• Title/Summary/Keyword: System Loss Factor

Search Result 594, Processing Time 0.03 seconds

AEffects of Impeller Blade Thickness on Performance of a Turbo Blower (임펠러 블레이드 두께가 터보블로워 성능에 미치는 영향)

  • Park, Jun-Young;Park, Moo-Ryong;Hwang, Soon-Chan;Ahn, Kook-Young
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.4
    • /
    • pp.5-10
    • /
    • 2010
  • This study is concerned with effects of impeller blade thickness on performance of a turbo blower. This turbo blower is developed as an air supply system in 250 kW MCFC system. The turbo blower consists of an impeller, two vaneless diffusers, a vaned diffuser and a volute. The three dimensional, steady state numerical analysis is simultaneously conducted for the impeller, diffuser and volute to investigate the performance of total system. To consider the non-uniform condition in volute inlet due to volute tongue, full diffuser passages are included in the calculation. The results of numerical analysis are validated with experimental results of thin blade thickness. Total pressure ratio, efficiency, slip factor and blade loading are compared in two cases. The slip factor is different in two cases and the comparison of two cases shows a good performance in thin blade thickness in all aspects.

A Method of Analysis to Predict Sound Transmission Loss of an Extruded Aluminum Panel for Use on Railway Vehicles (철도차량용 알루미늄 압출재의 음향 투과손실 예측에 관한 연구)

  • Kim, Kwanju;Lee, Jun-Heon;Kim, Dae-Yong;Kim, Seock-Hyun
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.1
    • /
    • pp.20-25
    • /
    • 2013
  • The frame elements of modern high speed trains are typically fabricated with extruded aluminum panels. However, the sound transmission loss (STL) of extruded aluminum panels is less satisfactory than flat panels with the same surface density. This study proposes a method for prediction of the sound transmission loss of extruded aluminum panels using finite element analysis. The panel is modeled by finite element analysis, and the STL is calculated using a measure of Sommerfeld radiation at the specimen surface, boundary conditions, and the internal loss factor of the material. In order to verify the validity of the predicted value, intensity transmission loss was measured on the aluminum specimen according to ASTM E2249-02. The proposed method of analysis will be utilized to predict the sound insulation performance of extruded aluminum panels for railway vehicles in the design stage, and to establish measures for their improvement.

High Power Factor and High Efficiency DC-DC Converter using Single-Pulse Soft-Switching (단일 펄스 소프트 스위칭을 이용한 고역률 고효율 DC-DC 컨버터)

  • Jung, S.H.;Kwon, S.K.;Suh, K.Y.;Lee, H.W.;Gac, D.K.;Kim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1148-1150
    • /
    • 2003
  • Power conversion system must be increased switching frequency in order to achieve a small size, a light weight and a low noise. However, the switches of converter are subjected to high switching power losses and switching stresses. As a result of those, the power system brings on a low efficiency. To improved these, a large number of soft switching topologies included a resonant circuit has been prosed. But these circuits increase number of switch in circuit and complicate sequence of switching operation. In this paper, the authors propose a high power factor and high efficiency DC-DC converter using single-pulse soft switching by partial resonant switching node. The switching devices in a prosed circuit are operated with soft switching by the partial resonant method, that is, Partial Resonant Switch Mode Power Converter. The partial resonant circuit makes use of a inductor using step up and a condenser of loss-less snubber. The result is that the switching loss is very low and the efficiency of system is high. Also the proposed converter is deemed the most suitable for high power applications where the power switching devices are used. Some simulative results on computer results are included to confirm the validity of the analytical results.

  • PDF

Power Factor Correction of Switched Reluctance Motor Drive System using Boost Converter (승압형 컨버터를 이용한 SRM의 구동시스템 역률개선)

  • Yoon Yong-Ho;Kim Jae-Moon;Lee Tae-Won;Kim Hack-Seong;Won Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.211-218
    • /
    • 2005
  • Switched Reluctance Motor(SRM) offers the advantages of simple and robust motor construction, high speed and high efficiency over a wide operating range of torque and speed, excellent controllability. However SRM has the disadvantages of high current harmonics, and low power factor because the required output of speed and torque is produced by the discontinuous and loss of power system, and brings about the incorrect operation of electronic system. This paper deals with an energy efficient converter fed SRM system with the reduced harmonics and improved power factor. The validity of the proposed scheme is verified via experiments. We are implemented the proposed control system using 80C196KC micro-controller.

Design Factor Calculation and Analysis of Grid-Connected Photovoltaic System (계통연계형 태양광발전시스템의 설계계수 산출분석)

  • So, Jung-Hun;Hwang, Hye-Mi;Jung, Young-Seok;Ko, Suk-Whan;Ju, Young-Chul;Lim, Hyun-Mook
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.89-94
    • /
    • 2013
  • This paper presents a simple but valid design factor calculation method of grid-connected photovoltaic system using normalized yield model. The proposed calculation method can be represented as a quantitative value about five design factors from irradiance to system output power. The validity of this method is identified by analyzing design factor with three years monitored data. These results will indicate that it is useful to determine the optimal design and selection of grid-connected photovoltaic system to meet different user purposes and enhance long-term reliability and stability of grid-connected photovoltaic system.

MIMO Radio Channel Measurement and Analysis at 781MHz (781MHz 대역에서 MIMO 전파 채널 측정 및 분석)

  • Jeong, Won-Ho;Kim, Joo-Seok;Jung, Myoung-Won;Yoon, Young-Keun;Kim, Jong-Ho;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.181-188
    • /
    • 2012
  • In this paper, the measurement data is analyzed and channel parameters are derived through MIMO Channel measurements at 781MHz considering outdoor multi-path environment. 781MHz frequency band currently operates the DTV system. However, it will be allocated new mobile communication frequency band. The channel characteristics at 781MHz seem to be similar existing mobile communication system at 900MHz but a study on channel characteristics of signal transfer process is necessary because there is incomplete study in mobile networks at 781MHz. To avoid interference with Korean DTV broadcasting, we measured channel characteristics in city/suburban areas of Jeju island by channel sounder and $4{\times}4$ antenna of the ETRI(Korea Electronics and Telecommunications Research Institute). Path Loss, Delay Spread, Angular Spread and K-factor were derived based on measured data.

Computing the Half-Month Rainfall-Runoff Erosivity Factor for RUSLE (RUSLE을 위한 반월 주기 강우가식성인자 산정)

  • 강문성;박승우;임상준;김학관
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.3
    • /
    • pp.29-40
    • /
    • 2003
  • The objective of the paper is to compute the half-month rainfall-runoff erosivity factor for revised universal soil loss equation (RUSLE). RUSLE is being used to develop soil conservation programs and identify optimum management practices. Rainfall-runoff erosivity factor (R) is a key input parameter to RUSLE. Rainfall-runoff erosivity factor has been calculated for twenty six stations from the nationwide rainfall data from 1973 to 2002 in south Korea. The average annual Rainfall-runoff erosivity factor at the analyzed stations Is between 3,130 and 10,476 (MJ/ha)ㆍ(mm/h). According to the computation of the half-month Rainfall-runoff erosivity factor for locations, 66-85% of the average annual R value has occurred during the summer months, June-August. The half-month R values from this study can be used for RUSLE.

Investigating the Effects of Hearing Loss and Hearing Aid Digital Delay on Sound-Induced Flash Illusion

  • Moradi, Vahid;Kheirkhah, Kiana;Farahani, Saeid;Kavianpour, Iman
    • Journal of Audiology & Otology
    • /
    • v.24 no.4
    • /
    • pp.174-179
    • /
    • 2020
  • Background and Objectives: The integration of auditory-visual speech information improves speech perception; however, if the auditory system input is disrupted due to hearing loss, auditory and visual inputs cannot be fully integrated. Additionally, temporal coincidence of auditory and visual input is a significantly important factor in integrating the input of these two senses. Time delayed acoustic pathway caused by the signal passing through digital signal processing. Therefore, this study aimed to investigate the effects of hearing loss and hearing aid digital delay circuit on sound-induced flash illusion. Subjects and Methods: A total of 13 adults with normal hearing, 13 with mild to moderate hearing loss, and 13 with moderate to severe hearing loss were enrolled in this study. Subsequently, the sound-induced flash illusion test was conducted, and the results were analyzed. Results: The results showed that hearing aid digital delay and hearing loss had no detrimental effect on sound-induced flash illusion. Conclusions: Transmission velocity and neural transduction rate of the auditory inputs decreased in patients with hearing loss. Hence, the integrating auditory and visual sensory cannot be combined completely. Although the transmission rate of the auditory sense input was approximately normal when the hearing aid was prescribed. Thus, it can be concluded that the processing delay in the hearing aid circuit is insufficient to disrupt the integration of auditory and visual information.

Losses Comparison and Analysis for Fault Modes of Grid-connected Photovoltaic System (계통연계형 태양광발전 시스템의 고장유형별 손실 비교분석)

  • So, Jung-Hun;Ko, Suk-Whan;Ju, Young-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.3
    • /
    • pp.23-32
    • /
    • 2017
  • This paper presents losses comparison and analysis results for different types of fault modes of grid-connected photovoltaic system generated for long-term operation. The approach of losses comparison and analysis by faults is to identify relationship between measured and estimated values of five loss factors which are quantified from irradiance to system output power. This paper presents the symptom results for faults such as snow, shading, sensor defect, blackout, soiling and so on from three years or more monitored data. These results will indicate that it is useful to develop fault detection and diagnosis tool to enhance capacity factor and save operation and maintenance cost of grid-connected photovoltaic system in the field.

Dielectric and Piezoelectric Properties of Pb(Zr1/2Ti1/2)O3-Pb(Cu1/3Nb2/3)O3-Pb(Mn1/3Nb2/3)O3 System (Pb(Zr1/2Ti1/2O3-Pb(Cu1/3Nb2/3)O3-Pb(Mn1/3Nb2/3)O3계의 유전 및 압전 특성)

  • Lee, Hyeung-Gyu;Kang, Hyung-Won;Choi, Ji-Hyun
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.10 s.281
    • /
    • pp.698-702
    • /
    • 2005
  • Dielectric and Piezoelectric properties of complex perovskite 0.92Pb($Zr_{1/2}Ti_{1/2})O_{3}-(0.08-x)Pb(Cu_{1/3}Nb_{2/3})O_{3}-xPb(Mn_{1/3}Nb_{2/3})O_{3}(0{\leq}x{\leq}0.080$) (PZT-PCN-PMN) system were investigated as a function of PMN content. With the increase of PMN content of the sintered specimens, tetragonal phase was coexisted with rhombohedral phase, the dielectric constant was decreased, mechanical quality factor ($Q_{m}$) was inceased, and optimal sintering temperature was increased up to 1050$^{\circ}C$. For the composition of x = 0.064 sintered at 1050$^{\circ}C$ for 2 h, 1939 of maximum mechanical quality factor ($Q_{m}$), 57$\%$ of electromechanical coupling factor ($k_{p}$), and 1100$^{\circ}C$ of dielectric constant, 0.37$\% $ of dielectric loss (tan $\delta$) were obtained.