• Title/Summary/Keyword: System performance test

Search Result 7,389, Processing Time 0.052 seconds

Stabilization Performance Test Technique for LAH Turret Driving System (소형무장헬기 회전형 포탑시스템의 안정화추적 성능 시험기법)

  • Nam, Byounguk;Lee, Hojung;Jo, Sihun;Cho, Sunghun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.786-792
    • /
    • 2014
  • In this paper, we propose a novel method which can be applied to test and verify the stabilization-tracking performance of Gun/Turret Driving System(GTDS) for Light Armed Helicopter(LAH). In real system, GTDS is connected to TADS/SMC and drived to aim at the target with 20mm gun. But each equipment is separately developed during exploratory development stage, so GTDS cannot be tested under real system state. We suggest new configuration of test system for evaluating the stabilization-tacking performance, in which TADS and SMC are replaced by vision acquisition unit and processing unit, respectively.

Evaluation of the KASI Detector Performance Test System Using an Andor iKon M CCD Camera

  • Yu, Young Sam;Kim, Jinsol;Park, Chan;Jeong, Woong-Seob;Kim, Minjin;Choi, Seonghwan;Park, Sung-Joon
    • Journal of Astronomy and Space Sciences
    • /
    • v.35 no.3
    • /
    • pp.201-210
    • /
    • 2018
  • The characterization of detectors installed in space- and ground-based instruments is important to evaluate the system performance. We report the development of a detector performance test system for astronomical applications using the Andor iKon M CCD camera. The performance test system consists of a light source, monochromator, integrating sphere, and power meters. We adopted the Czerny-Tuner monochromator with three ruled gratings and one mirror, which covers a spectral range of 200-9,000 nm with a spectral resolution of ~1 nm in the visible region. Various detector characteristics, such as the quantum efficiency, sensitivity, and noise, can be measured in wide wavelength ranges from the visible to mid-infrared regions. We evaluated the Korea Astronomy and Space Science Institute (KASI) detector performance test system by using the performance verification of the Andor iKon-M CCD camera. The test procedure includes measurements of the conversion gain ($2.86e^-/ADU$), full well capacity ($130K\;e^-$), nonlinearity, and pixel defects. We also estimated the read noise, dark current, and quantum efficiency as a function of the temperature. The lowest measured read noise is $12e^-$. The dark current at 223 K was determined to be $7e^-/s/pix$ and its doubling temperature is $5.3^{\circ}C{\pm}0.2^{\circ}C$ at an activation energy of 0.6 eV. The maximum quantum efficiency at 223 K was estimated to be $93%{\pm}2%$. We proved that the quantum efficiency is sensitive to the operating temperature. It varies up to 5 % in the visible region, while the variation increases to 30 % in the near-infrared region. Based on the comparison of our results with the test report by the vendor, we conclude that our performance test results are consistent with those from the vendor considering the test environment. We also confirmed that the KASI detector performance test system is reliable and our measurement method and analysis are accurate.

An Evaluation of Selective Grounding Fault Protective Relaying Technique Performance on the Ungrounded DC Traction Power Supply System (도시철도 직류 비접지 급전계통에서의 선택 지락보호시스템의 성능평가)

  • Jung, Hosung;Kim, Joouk;Shin, Seongkuen;Kim, Hyungchul;An, Taepung;Yun, Junseok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1964-1969
    • /
    • 2012
  • This paper presents to verify the selective grounding fault protective relaying technique for the ungrounded DC traction power supply system. This system selectively blocks fault section when grounding fault occurred. In order to perform this verification, field test facilities have been installed on Oesam substation and Worldcup-Stadium substation, and field test process has been suggested. Also, selective grounding fault protective relaying components and rail voltage reduction device have been tested with the various trial examinations. In order to compare and evaluate performance of the selective grounding fault protective relaying function, field test system was modeled and the system fault simulation results were compared and evaluated with the field test result. Performance of selective grounding fault protective relaying function was evaluated with the above-mentioned process, and the fact that the system recognizes fault section irrespective of insulation between rail and ground and fault resistance from grounding fault.

Test Scheme for Multiple Train Operation of K-AGT System (한국형 경량전철 다중편성시험방안)

  • Cho, Bong-Kwan;Hwang, Hyeon-Chyeol;Ryu, Sang-Hwan;Cho, Hong-Sik
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.684-690
    • /
    • 2008
  • LRT System Application Project is performed for the purpose of technical advancement and stabilization of K-AGT system from the viewpoint of practical use and commercialization. For those purpose, the performance test and evaluation procedure for signaling system have been developed, including the scheme of verifying the performance and function of signaling system under driverless multiple train operation environment. In this paper, multiple train operation scheme in K-AGT test line is presented. Test schemes for maintaining the safety distance between trains, operation scenario considering shunting and turning of train, and dia operation schemes in test line are reviewed while researching test vehicle features, route condition and running pattern. Additional equipments for testing each scheme are also reviewed.

  • PDF

Performance Test of Asynchronous Process of OGC WPS 2.0: A Case Study for Geo-based Image Processing

  • Yoon, Gooseon;Lee, Kiwon
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.4
    • /
    • pp.391-400
    • /
    • 2017
  • Geo-based application services linked with the Open Geospatial Consortium (OGC) Web Processing Service (WPS) protocol have been regarded as an important standardized framework for of digital earth building in the web environments. The WPS protocol provides interface standards for analysis functionalities within geo-spatial processing in web-based service systems. Despite its significance, there is few performance tests of WPS applications. The main motivation in this study is to perform the comparative performance test on WPS standards. Test system, which was composed of WPS servers, WPS framework, data management module, geo-based data processing module and client-sided system, was implemented by fully open source stack. In this system, two kinds of geo-based image processing functions such as cloud detection and gradient magnitude computation were applied. The performance test of different server environments of non-WPS, synchronous WPS 1.0 and asynchronous WPS 2.0 was carried out using 100 threads and 400 threads corresponds client users on a web-based application service. As the result, at 100 threads, performance of three environments was within an adjacent range in the average response time to complete the processing of each thread. At 400 threads, the application case of WPS 2.0 showed the distinguished characteristics for higher performance in the response time than the small threads cases. It is thought that WPS 2.0 contributes to settlement of without performance problems such as time delay or thread accumulation.

The Report on Test Results of CO Fire Extinguishing System ($CO_2$ 소화설비 구성부품 성능시험보고)

  • Kim, Gi-Ok;Lee, Chan-Ju;An, Byeong-Ho
    • Fire Protection Technology
    • /
    • s.14
    • /
    • pp.5-12
    • /
    • 1993
  • This report is explained about test results of carbon dioxide extinguiching system components and pack-age type system (Kits) for automatic fire extinguishing system. A carbon dioxide system may be used to protect one or more hazards or hazards by menas of directional valves. Package system shall be installed to protect hazards within the limitations. The testing program was progressed by three items, external oppearance test, performance test and Total Flooding Fire Extinguishing System test. The object of this report is present the problem which apperar from the analysis of test results.

  • PDF

The Development of Gradient Response CVT for a Small Size Electric Vehicle (소형 전기차량용 구배반응 무단변속기 개발)

  • Kim, Gyu-Sung;Kwon, Young-Woong
    • Journal of Power System Engineering
    • /
    • v.19 no.6
    • /
    • pp.33-38
    • /
    • 2015
  • In this study new CVT(Continuously Variable Transmission) system which is adaptable to a small size electric vehicle is proposed available to gradient response CVT. New pulleys consist of springs adapted driving pulley and driven pulley. At the moment a small electric vehicle drive a slope, new system respond to a gradient as overcoming tensional force of springs. We made prototype of gradient response CVT to test parts performance and travelling performance test. As a result of test, belt pitch diameter varied for high torque direction at the gradient. In the flat travelling, acceleration travelling and gradient travelling performance test, the small electric vehicle with gradient response CVT get improved perfomance than the small electric vehicle with reduction gear.

Development of Anti-Spoofing Equipment Architecture and Performance Evaluation Test System

  • Jung, Junwoo;Park, Sungyeol;Hyun, Jongchul;Kang, Haengik;Song, Kiwon;Kim, Kapjin;Park, Youngbum
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.7 no.3
    • /
    • pp.127-138
    • /
    • 2018
  • Spoofing attacks including meaconing can provide a bogus position to a victim GPS receiver, and those attacks are notably difficult to detect at the point of view on the receiver. Several countermeasure techniques have been studied to detect, classify, and cancel the spoofing signals. Based on the countermeasure techniques, we have developed an anti-spoofing equipment that detects and mitigates or eliminates the spoofing signal based on raw measurements. Although many anti-spoofing techniques have been studied in the literatures, the evaluation test system is not deeply studied to evaluate the anti-spoofing equipment, which includes detection, mitigation, and elimination of spoofing signals. Each study only has a specific test method to verify its anti-spoofing technique. In this paper, we propose the performance evaluation test system that includes both spoofing signal injection system and its injection scenario with the constraints of stand-alone anti-spoofing techniques. The spoofing signal injection scenario is designed to drive a victim GPS receiver that moves to a designed position, where the mitigation and elimination based anti-spoofing algorithms can be successively evaluated. We evaluate the developed anti-spoofing equipment and a commercial GPS receiver using our proposed performance evaluation test system. Although the commercial one is affected by the test system and moves to the designed position, the anti-spoofing equipment mitigates and eliminates the injected spoofing signals as planned. We evaluate the performance of anti-spoofing equipment on the position error of the circular error probability, while injecting spoofing signals.

Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy (태양열 시설원예 난방시스템 장기실증 성능분석 연구)

  • Lee Sang-Nam;Kang Yong-Heack;Yu Chang-Kyun;Kim Jin-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.403-407
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a greenhouse culture facility for reducing heating cost, increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex in Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely investigated by changing the control condition based on the temperature difference which is the most important operating parameter. For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, it is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy (태양열 시설원예 난방시스템 장기실증 성능분석 연구)

  • Lee Sang-Nam;Kang Yong-Heack;Yu Chang-Kyun;Kim Jin-Soo
    • New & Renewable Energy
    • /
    • v.1 no.2 s.2
    • /
    • pp.53-59
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a green-house culture facility for reducing healing cost, Increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex In Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely Investigated by changing the control condition based on the temperature difference which Is the most important operating parameter For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, It is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF