• Title/Summary/Keyword: SystemC

Search Result 26,375, Processing Time 0.072 seconds

Objective Analysis of the Set-up Error and Tumor Movement in Lung Cancer Patients using Electronic Portal Imaging Device (폐암 환자에서 Electronic Portal Imaging Device를 이용한 자세 오차 및 종양 이동 거리의 객관적 측정)

  • Kim, Woo-Cheol;Chung, Eun-Ji;Lee, Chang-Geol;Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.69-76
    • /
    • 1996
  • Purpose : The aim of this study is to investigate the random and systematic errors and tumor movement using electronic portal imaging device in lung cancer patients for the adequate margin in the treatment planning of 3-dimensional conformal therapy. Material and Methods : The electronic portal imaging device is matrix ion chamber type(Portal Vision, Varian). Ten patients of lung cancer treated with chest irradiation were selected for this study. Patients were treated in the supine position without immobilization device. All treatments were delivered by an 10 MV linear accelerator that had the portal imaging system mounted to its ganrty. AP or PA field Portal images were only analyzed. Radiation therapy field included the tumor, mediastinum and supraclavicular lymph nodes. A total of 103 portal images were analyzed for set-up deviation and 10 multiple images were analyzed for tumor movement because of respiration and cardiac motion. Result : The average values of setup displacements in the x, y direction was 1.41 mm, 1 78 mm, respectively. The standard deviation of systematic component was 4.63 mm, 4.11 mm along the x, y axis, respectively while the random component was 4.17 mm in the x direction and 3.31 mm in the y direction. The average displacement from respiratory movement was 12.2 mm with a standard deviation of 4.03 mm. Conclusion : The overall set-up displacement includes both random and systematic component and respiratory movement. About 10 mm, 25 mm margins along x, y axis which considered the set-up displacement and tumor movement were required for initial 3-dimensional conformal treatment planning in the lung cancer patients and portal images should be made and analyzed during first week of treatment, individually.

  • PDF

Dose Distribution and Characterization for Radiation Fields of Multileaf Collimateor System (방사선 입체조형치료용 다엽콜리메이터의 특성과 조직내 선량분포 측정)

  • Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Purpose : Multileaf collimator(MLC) is very suitable tool for conformal radio-therapy and commissioning measurements for a multileaf collimator installed on a dual energy accelerator with 6 and 10MV photons are required, For modeling the collimator with treament planning software, detailed dosimetric characterization of the multileaf collimator including the penumbra width, leaf transmission between leaf leakage and localization of the leaf ends and sides is an essential requirement. materials and Methods : Measurement of characteristic data of the MLC with 26 pair block leaves installed on CLINAC 2100C linear accelerator was performed. Low sensitive radiographic film(X-omatV) was used for the penumbra measurement and separate experiments using radiographic film and thermoluminescent dosimeters were performed to verify the dose distribution, Measured films were analized with a photodensitometer of WP700i scanner. Results : For 6 & 10 MV x-ray energies, approximately $2.0\%$ of photons incident on the multileaf collimator were transmitted and an additional $0.5\%$ leakage occurs between the leaves. Localizing the physical end of the leaves showed less than 1mm deviation from the $50\%$ decrement line and this difference is attributed to the curved shaped end on the leaves One side of a sin히e leaf corresponded to the $50\%$ decrement line, but the opposite face was aligned with a lower value. This difference is due to the tongue and groove used to decrease between leaf leakage. Alignment of the leaves to form a straight edge resulted larger penumbra at far position from isocenter as compare with divergent alloy blocks. When the MLC edge is stepped by sloping field, the isodose lines follow the leaf pattern and Produce scalloping isodose curves in tissue. The effective penumbra by 45 degree stepped MLC is about 10mm at 10cm depth for 6MV x-ray. The difference of effective penumbra in deep tissue between MLC and divergent alloy blocks is small (5mm). Conclusion : Using the characteristic data of MLC, the MLC has the clinlical acceptability and suitability for 3-D conformal radiotherapy except small field size.

  • PDF

Design of Ultrasonic Nebulizer for Inhalation Toxicology Study of Cadmium with Application of Engineering Methodology and Performance Evaluation with Light-Scattering Photometer (공학적 기법을 응용한 카드뮴의 흡입독성 연구를 위한 초음파 네뷸라이져의 설계 그리고 광산란 광도계를 이용한 성능평가)

  • Jeung Jae Yeal;Milton Donald K.;Kim Tae Hyeung;Lee Jong Young;Chong Myoung Soo;Ko Kwang Jae;Kim Sang Duck;Kang Sung Ho;Song Young Sun;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.3
    • /
    • pp.464-471
    • /
    • 2002
  • Author applied several engineering methodologies to classical ultrasonic nebulizer to cope with it's demerits. After several trials and errors, we got the several meaningful results. To evaluate the modified ultrasonic nebulizer for inhalation toxicology of cadmium, author used light-scattering photometer. This paper is the one part of inhalation exposure systems for inhalation toxicology study of cadmium. According to the testing conditions, source temperature 50℃ and inlet-duct band temperature 150℃, aerosol generation results for sodium chloride and cadmium chloride were as followings: Coefficients of variation(CV) of sodium chloride and cadmium chloride for repeated trials were 3.38 and 4.77 for 10g, 2.47 and 5.02 for 5g, and 4.70 and 2.98 for 2.5g. All the CVs were within 10% of acceptance variability. Count Per Minute(CPM) changes of NaCl and CdCl₂ for 5 repeated trials were similar. CPM ratios of CdCl₂/NaCl were 1.13 for 10g, 0.76 for 5g, and 1.06 for 2.5g. Relative aerosol generation of cadmium chloride to sodium chloride was the highest in 10g. Efficiency increases of 24.50% for 5g NaCl, 14.91 % for 2.5g NaCl, and 16.48% for 2.5g CdCl₂ with respect to theoretical efficiency were observed but 0.04% efficiency decrease was observed in 5g CdC₂. According to the modifications of source temperature(20, 50, 70℃) and inlet-duct band temperature(20, 50, 100, 150, 200℃), aerosol generation results for NaCl and CdCl₂ were as followings: CPM trends for each quantity excepting 10g NaCl in inlet-duct band temperature 200℃ were similar, and the highest CPM was observed in source temperature 70℃ to each inlet-duct band temperature. The highest CPMs to 10, 5, and 2.5g NaCl were observed in source temperature 70℃ and inlet-duct band temperature 20℃. Aerosol generation of cadmium chloride was increased with the higher source temperature, excepting inlet-duct band temperature 200℃. The highest CPMs for 10, 5, and 2.5g CdCl₂ were observed in source temperature 70℃ and inlet-duct band temperature 20℃, and this trend was similar to NaCl aerosol generation The highest CPMs for 10, 5, and 2.5g CdCl₂ were observed in source temperature 70℃ and inlet-duct band temperature 20℃, and this result was similar to NaCl aerosol generation. Observed efficiencies of 5 and 2.5g NaCl were similar to ifs theoretical efficiency but -3.08% efficiency decrease of 5g CdCl₂, 17.47% efficiency increase of 2.5g CdCl₂ were observed. CPM ratio of CdCl₂/NaCl of 10g was different to 5 and 2.5g, and 2.5g ratio was higher than 5g ratio. In conclusion, to get maximum aerosol generation for NaCl and CdCl₂ will be the conditions that set the appropriate inlet-duct band temperature for each materials and increase the source temperature. Sodium chloride can be used to evaluate the performance and predict the concentration for cadmium aerosol in aerosol generator and inhalation exposure system.

The Clinical Study of the Lower Respiratory Tract Infection by Respiratory Syncytial Virus on Children under 2 Year of Age (2세 이하 어린이에서 Respiratory Syncytial Virus에 의한 하기도 감염에 관한 연구)

  • Cho, Jung Ik;Choi, Hyung Chul;Kim, Jong Duck;Cho, Ji Hyun
    • Pediatric Infection and Vaccine
    • /
    • v.7 no.2
    • /
    • pp.193-200
    • /
    • 2000
  • Purpose : This study was designed and performed for evaluations of clinical manifestation and course of the children under 2 year of age with respiratory tract infection and positive respiratory syncytial virus(RSV) antigen. Methods : The selection criteria of the patients were children under 24 month-of-age, Clinical manifestation of respiratory tract infection, and positive RSV antigen that was detected by Vitek ImmunoDiagnostic Assay System(VIDAS) from nasal cavity. The additional laboratory and simple chest X-ray findings were reviewed from the chart of children who were admitted Wonkwang university hospital from October 1999 to March 2000. Results : Total number of patients enrolled on this study was 102. The 48(47%) children were RSV antigen positive by VIDAS method. Abnormal chest X-ray findings were noticed in 38 cases. The male to female sex ratio of 48 RSV antigen positive cases was 1.2 : 1. The mean and range of age was $10.2{\pm}5.9$ and 1.0~24 months. The peak outbreak of cases was noticed on November, 1999. All of the cases shows coughing but rale was audible in 30 cases(60%). Dyspnea, wheezing, and intercostal retraction were noticed 11(23%), 15(31%), and 10(21%) cases respectively. The most common chest X-ray finding was scattered patch infiltration that was noticed in 30 cases(63%). The mean total white blood cell counts in peripheral blood was $12,608{\pm}4,686/mm^3$. The mean blood level of IgA and IgE were $50.8{\pm}20.9$ and $72.1{\pm}98.3mg/dL$ respectively. The C-reactive protein was $16.0{\pm}18.5mg/L$. Total 5 cases need a mechanical respiraton. The duration of admission was under 7 days in 36 cases(75%). Conclusion : The RSV antigen was detected commonly in late fall and winter season. The severity of children under 2 years old with RSV respiratory tract infection take in some degree a gave courses.

  • PDF

Quantification of Caffeic Acid and Rosmarinic Acid and Antioxidant Activities of Hot-water Extracts from Leaves of Perilla frutescens (품종별 들깻잎 열수추출물의 caffeic acid와 rosmarinic acid의 함량 및 항산화력 비교)

  • Lee, Hyun-Sun;Lee, Hyun-Ah;Hong, Chung-Oui;Yang, Sung-Yong;Hong, Sung-Yu;Park, Sang-Yul;Lee, Ho-Jung;Lee, Kwang-Won
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.3
    • /
    • pp.302-306
    • /
    • 2009
  • The principal objective of this investigation was to identify adequate species for the harvest of Perilla frutescens leaves, which provide profound antioxidant activities, and harbor abundant caffeic acid and rosmarinic acid. Namchun, Donggeul-2, Bora, Sae-bora and Neul-bora variants of the plant were assessed herein. In this study, we evaluated the antioxidant effects of these plants, and utilized an HPLC system to verify their caffeic acid and rosmarinic acid contents. Dried Perilla frutescens leaves were boiled at a temperature of $100^{\circ}C$ for three hours, and were lyopholized in a freezedryer. The extracts were then processed in order to confirm their antioxidant activities via 1,1-diphenyl-2-picrylhydrazyl (DPPH) free radical-scavenging activity assay, ferric-reducing antioxidant power (FRAP) assay, total flavonoid content and total polyphenol content assays. According to the observed antioxidant results of the five tested species of Perilla frutescens leaves, Bora and Donggeul-2 were shown to have more potent antioxidant activities than the other tested variants. The scavenge 50% of DPPH radical ($SC_50$ of DPPH) values were 241 ${\mu}g$ DM/mL in Donggeul-2 and 261 ${\mu}g$ DM/mL in Bora. Based on the results of the FRAP assay, the Bora variant showed a value of 796 mM $FeSO_4$ $7H_2O/g$ DM, and Donggeul-2 exhibited a value of 748 mM $FeSO_4$ $7H_2O/g$ DM, of which the total polyphenol contents were measured as 69.4 g GAE/kg DM and 61.8 g GAE/kg DM, respectively. Moreover, the Bora variant had the highest level of caffeic acid, and Donggeul-2 showed the highest rosmarinic acid content among the tested samples (0.87 mg/100 g wet base and 121 mg/100 g wet base, respectively). According to the results of this experiment, we selected two species, Bora and Donggeul-2, which were both verified to contain adequate and favorable antioxidant activities.

Carbon and Nitrogen Stocks of Trees and Soils in a 'Niitaka' Pear Orchard ('신고'배 재배지 내 수체 및 토양의 탄소 및 질소 저장량)

  • Lee, Tae-Kyu;Choi, Jang-Jeon;Kim, Jong-Sung;Lee, Han-Chan;Ro, Hee-Myong
    • Horticultural Science & Technology
    • /
    • v.31 no.6
    • /
    • pp.828-832
    • /
    • 2013
  • To report country-specific carbon and nitrogen stocks data in a pear orchard by Tier 3 approach of 2006 IPCC guidelines for national greenhouse gas inventories, an experimental pear orchard field of the Pear Research Station, National Institute of Horticultural & Herbal Science, Rural Development Administration, Naju, Korea ($35^{\circ}01^{\prime}27.70N$, $126^{\circ}44^{\prime}53.50^{\prime\prime}E$, 6 m altitude), where 15-year-old 'Niitaka' pear (Pyrus pyrifolia Nakai cv. Niitaka) trees were planted at a $5.0m{\times}3.0m$ spacing on a Tatura trellis system, was chosen to assess the total amount of carbon and nitrogen stocks stored in the trees and orchard soil profiles. At the sampling time (August 2012), three trees were uprooted, and separated into six fractions: trunk, main branches, lateral branches (including shoots), leaves, fruits, and roots. Soil samples were collected from 0 to 0.6 m depth at 0.1 m intervals at 0.5 m from the trunk. Dry mass per tree was 4.7 kg for trunk, 13.3 kg for main branches, 13.9 kg for lateral branches, 3.7 kg for leaves, 6.7 kg for fruits, and 14.1 kg for roots. Amounts of C and N per tree were respectively 2.3 and 0.02 kg for trunk, 6.4 and 0.07 kg for main branches, 6.4 and 0.09 kg for lateral branches, 6.5 and 0.07 kg for roots, 1.7 and 0.07 kg for leaves, and 3.2 and 0.03 kg for fruits. Carbon and nitrogen stocks stored between the soil surface and a depth of 60 cm were 138.29 and $13.31Mg{\cdot}ha^{-1}$, respectively, while those contained in pear trees were 17.66 and $0.23Mg{\cdot}ha^{-1}$ based on a tree density of 667 $trees{\cdot}ha^{-1}$. Overall, carbon and nitrogen stocks per hectare stored in a pear orchard were 155.95 and 13.54 Mg, respectively.

Adoption and Efficacy of ISO 15189 in Medical Laboratories for Diagnostic and Research (메디컬시험기관에서 ISO 15189 도입의 필요성과 시행의 효용성)

  • Yang, Man-Gil;Lee, Won Ho;Jun, Jin Hyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.2
    • /
    • pp.158-167
    • /
    • 2016
  • The requirements for medical laboratories ISO 15189 is examined in organization and a quality management system, stressing the importance of evidence, document control, and control of records and clinical material. Medical services are provided from the areas of resource management, and pre-examination, examination and post-examination processes. The main goal of ISO 15189 accreditation is to improve the quality of laboratory services provided for patients and clinical users not only through compliance with consensually developed and harmonized requirements but also by adopting the philosophy of continual improvement using the Plan-Do-Check-Act cycle. Laboratory quality should be evaluated and improved in all steps of the testing process as the state-of-the art indicates that the pre- and post-analytical phases are more vulnerable to errors than the intra-analytical phase. The Korea Laboratory Accreditation Scheme (KOLAS), a national accreditation body, provides medical laboratory accreditations for appropriate approaches to evaluating the competence of a medical laboratory in providing effective services to its customers and clinical users. Adoption of ISO 15189 in 2010s as a government policy has been delayed, and only 5 laboratories have been accredited to date in Korea. The medical laboratories should seek the adoption of ISO 15189 with a positive attitude for quality improvement and strengthening of international competitiveness.

Development of Assay Methods for Enterotoxin of Escherichia coli Employing the Hybridoma Technology (잡종세포종기법을 이용한 대장균의 장독소 측정법 개발)

  • Kim, Moon-Kyo;Cho, Myung-Je;Park, Kyung-Hee;Lee, Woo-Kon;Kim, Yoon-Won;Choi, Myung-Sik;Park, Joong-Soo;Cha, Chang-Yong;Chang, Woo-Hyun;Chung, Hong-Keun
    • The Journal of the Korean Society for Microbiology
    • /
    • v.21 no.1
    • /
    • pp.151-161
    • /
    • 1986
  • In order to develop sensitive and sepcific assay methods for E. coli heat labile enterotoxin(LT) hybridoma cell lines secreting LT specific monoclonal antibody were obtained. LT was purified from cell lysate of E. coli O15H11. The steps included disruption of bacteria by French pressure, DEAE Sephacel ion exchange chromatography, Sephadex G200 gel filtration, and second DEAE Sephacel ion exchange chromatography, successively. Spleen cells from Balb/c mice immunized with the purified LT and $HGPRT^{(-)}$ plasmacytomas, $P3{\times}63Ag8.V653$ were mixed and fused by 50% (w/v) PEG. Hybrid cells were grown in 308 wells out of 360 wells, and 13 wells out of them secreted antibodies reacting to LT. Among these hybridoma cell 1G8-1D1 cell line was selected since it had produced high-titered monoclonal antibody continuously. By using culture supernatant and ascites from 1G8-1D1 cells the monoclonal antibody was characterized, and an assay system for detecting enterotoxigenic E. coli was established by double sandwich enzyme-linked immunosorbent assay (ELISA). The following results were obtained. 1. Antibody titers of culture supernatant and ascites from 1G8-1D1 hybridoma cells were 512, and 102, 400, respectively by GM1-ELISA and its immunoglobulin class was IgM. 2. The maximum absorption ratio of 1G8-1D1 cell culture supernatant to LT was 90% at $300\;{\mu}g/ml$ of LT concentration. LT concentration shown at 50% absorption ratio was $103.45{\mu}g$ and the absorption ratio was decreased with tile reduction of LT concentration. This result suggests that monoclonal antibody from 1G8-1D1 hybridoma cell bound with LT specifically. 3. The reactivities of 1G8-1D1 cell culture supernatant to LT and V. cholerae enterotoxin(CT) were 0.886 and 0.142(O.D. at 492nm) measured by the GM1-ELISA, indicating 1G8-1D1 monoclonal antibody reacted specifically with LT but not with CT. 4. The addition of 0.1ml of ascites to 0.6mg and 0.12mg of LT decreased the vascular permeability factor to 41% and 44% respectively, but it did not completely neutralize LT. 5. By double sandwich ELISA using monoclonal antibody, as little as 75ng of the purified LT per ml could be detected. 6. The results by assay of detecting LT in culture supernatants of 14 wild strains E. coli isolated from diarrhea patients by the double sandwich ELISA were almost the same level as those by reverse passive latex agglutination.

  • PDF

Studies on the Improvement of the Fishing Efficiency of Purse Seine in the Sea Area of Cheju Island -The Changes of Seine Volume and Tension in the Purseline During Pursing- (제주도 주변해역 선망의 어획성능 향상에 관한 연구 -짐줄 체결 중 선망의 용적과 짐줄의 장력 변화 -)

  • 김석종
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.2
    • /
    • pp.93-101
    • /
    • 1999
  • A simple experimental method was used in an attempt to realize the elevation of the fishing ability of purse seine in the sea area of Cheju Island, the changes of seine volume and tension in the purseline during pursing. Experiments carried out on the six types simplified reduced model seines which were made of knotless nettings. The nettings were woven in different leg length 4.3, 5.0, 5.5, 6.0, 6.6 and 7.7mm of polyester 28 tex two threads two-ply twine, and each of the seines were named I, II, III, IV, V and Ⅵ seine. Dimension of seine models were 450cm for corkline and 85cmfor seine depth, each seines rigged up 160g of float for a floatline and 50g (underwater weight) of lead for a leadline. These model purse seines were made of the scale of 1/200 of its full scale, a 120 ton in the near sea of Cheju Island. Designing and testing for the model purse seines were based on the Tauti's law. Experiments were measured in the observation channel of a flume tank at the static conditions set up shooting and pursing equipments. Motion of purse seine during purse line was recorded by the two sets video camera for VTR which were placed in top and front of the model seine. The reading coordinate of seine volume carried out by the video digitization system, disk data for the purseline tension. An analysis were performed on the changes seine volume and tension in the purseline during pursing. The results obtained were as follows: 1. The seine volume during pursing was largest for Ⅵ seine with smallest d/l followed by V, IV, III, II and I seines, and tension in the purseline was small. 2. Seine volume during pursing can be expressed by the following equation; CVt=l-EXP[{2.79 (d/l)+0.35}t-33.37 (d/l) + 0.57] Where CVt is volume ratio, d is twine diameter, l is leg length and t is pursing time (sec). 3. Tension in the purse line during pursing can be expressed by the following equation; T= 1- EXP {0.57t + 13.36 (d/l)+2.97} Where T is tension (kg) in the purseline during pursing.

  • PDF

Hydrogeochemical and Environmental Isotope Study of Groundwaters in the Pungki Area (풍기 지역 지하수의 수리지구화학 및 환경동위원소 특성 연구)

  • 윤성택;채기탁;고용권;김상렬;최병영;이병호;김성용
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.5 no.4
    • /
    • pp.177-191
    • /
    • 1998
  • For various kinds of waters including surface water, shallow groundwater (<70 m deep) and deep groundwater (500∼810 m deep) from the Pungki area, an integrated study based on hydrochemical, multivariate statistical, thermodynamic, environmental isotopic (tritium, oxygen-hydrogen, carbon and sulfur), and mass-balance approaches was attempted to elucidate the hydrogeochemical and hydrologic characteristics of the groundwater system in the gneiss area. Shallow groundwaters are typified as the 'Ca-HCO$_3$'type with higher concentrations of Ca, Mg, SO$_4$and NO$_3$, whereas deep groundwaters are the 'Na-HCO$_3$'type with elevated concentrations of Na, Ba, Li, H$_2$S, F and Cl and are supersaturated with respect to calcite. The waters in the area are largely classified into two groups: 1) surface waters and most of shallow groundwaters, and 2) deep groundwaters and one sample of shallow groundwater. Seasonal compositional variations are recognized for the former. Multivariate statistical analysis indicates that three factors may explain about 86% of the compositional variations observed in deep groundwaters. These are: 1) plagioclase dissolution and calcite precipitation, 2) sulfate reduction, and 3) acid hydrolysis of hydroxyl-bearing minerals(mainly mica). By combining with results of thermodynamic calculation, four appropriate models of water/ rock interaction, each showing the dissolution of plagioclase, kaolinite and micas and the precipitation of calcite, illite, laumontite, chlorite and smectite, are proposed by mass balance modelling in order to explain the water quality of deep groundwaters. Oxygen-hydrogen isotope data indicate that deep groundwaters were originated from a local meteoric water recharged from distant, topograpically high mountainous region and underwent larger degrees of water/rock interaction during the regional deep circulation, whereas the shallow groundwaters were recharged from nearby, topograpically low region. Tritium data show that the recharge time was the pre-thermonuclear age for deep groundwaters (<0.2 TU) but the post-thermonuclear age for shallow groundwaters (5.66∼7.79 TU). The $\delta$$\^$34/S values of dissolved sulfate indicate that high amounts of dissolved H$_2$S (up to 3.9 mg/1), a characteristic of deep groundwaters in this area, might be derived from the reduction of sulfate. The $\delta$$\^$13/C values of dissolved carbonates are controlled by not only the dissolution of carbonate minerals by dissolved soil CO$_2$(for shallow groundwaters) but also the reprecipitation of calcite (for deep groundwaters). An integrated model of the origin, flow and chemical evolution for the groundwaters in this area is proposed in this study.

  • PDF