• 제목/요약/키워드: System Condensation Technique

검색결과 65건 처리시간 0.021초

적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석 (INFRARED THERMOGRAPHIC ANALYSIS OF TEMPERATURE RISE ON THE SURFACE OF BUCHANAN PLUGGER)

  • 최성아;김선호;황윤찬;윤창;오병주;최보영;정우남;정선와;황인남;오원남
    • Restorative Dentistry and Endodontics
    • /
    • 제27권4호
    • /
    • pp.370-381
    • /
    • 2002
  • This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spling. The heat carrier system 'System B' (Model 1005, Analytic Technologies, USA) and the Buchanan's plug-gers of F, FM, M and ML sizes are used for this study. The temperature was set to 20$0^{\circ}C$ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infrared thermography (Radiation Thermometer-IR Temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it (p<0.001). 2. When the pluggerss were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3$\pm$10.5$^{\circ}C$ to 192.1$\pm$3.3$^{\circ}C$ in a touch for 1 sec, from 218.6$\pm$5.$0^{\circ}C$ to 179.5$\pm$4.2$^{\circ}C$ in a touch for 2 sec, from 197.5$\pm$3.$0^{\circ}C$ to 167.5$\pm$3.7$^{\circ}C$ in a touch for 3 sec, from 183.7$\pm$2.5$^{\circ}C$ to 159.8$\pm$3.6$^{\circ}C$ in a touch for 4 sec and from 164.9$\pm$2.$0^{\circ}C$ to 158.4$\pm$1.8$^{\circ}C$ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temperature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature does not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommend, and finally a quick touch of heat control spring for 1sec reveals the highest temperature rise.

치근단절제 및 역충전와동 형성방법이 치근단누출에 미치는 영향 (INFLUENCES OF APICOECTOMY AND RETROGRADE CAVITY PREPARATION METHODS ON THE APICAL LEAKAGE)

  • 양정옥;김성교;권태경
    • Restorative Dentistry and Endodontics
    • /
    • 제23권2호
    • /
    • pp.537-549
    • /
    • 1998
  • 본 연구의 목적은 미세치근단 수술법에서 사용되는 치근단 절제방법 및 역충전와동 술식을 종래의 치근단 수술법에서 사용해 온 술식 및 방법과 치근단 미세누출의 측면에서 비교, 연구하고자 함이다. 치근단 절제방법 및 역충전와동 형성 방법에 따른 치근단 누출을 평가하기 위해서는 최근에 발거된 상악 중절치, 측절치 및 견치 71개를 절제 각도 및 와동 형성방법에 따라 5개의 군으로 분류하여 실험하였으며, 근관협부 처리에 따른 치근단 누출을 평가하기 위해서는 최근 발거된 상악 제 1대구치의 근심협측 치근 44개를 근관협부의 처리 유무에 따라 2개군으로 분류하여 실험하였다. 각 시편치아에서 근관을 형성하고 측방가압법으로 충전한 후 각 군에 따라 저속 다이아몬드 절단기를 이용하여 치근단 3 mm를 절제하였으며 저속 round bur와 초음파 스테인레스 스틸 기구를 이용하여 역충전와동을 형성하고 IRM으로 역충전하였다. 시편을 2% methylene blue 용액에 7일간 침잠시킨 후 35% 질산 용액에서 용해시킨 다음, 원심분리한 상층액을 비색계를 이용하여 누출 색소의 홉광도를 측정하였다. 결과치는 이원변량분석법과 Duncan's Multiple Range Test를 이용하여 분석하였으며, 다음과 같은 결과를 얻었다. ${\cdot}$ 사면을 부여하지 않고 치아 장축에 대해 직각이 되게 치근단을 절제하고 치아 장축에 평행하게 역충전와동을 형성한 경우, 초음파기구를 이용한 군과 저속 round bur를 이용한 군사이에는 미세누출에 있어서 유의한 차이가 나타나지 않았다(p>0.05). ${\cdot}$ 사면을 부여하면서 치근단을 절제하고 치아 장축에 평행하게 역충전와동을 형성한 경우, 초음파기구를 이용한 군은 저속 round bur를 이용한 군에 비해 유의하게 적은 치근단 누출을 보였다(p<0.0001). ${\cdot}$ 초음파기구를 이용하여 역충전와동을 형성한 경우에는, 치근단 절제시 사면의 부여에 관계없이 치근단 누출에 유의한 차이가 나타나지 않았으나(p>0.05), 저속 round bur를 이용한 경우에는, 사변을 형성하지 않은 군이 사면을 형성한 군에 비해 유의하게 적은 미세누출을 나타내었다(p<0.0001). ${\cdot}$ 치근단 절제시 사변을 부여한 경우에는, 저속 round bur로 치아 장축에 평행하게 역충전와동을 형성한 군은 치아 장축에 직각으로 역충전와동을 형성한 군에 비해 미세누출이 적게 나타났지만, 유의한 차이는 나타나지 않았다(p>0.05). ${\cdot}$ 초음파 기구를 이용하여 근관협부를 따라 역충전 와동을 형성한 군은 저속 round bur를 이용하여 근관협부를 따라 역충전 와동을 형성하지 못한 군에 비해 유의하게 적은 치근단 누출을 나타내었다(p<0.0001).

  • PDF

다른 특성을 가지는 도재가 반복소성에 따라 색조변화에 미치는 영향 (The Effect of Repeated Firing on the Color Difference of a Metal-Ceramic System with Different Porcelain Powder)

  • 황재선
    • 대한치과기공학회지
    • /
    • 제31권1호
    • /
    • pp.23-36
    • /
    • 2009
  • The goal of esthetic restoration is to achieve morphologic, optical, and biologic acceptance. Creation of a natural looking ceramic restoration, which blends harmoniously with surrounding dentition, is not always achieved. A successful color match is an important aspect of any esthetic dental restoration. Since natural enamel has inherent translucency, it is important that ceramic restorations reproduce the translucency and color of the natural teeth. However, the final color match of porcelain crowns to adjacent natural dentition remains some problem. Difficulties related to color matching arise from the structural differences that exist between metal ceramic crowns and natural teeth, the limited range of available ceramic shades, inadequate shade guides, different types of metal alloys, repeated firing, the condensation technique, and varying compositions of ceramic materials. Many factors contribute to the esthetic success of dental restoration: optical properties such as color and its elements of hue, value, and chroma; translucency and opacity; light transmission and scattering; and metamerism and fluorescence. The purpose of this study was to determine the color changes of metal-ceramic system with different veneering porcelain powder after repeated firing. The objectives of this in vitro study were to measure the lightness($L^*$), chromaticity($a^*$), chromaticity($b^*$), chroma($C^*$), hue(h), reflectance(%), color difference(${\Delta}E$). The following conclusions were obtained: 1. An increase in the number of firings resulted in decrease in lightness($L^*$) but increase in chromacticity($a^*$) with all porcelain. After the second sintering resulted in decrease in chromacticity($b^*$) with opaque-dentin porcelain and dentin porcelain but in increase with enamel porcelain and translucency porcelain. And after the second sintering resulted in decrease in chroma($C^*$) with opaque-dentin porcelain and dentin porcelain, but on the whole side in decrease with enamel porcelain and translucency porcelain. 2. After the second firing, a increase in the number of firings resulted in decrease reflectance(%) in all wavelength. 3. There were noticeable color differences(${\Delta}E$) between first sintering and multiple firings(dentin porcelain: 5.29~8.15, opaque-dentin porcelain: 4.83~8.2, enamel porcelain: 8.93~13.15, translucency porcelain: 9.37~12.91), but the color difference(${\Delta}E$) after second sintering were down to 4.87 in all porcelain. 4. Given the NBS Criteria, a 'trace' was not found this study but a 'slight' was found 2-3, 3-5 in dentin porcelain, 2-3 in opaque-dentin porcelain, 3-5, 5-10 in enamel porcelain and translucency porcelain, a 'noticeable' was 2-5, 3-10, 5-10 in dentin porcelain and opaque-dentin porcelain, 2-3, 2-5, 3-10 in enamel porcelain 2-3, 3-10 in translucency porcelain, an 'appreciable' was 1-2, 1-3, 2-10 in dentin porcelain 1-2, 1-3, 2-10, 3-10 in opaque-dentin porcelain, 2-10 in enamel porcelain, 2-5, 2-10 in translucency porcelain, a 'much' was 1-5, 1-10 in dentin porcelain and opaque-dentin porcelain, 1-2, 1-3, 1-5 in enamel porcelain 1-2, 1-3, 1-5, 1-10 in translucency porcelain, a 'very much' was 1-10 in enamel porcelain.

  • PDF

명시적 호장법을 이용한 공간프레임의 반강접 탄소성 후좌굴 해석 (Semi-rigid Elasto-Plastic Post Buckling Analysis of Space Frame by Using the Explicit Arc-Length Method)

  • 이경수;한상을
    • 한국강구조학회 논문집
    • /
    • 제23권5호
    • /
    • pp.535-546
    • /
    • 2011
  • 본 연구에서는 다양한 명시적 호장법을 사용하여 공간프레임의 반강접 탄소성 후좌굴 해석을 수행하였다. 이를 위해 이전 연구를 발전시켜 다양한 명시적 알고리즘의 호장법과 명시적, 묵시적 해석법에 동시에 적용 가능한 반강접 탄소성 공간프레임요소를 제안하였다. 다양한 명시적 호장법은 예측단계와 수렴단계에 명시적 해석법인 동적이완법을 적용한 것을 의미한다. 따라서 명시적 호장법에는 명시적(예측단계)-명시적(예측단계) 호장법, 명시적(예측단계)-묵시적(수렴단계) 호장법, 묵시적(예측단계)-명시적(수렴단계) 호장법으로 구분된다. 또한 명시적 호장법에 적용 가능하도록 수정된 반강접 탄소성 공간프레임요소는 오일러리안 유한변형이론에 의해 강체회전변형을 고려하였기 때문에 대변위가 발생하는 기하학적 비선형 문제에 적용될 수 있고, 완전 탄소성 소성힌지 알고리즘에 의한 재료적 비선형성을 고려하였으며, 부재내부에 정적 응축된 회전 및 축방향 성분의 선형 스프링에 의해 접합부 반강접 특성을 반영하였다. 제안된 해석법을 이용하여 검증예제를 수행함으로써 본 연구에서 제안된 다양한 명시적 호장법 및 공간프레임요소의 정확성을 검증한다.

치근단 역충전와동의 건조방법이 폐쇄성에 미치는 영향 (INFLUENCES OF DRY METHODS OF RETROCAVITY ON THE APICAL SEAL)

  • 이정태;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제24권1호
    • /
    • pp.166-179
    • /
    • 1999
  • 외과적 근관치료에서 근단부의 폐쇄성은 성공에 필수적이다. 그리고 외과적 근관치료시 근단부 역충전와동은 습기나 혈액에 의해 오염되기 쉬우며 와동을 이상적으로 건조하기가 항상 용이하지는 않다. 본 연구의 목적은 미세 치근단 수술법에서 치근단 역충전와동의 건조 방법이 폐쇄성에 미치는 영향을 연구하고자 함이다. 치근단 폐쇄성은 근단 누출 및 충전물-와벽 적합성으로 평가하였다. 치근단 역충전와동 건조방법에 따른 치근단 누출을 평가하기 위해서는 최근에 발거된 상악 대구치 구개측치근 125개를 와동건조 방법 및 혈액오염에 따라 4개의 군으로 분류하여 실험하였다. 각 시편치아에서 근관을 형성하고 측방가압법으로 충전한 후 각 군에 따라 저속 다이아몬드 절단기를 이용하여 치근단 3 mm를 절제하였으며 초음파 스테인레스 스틸 기구를 이용하여 깊이 3mm의 역충전 와동을 형성하고 IRM, Super EBA 또는 복합레진으로 역충전하였다. 시편을 2% methylene blue 용액에 7일간 침잠시킨 후 35% 질산 용액에서 용해시킨 다음, 원심분리한 상층액을 비색계를 이용하여 누출 색소의 흡광도를 측정하였다. 결과치는 이원변량분석법과 Duncan's Multiple Range Test를 이용하여 분석하였다. 역충전 와동 건조방법에 따른 충전물-와벽 적합성을 평가하기 위해서는 상악 제 1대구치의 구개측 치근 12개를 상기와 같이 4개 군으로 분류하여 근관충전, 역충전와동 형성, 와동 건조 및 역충전을 실험하였으며, 다음과 같은 결과를 얻었다. 1. 압축공기나 paper point로 와동을 건조한 군이, 역충전 와동을 IRM 간이충전재, Super EBA 시멘트 및 복합레진으로 충전한 경우 공히, cottton pellet 만으로 와동을 건조한 군에 비해 적은 치큰단 누출을 나타내었는데 이는 Super EBA 시멘트 충전군에서만 유의한 차이를 나타내었다(p<0.05). 그러나 충전재료에 관계없이 paper point로 와동을 건조한 군과 압축공기로 건조한 군 사이에는 유의한 누출의 차이가 나타나지 않았다. 2. 압축공기로 와동을 건조한 경우에는, 복합레진으로 충전한 군이 IRM이나 Super EBA로 충전한 군에 비해 유의하게 적은 치근단 누출을 나타내었다(p<0.05). 3. 와동을 혈액으로 오염시킨 경우에는, 역충전 와동을 IRM, Super EBA 및 복합레진으로 충전한 군 공히, 압축공기로 와동내부를 건조한 경우에 비해 유의하게 많은 치큰단 누출을 나타내었다(p<0.05). 4. IRM 간이충전재나 Super EBA 시멘트로 역충전와동을 충전한 경우, 와동측벽의 외측 1/2이 내측 1/2에 비해 넓은 충전물-치질 사이 틈을 나타내었다. 5. IRM 간이충전재, Super EBA 시멘트 및 복합레진으로 역충전와동을 충전한 경우 공히, 와동이 혈액에 의해 오염되었거나 와동을 cotton pellet으로만 건조한 경우가 paper point나 압축공기로 와동을 건조한 경우에 비해 와동기저부에 큰 틈을 나타내는 양상을 보였다.

  • PDF