• 제목/요약/키워드: System Frequency Response

검색결과 2,028건 처리시간 0.037초

벡터 회로망 분석기 측정을 기반으로 한 3상 변압기의 시간영역 펄스 신호에 대한 응답 분석 (The Response to Impulse Signal on Three Phase Transformer using Vector Network Analyzer)

  • 김광호;정종만;나완수
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.79-84
    • /
    • 2015
  • Transformer is widely used element on power system and industrial area. Especially the transformers installed at power system are exposed to an environment of arbitrary changed. Thus the prediction of degradation and the analysis of response to impulse are important. To conduct those works, the electrical characteristics of system should be analyzed, effectively. But the analysis of electrical characteristic in electric machine level such as pole and pad-mounted transformer is almost no, thus commercial VNA (Vector Network Analyzer) is used to getting the response in wide frequency range. However, the output power of VNA is usually under 10mW, so verification for effectiveness of measuring electrically large component should be conducted, firstly. Next, after getting total S-parameter of transformer, predicting impulse response can be performed in time-domain with circuit simulator. In this paper, it is introduced that verification effectiveness of VNA using transfer function from SFRA (Sweep Frequency Response Analyzer), firstly. Next, total S-parameter, six by six matix form, was built using measured 2 port S-parameter from vector network analyzer. To get the response to impulse which is defined by IEC 60060-1, time-domain simulation is conducted to ADS (Advenced Design System) circuit simulator.

푸리에 변환과 주파수 민감도를 이용한 시변자장 시스템에서의 과도상태 해석 (Transient Analysis of Magnetodynamic Systems Using Fourier Transform and Frequency Sensitivity)

  • 최명준;김창현;박일한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.64-66
    • /
    • 1998
  • This paper presents a new efficient method for transient analysis in magnetodynamic systems of linear eddy current problems. This mehtod employs the Fourier transform and the high-order frequency sensitivity of harmonic finite element method. By taking into account the time-constant of magnetodynamic system, the Fourier integral of continuous frequency is converted into the Fourier series of discrete frequency. And with the results of Fourier series expansion of converted input wave form, the responses of each sinusoids is superposed to give the total response of the magnetodynamic systems. But, if the frequency band of input wave form is broad, it takes long computational time since all responses for each sinusoids must be calculated. Therefore, the high-order frequency sensitivity method is employed to estimate the response variation to frequency. The proposed algorithm is applied to an induction heating system to validate its numerical efficiency.

  • PDF

Experimental Examination of Multivariable PID Controller Design on Frequency Domain using Liquid Level Process

  • Eguchi, Kazuki;Iwai, Zenta;Mizumoto, Ikuro;Kumon, Makoto
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.786-791
    • /
    • 2005
  • This paper is concerned with the examination and evaluation concerning a tuning method of multivariable PID controllers based on partial model matching on frequency domain proposed by authors from practical view point. In this case, PID controller parameters are determined by minimizing the loss function defined by the difference between frequency response of ideal model transfer function and actual frequency response on several frequency points. The purpose of the paper is to examine and evaluate the performance of the method through actual experiments of MIMO liquid level experimental process control equipment.

  • PDF

고 응답 유량제어 서보밸브의 주파수 응답특성에 관한 연구 (A Study on the Frequency Response Characteristics of High Response Flow Control Servo Valve)

  • 서종수;신유식;지명국;전영흥;정효민;정한식
    • 설비공학논문집
    • /
    • 제15권6호
    • /
    • pp.480-488
    • /
    • 2003
  • The purpose of this research Is to derive the principal design parameters governing the dynamic characteristics of the high response flow control servo valve. For this purpose, a numerical modeling of the servo valve system and a parameter sensitivity analysis to a frequency response characteristics was peformed. As a result of these analysis, a basis for improvement of a dynamic characteristics of servo valve was arranged.

음향 보상 시스템에 관한 연구 (A Study on the Audio Compensation System)

  • 정병철;원충상
    • 한국음향학회지
    • /
    • 제32권6호
    • /
    • pp.509-517
    • /
    • 2013
  • 본 연구에서는 음성전기변환기로서 다이나믹 마이크로폰과 디지털 신호처리기를 사용하고 성능분석을 통해 좋은 음성신호를 출력하는 방법을 다루었다. 음성음향시스템의 성능이라 함은 음성신호를 왜곡하지 않고 얼마나 원음 특성을 충실하게 증폭하여 확성하는가를 뜻한다. 마이크로폰의 주파수 응답특성을 측정한 후, 신호처리방법으로 표준마이크로폰 주파수 응답특성과 비교하여 주파수대역 별 보정치를 구하였다. 본 논문에 사용된 마이크로폰과 스피커는 일반적으로 사용되는 제품으로, 주파수응답특성을 구하고 기준치와 비교하여 필요한 보정치를 구하였다. 이와 같이 구한 마이크로폰과 스피커의 보정치는 디지털신호처리방법으로 처리하여 원신호음에 가깝게 보상하였다. 그리고 음성음원과 수음마이크 사이의 거리변화에 의한 음향특성변화보상에 관한 측정 결과도 비교적 좋은 결과를 얻었다.

구조물-가진기 상호작용에 의한 공진주파수 변동에 대한 해석 (Analysis on the Measured Natural Frequencies Due to the Structure-Exciter Interaction)

  • 한상보
    • 대한기계학회논문집A
    • /
    • 제20권7호
    • /
    • pp.2108-2117
    • /
    • 1996
  • The purpose of this paper is to investigate the influence of the exciter attached for the measurement of natural frequencies when extracting the frequency response functions of the test structure in experimental modal analysis. The procedure is first to model the attached exciter as an additional degree of freedom system and next to verify the suggested model by experimentally extracting the natural frequencies of the test structure with various values of exciter mass, stinger stiffness and attachment position of the exciter on the test structure. It is concluded that as additional degree of freedom system which includes the natural frequency of the exciter itself and axial stiffness of stinger should be considered to quantatively define the coupling effects of structure-exciter interaction on the measured natural frequencies. It is not the mass of the exciter itself but the coupling effect of the additional degree of freedom mass-spring system consisting of exciter body and armature coil that characterizes the natural frequency deviation. Therefore, when the natural frequency of this additional mass-spring system is outside of the test frequency range, the coupling effect of structure-exciter interaction can be minimized.

윈도우즈 GUI 환경을 이용한 모터내장형 고속주축계의 정특성/동특성 해석시스템 개발

  • 이용희;김석일;이재윤
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.836-840
    • /
    • 1995
  • Recently, the motor-integrated spindle spindle systems have been used to simplify the machine tool structure, to improve the motion flexibility of machine tool, and to perform the high-speed machining. In this study, a static and dynamic analysis system for motor-integrated high-speed spindle systems is developed based on Timoshenko theory, finite element method and windows programming techniques. Since the system has various analysis modules related to static deformation analysis, modal analysis, frequency response analysis, unbalance response analysis and so on, it is useful in performing systematically the design and evaluation processes of motor-integrated high-speed spindle systems under windows GUI encironment.

  • PDF

적층식 압전소자를 이용한 고속 서보밸브 시스템의 개발 (Development of a High-Speed Electrohydraulic Servovalve System Using Stack-Type Piezoelectric Elements)

  • 방영봉;이교일;임원규;주춘식;허재웅
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.733-736
    • /
    • 2003
  • This paper presents two systems of two-stage electrohydraulic servovalve with a nozzle-flapper pilot stage, which is controlled by stack-type piezoelectric elements. Two flapper moving mechanisms proposed in this research can compensate for the hysteresis problem and thermal expansion of the piezoelectric elements. The experimental results show that the first flapper moving mechanism has the frequency response of over 500 Hz and the second one has the response of over 600 Hz. And the first simplified servovalve system rising the first flapper moving mechanism has the frequency response of about 150 Hz, and the second system has the response of about 300 Hz at the supply pressure of 210 bar

  • PDF

The Influence of Coupling Coefficient between Wayside Transmitter and On-board Receiver upon Operation Characteristics of the ATS System

  • Kim, Min-Seok;Kim, Min-Kyu;Lee, Sang-Hyeok;Lee, Jong-Woo
    • International Journal of Railway
    • /
    • 제4권1호
    • /
    • pp.12-18
    • /
    • 2011
  • The ATS system is used to provide wayside signaling. Currently, the oscillation frequency is set at 78[kHz] in the normal state. As the on-board receiver crosses over the wayside transmitter, the oscillation frequency is changed by capacitors of the wayside transmitter in a manner dependent on the train speed. As the oscillation frequency is changed, the waveform is modified in the wayside transmitter as well as in the on-board receiver. When there are other signal systems such as a ATO system present near the wayside transmitter, frequency interference occurs. This phenomenon arises since other signals or communication frequencies present will be included in the waveform. Trains often stop due to these other frequencies included in the waveform. In this paper, a model of the interaction between the wayside transmitter and on-board receiver is suggested and frequency response in the wayside transmitter and on-board receiver in the presence of the other signals are estimated by the coupling coefficient. Also, the coupling coefficients are estimated, and the optimal value is proposed.

Predistortion for Frequency-Dependent Nonlinearity of a Laser in RoF Systems

  • Najarro, Andres C.;Kim, Sung-Man
    • Journal of information and communication convergence engineering
    • /
    • 제14권3호
    • /
    • pp.147-152
    • /
    • 2016
  • In radio-over-fiber (RoF) systems, nonlinear compensation is essential to improve performance. Among the several existing nonlinear compensation techniques, we investigate a predistortion technique for a directly modulated laser in an RoF system. First, we obtain the input-to-output response of a directly modulated laser at 160, 820, and 1,540 MHz. The results show that the laser response is dependent on the frequency band. Second, we design an optimal predistortion circuit to compensate for the nonlinear responses of three frequency bands. We design the predistortion circuit with two options: each predistortion circuit for each frequency band and one single predistortion circuit for all the three frequency bands. Finally, we present the simulation results of the predistortion system obtained using a commercial simulator. These results show that the third intermodulation distortion (IMD3) is improved by 0.6-9 dB for the three frequency bands with only a single predistortion circuit.