• Title/Summary/Keyword: System Performance Analysis

Search Result 14,435, Processing Time 0.044 seconds

Investigation of Validation Guidelines for Performance Verification of High Performance Liquid Chromatograph (고성능 액체크로마토그래프 기기의 성능검증을 위한 밸리데이션 가이드라인에 대한 연구)

  • Yun, Won Nam;Lee, Beom-Gyu;Lee, Wonjae
    • YAKHAK HOEJI
    • /
    • v.57 no.5
    • /
    • pp.362-368
    • /
    • 2013
  • High performance liquid chromatograph (HPLC) is the most frequently used analytical instrument in analytical laboratories for pharmaceutical analysis. In order to provide a high level of assurance for reliable data generated from the HPLC analysis, the performance qualification of the HPLC system is required. For this purpose, the performance of HPLC system should be regularly monitored by examining the key functions of the typical HPLC system (solvent delivery system, injector system, column oven, UV-VIS detector system). We have investigated the validation guidelines of the performance verification of these key modules for HPLC system. And we proposed and evaluated its validation guidelines and the related verification methods for pharmaceutical analysis that could be practically applied in Korea.

Photovoltaic System Energy Performance Analysis Using Meteorological Monitoring Data (기상 환경 모니터링 데이터를 이용한 태양광발전시스템 발전량 성능 분석)

  • Kwon, Oh-Hyun;Lee, Kyung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.4
    • /
    • pp.11-31
    • /
    • 2018
  • Nowadays, domestic photovoltaic system market has been expanded and the governmental dissemination policy has been continued. There is only PV system output performance analysis which is called Performance Ratio(PR) analysis. However, there exists many parameters that can affect PV system output. This papers shows the PV system energy performance analysis using meteorological monitoring data. The meteorological monitoring system was installed in the H university and we analyzed the PV system which installed in the H university. We also investigated other three PV systems which located less than 3 kilometers from H university. We evaluated total 4 PV systems through the field survey data, design drawing data and power generation data. Finally, we compared the actual measuring data with the simulation data using PVSYST software.

An Analysis of Multi-processor System Performance Depending on the Input/Output Types (입출력 형태에 따른 다중처리기 시스템의 성능 분석)

  • Moon, Wonsik
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.12 no.4
    • /
    • pp.71-79
    • /
    • 2016
  • This study proposes a performance model of a shared bus multi-processor system and analyzes the effect of input/output types on system performance and overload of shared resources. This system performance model reflects the memory reference time in relation to the effect of input/output types on shared resources and the input/output processing time in relation to the input/output processor, disk buffer, and device standby places. In addition, it demonstrates the contribution of input/output types to system performance for comprehensive analysis of system performance. As the concept of workload in the probability theory and the presented model are utilized, the result of operating and analyzing the model in various conditions of processor capability, cache miss ratio, page fault ratio, disk buffer hit ratio (input/output processor and controller), memory access time, and input/output block size. A simulation is conducted to verify the analysis result.

A Study on the Performance Analysis of Degasser System with Vacuum Pump for Onshore and Offshore Drilling (육상 및 해양 시추용 디개서 시스템의 진공펌프 성능해석)

  • Kwon, Seong-Yong;Park, Sung-Gyu;Shin, Chul-Soon;Kim, Seung-Chan;Lim, Hee-Yeon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.6_2
    • /
    • pp.1063-1069
    • /
    • 2022
  • In modern industry, vacuum has grown into an indispensable industrial field. The performance of the vacuum pump in the degasser system among mud treatment system facilities was verified by a numerical analysis method. The degasser system is an equipment for removing the gas contained in the mud, and it is a work process that requires a vacuum. This study analyzed the vacuum pump performance of the degasser used in drilling for resource development of onshore and offshore plants. The vacuum pump used in the degasser system was designed with a discharge rate of 0.099kg/s. The DM(Design Modeler) program of ansys workbench 17.2 was used to modify the model of the vacuum pump used in the degasser system. And for performance analysis, CFX, which is known to be suitable for rotating system analysis, was used. Finally the performance analysis results of the vacuum pump and the prototype performance test results were compared and analyzed.

Analysis and evaluation of sound reduction performance of drywall system (건식벽체 차음성능 분석 및 평가)

  • Baek, Seung-Kyung;Chang, Chun-Sang;Go, Jong-Cheol;Lee, Jong-In;Kim, Hyun-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.727-732
    • /
    • 2009
  • The objective of this study is to analyze and evaluate design factors relating to sound reduction performance in dry wall system. The main contents of this study are as follows. 1) Analysis and pre-evaluation of sound reduction performance of drywall system ; The sound reduction performance was pre-evaluated by INSUL simulation and these results of analyzing walls were analyzed by screening DOE(design of experiment) for selecting major factors that dominant influence the sound reduction performance. These main factors relating to sound reduction performance can be used for development of 1st grade sound reduction performance drywall system. 2) Design and evaluation of 1st grade sound reduction performance drywall system; The evaluation test of the sound reduction performance gave vaues higher than 1st grade (Rw+C=64). When campared with existing dry wall system, respectivelly, the new system shows performance higher than 8 dB.

  • PDF

Navigation Performance Analysis of KASS Test Signals

  • Daehee Won;Eunsung Lee;Chulhee Choi
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.4
    • /
    • pp.369-377
    • /
    • 2023
  • This paper presents the analysis results of navigation performance of Korea Augmentation Satellite System (KASS) test signals. Performance analysis was performed with Global Positioning System (GPS) and Satellite Based Augmentation System (SBAS) signals received from 7 KASS reference stations. And the performances were analyzed in terms of the signal strength, statistics for each SBAS message, coverage of ionospheric correction, accuracy, integrity, continuity, and availability. In addition, the navigation solutions provided by commercial receiver was analyzed and the performance experienced by general users was presented. Lastly, directions for further improvement of the KASS system were addressed. These performance analysis results can be used to confirm the feasibility of utilizing KASS in user applications.

Performance Analysis of Refrigeration System Using the CFC-Alternative and Scroll Compressor (CFC-대체냉매와 스크롤압축기를 사용한 냉동시스템 성능해석)

  • Pak, H.Y.;Park, K.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.366-381
    • /
    • 1995
  • A performance analysis of refrigeration system using the HFC-134a and scroll compressor is performed numerically. The refrigeration system mainly consists of various standard components such as heat exchanger, compressor, and expansion device. The model for heat exchanger performance is based on a tube-by-tube method which is analyzed separately by considering the cross-flow heat transfer with the outdoor air flow and pressure drop. Compressor is used the scroll-type compressor which has many merits such as high efficiency, low noise and vibration, and small in size. Short-tube is included as an expansion device. Vapour and liquid line are also considered for the performance analysis of refrigeration system. Using the modeling of various components of refrigeration system, a performance comparison of CFC-12 and HFC-134a is performed numerically for the various outdoor air temperature and various values of short-tube diameter. As the results of this study, the refrigeration system performance decreases as the outdoor air temperature increases. And the optimum short-tube diameter based on COP is 1.37mm for this system.

  • PDF

Feasibility Analysis of STATCOM Application for Jeiu-Haenam HVDC System (제주-해남 HVDC 시스템에 STASTCOM 적용 타당성 분석)

  • Baek Seung-Taek;Choo Won-Gvo;Han Byung-Moon;Jang Gil-Soo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.8
    • /
    • pp.401-409
    • /
    • 2005
  • This paper describes a feasibility analysis result of STATCOM application for the Jeju-Haenam HVDC system. The Jeju-Haenam HVDC system is one of the typical HVDC system interconnected with the low short-circuit-ratio AC system, which is vulnerable to the commutation failure due to the AC voltage variation. STATCOM has been considered as an effective reactive-power compensator to increase short-circuit-ratio of the interconnected AC system. In this study, a simulation model of Jeju-Hacnam HVDC system with STATCOM was developed using PSCAD/EMTDC. The developed simulation model was utilized to analyze the dynamic performance analysis of Jeju-Haenam HVDC system with STATCOM. The analysis results show that STATCOM can improve the dynamic performance of Jeju-Haenam HVDC system, such as load-change recovery performance and fault recovery performance.

Feasibility Analysis of STATCOM Application for Jeju-Haenam HVDC System (제주-해남 HVDC 시스템에 STATCOM 적용 타당성 분석)

  • Baek, Seung-Taek;Han, Byung-Moon;Jang, Gil-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.60-62
    • /
    • 2005
  • This paper describes a feasibility analysis result of STATCOM application for the Jeiu-Haenam HVDC system. The Jeju-Haenam HVDC system is one of the typical HVDC system interconnected with the low short-circuit-ratio AC system, which is vulnerable to the commutation failure due to the AC voltage variation. STATCOM has been considered as an effective reactive-power compensator to increase short-circuit-ratio of the interconnected AC system. In this study, a simulation model of Jeju-Haenam HVDC system with STATCOM was developed using PSCAD/EMTDC. The developed simulation model was utilized to analyze the dynamic performance analysis of Jeju-Haenam HVDC system with STATCOM. The analysis results show that STATCOM can improve the dynamic performance of Jeju-Haenam HVDC system, such as load-change recovery performance and fault recovery performance.

  • PDF

Evaluation Method for Measurement System and Process Capability Using Gage R&R and Performance Indices (게이지 R&R과 성능지수를 이용한 측정시스템과 공정능력 평가 방법)

  • Ju, Youngdon;Lee, Dongju
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.2
    • /
    • pp.78-85
    • /
    • 2019
  • High variance observed in the measurement system can cause high process variation that can affect process capability badly. Therefore, measurement system analysis is closely related to process capability analysis. Generally, the evaluation for measurement system and process variance is performed separately in the industry. That is, the measurement system analysis is implemented before process monitoring, process capability and process performance analysis even though these analyses are closely related. This paper presents the effective concurrent evaluation procedure for measurement system analysis and process capability analysis using the table that contains Process Performance (Pp), Gage Repeatability & Reproducibility (%R&R) and Number of Distinct Categories (NDC). Furthermore, the long-term process capability index (Pp), which takes into account both gage variance and process variance, is used instead of the short-term process capability (Cp) considering only process variance. The long-term capability index can reflect well the relationship between the measurement system and process capability. The quality measurement and improvement guidelines by region scale are also described in detail. In conclusion, this research proposes the procedure that can execute the measurement system analysis and process capability analysis at the same time. The proposed procedure can contribute to reduction of the measurement staff's effort and to improvement of accurate evaluation.