• Title/Summary/Keyword: System Safety Process

Search Result 2,432, Processing Time 0.031 seconds

A Development of Facility Web Program for Small and Medium-Sized PSM Workplaces (중·소규모 공정안전관리 사업장의 웹 전산시스템 개발)

  • Kim, Young Suk;Park, Dal Jae
    • Korean Chemical Engineering Research
    • /
    • v.60 no.3
    • /
    • pp.334-346
    • /
    • 2022
  • There is a lack of knowledge and information on the understanding and application of the Process Safety Management (PSM) system, recognized as a major cause of industrial accidents in small-and medium-sized workplaces. Hence, it is necessary to prepare a protocol to secure the practical and continuous levels of implementation for PSM and eliminate human errors through tracking management. However, insufficient research has been conducted on this. Therefore, this study investigated and analyzed the various violations in the administrative measures, based on the regulations announced by the Ministry of Employment and Labor, in approximately 200 small-and medium-sized PSM workplaces with fewer than 300 employees across in korea. This study intended to contribute to the prevention of major industrial accidents by developing a facility maintenance web program that removed human errors in small-and medium-sized workplaces. The major results are summarized as follows. First, It accessed the web via a QR code on a smart device to check the equipment's specification search function, cause of failure, and photos for the convenience of accessing the program, which made it possible to make requests for the it inspection and maintenance in real time. Second, it linked the identification of the targets to be changed, risk assessment, worker training, and pre-operation inspection with the program, which allowed the administrator to track all the procedures from start to finish. Third, it made it possible to predict the life of the equipment and verify its reliability based on the data accumulated through the registration of the pictures for improvements, repairs, time required, cost, etc. after the work was completed. It is suggested that these research results will be helpful in the practical and systematic operation of small-and medium-sized PSM workplaces. In addition, it can be utilized in a useful manner for the development and dissemination of a facility maintenance web program when establishing future smart factories in small-and medium-sized PSM workplaces under the direction of the government.

Load Transfer Mechanism of the Hybrid Beam-Column Connection System with Structural Tees (T 형강을 사용한 합성골조 보-기둥 접합부의 하중전달 메카니즘)

  • 김상식;최광호
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.823-829
    • /
    • 2002
  • The composite frame system with reinforced concrete column and steel beam has some advantages in the structural efficiency by complementing the shortcomings between the two systems. The system, however has also a lot of problems in practical design and construction process due to the material dissimilarities. Considering these circumstances, this research is aimed at the development of the composite structural system which enables the steel beams to be connected to the R/C columns with higher structural safety and economy. Basically the proposed connection system is composed of four split tees, structural angles reinforced by stiffener, high strength steel rods, connecting plates and shear plates. The structural tests have been carried out to verify the moment transfer mechanism from beam flange to steel rods or connecting plates through the angle reinforced by siffener. The four prototype specimens have been tested until the flange of beam reached the plastic states. From the tests, no distinct material dissimilarities between concrete and steel have been detected and the stress transfer through wide flange beam - structural angle - high strength steel rod or connecting plate is very favorable.

An Structural Design for Cyclone Tower's Connections Using Diagrid System (다이아그리드 구조시스템의 접합부개발과 성능평가)

  • Lee, Se-Jung;Lee, Seong-Hui;Kim, Jin-Ho;Choi, Sung-Mo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.2
    • /
    • pp.105-115
    • /
    • 2010
  • Recently, High-rise building are irregular-shaped to be city landmarks and function as vertical cities to enable the efficient use of land. 3T (Twisted, Tilted & Tapered) designs are being suggested for irregular buildings and studies to develop new structural system have been actively made to satisfy slender shape ratio. In diagrid system, not only gravity load but also lateral load is delivered based on the triangular shape of diagrid, so most of columns are eliminated. Because shearing force is delivered by the axial behavior (tensile/compressive) of diagrid to minimize shearing deformation, the system is more applicable to irregular buildings than existing system where shearing force is delivered by the columns. In this study, the process of selecting connection details and the structural safety of the selected details are verified using the finite element analysis with focus given to the construction overview of the Cyclone Tower. However, the relersed methods of stress concentration are suggested and the performance of stress concentration relieves that it's suggested for the appropriate cap plate thickness and extended length.

  • PDF

Economic Evaluation System for Deteriorated Military Facilities (노후 군시설물의 경제성 평가 시스템)

  • Jang, Won-Suk;Lim, Tae-Kyung;Lee, Dong-Eun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.2
    • /
    • pp.181-192
    • /
    • 2013
  • Given both structural safety and economic benefits of aging facilities, remodelling of the existing facilities is preferable to reconstruction. This recognition provides an opportunity to reduce the commitment of resources and national budget. However, when a subordinate troop asks for remodeling or reconstruction of a deteriorated facility, it is difficult to ensure the consistency and objectivity in the process of decision making for the alternatives due to the absence of systematic and quantitative rating methodology. Their economic evaluation methodology only exists in a manual format. Thus, further research is required for converting the methodology into an automated system in view of practicality such as rapid and accurate data processing. The contributions of this study are as follows: 1) Literature review found out a representative economic evaluation model focused on military facilities, and comparative analysis with a similar study identified the strength and weakness. 2) this study presented how to convert the theoretical framework which enables to solve a specific subject matter into an automated system. 3) it developed a user friendly interfaces which consist of four functional modules by considering the usability and accessibility of the system user. 4) the developed system was verified by a case study in terms of four kinds of performance indicators.

Bio-Sensing Convergence Big Data Computing Architecture (바이오센싱 융합 빅데이터 컴퓨팅 아키텍처)

  • Ko, Myung-Sook;Lee, Tae-Gyu
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.7 no.2
    • /
    • pp.43-50
    • /
    • 2018
  • Biometric information computing is greatly influencing both a computing system and Big-data system based on the bio-information system that combines bio-signal sensors and bio-information processing. Unlike conventional data formats such as text, images, and videos, biometric information is represented by text-based values that give meaning to a bio-signal, important event moments are stored in an image format, a complex data format such as a video format is constructed for data prediction and analysis through time series analysis. Such a complex data structure may be separately requested by text, image, video format depending on characteristics of data required by individual biometric information application services, or may request complex data formats simultaneously depending on the situation. Since previous bio-information processing computing systems depend on conventional computing component, computing structure, and data processing method, they have many inefficiencies in terms of data processing performance, transmission capability, storage efficiency, and system safety. In this study, we propose an improved biosensing converged big data computing architecture to build a platform that supports biometric information processing computing effectively. The proposed architecture effectively supports data storage and transmission efficiency, computing performance, and system stability. And, it can lay the foundation for system implementation and biometric information service optimization optimized for future biometric information computing.

Analysis of Operation System Establishment Cases for Efficient use of Risk Assessment at Construction Sites - H Focusing on Construction Company Cases (건설현장의 위험성평가 효율적 활용을 위한 운영 시스템 구축사례 분석 - H 건설사 사례중심으로)

  • Jae-Bung Lee
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.4
    • /
    • pp.828-838
    • /
    • 2022
  • Purpose: Through the establishment of a computerized system of risk assessment, the purpose is to analyze the case of whether the co-workers who are subject to the risk assessment at the construction site can easily fill it out and expect disaster reduction through efficient risk assessment activities. Method: By providing the risk factors and safety measures for the work by selecting the type of work, the risk estimation and the establishment of countermeasures can be made, and a system has been established to enable practical disaster prevention activities by presenting disaster cases for the work. Result: Through the analysis of the change in the scaled disaster rate for the years following the on-site application after the establishment of the risk assessment computer system of H Construction Company, it was confirmed that the scaled disaster rate of the domestic construction industry increased, while the conversion disaster rate of H Construction Company decreased. Conclusion: Through the computational systemization of risk assessments, workers in the field can easily access the risk assessment, evaluate the risk factors of the process and establish risk prevention measures, and it has been analyzed that there is an impact on the reduction of the disaster rate during the operational analysis period.

Monitoring on Microbiological Contamination of Packed Ice Creams from Manufacturing Factories in Korea (국내 제조공장에서 생산된 아이스크림류의 미생물학적 오염실태 조사)

  • Heo, Eun-Jeong;Ko, Eun-Kyung;Kim, Young-Jo;Seo, Kun-Ho;Park, Hyun-Jung;Wee, Sung-Hwan;Moon, Jin San
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.3
    • /
    • pp.202-206
    • /
    • 2014
  • In this study, the bacteriological survey was examined on ice creams at manufacturing factories in Korea during the summer season of 2011. The nineteen selected among 166 samples by preliminary test were collected from 11 different manufacturing factories in four major manufacturers in May 2011. Samples from ice milk, ice creams, sherbets, and non milk fat ice creams were tested for the total aerobic bacteria, coliform bacteria, and five food borne pathogens, respectively. The results showed that the coliforms including E. coli O157:H7, Salmonella spp., Staphylococcus aureus, Clostridium perfringens, and Listeria monocytogenes were not detected on all the ice creams. The total aerobic bacteria of the packed samples examined ranged between $2.5{\times}10^3$ and $5.5{\times}10^5cfu/g$. One ice cream, two sherbets, and four ice milk samples exceeded the acceptable limits of total aerobic bacteria according to the Korean standards for ice cream ($1.0{\times}10^5cfu/g$) and others ($5.0{\times}10^4cfu/g$). The levels of these microorganisms from ice creams were higher in three original equipment manufacturers than seven self-manufacturers. Three of ten ice creams (30.0%), three of six ice milks (50.0%), and one of two sherbets (50%) exceeded the acceptable limits of total aerobic bacteria, respectively. The personnel hygiene procedures with chocolate and vanilla chip addition from the manufacturing process were the main sources of the microbial contamination of stick-bar type ice creams when being produced in a factory. Improvement of the hazard analysis critical control points (HACCP) system should be introduced into the ice cream factory to improve the microbial quality of the ice cream products in Korea.

Microbiological Safety Assessment to Secure Safety of Food Service in University (대학 내 급식소의 안전성 확보를 위한 미생물학적 안전성 평가)

  • Kim, Kyeong-Yeol;Nam, Min-Ji;Nam, Bo-Ram;Ryu, Hee-Jung;Heo, Rok-Won;Shim, Won-Bo;Chung, Duck-Hwa
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.1
    • /
    • pp.49-58
    • /
    • 2010
  • The objectives of this study were to investigate the microbial contamination levels on food service in university and to provide the information of microbial contamination to improve food safety. A total of 288 samples were collected during summer and winter season between 2006 and 2008 from 4 food services located in the university in Western Gyeongnam and were used to detect sanitary indicator bacteria [aerobic plate count (APC), coliform, and Escherichia coli] and pathogenic bacteria (Staphylococcus aureus, Salmonella spp.). As a result, APC and coliform for hand and kitchen utensils which are used often by the employee were detected at high levels of 1.1~5.5 and 1.3~5.3 log CFU/($100\;cm^2$, hand), respectively. The contamination levels of APC and coliform in cooked foods and drinking water were 0.8~6.4 and 1.3~5.0 log CFU/(g, mL), respectively. Especially, the cooked foods showed the highest contamination for APC (2.1~6.4 log CFU/g) and coliform (1.0~5.0 log CFU/g). We think the reason that the cooked foods may be contaminated with APC and coliform on cooking process by using employee's hand and kitchen utensils. Moreover, S. aureus for hand and kitchen utensils was detected at levels of 2.8~3.0 and 2.0~2.3 log CFU/(g, hand), but Salmonella spp. was not detected. According to the above results, contamination levels of the samples were mostly decreased irrespective of summer and winter season. The results obtained indicated that it is necessary to periodic monitoring for microorganism contamination and education about personal and environmental hygiene to employee for ensuring food safety of food service in university.

Measurement of Nursing Service Quality using SERVQUAL Model (SERVQUAL 모델을 이용한 간호 서비스 질 측정)

  • Lim, Ji-Young;Kim, So-In
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.6 no.2
    • /
    • pp.259-279
    • /
    • 2000
  • This study is a descriptive analytic research measuring nursing service quality, using SERVQUAL model, to make fundamental data and strategies for nursing service improvement. Data were collected by self-reported questionnaire from 202 patients and 142 nurses, from June 7 to 14, 1999. The reliability of instrument were adequate(Cronbach ${\alpha}=.94$). SAS program was utilized for statistical analysis of collected data. The results were as follows; 1. There was a gab between patient's expectation and perception on nursing service(Gap B). Gap D was indicated an affecting factor to decide nursing service quality. Gap C was indicated an indirect affecting factor of nursing service quality. Because it was not statistically significant in total item analysis, but in individual item analysis, 7 items were appeared statistically significant. Gap A was not a gap occurrence factor of nursing service quality. 2. Focuses of nursing service quality improvement strategies were; (1) to direct qualitative improvement of nursing service in order to correspondence patient's nursing service expectation. (2) to make nurse's service activity modified because nurse's practice were not reached patient's expectation level. (3) to need internal, external factor analysis affecting nurse's service activity. 3. Nursing service quality was decided by rather environmental inappropriateness provided nursing service than itself. Therefore, to make nursing service quality improvement, it is required to improve nursing service environment. For this, followings are required; (1) to strengthen nurse's education on lower part of nursing service satisfaction and QI activities. (2) to balance demand and supply of nursing personnel. 3) to fix computerized system for reducing other duties weight except nursing care through analysis of nursing activity. (4) to construct rational cooperating system among related departments. 4. The important parts for nursing service quality improvement were indicated as follows: (1) Gap B: 'prompt reaction', 'examination symptom before patient's complaint', 'hearted nursing service reducing patient's dissatisfaction', 'explanation goals of nursing activities', 'having special Knowledge enough', 'maintenance position comfortably', 'management of patient's physical hygiene'. (2) Gap C: 'maintenance physical safety', 'explanation about hospital rules and facilities'. (3) Gap D: 'tender, safe injection and wound care'. Because above items are mostly improved through nurse's attitude change and quality improvement, it is required to establish nursing standardization and to strengthen nurse's clinical education. As the based on above results, followings are suggested; 1. SERVQUAL model is very useful to make strategies for nursing service quality improvement because it indicates multiple factors affecting hap occurrence. 2. At individual items analysis of Gap C, statistically significant 7 items appeared higher nurse's perception level than patient's perception level on nursing service were trouble perception level on nursing service quality improvement. So. it need further research to analysis about these difference occurring factors. 3. At analysis of Gap D, it is indicated that in nursing service performance process, multiple factors lowing nursing service quality were intruded. So it needs further research to analysis what these factors are and how each factors affect on nursing performance process. 4. nursing service quality measurement is changeable according to sample select time or sampled subject's characteristics. So to develope strategy for nursing service quality improvement is based on the results of periodical analysis.

  • PDF

Characteristics of Disinfection Byproducts in Tap Water of Seoul (서울시 수돗물 배급수 계통에서 소독부산물 분포특성)

  • Chang, Hyun Seong;Lee, Do Weon;Kim, Chang Mo;Lee, In Suk;Lee, Su Won;Park, Hyeon
    • Korean Chemical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.216-226
    • /
    • 2006
  • Total trihalomethanes (THMs), dichloroacetic acid (DCAA) and trichloroacetic acid (TCAA) that are the major disinfection byproducts (DBPs) are monitored continuously in drinking water in Seoul. Study on characteristics of DBPs is crucial to judge the safety of drinking water in Seoul. Analysis of THMs, haloacetonitriles (HANs), chloral hydrate (CH), and haloacetic acids (HAAs) was carried out in several distribution systems from January 2002 to December 2004. The concentration of THMs was 0.015 mg/L in purified water, 0.019 mg/L in tapwater by direct service, and 0.023 mg/L in tapwater through watertank, respectively. It might be due to the increased contact time with chlorine by a process of the distribution system. And the other DBPs show a tendency to increase in its concentration by a process of the distribution system. Also, in summer, the concentration of DBPs was higher than in spring and winter. It might be due to the higher temperature of water in summer. In all cases, the quantities of detected DBPs were 4-6 times lower than those of regulation limits of drinking water in Seoul. In view of these results, the tapwater in Seoul is good to drink it all the times.