• Title/Summary/Keyword: System window

Search Result 1,656, Processing Time 0.027 seconds

An Impact Analysis of Window Mechanism and End to End Delay of Tandem Queueing Network with Constant Service Times (상수 서비스 시간을 갖는 개방형 대기행렬의 종대종 지연과 윈도우 구조의 영향 분석)

  • Rhee Young
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.29 no.3
    • /
    • pp.99-109
    • /
    • 2004
  • In this paper, we investigate the impact of window mechanisms on end to end delay in a series of nodes with constant service times. It is shown that arbitrary combinations of window mechanisms, each applying to an arbitrary subset of data, can be embedded on the nodes without affecting the departure instants from the system if the windows are at least as large as the number of nodes spanned. The window mechanisms are shown to have no impact on the average end to end delay of data. As the condition on the windows is a minimal necessary requirement for full parallelism, the results show that the transparent operation from viewpoint of data transmission can be achieved with minimal resources.

A Study on the Improvement of Adhesive Mixing Ratio about Acoustic Window for Enhancing SONAR Performance of Submarine (수중함 소나 수신성능 향상을 위한 음향창 접착제 배합비 개선)

  • Ham, Younghoon;Kim, Joonwoo;Chang, Hoseong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.481-488
    • /
    • 2018
  • This study suggest the improvement of the CFRP adhesive mixing ratio about acoustic window to enhance SONAR performance. The CFRP of submarine is produced by allocation an acoustic window zone by the beam width of SONAR sensors. During the sea trial, SONAR system's bearing and range accuracy data is not in tolerance due to debonding phenomenon on CFRP. The inappropriate mixing ratio of adhesives caused that peeling phenomenon occurred in the acoustic window part, which is the reason for the deterioration of SONAR sensors performance. The report includes explanation of test procedure of SONAR, root cause analysis, CFRP manufacturing procedure, laboratory tests results, and proof of the performance at the sea trial.

The Effect of the Disturbing Wave on the Speech Intelligibility of the Eavesdropping Sound of a Window Glass (교란파가 유리창 진동음의 음성명료도에 미치는 영향)

  • Kim, Seock-Hyun;Kim, Hee-Dong;Heo, Wook
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.9
    • /
    • pp.888-894
    • /
    • 2007
  • The speech sound is detected by the vibration measurement of the window glass. In this study, we investigate the effect of the disturbing waves by background noise and window shaker excitation on the speech intelligibility of the detected sound. Based upon Modulation Transfer Function(MTF), speech intelligibility of the sound is objectively estimated by Speech Transmission Index(STI) As the level of the disturbing wave varies, variation of the speech intelligibility is examined. Experimental result reveals how STI is influenced by the level and frequency characteristics of the disturbing wave. By using a customized window shaker for disturbing sound, we evaluate the efficiency and the frequency characteristics of the anti-eavesdropping system. The purpose of the study is to provide useful information to prevent the eavesdropping through the window glass.

The Influence of Design Factors of Sonar Acoustic Window on Transfer Function of Self Noise due to Turbulent Boundary Layer (소나 음향창의 설계 인자가 난류 유동 유기 자체 소음의 전달 함수에 미치는 영향 해석)

  • Shin, Ku-kyun;Seo, Youngsoo;Kang, Myengwhan;Jeon, Jaejin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.568-574
    • /
    • 2012
  • Turbulent boundary layer noise is already a significant contributor to sonar self noise. For developing acoustic window of sonar system to reduce self noise, a parametric study of design factors of acoustic window is presented. Distance of sensor array from acoustic window, material and damping layer are studied as design factors to influence in the characteristics of the transfer function of self noise. As the result these design factors make change the characteristics of transfer function slightly. Among design factors the location of sensor array is most important parameter in the self noise reduction.

  • PDF

Design and Performance Evaluation of Hybrid Window Walls With Variable Transmittal Materials (투과시스템의 광학특성을 고려한 복합적 외벽채광부의 성능평가에 관한 연구)

  • Do, Jin-Seok;Kim, Gon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.4 no.2
    • /
    • pp.11-18
    • /
    • 2004
  • Growing use of entire glass facades with metal frames are popularly witnessed in modern building practices and design competition as well. In spite of architectural aesthetics and view to outdoors, environmental issues still exist in that kind of buildings. One of the solutions for the problems might be the use of functional glasses such as a heat-resistant glass or various tinted glasses for the glass walls. This paper aims to provide performance data related to the impact of various transmittal materials of window systems on the light distribution. A series of computer simulation deals with the basic geometrical and optical design elements of a commonly used all-glass facades. Additionally an experimental configuration of the vertical window is proposed for better result of daylighting. A window system equipped with an inner-light shelf can improve the uniformity of natural light in a space by reducing the level of illumination near the window and redirecting light deeply into the space.

Design and Evaluation of Dye-Sensitized Solar Cell Submodule for Self-Powered Smart Liquid Crystal Window (자가발전 스마트 액정 윈도우를 위한 염료감응 태양전지 서브 모듈 설계 및 평가)

  • Byeong-Yun Oh
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.5
    • /
    • pp.494-499
    • /
    • 2024
  • The possibility of a dye-sensitized solar cell (DSSC) submodule was evaluated as an independent power source that can drive a smart liquid crystal window (SLW) that selectively blocks sunlight when electricity is applied. In order to save energy and increase the functionality of buildings, SLW operation was supplied directly from DSSC submodule, rather than connecting to the existing power system and external power sources. It was confirmed that the SLW can control light transmittance through self-generation using the DSSC submodule composed of 6 cells at low light of 2,500 lux. These results imply that there is a high possibility of combining smart windows and DSSCs suitable for window-type building-integrated photovoltaic (BIPV) systems. DSSCs, which can self-generate power in low light, are expected to increase their usability in urban BIPV systems through combination with smart window technology.

The Clinical Application of Sound-Protection

  • Tomohiko, Kamio
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1976.06a
    • /
    • pp.87.1-87
    • /
    • 1976
  • Bekesy measured the sound transformation system of the middle ear 49 years ago. According to his reports, a ratio between the size of ear drum and the size of oval window is 17 : 1, and the lever function of the ossicles is physiologically 1.3 : 1. Therefore, the hearing might be aggravated to 27.5㏈ in the case of the vanishment of 3 ossicles. In 1952, Wullstein reported 5 types of tympanop-lasty and the fourth type among them was especially named for the sound-protection. The oval window is only exposed by the sound pressure and the round window is not exposed. According to the application by this idea, the post-operative hearing might be improved until 27.5㏈. Mean while, in 1942, Onchi verified through his experiment that the results of Bekesy's measurement was not completely conformed to Onchi result. Bekesy measured the sound pressure on the stapes plate of the oval window, on the other hand, Onchi measured the sound pressure on the surface of the perilymph of the oval window after removing the stapes plate(Fig. 1).(Figure omitted) The difference of their experiment is recognized that the impedance of the stapes plate exists or not (Fig. 1). Both Audiogrums are compared as Fig. 2. The result of IV type of tympanoplasty is success ful in 54% as the Table 1. (Table Omitted) The reason of unsatisfactory is caused by the thick and unmovable window-membrane and by the closing of air passage to the round window. The closing of the air passage to the round window is occurred by the adhesion between the grafting membrane and the surface of promontorium. In order to preserve this adhesion, I produce to transplantate the mucous membrane of the lip to the bone surface of tympanic cavity after removing the granulation tissue of the tympanic cavity and to form a membranous canal for the sake of air passage (Fig. 3). (Figure Omitted) The post-operative hearing by this method is shown as Fig. 4, 5. In other words, the post-operative sound pressure entered into the cochlea directly, by way of the oval window only, not by way of the round window, as a theorie of the sound protection. (Figure omitted)

  • PDF

Evaluation on the Solar Heat Gain Coefficient of Glazing System installed in internal shading device by experiments according to the NFRC 201 (NFRC 201 실험방법에 의한 내부 차양장치가 적용된 창호의 일사획득계수 평가)

  • Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.47-54
    • /
    • 2010
  • Recently the researchers has been interested in the development of the high performance windows such as solar control window using automatic shading devices, air-flow window, selective coating window. In order to assess the energy performance of total fenestration system, the net energy gains or losses through the glazings and windows should be evaluated. It depends on the thermal transmittance (U-value) and the total solar energy transmittance (SHGC, g-value). This study aims to measure the solar heat gain coefficient according to the NFRC 201 standard test method. In results, we could find the result of different SHGC of the glazing system with a different slat angles. The SHGC in case of $90^{\circ}$ of internal slat angle with regard to the window surface is about 0.56, that in case of $45^{\circ}$ is about 0.49 and that in case of $0^{\circ}$ is about 0.33. Significant dependence on the solar radiation intensity and incident angle was found in comparison of the measured and simulated SHGC.

Study on the Evaluation of Regional Building Energy Efficiency Rating According to the Insulation Performance of Double Skin Window in Apartment Houses Expanded Balcony (발코니 확장형 공동주택의 이중외피 창호 열성능에 따른 지역별 건축물에너지 효율등급 평가)

  • Jang, Cheol-Yong;Ahn, Byung-Lip;Kim, Chi-Hoon;Hong, Won-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.32-37
    • /
    • 2010
  • In order to handle the crisis about energy-environment problem, it is necessary to develop the future-oriented and innovative energy technology in architecture area. So the development of new technology for energy saving and alternative energy use has been spurred in this area. Double skin window system, which is an active covering to respond to the exterior change of the environment, is the skill that can reduce the indoor cooling and heating load and the environmental architecture can be realized. This study works out U-value of windows using the window-simulation program with the development and study of the double skin. In addition, the effect of the double skin insulation on the efficiency rating has been analyzed, applying to the certification system of the building energy efficiency rating which has implemented.

An Analysis of the Current State of Window Constructions in Small-scale Private Architecture in Consideration of the Energy Consumption Efficiency Rating System (소규모 민간건축에 있어서 에너지소비효율등급제를 고려한 창호공사 현황분석)

  • Kang, Suk-Pyo;Jin, Eun-Mi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.1
    • /
    • pp.43-51
    • /
    • 2015
  • At present, in the case of small and medium window manufacturers in South Korea, glazing and window frame manufacturers are divided into separate businesses. However, in the fenestration energy consumption efficiency rating system and the energy-saving design criteria for buildings, the coefficient of overall heat transmission standard for windows is defined by window sets, which integrate glazing and window frames. At most construction sites, windows are constructed by installing separately supplied glass and frames. Research that can integrate the reality and the system is therefore necessary. The present study first investigated and analyzed the on-site situation of the fenestration energy consumption efficiency rating system. According to the results, while overall understanding of the fenestration energy consumption efficiency rating system was high, satisfaction with it was low, and the general practice at construction sites was to use windows assembled on site rather than integrated window systems manufactured at factories, thus making it difficult to confirm that the current rating system was well applied on site. Consequently, the reality of industrial sites must be reviewed and a realistic alternative to the fenestration energy consumption efficiency rating system must be presented instead of focusing on theory.