) to monitor the critical abrupt disorders of the cardiovascular system. It can be used for the estimation of cardiac output and the opening and closing time detection of the aortic valve. Although the unexplained inflections on ABP make it difficult to find the mathematical relations with other cardiovascular parameters, the estimations based on ABP for other data have been accepted as useful methods as they had been verified with the statistical results among vast patient data. Previous windkessel models were composed with systemic resistance and vascular compliance and they were successful at explaining the average systolic and diastolic values of ABP simply. Although it is well-known that the blood pressure reflection from peripheral arteries causes complex inflection on ABP, previous models do not contain any elements of the reflections because of the complexity of peripheral arteries' shapes. In this study, to simulate a reflection wave of blood pressure, a new mathematical model was designed with four elements that were the impedance of aorta, the compliance of aortic arch, the peripheral resistance, and the compliance of peripheral arteries. The parameters of the new model were adjusted to have three types of arterial blood pressure waveform that were measured from a patient. It was used to find the relations between the inflections and other cardiovascular parameters such as the opening-closing time of aortic valve and the cardiac output. It showed that the blood pressure reflection can bring wide range errors to the closing time of aortic valve and cardiac output with the conventional estimation based on ABP and that the changes of one-stroke volumes can be easily detected with previous estimation while the changes of heart rate can bring some error caused by unexpected reflections.

Central noradrenergic mechanism in the regulation of blood pressure in SHR

  • 김연태
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 1995년도 제3회 추계심포지움
    • /
    • pp.115-124
    • /
    • 1995
  • The purpose of the present study was to address whether the in vivo noradrenergic neural activities in the locus coeruleus are involved in the regulation of blood pressure. Two groups of the animals were prepared, 1) SHR and 2) age-matched normotensive control, WKY. At the age of 6 and 16 weeks, blood pressure and the releases of NE from the locus coeruleus in SHR and KWY were measured by in vivo microdialysis at three different conditions: 1) normal, 2) elevated state of blood pressure by systemic injected phenylephrine and 3) increased state of neural activity by perfused phenylephrine into the locus coeruleus. The basal release of NE of SHR were significantly higher than that of WKY, Phenylephrine treatment caused elevation of blood pressure in both SHR and WKY in dose-dependent manner. Following phenylephrine injection, the releases of NE from the locus coeruleus of SHR were significantly decreased, whereas the significant change of NE in WKY was observed in the highest dose of phenylephrine. Phenylephrine perfusion into the locus coeruleus through microdialysis probe caused pressor responses and the pressor response in SHR was greater compared with that in WKY. The results from the present study suggests that the noradrenergic nervous system in the locus coeruleus may contribute as one of the development and maintenance factors for hypertension in SHR.

  • PDF

우황청심원이 정상인의 뇌혈류 및 혈압에 미치는 영향 (Effects of Uwhangchungsimwon(牛黃淸心元) on Cerebral Blood Flow and Systemic Blood Pressure in Humans)

  • 김영석
    • 대한한방내과학회지
    • /
    • 제20권1호
    • /
    • pp.222-231
    • /
    • 1999
  • Uwhangchungsimwon(UC) has been used in the treatment of a wide variety of conditions including stroke, hypertension, arteriosclerosis, autonomic imbalance, mental instablity, etc in Korean traditional hospitals, In particular it is often initialy chosen for emergency care of acute stroke. The aim of this study was to evaluate the effect of UC on cerebral hemodynamics. Using transcranial Doppler ultrasound, we studied changes of mean flow velocity and pulsatility index(PI) of middle cerebral arteries (MCAs) from 11 health young volunteers who were administrated with 1 pill UC and 11 health controls who were not. We obtained hypercapnia with breath-holding and evaluated cerebrovascular reactivity with breath-holding index(BHI). Systolic blood pressure, diastolic blood pressure, and heart rate were measured using ambulatory blood pressure monitoring(ABPM). In UC administration group, the evaluation was performed during basal condition. and repeated at 20, 40, and 60 min after administration. In controls, the evaluation was performed at corresponding time intervals. Mean flow velocity in middle cerebral artery, systolic blood pressure, diastolic blood pressure, and heart rate did not change during the observation period and were not different between these two groups. However, administration of UC was associated with decreases in PI by $3.6{\sim}12.4%$ in BHI by $17.9{\sim}24.8%$ compared with pre-administration period. Decreases in PI and BHI with UC were significantly different compared with control group (p<0.05). These results indicate that UC decreases PI and BHI in cerebral artery, which is due to a dilation of cerebral resistance vessels.

  • PDF