• Title/Summary/Keyword: System Reset

Search Result 159, Processing Time 0.026 seconds

Development of 8kW ZVZCS Full Bridge DC-DC Converter by Parallel Operation (병렬제어를 적용한 8kW급 영전압/영전류 풀 브릿지 DC-DC 컨버터 개발)

  • Rho, Min-Sik
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.400-408
    • /
    • 2007
  • In this paper, development of the 8kW parallel module converter is presented. For a effective configuration of FB-PWM converter, this paper proposes 4-parallel operation of 2 kw-module. FB converter of 2-kW module is controlled by phase shut PWM and in order to achieve ZVZCS, the simple auxiliary circuit is applied in secondary side. In order to achieve ZCS, control logic for auxiliary circuit operation is designed to reset the primary current during free-wheeling period. For output current sharing of 4-modules, the charge control is employed. The charge control logic is designed with phase shift PWM logic. Voltage controller is implemented by using DSP(TMS320LF2406) with A/D conversion data of the output current and voltage of each module. The developed converter is installed in PCU(Power Conditioning Unit) for HSG(High Speed Generator) in a vehicle and health monitoring system is implemented for vehicle operation test. Finally, performance of the developed converter is proved under practical operation of HSG.

Virtuality in Digital Fashion Images (디지털 패션영상에 나타난 가상성 연구)

  • Kim, Hyang-Ja;Kim, Young-Sam
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.39 no.2
    • /
    • pp.233-246
    • /
    • 2015
  • Focus on Digital Fashion Image, the conceptual framework for the thesis is established from Virtuality in Digital Art. Formative characteristics and aesthetic characteristics were studied by classifying the Digital Fashion Image applied and expressed by digital media and technology. A detective research method was used for a case study. A literature study for case-by-case data was analyzed with focus on the works expressing fashion that utilized digital media and technology since the 2000s. Through this study, the Digital revolution has created the socio-cultural impact of a Virtual representation to implement technology and fashion culture that finds ways to take advantage of the image shown in a Digital Fashion Media by understanding Virtuality. The results are as follows. First, it was a re-formation of the fashion culture through the experience of virtuality with mental zone parameters between the media 'Mediation Code'. Reflect the reality of the virtual environment as represented by a cultural image of fashion brands and fashion that reset the team relationship and formed a Homo Ludens cultural code. Second, 'Interactive Exchange' acts on the exchange interaction between the method of digital technology, the human and the machine as well as the technical interoperability of network elements and techniques. This exchange is applied to fashion images that express emotion. Forming personalized fashion items and the user interactively storage that expresses the interactive exchange to forward the identity of the emotional fashion by a change in the message delivery system fashion. Third, the emphasis on intuitive artistic expression 'Synesthesia Immersion' induces a sense of immersion and excitement through the fusion of the interconnected. Enhance a visual image in fashion sensory representation and maximize a tactile and visual virtual reality involvement.

A Study of Improvement on the responsiveness of Digital AVR System (Digital 자동전압조정장치(AVR)의 속응성 향상에 관한 연구)

  • Kim, Song-hyun;Lee, Hyung-ki;Choe, Wook-yeon;An, Young-joo;Kim, Hyun-soo;Kim, Gi-Ryang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.246-247
    • /
    • 2015
  • Type of Automatic Voltage Regulator (AVR) can be divided into Analog and Digital Type. Automatic Voltage Regulator (AVR) of the synchronous generators of the brushless type are to be reduced to the voltage fluctuation on the basis of the total load. The PID control method is a general control technique is commonly widely used. In this study, the control target parameter iPID does not reset the parameters of the controller for the variable (Intelligent PID) using the controller synchronous generator Digital automatic voltage to you like all applied to the adjusting device (AVR) the voltage change is small, improved responsiveness was studied in this controller.

  • PDF

An Integrated Approach to Realize Multi-resolution of B-rep Model (B-rep의 다중해상도를 구현하는 통합 시스템 개발)

  • Kim, S.C.;Lee, K.W.;Hong, T.S.;Kim, M.C.;Jung, M.K.;Song, Y.J.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.11 no.4
    • /
    • pp.289-302
    • /
    • 2006
  • It is becoming a common trend that many designers work on a very complex assembly together in a collaborative environment. In this environment, every designer should be able to see the whole assembly in a full detail or in a rough shape at least. Even though the hardware technology is being improved very rapidly, it is very difficult to display a very complex assembly at a speed to allow smooth interactions for designers. This problem could be solved if a designer could manipulate his portion of the assembly in a full resolution while the remaining portion of the assembly is displayed in a rough resolution. It is also desired that the remaining portion is converted to the full resolution when needed. To realize this environment, the capabilities to simplify the portions of an assembly and to reset to the original resolution should be added to the current CAD systems. Thus operators realizing multi-resolution on B-rep are proposed in this paper. They are: wrap-around, smooth-out, and thinning operator. Through appropriately applying these operators sequentially, an assembly model of any desired resolution can be easily generated. Of course, the assembly can go back to the finer resolution. In this paper, the data structures and the processes to realize these operators are described and a prototype modeling system with these operators is also demonstrated.

Extraction of the Key Performance Indicators of Construction Management Using Balanced Score Card (균형성과표를 활용한 건설사업관리의 핵심성과지표 도출)

  • Lim, Wooseok;Jung, Jihyun;Lee, Hakki
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.6
    • /
    • pp.22-30
    • /
    • 2015
  • Enterprises should set up realizable goals and continually control the goals from apprehending whether they can be realized or not so that the enterprises grow consistently. Furthermore, from supplementing parts to be improved, goals are reset and the result should be controlled in order to fit to them. Lately, a lot of discussions about the results of organizations, projects, and companies are being realized in construction field. Particularly, in construction management, effective and professional control activities throughout the life cycle of facilities as well as the stage of business implementation of construction work are needed. About the result measurement of the construction management, lots of most domestic researches stay in the level of establishing basic concepts. Also, since characteristics of the construction field and the construction management were not reflected properly, it is in a situation that the result control system is not applied to on-site real works. Hence, this study intends to suggest fundamental data for measuring objective results from extracting result areas and key performance indicators of the construction management using Balanced Score Card.

Study of Modulation Effect in Integrated Interface Under Controlling Switching Light-Emitting Diode Lighting Module

  • Hong, Geun-Bin;Jang, Tae-Su;Kim, Yong-Kab
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.6
    • /
    • pp.253-257
    • /
    • 2011
  • This study was carried out to solve problems such as radio frequency band depletion, confusion risk, and security loss in existing visible wireless communication systems, and to determine the applicability of next-generation networks. A light-emitting diode (LED) light communication system was implemented with a controlling switching light module using the ATmega16 micro-controller. To solve the existing modulation effect and disturbance in visible light communication, an integrated interface was evaluated with a driving light module and analyzes its reception property. A transmitter/receiver using the ATmel's micro-controller, high-intensity white LED-6 modules, and infrared sensor KSM60WLM and visible sensor TSL250RD were designed. An experiment from the initial value of distance to 2.5 m showed 0.46 V of the voltage loss, and if in long distance, external light interference occurred and light intensity was lost by external impact and thus data had to be modified or reset repeatedly. Additionally, when we used 6 modules through the remote controller's lighting dimming, data could be transmitted up to 1.76 m without any errors during the day and up to 2.29 m at night with around 2~3% communication error. If a special optical filter can reduce as much external light as possible in the integrated interface, the LED for lighting communication systems may be applied in next generation networks.

Performance Improvement of SCAM Climate Model using PGI Compiler with OpenACC (SCAM 기상모델의 성능향상을 위한 PGI Compiler의 OpenACC 활용)

  • Lee, Chang-Hyun;Kang, Bol-Kyung;Chung, Sung-Wook
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.3
    • /
    • pp.189-197
    • /
    • 2022
  • With the development of high-performance computing technology and the advancement of numerical model, it is possible to predict the better weather forecasting. The purpose of this paper is the performance improvement for the SCAM climate model for the model running time excluding the compilation time. Therefore, the model previously performed using the Intel Fortran Compiler was changed to PGI Fortran Compiler. To this end, we reconfigure system environment variables, reset compilation options, install dependencies SW and library, and modify source code. In addition, we proposed and applied the 'PGI Compile with OpenACC' method. As a result, when the compiler was changed from intel to PGI, it led to an improvement of 6.08% in running time and when the openACC method was applied, it led to an improvement of 43.05% in running time. This demonstrates that the PGI Compile with OpenACC method proposed in this paper leads to excellent performance.

Assessment of acute inhalation toxicity of citric acid and sodium hypochlorite in rats

  • Jinhee Kim;Chul-Min Park;Su Hyun Choi;Mi Jin Yang;Ju-Yeon Lee;Byung-Suk Jeon;Hyun-Ok Ku;Min-Seok Kim
    • Journal of Veterinary Science
    • /
    • v.24 no.2
    • /
    • pp.22.1-22.12
    • /
    • 2023
  • Background: Citric acid (CA) and sodium hypochlorite (NaOCl) have been used to disinfect animals to protect them against avian influenza and foot-and-mouth disease. Objectives: We performed a good laboratory practice (GLP)-compliant animal toxicity study to assess the acute toxic effects of CA and NaOCl aerosol exposure in Sprague-Dawley rats. Methods: Groups of five rats per sex were exposed for 4 h to four concentrations of the two chemicals, i.e., 0.00, 0.22, 0.67, and 2.00 mg/L, using a nose-only exposure. After a single exposure to the chemicals, clinical signs, body weight, and mortality was observed during the observation period. On day 15, an autopsy, and then gross findings, and histopathological analysis were performed. Results: After exposure to CA and NaOCl, body weight loss was observed but recovered. Two males died in the CA 2.00 mg/L group and, two males and one female died in the 2.00 mg/L NaOCl group. In the gross findings and histopathological analysis, discoloration of the lungs was observed in the CA exposed group and inflammatory lesions with discoloration of the lungs were observed in the NaOCl exposed group. These results suggest that the lethal concentration 50 (LC50) of CA is 1.73390 mg/L for males and > 1.70 mg/L for females. For NaOCl, the LC50 was 2.22222 mg/L for males and 2.39456 mg/L for females. Conclusions: The Globally Harmonized System is category 4 for both CA and NaOCl. In this study, the LC50 results were obtained through a GLP-based acute inhalation toxicity assessment. These results provide useful data to reset safety standards for CA and NaOCl use.

Design of a Delayed Dual-Core Lock-Step Processor with Automatic Recovery in Soft Errors (소프트 에러 발생 시 자동 복구하는 이중 코어 지연 락스텝 프로세서의 설계)

  • Juho Kim;Seonghyun Yang;Seongsoo Lee
    • Journal of IKEEE
    • /
    • v.27 no.4
    • /
    • pp.683-686
    • /
    • 2023
  • In this paper, we designed a Delayed Dual Core Lock-Step (D-DCLS) processor where two cores operate same instructions with delay and the result is compared to mitigate soft errors and common mode failures in automotive electronic systems. Because D-DCLS does not know which core an error occurred in, each core must be recovered to the point before the error occurred, but complex hardware modifications are required to return all intermediate values on the pipeline stage. In this paper, in order for easy hardware implementation, all register values are saved to a buffer whenever a branch instruction is executed. When an error is detected, the saved register values are automatically restored, and then 'BX LR' instruction is executed to return to the last branch point. The proposed D-DCLS processor was designed using Verilog HDL and was confirmed to continue normal operation after automatically recovering error.

Landslide Risk Assessment Using HyGIS-Landslide (HyGIS-Landslide를 이용한 산사태 발생 위험도 평가)

  • Park, Jung-Sool;Kim, Kyung-Tak;Choi, Yun-Seok
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.15 no.1
    • /
    • pp.119-132
    • /
    • 2012
  • Recently, forest soil sediment disasters resulting from locally concentrated heavy rainfall have been occurring frequently in steep slope areas. The importance of landslide hazard map is emerging to analyze landslide vulnerable areas. This study was carried out to develop HyGIS-Landslide based on Hydro Geographic Information System in order to analyze forest soil sediment disaster in the mountainous river basin. HyGIS-Landslide is one of HyGIS components designed by considering the landslide hazard criteria of Korea Forest Service. It could show the distribution of landslide hazard areas after calculating the spatial data. In this system, the user could reset the weight of hazard criteria to reflect the regional characteristics of the landslide area. This component provided user interface that could make the latest spatial data available in the area of interest. HyGIS-Landslide could be applied to the surveyor's compensation score and it was possible to reflect the landslide risk exactly through it. Also, it could be used in topographic analysis techniques providing spatial analysis and making topographical parameters in HyGIS. Finally the accuracy could be acquired by calculating the landslide hazard grade map and landslide mapping data. This study applied HyGIS-Landslide at the Gangwon-do province sample site. As a result, HyGIS-Landslide could be applied to a decision support system searching for mountainous disaster risk region; it could be classified more effectively by re-weighting the landslide hazard criteria.