• Title/Summary/Keyword: System Recovery

Search Result 3,169, Processing Time 0.036 seconds

A Study on Energy Reduction in an Outdoor Air Conditioning System for Semiconductor Manufacturing Cleanrooms Using Water Spray Humidification (반도체 클린룸용 외기공조시스템의 수분무 가습을 이용한 에너지절감에 관한 연구)

  • Song, Won-Il;Kim, Ki-Cheol;Yoo, Kyung-Hoon;Shin, Dae-Kun;Tae, Kyung-Eung;Kim, Yong-Sik;Park, Dug-Jun
    • Particle and aerosol research
    • /
    • v.13 no.2
    • /
    • pp.65-77
    • /
    • 2017
  • In recent large-scale semiconductor manufacturing cleanrooms, the energy consumption in outdoor air conditioning (OAC) systems to heat, humidify, cool and dehumidify outdoor air(OA) represents about 40~50 % of the total cleanroom power consumption required to maintain cleanroom environment. Therefore, the assessment of energy consumption in outdoor air conditioning systems is essential for reducing the outdoor air conditioning load for a cleanroom. In the present study, an experiment with an outdoor air flow rate of $1,000m^3/h$ was conducted to compare the energy consumption in steam humidification, simple air washer, exhaust air heat recovery type air washer and dry cooling coil(DCC) return water heat recovery type air washer OAC systems. Besides, a numerical analysis was carried out to evaluate the annual energy consumption of the aforementioned four OAC systems. It was shown that the simple air washer, exhaust air heat recovery type air washer and DCC return water heat recovery type air washer OAC systems using water spray humidification were more energy-efficient than the steam humidification OAC system. Furthermore the DCC return water heat recovery type air washer OAC system was the most energy-efficient.

A Study of Recovery Standards and Post-Evaluation Method for Long Term Community Preventive Recovery Plan (개선복구계획 수립기준 및 효과측정 연구)

  • Jung, Woo-Young;Jung, Sang-Man;Choi, Hyun-Kyu;Lee, Sang-Moon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.2
    • /
    • pp.31-37
    • /
    • 2009
  • Most damages of civil infrastructures under natural disasters are frequently occurred at surrounding areas of the river or the road. Every year, Recovery for these disaster damages are performed by the government. Recently, the government decide to change current recovery plan system because current recovery plan which doesn't consider future disaster impacts at a site has been proved to be ineffective. Accordingly, new permanency recovery plan system is needed and its corresponding ideas are presented in this research considering more detailed disaster damage classifications and cause assessments. The proposed permanency recovery plan would also provide more systematic and diverse recovery response strategies including both two concepts, for example Preparedness considered by risk assessment and management, and Mitigation investigated by hazard impact analyses.

A backward recovery method for web service driven business process management (웹 서비스 기반 비즈니스 프로세스 관리를 위한 Backward Recovery 방법)

  • 이순재;윤장혁;김광수
    • Proceedings of the CALSEC Conference
    • /
    • 2003.09a
    • /
    • pp.109-114
    • /
    • 2003
  • WS-BPMS(web service driven business process management system)은 기업 내 또는 비즈니스 파트너들 간의 비즈니스 프로세스를 체계적으로 통합, 관리하여 프로세스를 개선하고 자동화한다. 이는 비즈니스 프로세스를 검색한 후 BPEL4WS, BPML 등의 프로세스 메타모델을 이용하여 새 프로세스를 디자인하고 BPMS위에 전개 실행하는 과정을 거치게 된다. 디자인된 프로세스는 복잡하여 그 실행에 있어 체계적이고 확고한 기반을 바탕으로 운영되어야 한다. 이를 위해 본 논문에서는 BPMS의 운영에 있어 pi-calculus를 기반으로 한 structured exception handling 방법론과 transaction 모니터링을 통한 backward recovery 방법을 제시한다.

  • PDF

Study on Heat Recovery System using Waste Biomass (폐 바이오매스를 이용한 폐열 회수 열교환기에 관한 연구)

  • Lee Chung-Gu;Lee Se-Kyoun;Lee Kye-Bock;Rhi Seok-ho;Ryou In-Seon
    • Journal of Energy Engineering
    • /
    • v.14 no.4 s.44
    • /
    • pp.248-258
    • /
    • 2005
  • In the present study, in order to estimate possibility as a waste heat recovery system, three different heat exchangers are developed. The developed heat exchangers are tile system to supply the hot water using fermentation of waste biomass. For the experiments, various biomass materials were examined to obtain the best heat recovery. Waste heat recovery system was studied numerically and experimentally. Heat exchanger system was designed specially to obtain the optimum heat exchanging performance. The biomass heat exchanger was operated for 20 minutes, after 1 hour from start-up, the temperature of the biomass dump has been raised to the possible operation temperature. From the three time operations per day, the system would be able to supply the amount of energy, about 62,400 kcal/day.

A Compressed Sensing-Based Signal Recovery Technique for Multi-User Spatial Modulation Systems (다중사용자 공간변조시스템에서 압축센싱기반 신호복원 기법)

  • Park, Jeonghong;Ban, Tae-Won;Jung, Bang Chul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.7
    • /
    • pp.424-430
    • /
    • 2014
  • In this paper, we propose a compressed sensing-based signal recovery technique for an uplink multi-user spatial modulation (MU-SM) system. In the MU-SM system, only one antenna among $N_t$ antennas of each user becomes active by nature. Thus, this characteristics is exploited for signal recovery at a base station. We modify the conventional orthogonal matching pursuit (OMP) algorithm which has been widely used for sparse signal recovery in literature for the MU-SM system, which is called MU-OMP. We also propose a parallel OMP algorithm for the MU-SM system, which is called MU-POMP. Specifically, in the proposed algorithms, antenna indices of a specific user who was selected in the previous iteration are excluded in the next iteration of the OMP algorithm. Simulation results show that the proposed algorithms outperform the conventional OMP algorithm in the MU-SM system.

A Study on the Release Characteristics of VOCs from Heat Recovery Ventilation System (폐열회수형 환기장치의 휘발성유기화함물 배출 특성에 관한 연구)

  • Kwak, Kyung-Min;Bai, Cheol-Ho;Kim, Jee-Yong;Chu, Euy-Sung
    • Clean Technology
    • /
    • v.13 no.4
    • /
    • pp.281-286
    • /
    • 2007
  • VOCs from the heat recovery ventilation system (total heat exchanger) are measured in this study. Two different types of element (L and M type) from heat recovery ventilating system are tested to study the intial release characteristics of VOCs under KS cooling and heating standard conditions. VOCs are measured for the various flow rates and different operating times. Considering errors in the test method and the measuring instrument, the tested heat recovery ventilating systems was found to release 6 major VOCs, such as acetic acid, 2-butanone (MEK), 2-(methylthio )ethylamine, toluene, styrene, and x-acids (Ion 57). The concentrations of released VOCs are not quite much affected by operating conditions. The results show much larger VOCs concentrations in the cooling mode than in the heating mode, due to the high operating temperatures.

  • PDF

Real-Time File Integrity Checker for Intrusion Recovery and Response System (침입 복구 및 대응 시스템을 위한 실시간 파일 무결성 검사)

  • Jeun Sanghoon;Hur Jinyoung;Choi Jongsun;Choi Jaeyoung
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.32 no.6
    • /
    • pp.279-287
    • /
    • 2005
  • File integrity checking is the most reliable method to examine integrity and stability of system resources. It is required to examine the whole data whenever auditing system's integrity, and its process and result depends on administrator's experience and ability. Therefore the existing method is not appropriate to intrusion response and recovery systems, which require a fast response time. Moreover file integrity checking is able to collect information about the damaged resources, without information about the person who generated the action, which would be very useful for intrusion isolation. In this paper, we propose rtIntegrit, which combines system call auditing functions, it is called Syswatcher, with file integrity checking. The rtlntegrit can detect many activities on files or file system in real-time by combining with Syswatcher. The Syswatcher audit file I/O relative system call that is specified on configuration. And it can be easily cooperated with intrusion response and recovery systems since it generates assessment data in the standard IDMEF format.

Stabilization technology of biogas plant applied recovery system (Recovery system 적용을 통한 바이오가스플랜트의 안정화 기술)

  • Jang, Byoungin;Jeoung, Mihwa;Cho, Yoonmi;Jo, Yongil;Park, Kyungho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.102.2-102.2
    • /
    • 2010
  • We are to evaluate the stabilization technology of actual biogas plant facilities, which is operating currently. It describes the traits of the consistent facilities of mesophilic anaerobic digestion using Unison Biogas plant Recovery system(UBR). Also the economical efficiency is examined with the electric power sales earnings and applying the deserted heating by generating electric power, which is generated by operated combined heat and power using biogas produced by mesophilic anaerobic digestion. We have generated the 481,113kw for electric power and 1,376Gcal for thermal energy simultaneously. If these electric power and thermal energy are converted into diesel, we can achieve savings equal to 114,300L, and 152,109L in the quantity of heat. Finally, if CDM, RPS, liquid fertilizer sales business, etc. is activated, the earnings will be expected to improve dramatically and is considered to contribute a drop of the greenhouse gas.

  • PDF

Recovery Management of Split-Brain Group in Highly Available Cluster file System $\textrm{SANique}^{TM}$ (고가용성 클러스터 파일 시스템 $\textrm{SANique}^{TM}$의 분할그룹 탐지 및 회복 기법)

  • 이규웅
    • Journal of Korea Multimedia Society
    • /
    • v.7 no.4
    • /
    • pp.505-517
    • /
    • 2004
  • This paper overviews the design details of the cluster file system $\textrm{SANique}^{TM}$ on the SAN environment. $\textrm{SANique}^{TM}$ has the capability of transferring user data from shared SAN disk to client application without control of centralized file server. We, especially, focus on the characteristics and functions of recovery manager CRM of $\textrm{SANique}^{TM}$. The process component for failure detection and its overall procedure are described. We define the split-brain problem that cannot be easily detected in cluster file systems and also propose the recovery management method based on SAN disk in order to detect and solve the split-brain situation.

  • PDF

Fault Diagnosis and Recovery of a Thermal Error Compensation System in a CNC Machine Tool (CNC 공작기계에서 열변형 오차 보정 시스템의 고장진단 및 복구)

  • 황석현;이진현;양승한
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.4
    • /
    • pp.135-141
    • /
    • 2000
  • The major role of temperature sensors in thermal error compensation system of machine tools is improving machining accuracy by supplying reliable temperature data on the machine structure. This paper presents a new method for fault diagnosis of temperature sensors and recovery of faulted data to establish the reliability of thermal error compensation system. The detection of fault and its location is based on the correlation coefficients among temperature data from the sensors. The multiple linear regression model which is prepared using complete normal data is also used fur the recovery of faulted data. The effectiveness of this method was tested by comparing the computer simulation results and measured data in a CNC machining center.

  • PDF